Displaying publications 121 - 140 of 535 in total

Abstract:
Sort:
  1. Salehmin MNI, Hil Me MF, Daud WRW, Mohd Yasin NH, Abu Bakar MH, Sulong AB, et al.
    Sci Total Environ, 2023 Jan 10;855:158527.
    PMID: 36096221 DOI: 10.1016/j.scitotenv.2022.158527
    Microbial electrodialysis cells (MEDCs) offer simultaneous wastewater treatment, water desalination, and hydrogen production. In a conventional design of MEDCs, the overall performance is retarded by the accumulation of protons on the anode due to the integration of an anion exchange membrane (AEM). The accumulation of protons reduces the anolyte pH to become acidic, affecting the microbial viability and thus limiting the charge carrier needed for the cathodic reaction. This study has modified the conventional MEDC with an internal proton migration pathway, known as the internal proton migration pathway-MEDC (IP-MEDC). Simulation tests under abiotic conditions demonstrated that the pH changes in the anolyte and catholyte of IP-MEDC were smaller than the pH changes in the anolyte and catholyte without the proton pathways. Under biotic conditions, the performance of the IP-MEDC agreed well with the simulation test, showing a significantly higher chemical oxygen demand (COD) removal rate, desalination rate, and hydrogen production than without the migration pathway. This result is supported by the lowest charge transfer resistance shown by EIS analysis and the abundance of microbes on the bioanode through field emission scanning electron microscopy (FESEM) observation. However, hydrogen production was diminished in the second-fed batch cycle, presumably due to the active diffusion of high Cl¯ concentrations from desalination to the anode chamber, which was detrimental to microbial growth. Enlarging the anode volume by threefold improved the COD removal rate and hydrogen production rate by 1.7- and 3.4-fold, respectively, owing to the dilution effect of Cl¯ in the anode. This implied that the dilution effect satisfies both the microbial viability and conductivity. This study also suggests that the anolyte and catholyte replacement frequencies can be reduced, typically at a prolonged hydraulic retention time, thus minimizing the operating cost (e.g., solution pumping). The use of a high concentration of NaCl (35 g L-1) in the desalination chamber and catholyte provides a condition that is close to practicality.
    Matched MeSH terms: Waste Water
  2. Sakai N, Sakai M, Mohamad Haron DE, Yoneda M, Ali Mohd M
    Chemosphere, 2016 Dec;165:183-190.
    PMID: 27654221 DOI: 10.1016/j.chemosphere.2016.09.022
    Fourteen beta-agonists were quantitatively analyzed in cattle, chicken and swine liver specimens purchased at 14 wet markets in Selangor State, Malaysia, by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The health risks of ractopamine and clenbuterol residues in the Malaysian population were assessed based on quantitative data and meat consumption statistics in Malaysia. Wastewater samples collected at swine farms (n = 2) and cattle/cow farms (n = 2) in the Kuala Langat district were analyzed for the presence for the 14 compounds. Wastewater in chicken farms was not collected because there was negligible discharge during the breeding period. The environmental impacts caused by beta-agonists discharged from livestock farms were spatially assessed in the Langat River basin using a geographic information system (GIS). As a result, 10 compounds were detected in the liver specimens. Ractopamine, which is a permitted compound for swine in Malaysia, was frequently detected in swine livers; also, 9 other compounds that are prohibited compounds could be illegally abused among livestock farms. The health risks of ractopamine and clenbuterol were assessed to be minimal as their hazard quotients were no more than 7.82 × 10(-4) and 2.71 × 10(-3), respectively. Five beta-agonists were detected in the wastewater samples, and ractopamine in the swine farm resulted in the highest contamination (30.1 μg/L). The environmental impacts of the beta-agonists in the Langat River basin were generally concluded to be minimal, but the ractopamine contamination released from swine farms was localized in coastal areas near the estuary of the Langat River basin because most swine farms were located in that region.
    Matched MeSH terms: Waste Water/analysis*
  3. Sahari NS, Shahir S, Ibrahim Z, Hasmoni SH, Altowayti WAH
    Environ Sci Pollut Res Int, 2023 Nov;30(51):110069-110078.
