Displaying publications 81 - 100 of 191 in total

Abstract:
Sort:
  1. Jeong J
    Sensors (Basel), 2011;11(7):6816-41.
    PMID: 22163987 DOI: 10.3390/s110706816
    This paper presents an acoustic noise cancelling technique using an inverse kepstrum system as an innovations-based whitening application for an adaptive finite impulse response (FIR) filter in beamforming structure. The inverse kepstrum method uses an innovations-whitened form from one acoustic path transfer function between a reference microphone sensor and a noise source so that the rear-end reference signal will then be a whitened sequence to a cascaded adaptive FIR filter in the beamforming structure. By using an inverse kepstrum filter as a whitening filter with the use of a delay filter, the cascaded adaptive FIR filter estimates only the numerator of the polynomial part from the ratio of overall combined transfer functions. The test results have shown that the adaptive FIR filter is more effective in beamforming structure than an adaptive noise cancelling (ANC) structure in terms of signal distortion in the desired signal and noise reduction in noise with nonminimum phase components. In addition, the inverse kepstrum method shows almost the same convergence level in estimate of noise statistics with the use of a smaller amount of adaptive FIR filter weights than the kepstrum method, hence it could provide better computational simplicity in processing. Furthermore, the rear-end inverse kepstrum method in beamforming structure has shown less signal distortion in the desired signal than the front-end kepstrum method and the front-end inverse kepstrum method in beamforming structure.
    Matched MeSH terms: Noise*
  2. Kamaruddin NH, Bakar AAA, Mobarak NN, Zan MSD, Arsad N
    Sensors (Basel), 2017 Oct 06;17(10).
    PMID: 28984826 DOI: 10.3390/s17102277
    The study of binding affinity is essential in surface plasmon resonance (SPR) sensing because it allows researchers to quantify the affinity between the analyte and immobilised ligands of an SPR sensor. In this study, we demonstrate the derivation of the binding affinity constant, K, for Pb2+and Hg2+ions according to their SPR response using a gold/silver/gold/chitosan-graphene oxide (Au/Ag/Au/CS-GO) sensor for the concentration range of 0.1-5 ppm. The higher affinity of Pb2+to binding with the CS-GO sensor explains the outstanding sensitivity of 2.05 °ppm-1against 1.66 °ppm-1of Hg2+. The maximum signal-to-noise ratio (SNR) upon detection of Pb2+is 1.53, and exceeds the suggested logical criterion of an SNR. The Au/Ag/Au/CS-GO SPR sensor also exhibits excellent repeatability in Pb2+due to the strong bond between its functional groups and this cation. The adsorption data of Pb2+and Hg2+on the CS-GO sensor fits well with the Langmuir isotherm model where the affinity constant, K, of Pb2+and Hg2+ions is computed. The affinity of Pb2+ions to the Au/Ag/Au/CS-GO sensor is significantly higher than that of Hg2+based on the value of K, 7 × 10⁵ M-1and 4 × 10⁵ M-1, respectively. The higher shift in SPR angles due to Pb2+and Hg2+compared to Cr3+, Cu2+and Zn2+ions also reveals the greater affinity of the CS-GO SPR sensor to them, thus supporting the rationale for obtaining K for these two heavy metals. This study provides a better understanding on the sensing performance of such sensors in detecting heavy metal ions.
    Matched MeSH terms: Signal-To-Noise Ratio
  3. Kamel NS, Sim KS
    Scanning, 2004 12 23;26(6):277-81.
    PMID: 15612204
    During the last three decades, several techniques have been proposed for signal-to-noise ratio (SNR) and noise variance estimation in images, with different degrees of success. Recently, a novel technique based on the statistical autoregressive model (AR) was developed and proposed as a solution to SNR estimation in scanning electron microscope (SEM) image. In this paper, the efficiency of the developed technique with different imaging systems is proven and presented as an optimum solution to image noise variance and SNR estimation problems. Simulation results are carried out with images like Lena, remote sensing, and SEM. The two image parameters, SNR and noise variance, are estimated using different techniques and are compared with the AR-based estimator.
    Matched MeSH terms: Signal-To-Noise Ratio
  4. Katiri R, Hall DA, Buggy N, Hogan N, Horobin A, van de Heyning P, et al.
    Trials, 2020 Mar 04;21(1):238.
