  1. Salinawati B, Hing EY, Fam XI, Zulfiqar MA
    Med J Malaysia, 2015 Aug;70(4):238-42.
    PMID: 26358021 MyJurnal
    AIM: To determine the (i) sensitivity and specificity of ultrasound (USG) in the detection of urinary tract calculi, (ii) size of renal calculi detected on USG, and (iii) size of renal calculi not seen on USG but detected on computed tomography urogram (CTU).
    METHODS: A total of 201 patients' USG and CTU were compared retrospectively for the presence of calculi. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of USG were calculated with CTU as the gold standard.
    RESULTS: From the 201 sets of data collected, 59 calculi were detected on both USG and CTU. The sensitivity and specificity of renal calculi detection on USG were 53% and 85% respectively. The mean size of the renal calculus detected on USG was 7.6 mm ± 4.1 mm and the mean size of the renal calculus not visualised on USG but detected on CTU was 4 mm ± 2.4 mm. The sensitivity and specificity of ureteric calculi detection on USG were 12% and 97% respectively. The sensitivity and specificity of urinary bladder calculi detection on USG were 20% and 100% respectively.
    CONCLUSION: This study showed that the accuracy of US in detecting renal, ureteric and urinary bladder calculi were 67%, 80% and 98% respectively.
    Study site: Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur
    Matched MeSH terms: Sensitivity and Specificity
  2. Othman S, Chia YC, Ng CJ
    Asia Pac Fam Med, 2003;2(4):206-212.
    Aim: To determine the accuracy of urinalysis in the detection of urinary tract infection (UTI) in symptomatic patients at primary care level. Methods: A cross sectional study was undertaken on 100 patients with symptoms of UTI presenting at the Primary Care Clinic of University Malaya Medical Center, Kuala Lumpur, Malaysia during the months of August to November 1999. Their urine samples were tested simultaneously using urine dipstick, urine microscopy and urine culture. Urine culture was used as the gold standard and UTI was diagnosed when the urine culture showed a bacteria count of >= 105 organisms per mL. The sensitivity and specificity of each test was calculated. Results: The prevalence of UTI was 25% in symptomatic patients. The urine dipstick for leukocyte esterase, nitrite and red blood cell had sensitivities of 76, 56 and 76%, respectively. Their specificities were 60, 81 and 61%, respectively. Urine microscopy for leukocytes, red blood cells and bacterial count had sensitivities of 80, 52 and 84%, while their specificities were 76, 80 and 54%, respectively. Conclusion: The prevalence of UTI in the present study was low despite reported symptoms of UTI. Urinalysis is needed to support the diagnosis of UTI. In the present study, while there is accuracy in the urinalysis (as the sensitivities and specificities of various tests are comparable with other studies); lack of precision in each test because of the wide range of 95% confidence interval make it less reliable. Caution should be made in interpreting each test.
    Matched MeSH terms: Sensitivity and Specificity
  3. Scott EM, Bilous RW, Kautzky-Willer A
    Diabetes Technol Ther, 2018 03;20(3):180-188.
    PMID: 29470094 DOI: 10.1089/dia.2017.0386
    BACKGROUND: Accuracy of the FreeStyle Libre™ Flash Glucose Monitoring System has not been evaluated in pregnant women with diabetes. The aim of this study was to determine accuracy (compared to self-monitoring of blood glucose [SMBG]), clinical safety, and acceptability of the FreeStyle Libre System when used at home by this population.

    MATERIALS AND METHODS: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day).

    RESULTS: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events.

    CONCLUSIONS: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.

