  1. Białobrzeska W, Dziąbowska K, Lisowska M, Mohtar MA, Muller P, Vojtesek B, et al.
    Biosensors (Basel), 2021 Jun 07;11(6).
    PMID: 34200338 DOI: 10.3390/bios11060184
    The detection of cancer antigens is a major aim of cancer research in order to develop better patient management through early disease detection. Many cancers including prostate, lung, and ovarian secrete a protein disulfide isomerase protein named AGR2 that has been previously detected in urine and plasma using mass spectrometry. Here we determine whether a previously developed monoclonal antibody targeting AGR2 can be adapted from an indirect two-site ELISA format into a direct detector using solid-phase printed gold electrodes. The screen-printed gold electrode was surface functionalized with the anti-AGR2 specific monoclonal antibody. The interaction of the recombinant AGR2 protein and the anti-AGR2 monoclonal antibody functionalized electrode changed its electrochemical impedance spectra. Nyquist diagrams were obtained after incubation in an increasing concentration of purified AGR2 protein with a range of concentrations from 0.01 fg/mL to 10 fg/mL. In addition, detection of the AGR2 antigen can be achieved from cell lysates in medium or artificial buffer. These data highlight the utility of an AGR2-specific monoclonal antibody that can be functionalized onto a gold printed electrode for a one-step capture and quantitation of the target antigen. These platforms have the potential for supporting methodologies using more complex bodily fluids including plasma and urine for improved cancer diagnostics.
    Matched MeSH terms: Limit of Detection
  2. A VBR, Yusop Z, Jaafar J, Aris AB, Majid ZA, Umar K, et al.
    J Pharm Biomed Anal, 2016 Sep 05;128:141-148.
    PMID: 27262107 DOI: 10.1016/j.jpba.2016.05.026
    In this study a sensitive and selective gradient reverse phase UPLC-MS/MS method was developed for the simultaneous determination of six process related impurities viz., Imp-I, Imp-II, Imp-III, Imp-IV, Imp-V and Imp-VI in darunavir. The chromatographic separation was performed on Acquity UPLC BEH C18 (50 mm×2.1mm, 1.7μm) column using gradient elution of acetonitrile-methanol (80:20, v/v) and 5.0mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously using multiple reaction monitoring (MRM) for the quantification of all six impurities in darunavir. The developed method was fully validated following ICH guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness and sample solution stability. The method was able to quantitate Imp-I, Imp-IV, Imp-V at 0.3ppm and Imp-II, Imp-III, and Imp-VI at 0.2ppm with respect to 5.0mg/mL of darunavir. The calibration curves showed good linearity over the concentration range of LOQ to 250% for all six impurities. The correlation coefficient obtained was >0.9989 in all the cases. The accuracy of the method lies between 89.90% and 104.60% for all six impurities. Finally, the method has been successfully applied for three formulation batches of darunavir to determine the above mentioned impurities, however no impurity was found beyond the LOQ. This method is a good quality control tool for the trace level quantification of six process related impurities in darunavir during its synthesis.
    Matched MeSH terms: Limit of Detection
  3. Abu-Bakar NB, Makahleh A, Saad B
    J Sep Sci, 2016 Mar;39(5):947-55.
    PMID: 26718308 DOI: 10.1002/jssc.201501109
    A novel microextraction method based on vortex- and CO2 -assisted liquid-liquid microextraction with salt addition for the isolation of furanic compounds (5-hydroxymethyl-2-furaldehyde, 5-methyl-2-furaldehyde, 2-furaldehyde, 3-furaldehyde, 2-furoic and 3-furoic acids) was developed. Purging the sample with CO2 was applied after vortexing to enhance the phase separation and mass transfer of the analytes. The optimum extraction conditions were: extraction solvent (volume), propyl acetate (125 μL); sample pH, 2.4; vortexing time, 45 s; salt concentration, 25% w/v and purging time, 5 min. The analytes were separated using an ODS Hypersil C18 column (250×4.6 mm i.d, 5 μm) under gradient flow. The proposed method showed good linearities (r(2) >0.999), low detection limits (0.08-1.9 μg/L) and good recoveries (80.7-122%). The validated method was successfully applied for the determination of the furanic compounds in concentrated juice (mango, date, orange, pomegranate, roselle, mangosteen and soursop) and dried fruit (prune, date and apricot paste) samples.
