Displaying publications 81 - 100 of 100 in total

Abstract:
Sort:
  1. Wong, Y.W.E., Abdullah, N.
    Malaysian Family Physician, 2018;13(2):42-44.
    MyJurnal
    Purple urine bag syndrome (PUBs) is a rare and startling phenomenon of purple discolouration
    in the urine or urinary catheter and bag. It is reported in chronically debilitated elderly patients,
    mostly in women on long-term urinary catheters. Its prevalence is strikingly more common in
    nursing home residents. Several factors contribute to the formation of indigo (blue) and indirubin
    (red) pigments from a breakdown of dietary tryptophan, which stains the urine purple. These
    factors include constipation, dysmotility of the bowel, bowel bacterial overgrowth, dehydration, and
    urinary tract infection. The presence of purple urine may cause undue alarm to both the patient and
    the doctor. Thus, we present this case report on an 86-year-old woman, a nursing home resident
    on a long-term urinary catheter, who presented to the primary care clinic. Her urine cleared
    after antibiotic therapy, replacement of her urinary catheter, and supportive management, which
    included hydration and nutrition. In addition to these measures, reducing the time between urinary
    catheter changes was recommended to prevent recurrence of this condition.
    Matched MeSH terms: Urinary Catheters
  2. Grace Ng YH, Aminuddin AA, Tan TL, Kuppusamy R, Tagore S, Yeo GSH
    Arch Gynecol Obstet, 2021 May 11.
    PMID: 33973051 DOI: 10.1007/s00404-021-06090-y
    OBJECTIVE: To evaluate the safety in the first 12 h, efficacy and maternal satisfaction of a double balloon catheter (DBC) with vaginal prostaglandin (PGE) for induction of labour (IOL).

    METHODS: We conducted a multicentre randomised controlled study of 420 patients from 1st January 2016 to 31st December 2017 to evaluate the use of DBC in IOL in an Asian population looking at the adverse effects in the first 12 h after insertion. Women were assigned randomly to cervical ripening with either a DBC or a prostaglandin pessary. The adverse events in the 12 h after DBC or first prostaglandin inserted, the efficacy of a DBC to a prostaglandin in labour induction and maternal satisfaction were evaluated.

    RESULTS: There were significantly less women with uterine hyperstimulation in the DBC (2 vs 24, p ≤ 0.0001) compared to the prostaglandin group. There were no women with uterine hyperstimulation and non-reassuring foetal status in the DBC while there were 5 women with uterine hyperstimulation and foetal distress in the prostaglandin group. Use of entonox was significantly less in the DBC group (p = 0.009). There were no significant differences in both groups in caesarean section, vaginal deliveries and time to delivery, although significant less time was needed to achieve cervical os dilation more than 4 cm in the DBC group (p ≤ 0.0001). Neonatal birth outcomes were similar. Women's pain scores were similar for both methods. 80.1% of women allocated the DBC and 76.8% of women allocated the PGE were keen to recommend their method of induction.

    CONCLUSION: Double balloon catheter remains a good alternative method for inducing women in view of a good safety profile with low risk of hyperstimulation and high maternal satisfaction.

    CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02620215.

    Matched MeSH terms: Catheters
  3. Chuah JS, Wong WL, Bakin S, Lim RZM, Lee EP, Tan JH
    Ann Med Surg (Lond), 2021 May;65:102294.
    PMID: 33948169 DOI: 10.1016/j.amsu.2021.102294
    Introduction and importance: A totally implantable venous access device (TIVAD), also referred to as 'chemoport', is frequently used for oncology patients. Chemoport insertion via the subclavian vein access may compress the catheter between the first rib and the clavicle, resulting in pinch-off syndrome (POS). The sequela includes catheter transection and subsequent embolization. It is a rare complication with incidence reported to be 1.1-5.0% and can lead to a devastating outcomes.