    Matched MeSH terms: Sensitivity and Specificity
  4. Tattersall GJ, Danner RM, Chaves JA, Levesque DL
    J Therm Biol, 2020 Jul;91:102611.
    PMID: 32716861 DOI: 10.1016/j.jtherbio.2020.102611
    Infrared thermal imaging is a passive imaging technique that captures the emitted radiation from an object to estimate surface temperature, often for inference of heat transfer. Infrared thermal imaging offers the potential to detect movement without the challenges of glare, shadows, or changes in lighting associated with visual digital imaging or active infrared imaging. In this paper, we employ a frame subtraction algorithm for extracting the pixel-by-pixel relative change in signal from a fixed focus video file, tailored for use with thermal imaging videos. By summing the absolute differences across an entire video, we are able to assign quantitative activity assessments to thermal imaging data for comparison with simultaneous recordings of metabolic rates. We tested the accuracy and limits of this approach by analyzing movement of a metronome and provide an example application of the approach to a study of Darwin's finches. In principle, this "Difference Imaging Thermography" (DIT) would allow for activity data to be standardized to energetic measurements and could be applied to any radiometric imaging system.
    Matched MeSH terms: Sensitivity and Specificity
  5. Chin KY, Low NY, Kamaruddin AAA, Dewiputri WI, Soelaiman IN
    Ther Clin Risk Manag, 2017;13:1333-1341.
    PMID: 29070951 DOI: 10.2147/TCRM.S145519
    BACKGROUND: Calcaneal quantitative ultrasound (QUS) is a useful tool in osteoporosis screening. However, QUS device may not be available at all primary health care settings. Osteoporosis self-assessment tool for Asians (OSTA) is a simple algorithm for osteoporosis screening that does not require any sophisticated instruments. This study explored the possibility of replacing QUS with OSTA by determining their agreement in identifying individuals at risk of osteoporosis.

    METHODS: A cross-sectional study was conducted to recruit Malaysian men and women aged ≥50 years. Their bone health status was measured using a calcaneal QUS device and OSTA. The association between OSTA and QUS was determined using Spearman's correlation and their agreement was assessed using Cohen Kappa and receiver-operating curve.

    RESULTS: All QUS indices correlated significantly with OSTA (p<0.05). The agreement between QUS and OSTA was minimal but statistically significant (p<0.05). The performance of OSTA in identifying subjects at risk of osteoporosis according to QUS was poor-to-fair in women (p<0.05), but not statistically significant for men (p>0.05). Changing the cut-off values improved the performance of OSTA in women but not in men.

    CONCLUSION: The agreement between QUS and OSTA is minimal in categorizing individuals at risk of osteoporosis. Therefore, they cannot be used interchangeably in osteoporosis screening.
    Matched MeSH terms: Sensitivity and Specificity*
  6. Darawi MN, Ai-Vyrn C, Ramasamy K, Hua PP, Pin TM, Kamaruzzaman SB, et al.
    BMC Med Genet, 2013;14:27.
    PMID: 23419238 DOI: 10.1186/1471-2350-14-27
    The incidence of Alzheimer's disease, particularly in developing countries, is expected to increase exponentially as the population ages. Continuing research in this area is essential in order to better understand this disease and develop strategies for treatment and prevention. Genome-wide association studies have identified several loci as genetic risk factors of AD aside from apolipoprotein E such as bridging integrator (BIN1), clusterin (CLU), ATP-binding cassette sub-family A member 7 (ABCA7), complement receptor 1 (CR1) and phosphatidylinositol binding clathrin assembly protein (PICALM). However genetic research in developing countries is often limited by lack of funding and expertise. This study therefore developed and validated a simple, cost effective polymerase chain reaction based technique to determine these single nucleotide polymorphisms.
    Matched MeSH terms: Sensitivity and Specificity
  7. Yeang HY, Hamilton RG, Bernstein DI, Arif SA, Chow KS, Loke YH, et al.
    Clin Exp Allergy, 2006 Aug;36(8):1078-86.
    PMID: 16911364 DOI: 10.1111/j.1365-2222.2006.02531.x
    BACKGROUND:
    Hevea brasiliensis latex serum is commonly used as the in vivo and in vitro reference antigen for latex allergy diagnosis as it contains the full complement of latex allergens.

    OBJECTIVE:
    This study quantifies the concentrations of the significant allergens in latex serum and examines its suitability as an antigen source in latex allergy diagnosis and immunotherapy.

    METHODS:
    The serum phase was extracted from centrifuged latex that was repeatedly freeze-thawed or glycerinated. Quantitation of latex allergens was performed by two-site immunoenzymetric assays. The abundance of RNA transcripts of the latex allergens was estimated from the number of their clones in an Expressed Sequence Tags library.