    Matched MeSH terms: Limit of Detection
  4. Kim JH, Chong CK, Sinniah M, Sinnadurai J, Song HO, Park H
    J Clin Virol, 2015 Apr;65:11-9.
    PMID: 25766980 DOI: 10.1016/j.jcv.2015.01.018
    BACKGROUND: Dengue is a mosquito-borne disease that causes a public health problem in tropical and subtropical countries. Current immunological diagnostics based on IgM and/or nonstructural protein 1 (NS1) antigen are limited for acute dengue infection due to low sensitivity and accuracy.
    OBJECTIVES: This study aimed to develop a one-step multiplex real-time RT-PCR assay showing higher sensitivity and accuracy than previous approaches.
    STUDY DESIGN: Serotype-specific primers and probes were designed through the multiple alignment of NS1 gene. The linearity and limit of detection (LOD) of the assay were determined. The assay was clinically validated with an evaluation panel that was immunologically tested by WHO and Malaysian specimens.
    RESULTS: The LOD of the assay was 3.0 log10 RNA copies for DENV-1, 2.0 for DENV-3, and 1.0 for DENV-2 and DENV-4. The assay showed 95.2% sensitivity (20/21) in an evaluation panel, whereas NS1 antigen- and anti-dengue IgM-based immunological assays exhibited 0% and 23.8-47.6% sensitivities, respectively. The assay showed 100% sensitivity both in NS1 antigen- and anti-dengue IgM-positive Malaysian specimens (26/26). The assay provided the information of viral loads and serotype with discrimination of heterotypic mixed infection.
    CONCLUSIONS: The assay could be clinically applied to early dengue diagnosis, especially during the first 5 days of illness and approximately 14 days after infection showing an anti-dengue IgM-positive response.
    Matched MeSH terms: Limit of Detection
  5. Ali N, Hashim NH, Shuib NS
    PMID: 25658149 DOI: 10.1080/19440049.2015.1011712
    The analysis of aflatoxins (B1, B2, G1 and G2) and ochratoxin A (OTA) was performed in processed spices marketed in Penang, Malaysia, using immunoaffinity columns and HPLC equipped with fluorescence detector (HPLC-FD). The processed powdered spices analysed include dried chilli, fennel, cumin, turmeric, black and white pepper, poppy seed, coriander, 'garam masala', and mixed spices for fish, meat and chicken curry. Two different studies were carried out. The limit of detection (LOD) was 0.01 ng g(-1) for each aflatoxin (AF) and 0.10 ng g(-1) for OTA (signal-to-noise ratio = 3:1). In the first study, 34 commercial processed spices analysed with a mean level, range and incidence of positive samples for total AF were 1.61 ng g(-1), 0.01-9.34 ng g(-1) and 85%, respectively, and for AFB1 were 1.38 ng g(-1), 0.01-7.68 ng g(-1) and 85%, respectively. The mean level, range and incidence of positive samples for OTA were 2.21 ng g(-1), 0.14-20.40 ng g(-1) and 79%, respectively. Natural co-occurrence of AF and OTA was found in 25 (74%) samples. In the second study of 24 commercial processed spices, the mean level, range and incidence of positive samples for total AF were 8.38 ng g(-1), 0.32-31.17 ng g(-1) and 88%, respectively, and for AFB1 were 7.31 ng g(-1), 0.32-28.43 ng g(-1) and 83%, respectively. Fifteen positive samples for total AF and two positive samples for OTA exceeded the permissible Malaysian limit of 5 ng g(-1). Contamination of both mycotoxins in spices may represent another route of exposure to consumers due to their frequent and prolonged consumption, as spices are common ingredients in popular dishes among Asian countries.
    Matched MeSH terms: Limit of Detection
  6. Ooi L, Heng LY, Mori IC
    Sensors (Basel), 2015;15(2):2354-68.