    Case presentation: 50-year-old male had his chemoport inserted for adjuvant chemotherapy 3 years ago. During the removal, remaining half of the distal catheter was not found. There was no difficulties during the removal. Chest xray revealed that the fractured catheter had embolized to the right ventricle. Further history taking, he did experienced occasional palpitation and chest discomfort for the past six months. Electrocardiogram and cardiac enzymes were normal. Urgent removal of the fractured catheter via the percutaneous endovascular approach, under fluoroscopic guidance by an experience interventional radiologist was done. The procedure was successful without any complication. Patient made an uneventful recovery. He was discharged the following day, and was well during his 3rd month follow up.

    Conclusion: Early detection and preventive measures can be done to prevent pinch-off syndrome. Unrecognized POS can result in fatal complications such as cardiac arrhythmia and septic embolization. Retrieval via the percutaneous endovascular approach provide excellent outcome in the case of embolized fractured catheter.

    Matched MeSH terms: Catheters
  4. Chia HM, Tan PC, Tan SP, Hamdan M, Omar SZ
    BMC Pregnancy Childbirth, 2020 May 29;20(1):330.
    PMID: 32471369 DOI: 10.1186/s12884-020-03029-0
    BACKGROUND: Induction of labor (IoL) is an increasingly common obstetric procedure. Foley catheter IoL is recommended by WHO. It is associated with the lowest rate of uterine hyperstimulation syndrome and similar duration to delivery and vaginal delivery rate compared to other methods. Insertion is typically via speculum but digital insertion has been reported to be faster, better tolerated and with similar universal insertion success compared to speculum insertion in a mixed population of nulliparas and multiparas. Transcervical procedure is more challenging in nulliparas and when the cervix is unripe. We evaluated the ease and tolerability of digital compared to speculum insertion of Foley catheter for induction of labor in nulliparas with unripe cervixes.

    METHODS: A randomized trial was performed in a university hospital in Malaysia. Participants were nulliparas at term with unripe cervixes (Bishop Score ≤ 5) admitted for IoL who were randomized to digital or speculum-aided transcervical Foley catheter insertion in lithotomy position. Primary outcomes were insertion duration, pain score [11-point Visual Numerical Rating Scale (VNRS)], and failure. All primary outcomes were recorded after the first insertion.

    RESULTS: Data from 86 participants were analysed. Insertion duration (with standard deviation) was 2.72 ± 1.85 vs. 2.25 ± 0.55 min p = 0.12, pain score (VNRS) median [interquartile range] 3.5 [2-5] vs. 3 [2-5] p = 0.72 and failure 2/42 (5%) vs. 0/44 (0%) p = 0.24 for digital vs speculum respectively. There was no significant difference found between the two groups for all three primary outcomes. Induction to delivery 30.7 ± 9.4 vs 29.6 ± 11.5 h p = 0.64, Cesarean section 25/60 (64%) vs 28/64 (60%) RR 0.9 95% CI p = 0.7 and maternal satisfaction VNRS score with the birth process 7 [IQR 6-8] vs 7 [7-8] p = 0.97 for digital vs. speculum arms respectively. Other labor, delivery and neonatal secondary outcomes were not significantly different.

    CONCLUSION: Digital and speculum insertion in nulliparas with unripe cervixes had similar insertion performance. As digital insertion required less equipment and consumables, it could be the preferred insertion method for the equally adept and the insertion technique to train towards.

    TRIAL REGISTRATION: This trial was registered with ISRCTN registration number 13804902 on 15 November 2017.