    RESULTS:
    The latex allergens, Hev b 1, 2, 3, 4, 5, 6, 7 and 13, were detected in freeze-thawed and glycerinated latex serum at levels ranging from 75 (Hev b 6) to 0.06 nmol/mg total proteins (Hev b 4). Hev b 6 content in the latex was up to a thousand times higher than the other seven latex allergens, depending on source and/or preparation procedure. Allergen concentration was reflected in the abundance of mRNA transcripts. When used as the antigen, latex serum may bias the outcome of latex allergy diagnostic tests towards sensitization to Hev b 6. Tests that make use of latex serum may fail to detect latex-specific IgE reactivity in subjects who are sensitized only to allergens that are present at low concentrations.

    CONCLUSION:
    Latex allergy diagnostics and immunotherapy that use whole latex serum as the antigen source may not be optimal because of the marked imbalance of its constituent allergens.
    Matched MeSH terms: Sensitivity and Specificity
  8. Hamizan AW, Loftus PA, Alvarado R, Ho J, Kalish L, Sacks R, et al.
    Laryngoscope, 2018 09;128(9):2015-2021.
    PMID: 29602169 DOI: 10.1002/lary.27180
    OBJECTIVES/HYPOTHESIS: Polypoid edema of the middle turbinate is a marker of inhalant allergy. Extensive edematous changes may result in limited central nasal and sinus disease, which has been called central compartment atopic disease (CCAD). Radiologically, this is seen as soft tissue thickening in the central portion of the sinonasal cavity with or without paranasal sinus involvement. When the sinuses are involved, the soft tissue thickening spares the sinus roof or lateral wall (centrally limited). This centrally limited radiological pattern was assessed among chronic rhinosinusitis (CRS) patients and compared to allergy status.

    STUDY DESIGN: Diagnostic cross-sectional study.

    METHODS: This study included consecutive CRS patients without prior sinus surgery. Computed tomography (CT) scans of the paranasal sinuses were blindly assessed and allergy status was confirmed by serum or skin testing. Individual sinus cavities were defined as either centrally limited or diffuse disease. The radiological pattern that may predict allergy was determined, and its diagnostic accuracy was calculated.

    RESULTS: One hundred twelve patients diagnosed to have CRS, representing 224 sides, were assessed (age 46.31 ± 13.57 years, 38.39% female, 41.07% asthma, Lund-Mackay CT score 15.88 ± 4.35, 56.25% atopic). The radiological pattern defined by centrally limited changes in all of the paranasal sinuses was associated with allergy status (73.53% vs. 53.16%, P = .03). This predicted atopy with 90.82% specificity, 73.53% positive predictive value, likelihood positive ratios of 2.16, and diagnostic odds ratio of 4.59.

    CONCLUSIONS: A central radiological pattern of mucosal disease is associated with inhalant allergen sensitization. This group may represent a CCAD subgroup of patients with mainly allergic etiology.

    LEVEL OF EVIDENCE: 3b Laryngoscope, 128:2015-2021, 2018.