    PMID: 25621608 DOI: 10.3390/s150202354
    Biosensors fabricated with whole-cell bacteria appear to be suitable for detecting bioavailability and toxicity effects of the chemical(s) of concern, but they are usually reported to have drawbacks like long response times (ranging from hours to days), narrow dynamic range and instability during long term storage. Our aim is to fabricate a sensitive whole-cell oxidative stress biosensor which has improved properties that address the mentioned weaknesses. In this paper, we report a novel high-throughput whole-cell biosensor fabricated by immobilizing roGFP2 expressing Escherichia coli cells in a k-carrageenan matrix, for the detection of oxidative stress challenged by metalloid compounds. The E. coli roGFP2 oxidative stress biosensor shows high sensitivity towards arsenite and selenite, with wide linear range and low detection limit (arsenite: 1.0 × 10(-3)-1.0 × 10(1) mg·L(-1), LOD: 2.0 × 10(-4) mg·L(-1); selenite: 1.0 × 10(-5)-1.0 × 10(2) mg·L(-1), LOD: 5.8 × 10(-6) mg·L(-1)), short response times (0-9 min), high stability and reproducibility. This research is expected to provide a new direction in performing high-throughput environmental toxicity screening with living bacterial cells which is capable of measuring the bioavailability and toxicity of environmental stressors in a friction of a second.
    Matched MeSH terms: Limit of Detection
  7. Sairi M, Arrigan DW
    Talanta, 2015 Jan;132:205-14.
    PMID: 25476299 DOI: 10.1016/j.talanta.2014.08.060
    The behaviour of protonated ractopamine (RacH(+)) at an array of micro-interfaces between two immiscible electrolyte solutions (micro-ITIES) was investigated via cyclic voltammetry (CV) and linear sweep stripping voltammetry (LSSV). The micro-ITIES array was formed at silicon membranes containing 30 pores of radius 11.09±0.12 µm and pore centre-to-centre separation of 18.4±2.1 times the pore radius. CV shows that RacH(+) transferred across the water |1,6-dichlorohexane µITIES array at a very positive applied potential, close to the upper limit of the potential window. Nevertheless, CV was used in the estimation of some of the drug's thermodynamic parameters, such as the formal transfer potential and the Gibbs transfer energy. LSSV was implemented by pre-concentration of the drug, into the organic phase, followed by voltammetric detection, based on the back-transfer of RacH(+) from the organic to aqueous phase. Under optimised pre-concentration and detection conditions, a limit of detection of 0.1 µM was achieved. In addition, the impact of substances such as sugar, ascorbic acid, metal ions, amino acid and urea on RacH(+) detection was assessed. The detection of RacH(+) in artificial serum indicated that the presence of serum protein interferes in the detection signal, so that sample deproteinisation is required for feasible bioanalytical applications.
    Matched MeSH terms: Limit of Detection
  8. Misni M, Sathishkumar P, Ahamad R, MohdYusoff AR
    Environ Technol, 2015;36(17):2249-54.
    PMID: 25749108 DOI: 10.1080/09593330.2015.1025105
    Para-arsanilic acid (p-ASA) has been widely used in the poultry industry to promote growth and prevent dysentery. It is excreted unchanged in the manure and released into non-target sites causing organoarsenic pollution risk to the environment and living system. Therefore, simple and effective analytical strategies are demanded for determining the samples that contain p-ASA. However, direct determination of both p-ASA and ortho-arsanilic acid (o-ASA) using differential pulse cathodic stripping voltammetry (DPCSV) gives the similar voltammograms that directly hamper the analysis used by the DPCSV technique. In this study, a method to determine and differentiate p-ASA from o-ASA via diazotization and coupling reaction of the amine groups followed by the direct DPCSV determination of diazo compounds is presented. The diazotization reaction carried out at pH 1.5 and 0 ± 1°C for 10 min showed two reduction peaks in DPCSV at-70 mV and -440 mV vs. Ag/AgCl (KCl 3 M). However, when the diazotization reaction was performed at pH 12.5 and 0 ± 1°C for 40 min, a coloured azo compound was produced and the DPCSV showed only one reduction peak that appeared at -600 mV vs. Ag/AgCl (3 M of KCl). The results of this study show that only p-ASA compound gave a reduction peak, whereas o-ASA compound did not give any peak. The detection limit of p-ASA was found to be 4 × 10(-8 )M. As a result, the proposed electro-analytical technique might be a good candidate to determine and differentiate the p-ASA present in the poultry and environmental samples.