    Matched MeSH terms: Urinary Catheters
  5. Croci DM, Dalolio M, Aghlmandi S, Taub E, Rychen J, Chiappini A, et al.
    Neurol Res, 2021 Jan;43(1):40-53.
    PMID: 33106124 DOI: 10.1080/01616412.2020.1819091
    Objective: Early permanent cerebrospinal fluid (CSF) diversion for hydrocephalus during the first 2 weeks after aneurysmal subarachnoid hemorrhage (aSAH) shortens the duration of external ventricular drainage (EVD) and reduces EVD-associated infections (EVDAI). The objective of this study was to detect any association with symptomatic delayed cerebral vasospasm (DCVS), or delayed cerebral ischemia (DCI) by the time of hospital discharge. Methods: We used a single-center dataset of aSAH patients who had received a permanent CSF diversion. We compared an 'early group' in which the procedure was performed up to 14 days after the ictus, to a 'late group' in which it was performed from the 15th day onward. Results: Among 274 consecutive aSAH patients, 39 (14%) had a permanent CSF diversion procedure with a silver-coated EVD. While the blood clot burden was similarly distributed, patients with early permanent CSF diversion (20 out of 39; 51%) had higher levels of consciousness on admission. Early permanent CSF diversion was associated with less colonized catheter, a shorter duration of extracorporeal CSF diversion (OR 0.73, 95%CI 0.58-0.92 per EVD day), and a lower rate of EVDAI (OR 0.08, 95%CI 0.01-0.80). The occurrence of CSF diversion device obstruction, the rate of symptomatic DCVS or detected DCI on computed tomography and the likelihood of a poor outcome at discharge did not differ between the two groups. Discussion: Early permanent CSF diversion lowers the occurrence of catheter colonization and infectious complication without affecting DCVS-related morbidity in good-grade aSAH patients. These findings need confirmation in larger prospective multicenter cohorts. Abbreviations: aSAH: aneurysmal subarachnoid hemorrhage; BNI: Barrow Neurological Institute Scale; CSF: Cerebrospinal fluid; DCVS: Delayed Cerebral Vasospasm; DCI: Delayed Cortical Ischemia; EKNZ: Ethik-Kommission Nordwest Schweiz; EVD: External ventricular drain; EVDAI: External ventricular drain-associated infections; GCS: Glasgow Coma Scale; IRB: Institutional Review Board; IVH: Inraventricular hemorrhage; mRS: Modified Rankin Scale; SOS: Swiss Study of Subarachnoid Hemorrhage Registry; WFNS: World Federation Neurological-Surgeon Scale.
    Matched MeSH terms: Catheters
  6. Nusee, Z., Naidu, A., Ranjudham, S.N., Ismail, H.
    JUMMEC, 2011;14(1):10-20.
    MyJurnal
    The use of transobturator tape (TOT) for the treatment of stress urinary incontinence (SUI) has gained popularity since it was introduced in 2001. Only few studies have reported that TOT is superior in safety and efficacy when compared to tension free vaginal tape (TVT). This case-series study was conducted to investigate the safety and efficacy of the TOT procedure in patients at Ipoh Hospital. A cross sectional study on patients who underwent TOT procedures from Jan 2006 to Jun 2008 was conducted. Patients were followed-up 1 month, 3 month, 12 month and annually thereafter. Data were retrieved from patients‟ records based on the standard pre-operative assessment sheet and follow up record. Interviews were then made via telecommunication to assess the patients‟ progression and satisfaction using a validated questionnaire. Fifty-two subjects (n=52) were recruited. The mean age was 54.2 ± 10.6 years with the median follow up time of 19 months. Majority of cases (n=46; 88.5%) had concomitant pelvic organ prolapse (POP), while only 2 (3.8%) had an isolated stress urinary incontinence (SUI). Pre-operatively, only 16 patients (30.8%) were diagnosed with mixed urinary incontinence (MUI) and 24 patients (46.2%) had over active bladder symptoms (OAB) which include increased frequency and urgency. The objective cure rate for SUI was 42 (80.7%), 3 (5.8%) failed while 7 (13.5%) improved. Complications were limited to minor conditions and was only observed in four patients: one case (1.9%) of acute urinary retention, three (5.7%) had prolonged indwelling catheter more than 3 days and one (1.9%) each for mesh erosion, hematoma, urinary tract infection (UTI) and wound infection. Cure rate for MUI, frequency and urgency were 37.4%, 70.8% and 54.2% respectively. De novo urgency was noted in three (n=3: 5.7%) cases while (n=3: 5.7%) required revision of the tape. Forty-nine women (n=49: 94.2%) were satisfied with the procedure. TOT procedures significantly improve OAB symptoms with high patient‟s acceptance rate and no serious operative complication.
    Matched MeSH terms: Catheters, Indwelling
  7. Piccini JP, Stromberg K, Jackson KP, Laager V, Duray GZ, El-Chami M, et al.
    Heart Rhythm, 2017 05;14(5):685-691.
    PMID: 28111349 DOI: 10.1016/j.hrthm.2017.01.026
    BACKGROUND: Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds.