    Matched MeSH terms: Sensitivity and Specificity
  9. Ismail Y
    Med J Malaysia, 1992 Mar;47(1):69-73.
    PMID: 1387454
    To assess the prevalence of skin test sensitivity among asthmatic patients in Malaysia, skin prick tests for allergy in 134 adult asthmatic patients and 120 control subjects were done. 90% of asthmatic patients had positive skin test to at least one allergens as compared to 78% of the controls. House dust mite was the most frequent allergen to which the subjects had positive reactions. Sixty-four percent of the asthmatic patients had associated rhinitis. There was no significant difference in the skin test sensitivity between asthmatic patients with associated rhinitis and those without.
    Matched MeSH terms: Sensitivity and Specificity
  10. Ang GY, Yu CY, Yean CY
    Biosens Bioelectron, 2012 Oct-Dec;38(1):151-6.
    PMID: 22705404 DOI: 10.1016/j.bios.2012.05.019
    In the field of diagnostics, molecular amplification targeting unique genetic signature sequences has been widely used for rapid identification of infectious agents, which significantly aids physicians in determining the choice of treatment as well as providing important epidemiological data for surveillance and disease control assessment. We report the development of a rapid nucleic acid lateral flow biosensor (NALFB) in a dry-reagent strip format for the sequence-specific detection of single-stranded polymerase chain reaction (PCR) amplicons at ambient temperature (22-25°C). The NALFB was developed in combination with a linear-after-the-exponential PCR assay and the applicability of this biosensor was demonstrated through detection of the cholera toxin gene from diarrheal-causing toxigenic Vibrio cholerae. Amplification using the advanced asymmetric PCR boosts the production of fluorescein-labeled single-stranded amplicons, allowing capture probes immobilized on the NALFB to hybridize specifically with complementary targets in situ on the strip. Subsequent visual formation of red lines is achieved through the binding of conjugated gold nanoparticles to the fluorescein label of the captured amplicons. The visual detection limit observed with synthetic target DNA was 0.3 ng and 1 pg with pure genomic DNA. Evaluation of the NALFB with 164 strains of V. cholerae and non-V. cholerae bacteria recorded 100% for both sensitivity and specificity. The whole procedure of the low-cost NALFB, which is performed at ambient temperature, eliminates the need for preheated buffers or additional equipment, greatly simplifying the protocol for sequence-specific PCR amplicon analysis.
    Matched MeSH terms: Sensitivity and Specificity
  11. Adam F, Andas J
    J Colloid Interface Sci, 2007 Jul 1;311(1):135-43.
    PMID: 17391688
    Iron and 4-(methylamino)benzoic acid have been successfully incorporated into silica extracted from rice husk. The silica/Fe/amine complex, RH-Fe(5% amine), showed a ca. 24% increase in specific surface area compared to RH-Fe. This increase was attributed to the templated formation of regular pores. The XRD showed the RH-Fe(5% amine) to be amorphous. The Friedel-Crafts benzylation reaction with toluene using RH-Fe(5% amine) showed a drastic reduction in the di-substituted products to ca. 1.0%.
    Matched MeSH terms: Sensitivity and Specificity
  12. Siddiqui MF, Reza AW, Kanesan J
    PLoS One, 2015;10(8):e0135875.
    PMID: 26280918 DOI: 10.1371/journal.pone.0135875
    A wide interest has been observed in the medical health care applications that interpret neuroimaging scans by machine learning systems. This research proposes an intelligent, automatic, accurate, and robust classification technique to classify the human brain magnetic resonance image (MRI) as normal or abnormal, to cater down the human error during identifying the diseases in brain MRIs. In this study, fast discrete wavelet transform (DWT), principal component analysis (PCA), and least squares support vector machine (LS-SVM) are used as basic components. Firstly, fast DWT is employed to extract the salient features of brain MRI, followed by PCA, which reduces the dimensions of the features. These reduced feature vectors also shrink the