    PMID: 37814051 DOI: 10.1007/s11356-023-30067-w
    This review discusses the application of bacterial nanocellulose (BNC) and modified BNC in treating wastewater containing heavy metals and dye contaminants. It also highlights the challenges and future perspectives of BNC and its composites. Untreated industrial effluents containing toxic heavy metals are systematically discharged into public waters. In particular, lead (Pb), copper (Cu), cadmium (Cd), nickel (Ni), zinc (Zn), and arsenic (As) are very harmful to human health and, in some cases, may lead to death. Several methods such as chemical precipitation, ion exchange, membrane filtration, coagulation, and Fenton oxidation are used to remove these heavy metals from the environment. However, these methods involve the use of numerous chemicals whilst producing high amount of toxic sludge. Meanwhile, the development of the adsorption-based technique has provided an alternative way of treating wastewater using BNC. Bacterial nanocellulose requires less energy for purification and has higher purity than plant cellulose. In general, the optimum growth parameters are crucial in BNC production. Even though native BNC can be used for the removal of heavy metals and dyes, the incorporation of other materials, such as polyethyleneimine, graphene oxide, calcium carbonate and polydopamine can improve sorption efficiencies.
    Matched MeSH terms: Waste Water*
  4. Sadiq AC, Olasupo A, Ngah WSW, Rahim NY, Suah FBM
    Int J Biol Macromol, 2021 Nov 30;191:1151-1163.
    PMID: 34600954 DOI: 10.1016/j.ijbiomac.2021.09.179
    The presence of dyes in the aquatic environment as a result of anthropogenic activities, especially textile industries, is a critical environmental challenge that hinders the availability of potable water. Different wastewater treatment approaches have been used to remediate dyes in aquatic environments; however, most of these approaches are limited by factors ranging from high cost to the incomplete removal of the dyes and contaminants. Thus, the use of adsorption as a water treatment technology to remove dyes and other contaminants has been widely investigated using different adsorbents. This study evaluated the significance of chitosan as a viable adsorbent for removing dyes from water treatment. We summarised the literature and research results obtained between 2009 and 2020 regarding the adsorption of dyes onto chitosan and modified chitosan-based adsorbents prepared through physical and chemical processing, including crosslinking impregnation, grafting, and membrane preparation. Furthermore, we demonstrated the effects of various chitosan-based materials and modifications; they all improve the properties of chitosan by promoting the adsorption of dyes. Hence, the application of chitosan-based materials with various modifications should be considered a cutting-edge approach for the remediation of dyes and other contaminants in aquatic environments toward the global aim of making potable water globally available.
    Matched MeSH terms: Waste Water
  5. Sadiq AC, Olasupo A, Rahim NY, Ngah WSW, Hanafiah MAKM, Suah FBM
    Int J Biol Macromol, 2023 Jul 31;244:125400.
    PMID: 37330084 DOI: 10.1016/j.ijbiomac.2023.125400
    Several water and wastewater technologies have been implored for the removal of dyes during wastewater treatments; however; different types have been reportedly found in surface and groundwater systems. Hence, there is a need to investigate other water treatment technologies for the complete remediation of dyes in aquatic environments. In this study, novel chitosan-based polymer inclusion membranes (PIMs) were synthesized for the removal of malachite green dye (MG) which is a recalcitrant of great concern in water. Two types of PIMs were synthesized in this study, the first PIM (PIMs-A) was composed of chitosan, bis-(2-ethylhexyl) phosphate (B2EHP), and dioctyl phthalate (DOP). While, the second PIMs (PIMs-B) were composed of chitosan, Aliquat 336, and DOP. The physico-thermal stability of the PIMs was investigated using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and thermogravimetric analysis (TGA), both PIMs demonstrated good stability with a weak intermolecular force of attraction amongst the various components of the membranes. The effects of the initial concentration of MG, pH of the MG solution, stripping solution, and time were investigated. At optimum conditions, both membranes (PIM-A and B) recorded the highest efficiencies of 96 % and 98 % at pH 4 and initial contaminants concentration of 50 mg/L, respectively. Finally, both PIMs were used for the removal of MG in different environmental samples (river water, seawater, and tap water) with an average removal efficiency of 90 %. Thus, the investigated PIMs can be considered a potential suitable technique for the removal of dyes and other contaminants from aquatic matrices.