    Matched MeSH terms: Limit of Detection
  9. Yeap LL, Lo YL
    PLoS One, 2014;9(11):e111544.
    PMID: 25375249 DOI: 10.1371/journal.pone.0111544
    A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV) and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN) containing 1 µg/mL of internal standard (IS, diphenhydramine), then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm) column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40:60 v/v). Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ) for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD) was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.
    Matched MeSH terms: Limit of Detection
  10. Bahadoran M, Noorden AF, Mohajer FS, Abd Mubin MH, Chaudhary K, Jalil MA, et al.
    Artif Cells Nanomed Biotechnol, 2016;44(1):315-21.
    PMID: 25133457 DOI: 10.3109/21691401.2014.948549
    A new microring resonator system is proposed for the detection of the Salmonella bacterium in drinking water, which is made up of SiO2-TiO2 waveguide embedded inside thin film layer of the flagellin. The change in refractive index due to the binding of the Salmonella bacterium with flagellin layer causes a shift in the output signal wavelength and the variation in through and drop port's intensities, which leads to the detection of Salmonella bacterium in drinking water. The sensitivity of proposed sensor for detecting of Salmonella bacterium in water solution is 149 nm/RIU and the limit of detection is 7 × 10(-4)RIU.
    Matched MeSH terms: Limit of Detection
  11. Alqasaimeh M, Heng LY, Ahmad M, Raj AS, Ling TL
    Sensors (Basel), 2014 Jul 22;14(7):13186-209.
    PMID: 25054632 DOI: 10.3390/s140713186
    A new silica-gel nanospheres (SiO2NPs) composition was formulated, followed by biochemical surface functionalization to examine its potential in urea biosensor development. The SiO2NPs were basically synthesized based on sol-gel chemistry using a modified Stober method. The SiO2NPs surfaces were modified with amine (-NH2) functional groups for urease immobilization in the presence of glutaric acid (GA) cross-linker. The chromoionophore pH-sensitive dye ETH 5294 was physically adsorbed on the functionalized SiO2NPs as pH transducer. The immobilized urease determined urea concentration reflectometrically based on the colour change of the immobilized chromoionophore as a result of the enzymatic hydrolysis of urea. The pH changes on the biosensor due to the catalytic enzyme reaction of immobilized urease were found to correlate with the urea concentrations over a linear response range of 50-500 mM (R2 = 0.96) with a detection limit of 10 mM urea. The biosensor response time was 9 min with reproducibility of less than 10% relative standard deviation (RSD). This optical urea biosensor did not show interferences by Na+, K+, Mg2+ and NH4+ ions. The biosensor performance has been validated using urine samples in comparison with a non-enzymatic method based on the use of p-dimethylaminobenzaldehyde (DMAB) reagent and demonstrated a good correlation between the two different methods (R2 = 0.996 and regression slope of 1.0307). The SiO2NPs-based reflectometric urea biosensor showed improved dynamic linear response range when compared to other nanoparticle-based optical urea biosensors.
    Matched MeSH terms: Limit of Detection
  12. Fen YW, Yunus WM, Talib ZA, Yusof NA
    PMID: 25004894 DOI: 10.1016/j.saa.2014.06.081
    In this study, novel active nanolayers in combination with surface plasmon resonance (SPR) system for zinc ion (Zn(2+)) detection has been developed. The gold surface used for the SPR system was modified with the novel developed active nanolayers, i.e. chitosan and chitosan-tetrabutyl thiuram disulfide (chitosan-TBTDS). Both chitosan and chitosan-TBTDS active layers were fabricated on the gold surface by spin coating technique. The system was used to monitor SPR signal for Zn(2+) in aqueous media with and without sensitivity enhancement by TBTDS. For both active nanolayers, the shift of resonance angle is directly proportional to the concentration of Zn(2+) in aqueous media. The higher shift of resonance angle was obtained for chitosan-TBTDS active nanolayer due to a specific binding of TBTDS with Zn(2+). The chitosan-TBTDS active nanolayer enhanced the sensitivity of detection down to 0.1 mg/l and also induced a selective detection towards Zn(2+).