memory storage consumption by 99.5%. At last, an advanced classification technique based on LS-SVM is applied to brain MR image classification using reduced features. For improving the efficiency, LS-SVM is used with non-linear radial basis function (RBF) kernel. The proposed algorithm intelligently determines the optimized values of the hyper-parameters of the RBF kernel and also applied k-fold stratified cross validation to enhance the generalization of the system. The method was tested by 340 patients' benchmark datasets of T1-weighted and T2-weighted scans. From the analysis of experimental results and performance comparisons, it is observed that the proposed medical decision support system outperformed all other modern classifiers and achieves 100% accuracy rate (specificity/sensitivity 100%/100%). Furthermore, in terms of computation time, the proposed technique is significantly faster than the recent well-known methods, and it improves the efficiency by 71%, 3%, and 4% on feature extraction stage, feature reduction stage, and classification stage, respectively. These results indicate that the proposed well-trained machine learning system has the potential to make accurate predictions about brain abnormalities from the individual subjects, therefore, it can be used as a significant tool in clinical practice.
    Matched MeSH terms: Sensitivity and Specificity
  13. Engku Nur Syafirah EAR, Nurul Najian AB, Foo PC, Mohd Ali MR, Mohamed M, Yean CY
    Acta Trop, 2018 Jun;182:223-231.
    PMID: 29545156 DOI: 10.1016/j.actatropica.2018.03.004
    Cholera, caused by Vibrio cholerae is a foodborne disease that frequently reported in food and water related outbreak. Rapid diagnosis of cholera infection is important to avoid potential spread of disease. Among available diagnostic platforms, loop-mediated isothermal amplification (LAMP) is regarded as a potential diagnostic tool due to its rapidity, high sensitivity and specificity and independent of sophisticated thermalcycler. However, the current LAMP often requires multiple pipetting steps, hence is susceptible to cross contamination. Besides, the strict requirement of cold-chain during transportation and storage make its application in low resource settings to be inconvenient. To overcome these problems, the present study is aimed to develop an ambient-temperature-stable and ready-to-use LAMP assay for the detection of toxigenic Vibrio cholerae in low resource settings. A set of specific LAMP primers were designed and tested against 155 V. cholerae and non-V. cholerae strains. Analytical specifity showed that the developed LAMP assay detected 100% of pathogenic V. cholerae and did not amplified other tested bacterial strains. Upon testing against stool samples spiked with toxigenic V. cholerae outbreak isolates, the LAMP assay detected all of the spiked samples (n = 76/76, 100%), in contrast to the conventional PCR which amplified 77.6% (n = 59/76) of the tested specimens. In term of sensitivity, the LAMP assay was 100-fold more sensitive as compared to the conventional PCR method, with LOD of 10 fg per μL and 10 CFU per mL. Following lyophilisation with addition of lyoprotectants, the dry-reagent LAMP mix has an estimated shelf-life of 90.75 days at room temperature.
    Matched MeSH terms: Sensitivity and Specificity
  14. Khoo JJ
    Med J Malaysia, 2004 Mar;59(1):50-5.
    PMID: 15535336 MyJurnal
    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.
    Matched MeSH terms: Sensitivity and Specificity
  15. Hajissa K, Zakaria R, Suppian R, Mohamed Z
    BMC Infect Dis, 2017 12 29;17(1):807.
    PMID: 29284420 DOI: 10.1186/s12879-017-2920-9
    BACKGROUND: The inefficiency of the current tachyzoite antigen-based serological assays for the serodiagnosis of Toxoplasma gondii infection mandates the need for acquirement of reliable and standard diagnostic reagents. Recently, epitope-based antigens have emerged as an alternative diagnostic marker for the achievement of highly sensitive and specific capture antigens. In this study, the diagnostic utility of a recombinant multiepitope antigen (USM.TOXO1) for the serodiagnosis of human toxoplasmosis was evaluated.