    Matched MeSH terms: Waste Water
  6. Rusmin R, Sarkar B, Tsuzuki T, Kawashima N, Naidu R
    Chemosphere, 2017 Nov;186:1006-1015.
    PMID: 28838038 DOI: 10.1016/j.chemosphere.2017.08.036
    A palygorskite-iron oxide nanocomposite (Pal-IO) was synthesized in situ by embedding magnetite into the palygorskite structure through co-precipitation method. The physico-chemical characteristics of Pal-IO and their pristine components were examined through various spectroscopic and micro-analytical techniques. Batch adsorption experiments were conducted to evaluate the performance of Pal-IO in removing Pb(II) from aqueous solution. The surface morphology, magnetic recyclability and adsorption efficiency of regenerated Pal-IO using desorbing agents HCl (Pal-IO-HCl) and ethylenediaminetetraacetic acid disodium salt (EDTA-Na2) (Pal-IO-EDTA) were compared. The nanocomposite showed a superparamagnetic property (magnetic susceptibility: 20.2 emu g-1) with higher specific surface area (99.8 m2 g-1) than the pristine palygorskite (49.4 m2 g-1) and iron oxide (72.6 m2 g-1). Pal-IO showed a maximum Pb(II) adsorption capacity of 26.6 mg g-1 (experimental condition: 5 g L-1 adsorbent loading, 150 agitations min-1, initial Pb(II) concentration from 20 to 500 mg L-1, at 25 °C) with easy separation of the spent adsorbent. The adsorption data best fitted to the Langmuir isotherm model (R2 = 0.9995) and pseudo-second order kinetic model (R2 = 0.9945). Pb(II) desorption using EDTA as the complexing agent produced no disaggregation of Pal-IO crystal bundles, and was able to preserve the composite's magnetic recyclability. Pal-IO-EDTA exhibited almost 64% removal capacity after three cycles of regeneration and preserved the nanocomposite's structural integrity and magnetic properties (15.6 emu g-1). The nanocomposite holds advantages as a sustainable material (easily separable and recyclable) for potential application in purifying heavy metal contaminated wastewaters.
    Matched MeSH terms: Waste Water/chemistry
  7. Rozaini MNH, Khoo KS, Abdah MAAM, Ethiraj B, Alam MM, Anwar AF, et al.
    Environ Geochem Health, 2024 Mar 11;46(3):111.
    PMID: 38466501 DOI: 10.1007/s10653-024-01917-4
    With the advancement of technologies and growth of the economy, it is inevitable that more complex processes are deployed, producing more heterogeneous wastewater that comes from biomedical, biochemical and various biotechnological industries. While the conventional way of wastewater treatment could effectively reduce the chemical oxygen demand, pH and turbidity of wastewater, trace pollutants, specifically the endocrine disruptor compounds (EDCs) that exist in µg L-1 or ng L-1 have further hardened the detection and removal of these biochemical pollutants. Even in small amounts, EDC could interfere human's hormone, causing severe implications on human body. Hence, this review elucidates the recent insights regarding the effectiveness of an advanced 2D material based on titanium carbide (Ti3C2Tx), also known as MXene, in detecting and removing EDCs. MXene's highly tunable feature also allows its surface chemistry to be adjusted by adding chemicals with different functional groups to adsorb different kinds of EDCs for biochemical pollution mitigation. At the same time, the incorporation of MXene into sample matrices also further eases the analysis of trace pollutants down to ng L-1 levels, thereby making way for a more cleaner and comprehensive wastewater treatment. In that sense, this review also highlights the progress in synthesizing MXene from the conventional method to the more modern approaches, together with their respective key parameters. To further understand and attest to the efficacy of MXene, the limitations and current gaps of this potential agent are also accentuated, targeting to seek resolutions for a more sustainable application.