    OBJECTIVE: The purpose of this study was to describe the natural history of acute elevated Micra vs traditional transvenous lead thresholds.

    METHODS: Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0-6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test.

    RESULTS: Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V.

    CONCLUSIONS: Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.

    Matched MeSH terms: Cardiac Catheters
  8. Duray GZ, Ritter P, El-Chami M, Narasimhan C, Omar R, Tolosana JM, et al.
    Heart Rhythm, 2017 05;14(5):702-709.
    PMID: 28192207 DOI: 10.1016/j.hrthm.2017.01.035
    BACKGROUND: Early performance of the Micra transcatheter pacemaker from the global clinical trial reported a 99.2% implant success rate, low and stable pacing capture thresholds, and a low (4.0%) rate of major complications up to 6 months.

    OBJECTIVE: The purpose of this report was to describe the prespecified long-term safety objective of Micra at 12 months and electrical performance through 24 months.

    METHODS: The Micra Transcatheter Pacing Study was a prospective single-arm study designed to assess the safety and efficacy of the Micra VVIR leadless/intracardiac pacemaker. Enrolled patients met class I or II guideline recommendations for de novo ventricular pacing. The long-term safety objective was freedom from a system- or procedure-related major complication at 12 months. A predefined historical control group of 2667 patients with transvenous pacemakers was used to compare major complication rates.

    RESULTS: The long-term safety objective was achieved with a freedom from major complication rate of 96.0% at 12 months (95% confidence interval 94.2%-97.2%; P < .0001 vs performance goal). The risk of major complications for patients with Micra (N = 726) was 48% lower than that for patients with transvenous systems through 12 months postimplant (hazard ratio 0.52; 95% confidence interval 0.35-0.77; P = .001). Across subgroups of age, sex, and comorbidities, Micra reduced the risk of major complications compared to transvenous systems. Electrical performance was excellent through 24 months, with a projected battery longevity of 12.1 years.

    CONCLUSION: Long-term performance of the Micra transcatheter pacemaker remains consistent with previously reported data. Few patients experienced major complications through 12 months of follow-up, and all patient subgroups benefited as compared to transvenous pacemaker historical control group.

    Matched MeSH terms: Cardiac Catheters
  9. Wong Y, Abdullah N
    Malays Fam Physician, 2018;13(2):42-44.
    PMID: 30302185
    Purple urine bag syndrome (PUBs) is a rare and startling phenomenon of purple discolouration in the urine or urinary catheter and bag. It is reported in chronically debilitated elderly patients, mostly in women on long-term urinary catheters. Its prevalence is strikingly more common in nursing home residents. Several factors contribute to the formation of indigo (blue) and indirubin (red) pigments from a breakdown of dietary tryptophan, which stains the urine purple. These factors include constipation, dysmotility of the bowel, bowel bacterial overgrowth, dehydration, and urinary tract infection. The presence of purple urine may cause undue alarm to both the patient and the doctor. Thus, we present this case report on an 86-year-old woman, a nursing home resident on a long-term urinary catheter, who presented to the primary care clinic. Her urine cleared after antibiotic therapy, replacement of her urinary catheter, and supportive management, which included hydration and nutrition. In addition to these measures, reducing the time between urinary catheter changes was recommended to prevent recurrence of this condition.
    Matched MeSH terms: Urinary Catheters
  10. Liu WJ, Hooi LS
    Perit Dial Int, 2010 03 12;30(5):509-12.
    PMID: 20228175 DOI: 10.3747/pdi.2009.00083
    OBJECTIVE: To analyze the complications after Tenckhoff catheter insertion among patients with renal failure needing dialysis. ♢