    Matched MeSH terms: Limit of Detection
  13. Wong YF, Makahleh A, Saad B, Ibrahim MN, Rahim AA, Brosse N
    Talanta, 2014 Dec;130:299-306.
    PMID: 25159413 DOI: 10.1016/j.talanta.2014.07.021
    A sensitive and rapid reversed-phase ultra performance liquid chromatographic (UPLC) method for the simultaneous determination of tocopherols (α-, β-, γ-, δ-), tocotrienols (α-, β-, γ-, δ-), α-tocopherol acetate and α-tocopherol nicotinate is described. The separation was achieved using a Kinetex pentafluorophenyl (PFP) column (150 × 2.1mm, 2.6 µm) with both photodiode array (PDA) and fluorescence (FL) detectors that were connected in series. Column was thermostated at 42°C. Under a gradient system consisting of methanol and water at a constant flow rate of 0.38 mL min(-1), all the ten analytes were well separated in less than 9.5 min. The method was validated in terms of linearity, limits of detection and quantitation, precision and recoveries. Calibration curves of the ten compounds were well correlated (r(2)>0.999) within the range of 100 to 25,000 μg L(-1) for α-tocopherol acetate and α-tocopherol nicotinate, 10 to 25,000 μg L(-1) for α-tocotrienol and 5 to 25,000 μg L(-1) for the other components. The method is simple and sensitive with detection limits (S/N, 3) of 1.0 to 3.0 μg L(-1) (FL detection) and 30 to 74 μg L(-1) (PDA detection). Relative standard deviations for intra- and inter-day retention times (<1%) and peak areas (≤ 4%) were obtained. The method was successfully applied to the determination of vitamin E in vegetable oils (extra virgin olive, virgin olive, pomace olive, blended virgin and refined olive, sunflower, soybean, palm olein, carotino, crude palm, walnut, rice bran and grape seed), margarines and supplements.
    Matched MeSH terms: Limit of Detection
  14. Usman MG, Rafii MY, Ismail MR, Malek MA, Latif MA
    Molecules, 2014 May 21;19(5):6474-88.
    PMID: 24853712 DOI: 10.3390/molecules19056474
    Research was carried out to estimate the levels of capsaicin and dihydrocapsaicin that may be found in some heat tolerant chili pepper genotypes and to determine the degree of pungency as well as percentage capsaicin content of each of the analyzed peppers. A sensitive, precise, and specific ultra fast liquid chromatographic (UFLC) system was used for the separation, identification and quantitation of the capsaicinoids and the extraction solvent was acetonitrile. The method validation parameters, including linearity, precision, accuracy and recovery, yielded good results. Thus, the limit of detection was 0.045 µg/kg and 0.151 µg/kg for capsaicin and dihydrocapsaicin, respectively, whereas the limit of quantitation was 0.11 µg/kg and 0.368 µg/kg for capsaicin and dihydrocapsaicin. The calibration graph was linear from 0.05 to 0.50 µg/g for UFLC analysis. The inter- and intra-day precisions (relative standard deviation) were <5.0% for capsaicin and <9.9% for dihydrocapsaicin while the average recoveries obtained were quantitative (89.4%-90.1% for capsaicin, 92.4%-95.2% for dihydrocapsaicin), indicating good accuracy of the UFLC method. AVPP0705, AVPP0506, AVPP0104, AVPP0002, C05573 and AVPP0805 showed the highest concentration of capsaicin (12,776, 5,828, 4,393, 4,760, 3,764 and 4,120 µg/kg) and the highest pungency level, whereas AVPP9703, AVPP0512, AVPP0307, AVPP0803 and AVPP0102 recorded no detection of capsaicin and hence were non-pungent. All chili peppers studied except AVPP9703, AVPP0512, AVPP0307, AVPP0803 and AVPP0102 could serve as potential sources of capsaicin. On the other hand, only genotypes AVPP0506, AVPP0104, AVPP0002, C05573 and AVPP0805 gave a % capsaicin content that falls within the pungency limit that could make them recommendable as potential sources of capsaicin for the pharmaceutical industry.
    Matched MeSH terms: Limit of Detection
  15. Azilawati MI, Hashim DM, Jamilah B, Amin I
    J Chromatogr A, 2014 Aug 1;1353:49-56.