    Matched MeSH terms: Waste Water
  8. Rosman NH, Nor Anuar A, Othman I, Harun H, Sulong Abdul Razak MZ, Elias SH, et al.
    Bioresour Technol, 2013 Feb;129:620-3.
    PMID: 23317554 DOI: 10.1016/j.biortech.2012.12.113
    Aerobic granular sludge (AGS) was successfully cultivated at 27±1 °C and pH 7.0±1 during the treatment of rubber wastewater using a sequential batch reactor system mode with complete cycle time of 3 h. Results showed aerobic granular sludge had an excellent settling ability and exhibited exceptional performance in the organics and nutrients removal from rubber wastewater. Regular, dense and fast settling granule (average diameter, 1.5 mm; settling velocity, 33 m h(-1); and sludge volume index, 22.3 mL g(-1)) were developed in a single reactor. In addition, 96.5% COD removal efficiency was observed in the system at the end of the granulation period, while its ammonia and total nitrogen removal efficiencies were up to 94.7% and 89.4%, respectively. The study demonstrated the capabilities of AGS development in a single, high and slender column type-bioreactor for the treatment of rubber wastewater.
    Matched MeSH terms: Waste Water/microbiology*
  9. Rosman N, Salleh WNW, Mohamed MA, Jaafar J, Ismail AF, Harun Z
    J Colloid Interface Sci, 2018 Dec 15;532:236-260.
    PMID: 30092507 DOI: 10.1016/j.jcis.2018.07.118
    Reports of pharmaceuticals exist in surface water and drinking water around the world, indicate they are ineffectively remove from water and wastewater using conventional treatment technologies. The potential of adverse effect of these pharmaceuticals on public health and aquatic life, also their continuos accumulation have raised the development of water treatment technologies. Hybrid treatment processes like membrane filtration and advance oxidation processes (AOPs) are likely to give rise to efficient simultaneous degradation and separation mechanisms. Conventional membrane filtration techniques can remove the majority of contaminants, but the smallest, undegraded, and stabilized pharmaceutical wastes persist in the treated water. After some 20 years, researchers have recognized the important role of AOPs in the treatment of pharmaceutical wastewater because these technologies are capable of oxidizing recalcitrant, toxic, and non-biodigradable compounds into numerous by-products and finally, inert end-products via the intermediacy of hydroxyl and other radicals. Evidently, membranes are subjected to the fouling phenomenon by the contaminants in wastewater, hence resulting in a reduction of clean water flux and increase in energy demand. In such situations, these membrane hybrid AOPs exert a complementary effect in the elimination of membrane fouling, thus enhancing the performance of the membrane. Therefore, in this review, we describe the basic aspects of the removal and transformation of certain pharmaceuticals via membranes and AOPs. In addition, information and evidences on membrane hybrid AOPs in the field of pharmaceutical wastewater treatment is also presented.
    Matched MeSH terms: Waste Water/chemistry*
  10. Rezania S, Ponraj M, Talaiekhozani A, Mohamad SE, Md Din MF, Taib SM, et al.
    J Environ Manage, 2015 Nov 1;163:125-33.
    PMID: 26311085 DOI: 10.1016/j.jenvman.2015.08.018
    The development of eco-friendly and efficient technologies for treating wastewater is one of the attractive research area. Phytoremediation is considered to be a possible method for the removal of pollutants present in wastewater and recognized as a better green remediation technology. Nowadays the focus is to look for a sustainable approach in developing wastewater treatment capability. Water hyacinth is one of the ancient technology that has been still used in the modern era. Although, many papers in relation to wastewater treatment using water hyacinth have been published, recently removal of organic, inorganic and heavy metal have not been reviewed extensively. The main objective of this paper is to review the possibility of using water hyacinth for the removal of pollutants present in different types of wastewater. Water hyacinth is although reported to be as one of the most problematic plants worldwide due to its uncontrollable growth in water bodies but its quest for nutrient absorption has provided way for its usage in phytoremediation, along with the combination of herbicidal control, integratated biological control and watershed management controlling nutrient supply to control its growth. Moreover as a part of solving wastewater treatment problems in urban or industrial areas using this plant, a large number of useful byproducts can be developed like animal and fish feed, power plant energy (briquette), ethanol, biogas, composting and fiber board making. In focus to the future aspects of phytoremediation, the utilization of invasive plants in pollution abatement phytotechnologies can certainly assist for their sustainable management in treating waste water.