    PATIENTS AND METHODS: The open, paramedian approach is the commonest technique to insert the 62-cm coiled double-cuffed Tenckhoff peritoneal catheter. All patients with catheters inserted between January 2004 and November 2007 were retrospectively analyzed for demographics and followed for up to 1 month for complications. We excluded patients whose catheters had been anchored to the bladder wall and who underwent concurrent omentectomy or readjustment without removal of a malfunctioning catheter (n = 7). Intravenous cloxacillin was the standard preoperative antibiotic prophylaxis. ♢

    RESULTS: Over the 4-year study period, 384 catheters were inserted under local anesthetic into 319 patients [201 women (62.8%); mean age: 49.4 ± 16.7 years (range: 13 - 89 years); 167 (52.2%) with diabetes; 303 (95%) with end-stage renal disease] by 22 different operators. All Tenckhoff catheters were inserted by the general surgical (n = 223) or urology (n = 161) team. There were 29 cases (7.6%) of catheter migration, 22 (5.7%) of catheter obstruction without migration, 24 (6.3%) of exit-site infection, 12 (3.1%) of leak from the main incision, 14 (3.6%) of culture-proven wound infection, 11 (2.9%) post-insertion peritonitis, and 1 (0.3%) hemoperitoneum. No deaths were attributed to surgical mishap. ♢

    CONCLUSIONS: The most common complication was catheter migration. The paramedian insertion technique was safe, with low complication rates.

    Matched MeSH terms: Catheters, Indwelling/adverse effects*
  11. Lai NM, Taylor JE, Tan K, Choo YM, Ahmad Kamar A, Muhamad NA
    Cochrane Database Syst Rev, 2016 Mar 23;3:CD011082.
    PMID: 27007217 DOI: 10.1002/14651858.CD011082.pub2
    BACKGROUND: Central venous catheters (CVCs) provide secured venous access in neonates. Antimicrobial dressings applied over the CVC sites have been proposed to reduce catheter-related blood stream infection (CRBSI) by decreasing colonisation. However, there may be concerns on the local and systemic adverse effects of these dressings in neonates.

    OBJECTIVES: We assessed the effectiveness and safety of antimicrobial (antiseptic or antibiotic) dressings in reducing CVC-related infections in newborn infants. Had there been relevant data, we would have evaluated the effects of antimicrobial dressings in different subgroups, including infants who received different types of CVCs, infants who required CVC for different durations, infants with CVCs with and without other antimicrobial modifications, and infants who received an antimicrobial dressing with and without a clearly defined co-intervention.

    SEARCH METHODS: We used the standard search strategy of the Cochrane Neonatal Review Group (CNRG). We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library 2015, Issue 9), MEDLINE (PubMed), EMBASE (EBCHOST), CINAHL and references cited in our short-listed articles using keywords and MeSH headings, up to September 2015.

    SELECTION CRITERIA: We included randomised controlled trials that compared an antimicrobial CVC dressing against no dressing or another dressing in newborn infants.

    DATA COLLECTION AND ANALYSIS: We extracted data using the standard methods of the CNRG. Two review authors independently assessed the eligibility and risk of bias of the retrieved records. We expressed our results using risk difference (RD) and risk ratio (RR) with 95% confidence intervals (CIs).