    PMID: 32131880 DOI: 10.1186/s13063-020-4094-9
    BACKGROUND: Single-sided deafness (SSD) describes the presence of a unilateral severe to profound sensorineural hearing loss. SSD disrupts spatial hearing and understanding speech in background noise. It has functional, psychological and social consequences. Potential options for rehabilitation include hearing aids and auditory implants. Benefits and harms of these interventions are documented inconsistently in the literature, using a variety of outcomes ranging from tests of speech perception to quality of life questionnaires. It is therefore difficult to compare interventions when rehabilitating SSD. The Core Rehabilitation Outcome Set for Single Sided Deafness (CROSSSD) study is an international initiative that aims to develop a minimum set of core outcomes for use in future trials of SSD interventions.

    METHODS/DESIGN: The CROSSSD study adopts an international two-round online modified Delphi survey followed by a stakeholder consensus meeting to identify a patient-centred core outcome domain set for SSD based on what is considered critical and important for assessing whether an intervention for SSD has worked.

    DISCUSSION: The resulting core outcome domain set will act as a minimum standard for reporting in future clinical trials and could have further applications in guiding the use of outcome measures in clinical practice. Standardisation will facilitate comparison of research findings.

    Matched MeSH terms: Noise
  5. Khairul Anuar Mohd Salleh, Ab. Razak Hamzah, Wan Muhammad Saridan Wan Hassan
    MyJurnal
    Developments of computer technology and image processing have shifted conventional industrial radiography application to industrial digital radiography (IDR) system. In this study, two types of IDR modules for non destructive testing (NDT), namely drum- and laser- type film digitizer with 50 μm pixel pitch have been evaluated for NDT applications. The modulation transfer function (MTF) and noise power spectrum (NPS) measurement were adapted to evaluate the image quality of IDR images. Results shown the averaged MTF for drum- and laser- type film digitizer at 20% modulation were 6.15 cycles/mm and 6.55 cycles/mm respectively. For NPS measurement and calculation, the result obtained shows that drum type film digitizer produced higher noise then laser type film digitizer. The study shows that the laser type film digitizer is the best system to be used for film digitization purposes because the MTF result shows that it modulates better than drum type and has the lowest and stable NPS.
    Matched MeSH terms: Noise
  6. Khairur Rijal Jamaludin, Nolia Harudin, Faizir Ramlie, Mohd Nabil Muhtazaruddin, Che Munira Che Razali, Wan Zuki Azman Wan Muhamad
    MATEMATIKA, 2020;36(1):69-84.
    MyJurnal
    Prediction analysis has drawn significant interest in numerous field. Taguchi’s T-Method is a prediction tool that developed practically but not limited to small sample analysis. It was developed explicitly for multidimensional system prediction by relying on historical data as the baseline model and adapting the signal to noise ratio (SNR) as well as zero proportional concepts in strengthening its robustness. Orthogonal array (OA) in T-Method is a variable selection optimization technique in improving the prediction accuracy as well as help in eliminating variables that may deteriorate the overall performance. However, the limitation of OA in dealing with higher multidimensionality restraint the optimization accuracy. Binary particle swarm optimization used in this study helps to cater to the limitation of OA as well as optimizing the variable selection process to better prediction accuracy. The results show that if the historical data consist of samples with higher correlation of determination (R2) value for the model creation, the optimization process in reducing the number of variables would be much reliable and accurate. Comparing between T-Method+OA and T-Method+BPSO in four different case study, it shows that T-Method+BPSO performing better with greater R2 and means relative error (MRE) value compared to T-Method+OA.
    Matched MeSH terms: Signal-To-Noise Ratio
  7. Khor HL, Liew SC, Zain JM
    J Digit Imaging, 2017 Jun;30(3):328-349.
    PMID: 28050716 DOI: 10.1007/s10278-016-9930-9
    Tampering on medical image will lead to wrong diagnosis and treatment, which is life-threatening; therefore, digital watermarking on medical image was introduced to protect medical image from tampering. Medical images are divided into region of interest (ROI) and region of non-interest (RONI). ROI is an area that has a significant impact on diagnosis, whereas RONI has less or no significance in diagnosis. This paper has proposed ROI-based tamper detection and recovery watermarking scheme (ROI-DR) that embeds ROI bit information into RONI least significant bits, which will be extracted later for authentication and recovery process. The experiment result has shown that the ROI-DR has achieved a good result in imperceptibility with peak signal-to-noise ratio (PSNR) values approximately 48 dB, it is robust against various kinds of tampering, and the tampered ROI was able to recover to its original form. Lastly, a comparative table with the previous research (TALLOR and TALLOR-RS watermarking schemes) has been derived, where these three watermarking schemes were tested under the same testing conditions and environment. The experiment result has shown that ROI-DR has achieved speed-up factors of 22.55 and 26.65 in relative to TALLOR and TALLOR-RS watermarking schemes, respectively.