    Matched MeSH terms: Waste Water/chemistry*
  11. Rezania S, Taib SM, Md Din MF, Dahalan FA, Kamyab H
    J Hazard Mater, 2016 Nov 15;318:587-599.
    PMID: 27474848 DOI: 10.1016/j.jhazmat.2016.07.053
    Environmental pollution specifically water pollution is alarming both in the developed and developing countries. Heavy metal contamination of water resources is a critical issue which adversely affects humans, plants and animals. Phytoremediation is a cost-effective remediation technology which able to treat heavy metal polluted sites. This environmental friendly method has been successfully implemented in constructed wetland (CWs) which is able to restore the aquatic biosystem naturally. Nowadays, many aquatic plant species are being investigated to determine their potential and effectiveness for phytoremediation application, especially high growth rate plants i.e. macrophytes. Based on the findings, phytofiltration (rhizofiltration) is the sole method which defined as heavy metals removal from water by aquatic plants. Due to specific morphology and higher growth rate, free-floating plants were more efficient to uptake heavy metals in comparison with submerged and emergent plants. In this review, the potential of wide range of aquatic plant species with main focus on four well known species (hyper-accumulators): Pistia stratiotes, Eicchornia spp., Lemna spp. and Salvinia spp. was investigated. Moreover, we discussed about the history, methods and future prospects in phytoremediation of heavy metals by aquatic plants comprehensively.
    Matched MeSH terms: Waste Water
  12. Rezania S, Park J, Md Din MF, Mat Taib S, Talaiekhozani A, Kumar Yadav K, et al.
    Mar Pollut Bull, 2018 Aug;133:191-208.
    PMID: 30041307 DOI: 10.1016/j.marpolbul.2018.05.022
    Microplastics (MPs) are generated from plastic and have negative impact to our environment due to high level of fragmentation. They can be originated from various sources in different forms such as fragment, fiber, foam and so on. For detection of MPs, many techniques have been developed with different functions such as microscopic observation, density separation, Raman and FTIR analysis. Besides, due to ingestion of MPs by wide range of marine species, research on the effect of this pollution on biota as well as human is vital. Therefore, we comprehensively reviewed the occurrence and distribution of MPs pollution in both marine and freshwater environments, including rivers, lakes and wastewater treatment plants (WWTPs). For future studies, we propose the development of new techniques for sampling MPs in aquatic environments and biota and recommend more research regarding MPs release by WWTPs.
    Matched MeSH terms: Waste Water
  13. Revathi M, Sivagaami Sundari G, Ahmed Basha C, Alam M, Sagadevan S, Ahmad N
    J Nanosci Nanotechnol, 2020 10 01;20(10):6547-6554.
    PMID: 32385012 DOI: 10.1166/jnn.2020.18562
    This investigation aims at the reclamation of Cr(VI) from synthetic electroplating industrial effluent by electroextraction process namely electrochemical ion exchange (EIX). An electrochemical ion exchange reactor of desired dimensions was fabricated with the help of ion-permeable membranes, stainless steel cathode and PbO₂ coated Ti expanded mesh anode. The performance of the reactor was studied in batch recirculation mode, continuous flow mode at different experimental conditions. The influence of various experimental factors, for instance, initial metal ion concentration (20, 300, 1000 mg/L of Cr(VI)), applied voltages (2.5 V, 5 V, 7.5 V, 10 V) and flow rates of the process stream (2, 4, 6, 8, 10, 12 and 14 ml/min) on removal/reclamation efficiency was deliberated. For comparison purposes, an electrodialysis process was conducted at the same optimal conditions. It was found that the EIX process with three compartments has more removal efficiency at optimum experimental conditions than the electrodialysis process. The continuous flow process of the reactor with 300 mg/L of Cr(VI) as inlet concentration has studied to predict the breakeven point of the reactor. It was noted that Cr(VI) ion concentration in the treated wastewater is almost zero up to the discharge of 20 liters of treated rinse water.