    MAIN RESULTS: Out of 173 articles screened, three studies were included. There were two comparisons: chlorhexidine dressing following alcohol cleansing versus polyurethane dressing following povidone-iodine cleansing (one study); and silver-alginate patch versus control (two studies). A total of 855 infants from level III neonatal intensive care units (NICUs) were evaluated, 705 of whom were from a single study. All studies were at high risk of bias for blinding of care personnel or unclear risk of bias for blinding of outcome assessors. There was moderate-quality evidence for all major outcomes.The single study comparing chlorhexidine dressing/alcohol cleansing against polyurethane dressing/povidone-iodine cleansing showed no significant difference in the risk of CRBSI (RR 1.18, 95% CI 0.53 to 2.65; RD 0.01, 95% CI -0.02 to 0.03; 655 infants, moderate-quality evidence) and sepsis without a source (RR 1.06, 95% CI 0.75 to 1.52; RD 0.01, 95% CI -0.04 to 0.06; 705 infants, moderate-quality evidence). There was a significant reduction in the risk of catheter colonisation favouring chlorhexidine dressing/alcohol cleansing group (RR 0.62, 95% CI 0.45 to 0.86; RD -0.09, 95% CI -0.15 to -0.03; number needed to treat for an additional beneficial outcome (NNTB) 11, 95% CI 7 to 33; 655 infants, moderate-quality evidence). However, infants in the chlorhexidine dressing/alcohol cleansing group were significantly more likely to develop contact dermatitis, with 19 infants in the chlorhexidine dressing/alcohol cleansing group having developed contact dermatitis compared to none in the polyurethane dressing/povidone-iodine cleansing group (RR 43.06, 95% CI 2.61 to 710.44; RD 0.06, 95% CI 0.03 to 0.08; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 13 to 33; 705 infants, moderate-quality evidence). The roles of chlorhexidine dressing in the outcomes reported were unclear, as the two assigned groups received different co-interventions in the form of different skin cleansing agents prior to catheter insertion and during each dressing change.In the other comparison, silver-alginate patch versus control, the data for CRBSI were analysed separately in two subgroups as the two included studies reported the outcome using different denominators: one using infants and another using catheters. There were no significant differences between infants who received silver-alginate patch against infants who received standard line dressing in CRBSI, whether expressed as the number of infants (RR 0.50, 95% CI 0.14 to 1.78; RD -0.12, 95% CI -0.33 to 0.09; 1 study, 50 participants, moderate-quality evidence) or as the number of catheters (RR 0.72, 95% CI 0.27 to 1.89; RD -0.05, 95% CI -0.20 to 0.10; 1 study, 118 participants, moderate-quality evidence). There was also no significant difference between the two groups in mortality (RR 0.55, 95% CI 0.15 to 2.05; RD -0.04, 95% CI -0.13 to 0.05; two studies, 150 infants, I² = 0%, moderate-quality evidence). No adverse skin reaction was recorded in either group.

    AUTHORS' CONCLUSIONS: Based on moderate-quality evidence, chlorhexidine dressing/alcohol skin cleansing reduced catheter colonisation, but made no significant difference in major outcomes like sepsis and CRBSI compared to polyurethane dressing/povidone-iodine cleansing. Chlorhexidine dressing/alcohol cleansing posed a substantial risk of contact dermatitis in preterm infants, although it was unclear whether this was contributed mainly by the dressing material or the cleansing agent. While silver-alginate patch appeared safe, evidence is still insufficient for a recommendation in practice. Future research that evaluates antimicrobial dressing should ensure blinding of caregivers and outcome assessors and ensure that all participants receive the same co-interventions, such as the skin cleansing agent. Major outcomes like sepsis, CRBSI and mortality should be assessed in infants of different gestation and birth weight.