    Matched MeSH terms: Signal-To-Noise Ratio
  8. Kulathilake KASH, Abdullah NA, Bandara AMRR, Lai KW
    J Healthc Eng, 2021;2021:9975762.
    PMID: 34552709 DOI: 10.1155/2021/9975762
    Low-dose Computed Tomography (LDCT) has gained a great deal of attention in clinical procedures due to its ability to reduce the patient's risk of exposure to the X-ray radiation. However, reducing the X-ray dose increases the quantum noise and artifacts in the acquired LDCT images. As a result, it produces visually low-quality LDCT images that adversely affect the disease diagnosing and treatment planning in clinical procedures. Deep Learning (DL) has recently become the cutting-edge technology of LDCT denoising due to its high performance and data-driven execution compared to conventional denoising approaches. Although the DL-based models perform fairly well in LDCT noise reduction, some noise components are still retained in denoised LDCT images. One reason for this noise retention is the direct transmission of feature maps through the skip connections of contraction and extraction path-based DL modes. Therefore, in this study, we propose a Generative Adversarial Network with Inception network modules (InNetGAN) as a solution for filtering the noise transmission through skip connections and preserving the texture and fine structure of LDCT images. The proposed Generator is modeled based on the U-net architecture. The skip connections in the U-net architecture are modified with three different inception network modules to filter out the noise in the feature maps passing over them. The quantitative and qualitative experimental results have shown the performance of the InNetGAN model in reducing noise and preserving the subtle structures and texture details in LDCT images compared to the other state-of-the-art denoising algorithms.
    Matched MeSH terms: Signal-To-Noise Ratio
  9. Lee, K.Y., Ho, L.Y., Tan, K.H., Tham, Y.Y., Ling, S.P., Qureshi, A.M., et al.
    MyJurnal
    In the perspective of recent bauxite mining in Malaysia, this review aims to identify the potential
    environmental and health impacts on miners and surrounding communities. The environmental issues of
    bauxite mining include, air, water and soil pollution due to bauxite dust; leaching of bauxite into water
    sources resulting in reduced soil fertility as well as affecting agricultural food products and aquatic life.
    Bauxite occupational exposure affects the health of miners, and has negative consequences on the health of
    surrounding communities, such as increased respiratory symptoms, contamination of drinking water, other
    potential health risks from ingestion of bauxite and heavy metals, including noise-induced hearing loss and
    mental stress. This review discusses the processes of bauxite mining, its constituents and residual trace
    elements, and their impact on the environment and health of exposed workers and communities. It also
    explores the Malaysian legal requirements and standards of occupational exposure to bauxite.
    Matched MeSH terms: Hearing Loss, Noise-Induced
  10. Lee, L., Sidek, R.M., Jamuar, S.S., Khatun, S.
    ASM Science Journal, 2009;3(1):59-69.
    MyJurnal
    A 2.4 GHz variable-gain low noise amplifier (VGLNA) intended for use in a Wide-band Code Division
    Multiple Access receiver was designed in 0.18 um CMOS process for low voltage and low power applications. Rivaling classical designs using voltage mode approach, this design used the current mode approach, utilizing the current mirror principle to obtain a controllable gain range from 8.26 dB to 16.95 dB with good input and output return losses. By varying the current through the widths of transistors and a bias resistor, the VGLNA was capable of exhibiting 8 dB gain tuning range without degrading the noise figure. Therefore, higher gain was possible at lower current and thus at lower power consumption. Total power consumption simulated was 4.63 mW from a 1 V supply and this gave a gain/power quotient of 3.66 dB/mW. Comparing this with available published data, it was observed that this work demonstrated a good gain tuning range and the lowest noise figure with such power consumption.
    Matched MeSH terms: Noise
  11. Li M, Mathai A, Lau SLH, Yam JW, Xu X, Wang X
    Sensors (Basel), 2021 Jan 05;21(1).
    PMID: 33466530 DOI: 10.3390/s21010313
    Due to medium scattering, absorption, and complex light interactions, capturing objects from the underwater environment has always been a difficult task. Single-pixel imaging (SPI) is an efficient imaging approach that can obtain spatial object information under low-light conditions. In this paper, we propose a single-pixel object inspection system for the underwater environment based on compressive sensing super-resolution convolutional neural network (CS-SRCNN). With the CS-SRCNN algorithm, image reconstruction can be achieved with 30% of the total pixels in the image. We also investigate the impact of compression ratios on underwater object SPI reconstruction performance. In addition, we analyzed the effect of peak signal to noise ratio (PSNR) and structural similarity index (SSIM) to determine the image quality of the reconstructed image. Our work is compared to the SPI system and SRCNN method to demonstrate its efficiency in capturing object results from an underwater environment. The PSNR and SSIM of the proposed method have increased to 35.44% and 73.07%, respectively. This work provides new insight into SPI applications and creates a better alternative for underwater optical object imaging to achieve good quality.