    Matched MeSH terms: Waste Water
  14. Razak MR, Yusof NA, Haron MJ, Ibrahim N, Mohammad F, Kamaruzaman S, et al.
    Int J Biol Macromol, 2018 Jun;112:754-760.
    PMID: 29428390 DOI: 10.1016/j.ijbiomac.2018.02.035
    In the present study, iminodiacetic acid (IDA)-modified kenaf fiber, K-IDA formed by the chemical modification of plant kenaf biomass was tested for its efficacy as a sorbent material towards the purification of waste water. The K-IDA fiber was first characterized by the instrumental techniques like Fourier transform infrared (FTIR) analysis, elemental analysis (CHNSO), and scanning electron microscopy (SEM). On testing for the biosorption, we found that the K-IDA has an increment in the adsorption of Cu2+ ions as compared against the untreated fiber. The Cu2+ ions adsorption onto K-IDA fits very well with the Langmuir model and the adsorption maximum achieved to be 91.74mg/g. Further, the adsorption kinetics observed to be pseudo second-order kinetics model and the Cu2+ ions adsorption is a spontaneous endothermic process. The desorption study indicates a highest percentage of Cu2+ of 97.59% from K-IDA under 1M HCl solution against H2SO4 (72.59%) and HNO3 (68.66%). The reusability study indicates that the efficiency did not change much until the 4th cycle and also providing enough evidence for the engagement of our biodegradable K-IDA fiber towards the removal of Cu2+ ions in real-time waste water samples obtained from the electroplating and wood treatment industries.
    Matched MeSH terms: Waste Water*
  15. Rawindran H, Arif Bin Hut N, Vrasna DK, Goh PS, Lim JW, Liew CS, et al.
    Chemosphere, 2024 Jan;346:140591.
    PMID: 37918531 DOI: 10.1016/j.chemosphere.2023.140591
    Current study had made a significant progress in microalgal wastewater treatment through the implementation of an economically viable polyethylene terephthalate (PET) membrane derived from plastic bottle waste. The membrane exhibited an exceptional pure water flux of 156.5 ± 0.25 L/m2h and a wastewater flux of 15.37 ± 0.02 L/m2h. Moreover, the membrane demonstrated remarkable efficiency in selectively removing a wide range of residual parameters, achieving rejection rates up to 99%. The reutilization of treated wastewater to grow microalgae had resulted in a marginal decrease in microalgal density, from 10.01 ± 0.48 to 9.26 ± 0.66 g/g. However, this decline was overshadowed by a notable enhancement in lipid production with level rising from 181.35 ± 0.42 to 225.01 ± 0.11 mg/g. These findings signified the membrane's capacity to preserve nutrients availability within the wastewater; thus, positively influencing the lipid synthesis and accumulation within microalgal cells. Moreover, the membrane's comprehensive analysis of cross-sectional and surface topographies revealed the presence of macropores with a highly interconnected framework, significantly amplifying the available surface area for fluid flow. This exceptional structural attribute had substantially contributed to the membrane's efficacy by facilitating superior filtration and separation process. Additionally, the identified functional groups within the membrane aligned consistently with those commonly found in PET polymer, confirming the membrane's compatibility and efficacy in microalgal wastewater treatment.
    Matched MeSH terms: Waste Water*
  16. Ratnasari A, Syafiuddin A, Zaidi NS, Hong Kueh AB, Hadibarata T, Prastyo DD, et al.
    Environ Pollut, 2022 Jan 01;292(Pt B):118474.