    Matched MeSH terms: Central Venous Catheters/adverse effects*
  12. Viecelli AK, Pascoe E, Polkinghorne KR, Hawley C, Paul-Brent PA, Badve SV, et al.
    BMC Nephrol, 2015;16:89.
    PMID: 26116581 DOI: 10.1186/s12882-015-0089-2
    The FAVOURED study is an international multicentre, double-blind, placebo-controlled trial which commenced recruitment in 2008 and examines whether omega-3 polyunsaturated fatty acids (omega-3 PUFAs) either alone or in combination with aspirin will effectively reduce primary access failure of de novo arteriovenous fistulae (AVF) in patients with stage 4 and 5 chronic kidney disease. Publication of new evidence derived from additional studies of clopidogrel and a high screen failure rate due to prevalent aspirin usage prompted an updated trial design.
    Matched MeSH terms: Central Venous Catheters/utilization
  13. Shahrudin MD, Noori SM
    Hepatogastroenterology, 1997 Mar-Apr;44(14):559-63.
    PMID: 9164537
    Total parenteral nutrition (TPN) for the non-operative treatment of acute pancreatic pseudocyst has been of hypothetical benefit.
    Matched MeSH terms: Catheters, Indwelling/adverse effects
  14. Shanmuganathan M, Goh BL, Lim C, NorFadhlina Z, Fairol I
    Perit Dial Int, 2016 9 24;36(5):574-5.
    PMID: 27659933 DOI: 10.3747/pdi.2015.00287
    Patients with peritonitis present with abdominal pain, diarrhea, fever, and turbid peritoneal dialysis (PD) fluid. Shewanella algae peritonitis has not yet been reported in PD patients in the literature. We present the first 2 cases of Shewanella algae peritonitis in PD patients. Mupirocin cream is applied on the exit site as prophylactic antibiotic therapy.
    Matched MeSH terms: Catheters, Indwelling/microbiology*
  15. Chong HY, Lai NM, Apisarnthanarak A, Chaiyakunapruk N
    Clin Infect Dis, 2017 May 15;64(suppl_2):S131-S140.
    PMID: 28475779 DOI: 10.1093/cid/cix019
    Background: The efficacy of antimicrobial central venous catheters (CVCs) remains questionable. In this network meta-analysis, we aimed to assess the comparative efficacy of antimicrobial CVC impregnations in reducing catheter-related infections in adults.

    Methods: We searched 4 electronic databases (Medline, the Cochrane Central Register of Controlled Trials, Embase, CINAHL) and internet sources for randomized controlled trials, ongoing clinical trials, and unpublished studies up to August 2016. Studies that assessed CVCs with antimicrobial impregnation with nonimpregnated catheters or catheters with another impregnation were included. Primary outcomes were clinically diagnosed sepsis, catheter-related bloodstream infection (CRBSI), and all-cause mortality. We performed a network meta-analysis to estimate risk ratio (RR) with 95% confidence interval (CI).

    Results: Sixty studies with 17255 catheters were included. The effects of 14 impregnations were investigated. Both CRBSI and catheter colonization were the most commonly evaluated outcomes. Silver-impregnated CVCs significantly reduced clinically diagnosed sepsis compared with silver-impregnated cuffs (RR, 0.54 [95% CI, .29-.99]). When compared to no impregnation, significant CRBSI reduction was associated with minocycline-rifampicin (RR, 0.29 [95% CI, .16-.52]) and silver (RR, 0.57 [95% CI, .38-.86]) impregnations. No impregnations significantly reduced all-cause mortality. For catheter colonization, significant decreases were shown by miconazole-rifampicin (RR, 0.14 [95% CI, .05-.36]), 5-fluorouracil (RR, 0.34 [95% CI, .14-.82]), and chlorhexidine-silver sulfadiazine (RR, 0.60 [95% CI, .50-.72]) impregnations compared with no impregnation. None of the studies evaluated antibiotic/antiseptic resistance as the outcome.

    Conclusions: Current evidence suggests that the minocycline-rifampicin-impregnated CVC appears to be the most effective in preventing CRBSI. However, its overall benefits in reducing clinical sepsis and mortality remain uncertain. Surveillance for antibiotic resistance attributed to the routine use of antimicrobial-impregnated CVCs should be emphasized in future trials.