    Matched MeSH terms: Signal-To-Noise Ratio
  12. Liew SC, Liew SW, Zain JM
    J Digit Imaging, 2013 Apr;26(2):316-25.
    PMID: 22555905 DOI: 10.1007/s10278-012-9484-4
    Tamper localization and recovery watermarking scheme can be used to detect manipulation and recover tampered images. In this paper, a tamper localization and lossless recovery scheme that used region of interest (ROI) segmentation and multilevel authentication was proposed. The watermarked images had a high average peak signal-to-noise ratio of 48.7 dB and the results showed that tampering was successfully localized and tampered area was exactly recovered. The usage of ROI segmentation and multilevel authentication had significantly reduced the time taken by approximately 50 % for the tamper localization and recovery processing.
    Matched MeSH terms: Signal-To-Noise Ratio
  13. Lim CS, Krishnan G, Sam CK, Ng CC
    Clin Chim Acta, 2013 Jan 16;415:158-61.
    PMID: 23043757 DOI: 10.1016/j.cca.2012.08.031
    Because blocking agent occupies most binding surface of a solid phase, its ability to prevent nonspecific binding determines the signal-to-noise ratio (SNR) and reliability of an enzyme-linked immunosorbent assay (ELISA).
    Matched MeSH terms: Signal-To-Noise Ratio
  14. Lim EY, Tang IP, Peyman M, Ramli N, Narayanan P, Rajagopalan R
    Eur Arch Otorhinolaryngol, 2015 Nov;272(11):3109-13.
    PMID: 25205300 DOI: 10.1007/s00405-014-3232-y
    High acoustic noise level is one of the unavoidable side effects of 3 T magnetic resonance imaging (MRI). A case of hearing loss after 3 T MRI has been reported in this institution and hence this study. The objective of this study was to determine whether temporary threshold shift (TTS) in high frequency hearing occurs in patients undergoing 3 T MRI scans of the head and neck. A total of 35 patients undergoing head and neck 3 T MRI for various clinical indications were tested with pure tone audiometry in different frequencies including high frequencies, before and after the MRI scan. Any threshold change from the recorded baseline of 10 dB was considered significant. All patients were fitted with foamed 3 M earplugs before the procedure following the safety guidelines for 3 T MRI. The mean time for MRI procedure was 1,672 s (range 1,040-2,810). The noise dose received by each patient amounted to an average of 3,906.29% (1,415-9,170%). The noise dose was derived from a normograph used by Occupational Noise Surveys. This was calculated using the nomograph of L eq, L EX, noise dose and time. There was no statistically significant difference between the hearing threshold before and after the MRI procedures for all the frequencies (paired t test, P > 0.05). For patients using 3 M foamed earplugs, noise level generated by 3 T MRI during routine clinical sequence did not cause any TTS in high frequency hearing.
    Matched MeSH terms: Hearing Loss, Noise-Induced/etiology*; Noise*
  15. Loh SH, Nur Iryani Mohd Yusof, How ML
    A method for the determination of aflatoxins B1 and B2 in peanuts and corn based products is described. The samples were extracted with a mixture of acetonitrile-water (84:16), followed by multifunctional clean-up and liquid chromatography with fluorescence detection. Both calibration curves showed good correlation from 4.0 to 32.0 ppb for aflatoxin B1 (r=0.9999) and 1.2 to 9.6 ppb for aflatoxin B2 (r=0.9997). The detection limit of aflatoxins B1 and B2 were established at 0.1 and 0.03 ppb, respectively, based on signal-to-noise ratio of 3:1. Average recoveries for the determination of aflatoxins B1 and B2 at 10 and 3 ppb spiking levels, respectively ranged from 94.2 to 107.6%. A total of 20 peanut samples and corn based products were obtained from retail shop and local market around Kuala Terengganu and analyzed for aflatoxins B1 and B2 contents, using the proposed method. Aflatoxins B1 and B2 were detected in 5 out of the 9 peanuts samples and 5 out of the 11 corn based products, at levels ranging from 0.2 to 101.8 ppb.