    PMID: 34763013 DOI: 10.1016/j.envpol.2021.118474
    The emergence and continual accumulation of industrial micropollutants such as dyes, heavy metals, organic matters, and pharmaceutical active compounds (PhACs) in the ecosystem pose an alarming hazard to human health and the general wellbeing of global flora and fauna. To offer eco-friendly solutions, living and non-living algae have lately been identified and broadly practiced as promising agents in the bioremediation of micropollutants. The approach is promoted by recent findings seeing better removal performance, higher efficiency, surface area, and binding affinity of algae in various remediation events compared to bacteria and fungi. To give a proper and significant insight into this technology, this paper comprehensively reviews its current applications, removal mechanisms, comparative efficacies, as well as future outlooks and recommendations. In conducting the review, the secondary data of micropollutants removal have been gathered from numerous sources, from which their removal performances are analyzed and presented in terms of strengths, weaknesses, opportunities, and threats (SWOT), to specifically examine their suitability for selected micropollutants remediation. Based on kinetic, isotherm, thermodynamic, and SWOT analysis, non-living algae are generally more suitable for dyes and heavy metals removal, meanwhile living algae are appropriate for removal of organic matters and PhACs. Moreover, parametric effects on micropollutants removal are evaluated, highlighting that pH is critical for biodegradation activity. For selective pollutants, living and non-living algae show recommendable prospects as agents for the efficient cleaning of industrial wastewaters while awaiting further supporting discoveries in encouraging technology assurance and extensive applications.
    Matched MeSH terms: Waste Water
  17. Rathi BS, Kumar PS, Show PL
    J Hazard Mater, 2021 05 05;409:124413.
    PMID: 33183841 DOI: 10.1016/j.jhazmat.2020.124413
    Wastewater is water that has already been contaminated by domestic, industrial and commercial activity that needs to be treated before it could be discharged into some other water bodies to avoid even more groundwater contamination supplies. It consists of various contaminants like heavy metals, organic pollutants, inorganic pollutants and Emerging contaminants. Research has been doing on all types of contaminates more than a decade, but this emerging contaminants is the contaminants which arises mostly from pharmaceuticals, personal care products, hormones and fertilizer industries. The majority of emerging contaminants did not have standardized guidelines, but may have adverse effects on human and marine organisms, even at smaller concentrations. Typically, extremely low doses of emerging contaminants are found in the marine environment and cause a potential risk to the aquatic animals living there. When contaminants emerge in the marine world, they are potentially toxic and pose many risks to the health of both man and livestock. The aim of this article is to review the Emerging contaminate sources, detection methods and treatment methods. The purpose of this study is to consider the adsorption as a beneficial treatment of emerging contaminants also advanced and cost effective emerging contaminates treatment methods.
    Matched MeSH terms: Waste Water
  18. Rashid SS, Liu YQ
    Sci Total Environ, 2021 Feb 20;756:143849.
    PMID: 33248794 DOI: 10.1016/j.scitotenv.2020.143849
    The occurrence of various micropollutants such as pharmaceuticals personal care products, endocrine disrupting chemicals (PPCPs/EDCs) and metals in municipal wastewater, and their poor removal efficiencies can lead to toxicity impact on humans, and freshwater and terrestrial ecosystems. Life cycle assessment is an efficient and effective tool to evaluate the environmental impact of wastewater treatment plants, but guidelines for toxicity assessment are lacking due to the complexity. This study aims to evaluate both life cycle inventory by including metals and PEC, and life cycle toxicity assessment (LCIA) methods namely CML-IA, Recipe, USEtox, EDIP 2003 and IMPACT 2002+ in midpoint category with a large centralised wastewater treatment plant in Malaysia as a case study. The removal efficiencies of metals and PPCPs/EDCs in the wastewater ranged from 9% to 99% and no clear patterns were found about occurrence and removal efficiencies of metals and PPCPs/EDCs in developing and developed countries. The inclusion of metals and PPCPs/EDCs in effluent resulted in 76% increase in freshwater ecotoxicity potential (FEP) and 88% increase in terrestrial ecotoxicity potential (TEP) while only 4% increase in human toxicity potential (HTP). The results indicate the importance of including direct emissions such as metals and PPCPs/EDCs even in low-strength municipal wastewater for environmental toxicity assessment. The comparison of five LCIA methods suggests that HTP assessment is more challenging due to inconsistency between five LCIA methods while CML-IA, Recipe, and IMPACT 2002+ achieved consistent human toxicity and ecotoxicity assessment results in the WWTP. The results highlight the importance of sampling and inclusion of metals and PPCPs/EDCs data especially prioritised micropollutants for life cycle toxicity assessment and recommends LCIA methods for ecotoxicity assessment of WWTPs in the current scientific development situation on toxicity studies, which can provide guidance to researchers for life cycle toxicity assessment of wastewater treatment.