    METHODS: An indirect enzyme-linked immunosorbent assay (ELISA) was developed to evaluate the usefulness of USM.TOXO1 antigen for the detection of IgG antibodies against Toxoplasma gondii in human sera. Whereas the reactivity of the developed antigen against IgM antibody was evaluated by western blot and Dot enzyme immunoassay (dot-EIA) analysis.

    RESULTS: The diagnostic performance of the new antigens in IgG ELISA was achieved at the maximum values of 85.43% and 81.25% for diagnostic sensitivity and specificity respectively. The USM.TOXO1 was also proven to be reactive with anti- T. gondii IgM antibody.

    CONCLUSIONS: This finding makes the USM.TOXO1 antigen an attractive candidate for improving the toxoplasmosis serodiagnosis and demonstrates that multiepitope antigens could be a potential and promising diagnostic marker for the development of high sensitive and accurate assays.

    Matched MeSH terms: Sensitivity and Specificity
  16. Yap KL, Ooi YE, Khor CM, Wong SH
    Malays J Pathol, 1992 Dec;14(2):105-10.
    PMID: 1338997
    The group A rotavirus staphylococcal co-agglutination test was evaluated and its sensitivity and specificity compared with an in-house enzyme-linked immunosorbent assay (ELISA) and a commercial latex agglutination test (Rotalex). In addition, the storage stability of the staphylococcal reagents was ascertained. Examination of 136 clarified suspensions of diarrhoeal faeces by the staphylococcal co-agglutination test revealed a high proportion of false positives (26%) and uninterpretable results (34%) due to non-specific agglutination. Non-specific agglutination could be removed effectively by prior absorption of the clarified faecal specimens with unsensitized staphylococci. The staphylococcal co-agglutination test was less sensitive and specific than the in-house enzyme-linked immunosorbent assay but was comparable to the Rotalex slide latex agglutination test. The staphylococcal reagents have a shelf life of at least 29 weeks.
    Matched MeSH terms: Sensitivity and Specificity
  17. Francis A, Aiyar S, Yean CY, Naing L, Ravichandran M
    Diagn Microbiol Infect Dis, 2006 Jun;55(2):95-9.
    PMID: 16626918
    Isolation and culture of Burkholderia pseudomallei remains the main stay in the diagnosis of melioidosis. Thus, the search for selective and differential media for B. pseudomallei has been ongoing. A number of such media have been reported with varying efficacy. Ashdown medium is the most established selective medium for the isolation of B. pseudomallei. There are no reports of differential media differentiating B. pseudomallei from Burkholderia cepacia. This report documents such a selective and differentiating medium for B. pseudomallei. Of a total of 1042 clinical specimens containing mixed flora and gram-negative isolates that were tested on this medium, 16 of the specimens yielded B. pseudomallei. The isolation rate was found to be 1.5%. This medium was found to be simple and inexpensive, can be made by small laboratories, and called as Francis medium. Based on the colony morphology and color, a preliminary report can be made within 18-24 h for the presence of B. pseudomallei. Our study showed that this medium had an overall sensitivity of 78.4% with a specificity of 92.2%. The use of this medium as an early diagnostic tool will help to reduce mortality and morbidity of melioidosis patients.
    Matched MeSH terms: Sensitivity and Specificity
  18. Salleh FM, Moktar N, Yasin AM, Al-Mekhlafi HM, Anuar TS
    J Microbiol Methods, 2014 Nov;106:143-145.
    PMID: 25193442 DOI: 10.1016/j.mimet.2014.08.019
    To improve the stool concentration procedure, we modified different steps of the standard formalin-ether concentration technique and evaluated these modifications by examining stool samples collected in the field. Seven samples were found positive by the modified formalin-ether concentration technique (M-FECT). Therefore, the M-FECT procedure provides enhanced detection of Cryptosporidium oocysts.
    Matched MeSH terms: Sensitivity and Specificity
  19. Abdullah BJ, Kaur H, Ng KH
    Br J Radiol, 1998 Sep;71(849):930-3.
    PMID: 10195007
    Dried fish bones from eight species of Malaysian fish were placed in an animal cadaver at four sites (tonsil, valleculae, larynx and oesophagus) and radiographed using a double and a single film-screen combination. The use of the single film-screen combination resulted in visibility of all fish bones placed in the larynx, two of which were not visible on the double film-screen combination. There was a 50% increase of the visibility of the fish bones in the oesophagus using the single film-screen combination. The difference in dose and cost between the two different film-screen combinations was not significant.
    Matched MeSH terms: Sensitivity and Specificity
  20. Tay SP, Cheong SK
    Malays J Pathol, 2002 Jun;24(1):45-51.
    PMID: 16329555
    Tissue Factor (TF) is a low molecular weight transmembrane glycoprotein that initiates the clotting protease cascade. It is considered to be the principal regulator of the extrinsic coagulation pathway, hemostasis and thrombosis, as well as inflammation and cellular immune response. An in-house two-step direct sandwich ELISA (enzyme-linked immunosorbent assay) for immunological quantification of plasma TF was successfully developed. The assay employed a monoclonal antibody against human TF (1:400 dilution; 1250 ng/ml) and peroxidase-conjugated anti-TF IgG (1:1000 dilution; 2000 ng/ml) as capture and detecting antibodies respectively, whilst tetramethylbenzidine/H2O2 were utilized as substrates. Titration curves of recombinant TF were linear within 10 to 4000 pg/ml, with a detection limit of 36.31 pg/ml. It demonstrated low intra- (2.50 - 9.23 CV%) and inter-assays (5.65 - 13.57 CV%) variability, as well as satisfactory analytical recovery (91.55 - 103.95%) and good parallelism. The assay developed was intended to be applied for measurement of plasma TF levels in patients with thrombotic disorders.
    Matched MeSH terms: Sensitivity and Specificity