    Matched MeSH terms: Signal-To-Noise Ratio
  16. Lombigit, Lojius, Maslina Ibrahim, Nolida Yusup, Nur Aira Abdul Rahman, Yong, Chong Fong
    MyJurnal
    Pulse Shaping Amplifier (PSA) is an essential component in nuclear spectroscopy system. This
    amplifier has two functions; to shape the output pulse and performs noise filtering. In this paper,
    we describe the procedure for the design and development of a pulse shaping amplifier which can
    be used in a nuclear spectroscopy system. This prototype was developed using high performance
    electronics devices and assembled on a FR4 type printed circuit board. Performance of this
    prototype was tested by comparing it with an equivalent commercial spectroscopy amplifier (Model
    Silena 7611). The test results showed that the performance of this prototype was comparable
    to the commercial spectroscopic amplifier.
    Matched MeSH terms: Noise
  17. Lu TS, Flaherty GT
    J Travel Med, 2018 01 01;25(1).
    PMID: 30346571 DOI: 10.1093/jtm/tay106
    Matched MeSH terms: Hearing Loss, Noise-Induced/prevention & control*
  18. Lubis LE, Bayuadi I, Pawiro SA, Ng KH, Bosmans H, Soejoko DS
    Phys Med, 2015 Nov;31(7):659-68.
    PMID: 26050060 DOI: 10.1016/j.ejmp.2015.05.011
    The purpose of this study is to quantify the quality of the available imaging modes for various iodine-based contrast agent concentration in paediatric cardiology. The figure of merit (FOM) was defined as the squared signal to noise ratio divided by a patient dose related parameter. An in house constructed phantom simulated a series of vessel segments with iodine concentrations from 10% or 30 mg/cc to 16% or 48 mg/cc of iodine in a blood plasma solution, all within the dimensional constraints of a paediatric patient. The phantom also used test inserts of tin (Sn). Measurements of Entrance Surface Air Kerma (ESAK) and exit dose rate were performed along with calculations of the signal-to-noise ratio (SNR) of all the objects. A first result showed that it was favourable to employ low dose fluoroscopy mode and lower frame rate modes in cine acquisition if dynamic information is not critical. Normal fluoroscopy dose mode provided a considerably higher dose level (in comparison to low dose mode) with only a slight improvement in SNR. Higher frame rate cine modes should be used however when the clinical situation dictates so. This work also found that tin should not be intended as iodine replacement material for research purposes due to the mismatching SNR, particularly on small vessel sizes.
    Matched MeSH terms: Signal-To-Noise Ratio
  19. Maamor N, Billings CJ
    Neurosci Lett, 2017 01 01;636:258-264.
    PMID: 27838448 DOI: 10.1016/j.neulet.2016.11.020
    The purpose of this study was to determine the effects of noise type, signal-to-noise ratio (SNR), age, and hearing status on cortical auditory evoked potentials (CAEPs) to speech sounds. This helps to explain the hearing-in-noise difficulties often seen in the aging and hearing impaired population. Continuous, modulated, and babble noise types were presented at varying SNRs to 30 individuals divided into three groups according to age and hearing status. Significant main effects of noise type, SNR, and group were found. Interaction effects revealed that the SNR effect varies as a function of noise type and is most systematic for continuous noise. Effects of age and hearing loss were limited to CAEP latency and were differentially modulated by energetic and informational-like masking. It is clear that the spectrotemporal characteristics of signals and noises play an important role in determining the morphology of neural responses. Participant factors such as age and hearing status, also play an important role in determining the brain's response to complex auditory stimuli and contribute to the ability to listen in noise.
    Matched MeSH terms: Signal-To-Noise Ratio*
  20. Maisarah SZ, Said H
    Med J Malaysia, 1993 Sep;48(3):280-5.
    PMID: 8183139
    A total of 524 industrial workers were studied. They consisted of 442 noise exposed and 82 non-noise exposed workers. The purpose was to compare the prevalence of sensori-neural hearing loss among the noise exposed and the non-noise exposed workers, to study their knowledge on the hazard of noise to hearing and the workers' attitude towards the hearing protection devices. The prevalence of sensori-neural hearing loss was significantly higher among the noise exposed workers, i.e., 83% versus 31.7% (p < 0.01). However, the prevalence of hearing impairment was much lower for both groups, being 30.1% for the noise exposed and 3.7% for the non-noise exposed group. Although hearing protection devices were provided to 80.5% of the workers, only 5.1% were wearing them regularly. The possibility of developing hearing loss due to exposure to excessive noise was only known by 35.5% of the noise exposed workers. This awareness was found to have a positive correlation with the workers' compliance to the hearing protection devices. Our findings highlight the need for workers to be educated on the hazards of excessive noise exposure to hearing.
    Matched MeSH terms: Hearing Loss, Noise-Induced/epidemiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links