    Matched MeSH terms: Waste Water
  19. Rashid SS, Liu YQ, Zhang C
    Sci Total Environ, 2020 Dec 20;749:141465.
    PMID: 32827824 DOI: 10.1016/j.scitotenv.2020.141465
    Although nutrient removal and recovery from municipal wastewater are desirable to protect phosphorus resource and water-bodies from eutrophication, it is unclear how much environmental and economic benefits and burdens it might cause. This study evaluated the environmental and economic life cycle performance of three different upgraded Processes A, B and C with commercially available technologies for nutrient removal and phosphorus recovery based on an existing Malaysian wastewater treatment plant with a sequencing batch reactor technology and diluted municipal wastewater. It is found that the integration of nutrient removal, phosphorus recovery and electricity generation in all upgraded processes reduced eutrophication potential by 62-76%, and global warming potential by 7-22%, which, however, were gained at the cost of increases in human toxicity, acidification, abiotic depletion (fossil fuel) and freshwater ecotoxicity potentials by an average of 23%. New technologies for nutrient removal and phosphorus recovery are thus needed to achieve holistic rather than some environmental benefits at the expense of others. In addition, the study on two different functional units (FU), i.e. per m3 treated wastewater and per kg struvite recovered, shows that FU affected environmental assessment results, but the upgraded Process C had the least overall environmental burden with either of FUs, suggesting the necessity to use different functional units when comparing and selecting different technologies with two functions such as wastewater treatment and struvite production to confirm the best process configuration. The total life cycle costs of Processes A, B and C were 10.7%, 29.8% and 28.1%, respectively, higher than the existing process due to increased capital and operating costs. Therefore, a trade-off between environmental benefits and cost has to be balanced for technology selection or new integrated technologies have to be developed to achieve environmentally sustainable wastewater treatment economically.
    Matched MeSH terms: Waste Water
  20. Rasheed F, Zafar Z, Waseem ZA, Rafay M, Abdullah M, Salam MMA, et al.
    Int J Phytoremediation, 2020;22(3):287-294.
    PMID: 31468990 DOI: 10.1080/15226514.2019.1658711
    Conocarpus lancifolius is a fast-growing and drought tolerant tree species with phytoremediation potential in arid environments. The present study was conducted to evaluate the phytoaccumulation potential under wastewater treatment. The experiment was performed in a greenhouse where 3-month-old seedlings were irrigated with industrial wastewater and growth, biomass and physiological parameters were measured. Concentrations of zinc (Zn), lead (Pb), and cadmium (Cd) in leaves, shoots, and roots along with translocation and tolerance index were also determined. The results showed that under wastewater treatment total biomass increased from 24.2 to 31.5 g, net CO2 assimilation rate increased from 9.93 to 13.3 μmol m-2 s-1, and water use efficiency increased from 1.7 to 2.42. Similarly, heavy metals (Zn, Pb, and Cd) accumulation in stem, leaves, and roots increased significantly under wastewater treatment where the highest concentration of Zn, Pb and Cd was found in roots followed by leaves and stem, respectively. Tolerance index was found >1, and translocation factor of all heavy metals was found >1. The study revealed that phytoaccumulation potential of C. lancifolius was mainly driven by improved net CO2 assimilation rate and water use efficiency.
    Matched MeSH terms: Waste Water
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links