MATERIALS AND METHODS: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day).
RESULTS: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events.
CONCLUSIONS: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.
STUDY DESIGN: Diagnostic cross-sectional study.
METHODS: This study included consecutive CRS patients without prior sinus surgery. Computed tomography (CT) scans of the paranasal sinuses were blindly assessed and allergy status was confirmed by serum or skin testing. Individual sinus cavities were defined as either centrally limited or diffuse disease. The radiological pattern that may predict allergy was determined, and its diagnostic accuracy was calculated.
RESULTS: One hundred twelve patients diagnosed to have CRS, representing 224 sides, were assessed (age 46.31 ± 13.57 years, 38.39% female, 41.07% asthma, Lund-Mackay CT score 15.88 ± 4.35, 56.25% atopic). The radiological pattern defined by centrally limited changes in all of the paranasal sinuses was associated with allergy status (73.53% vs. 53.16%, P = .03). This predicted atopy with 90.82% specificity, 73.53% positive predictive value, likelihood positive ratios of 2.16, and diagnostic odds ratio of 4.59.
CONCLUSIONS: A central radiological pattern of mucosal disease is associated with inhalant allergen sensitization. This group may represent a CCAD subgroup of patients with mainly allergic etiology.
LEVEL OF EVIDENCE: 3b Laryngoscope, 128:2015-2021, 2018.
METHODS: An indirect enzyme-linked immunosorbent assay (ELISA) was developed to evaluate the usefulness of USM.TOXO1 antigen for the detection of IgG antibodies against Toxoplasma gondii in human sera. Whereas the reactivity of the developed antigen against IgM antibody was evaluated by western blot and Dot enzyme immunoassay (dot-EIA) analysis.
RESULTS: The diagnostic performance of the new antigens in IgG ELISA was achieved at the maximum values of 85.43% and 81.25% for diagnostic sensitivity and specificity respectively. The USM.TOXO1 was also proven to be reactive with anti- T. gondii IgM antibody.
CONCLUSIONS: This finding makes the USM.TOXO1 antigen an attractive candidate for improving the toxoplasmosis serodiagnosis and demonstrates that multiepitope antigens could be a potential and promising diagnostic marker for the development of high sensitive and accurate assays.