    Matched MeSH terms: Central Venous Catheters*
  16. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Cardiac Catheters*
  17. Rosenthal VD, Bat-Erdene I, Gupta D, Belkebir S, Rajhans P, Zand F, et al.
    Infect Control Hosp Epidemiol, 2020 05;41(5):553-563.
    PMID: 32183925 DOI: 10.1017/ice.2020.20
    BACKGROUND: Short-term peripheral venous catheter-related bloodstream infection (PVCR-BSI) rates have not been systematically studied in resource-limited countries, and data on their incidence by number of device days are not available.

    METHODS: Prospective, surveillance study on PVCR-BSI conducted from September 1, 2013, to May 31, 2019, in 727 intensive care units (ICUs), by members of the International Nosocomial Infection Control Consortium (INICC), from 268 hospitals in 141 cities of 42 countries of Africa, the Americas, Eastern Mediterranean, Europe, South East Asia, and Western Pacific regions. For this research, we applied definition and criteria of the CDC NHSN, methodology of the INICC, and software named INICC Surveillance Online System.

    RESULTS: We followed 149,609 ICU patients for 731,135 bed days and 743,508 short-term peripheral venous catheter (PVC) days. We identified 1,789 PVCR-BSIs for an overall rate of 2.41 per 1,000 PVC days. Mortality in patients with PVC but without PVCR-BSI was 6.67%, and mortality was 18% in patients with PVC and PVCR-BSI. The length of stay of patients with PVC but without PVCR-BSI was 4.83 days, and the length of stay was 9.85 days in patients with PVC and PVCR-BSI. Among these infections, the microorganism profile showed 58% gram-negative bacteria: Escherichia coli (16%), Klebsiella spp (11%), Pseudomonas aeruginosa (6%), Enterobacter spp (4%), and others (20%) including Serratia marcescens. Staphylococcus aureus were the predominant gram-positive bacteria (12%).

    CONCLUSIONS: PVCR-BSI rates in INICC ICUs were much higher than rates published from industrialized countries. Infection prevention programs must be implemented to reduce the incidence of PVCR-BSIs in resource-limited countries.

    Matched MeSH terms: Catheters
  18. Seak CJ, Lim MWX, Seak JC, Goh ZNL, Seak CK
    QJM, 2020 06 01;113(6):434-435.
    PMID: 31816086 DOI: 10.1093/qjmed/hcz314
    Matched MeSH terms: Catheters, Indwelling
  19. Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, et al.
    Heart Rhythm, 2017 02;14(2):200-205.
    PMID: 27871854 DOI: 10.1016/j.hrthm.2016.11.016
    BACKGROUND: The Micra transcatheter pacemaker was designed to have similar functionality to conventional transvenous VVIR pacing systems. It provides rate adaptive pacing using a programmable 3-axis accelerometer designed to detect patient activity in the presence of cardiac motion.

    OBJECTIVE: The purpose of this study was to evaluate the system's performance during treadmill tests to maximum exertion in a subset of patients within the Micra Transcatheter Pacing Study.

    METHODS: Patients underwent treadmill testing at 3 or 6 months postimplant with algorithm programming at physician discretion. Normalized sensor rate (SenR) relative to the programmed upper sensor rate was modeled as a function of normalized workload in metabolic equivalents (METS) relative to maximum METS achieved during the test. A normalized METS and SenR were determined at the end of each 1-minute treadmill stage. The proportionality of SenR to workload was evaluated by comparing the slope from this relationship to the prospectively defined tolerance margin (0.65-1.35).

    RESULTS: A total of 69 treadmill tests were attempted by 42 patients at 3 and 6 months postimplant. Thirty tests from 20 patients who completed ≥4 stages with an average slope of 0.86 (90% confidence interval 0.77-0.96) confirmed proportionality to workload. On an individual test basis, 25 of 30 point estimates (83.3%) had a normalized slope within the defined tolerance range (range 0.46-1.08).

    CONCLUSION: Accelerometer-based rate adaptive pacing was proportional to workload, thus confirming rate adaptive pacing commensurate to workload is achievable with an entirely intracardiac pacing system.

    Matched MeSH terms: Cardiac Catheters
Filters