    PMID: 24797394 DOI: 10.1016/j.chroma.2014.04.050
    In-house method validation was conducted to determine amino acid composition in gelatin by a pre-column derivatization procedure with the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate reagent. The analytical parameters revealed that the validated method was capable of selectively performing a good chromatographic separation for 18 amino acids in less than 40 min; the overall detection and quantitation limit for amino acids fell into ranges of 5.68-12.48 and 36.0-39.0 pmol/μl, respectively; the matrix effect was not observed, and the linearity range was 37.5-1000 pmol/μl. The accuracy (precision and recovery) analyses of the method were conducted under repeatable conditions on different days in random order. Method precision revealed by HorRat values was significantly less than 2, except for histidine with a precision of 2.19, and the method recoveries had a range of 80-115% except for alanine which was recovered at 79.4%. The findings were reproducible and accurately defined, and the method was found to be suited to routine analysis of amino acid composition in gelatin-based ingredients.
    Matched MeSH terms: Limit of Detection
  16. Omar MM, Wan Ibrahim WA, Elbashir AA
    Food Chem, 2014 Sep 1;158:302-9.
    PMID: 24731346 DOI: 10.1016/j.foodchem.2014.02.045
    A sol-gel hybrid sorbent, methyltrimethoxysilane-tetraethoxysilane (MTMOS-TEOS) was successfully used as new dispersive solid phase extraction (dSPE) sorbent material in the determination of acrylamide in several Sudanese foods and analysis using GC-MS. Several important dSPE parameters were optimised. Under the optimised conditions, excellent linearity (r(2)>0.9998) was achieved using matrix matched standard calibration in the concentration range 50-1000 μg kg(-1). The limits of detection (LOD) and limit of quantification ranged from 9.1 to 12.8 μg/kg and 27.8-38.9 μg/kg, respectively. The precision (RSD%) of the method was ⩽6.6% and recoveries of acrylamide obtained were in the range of 88-103%, (n=3). The LOD obtained is comparable with the LODs of primary secondary amine dSPE. The proposed MTMOS-TEOS dSPE method is direct and safe for acrylamide analysis, showed reliable method validation performances and good cleanup effects. It was successfully applied to the analysis of acrylamide in real food samples.
    Matched MeSH terms: Limit of Detection
  17. Shukor MY, Tham LG, Halmi MI, Khalid I, Begum G, Syed MA
    J Environ Biol, 2013 Sep;34(5):967-70.
    PMID: 24558814
    Near-real-ime assay is anassay method that the whole process from sampling until results could be obtained in approximately Iess than one hour. The ElIman assay for acetyl cholinesterase (AChE) has near real-time potential due to its simplicity and fast assay time. The commercial acetylcholinesterase from Electrophorus electricus is well known for its uses in insecticides detection. A lesser known fact is AChE is also sensitive to heavy metals. A near real-time inhibitive assay for heavy metals using AChE from this source showed promising results. Several heavy metals such as copper, silver and mercury could be etected with IC50 values of1.212, 0.1185 and 0.097 mg I-1, respectively. The Limits of Detection (LOD) for copper, silver and mercury were 0.01, 0.015 and 0.01 mg I-1, respectively. TheLimits of quantitation (LOQ) or copper, silver and mercury were 0.196, 0.112 and 0.025 mg I-1, respectively. The LOQvalues for copper, silver and mercury were well below the maximum permissible limit for these metal ions as outlined by Malaysian Department of Environment. A polluted location demonstrated near real-time applicability of the assay with variation oftemporal levels of heavy metals detected. The results show that AChE from Electrophorus electricus has the potential to be used as a near real-time biomonitoring tool for heavy
    Matched MeSH terms: Limit of Detection
  18. Arip MN, Heng LY, Ahmad M, Ujang S
    Talanta, 2013 Nov 15;116:776-81.
    PMID: 24148473 DOI: 10.1016/j.talanta.2013.07.065
    The characteristics of a potentiometric biosensor for the determination of permethrin in treated wood based on immobilised cells of the fungus Lentinus sajor-caju on a potentiometric transducer are reported this paper. The potentiometric biosensor was prepared by immobilisation of the fungus in alginate gel deposited on a pH-sensitive transducer employing a photocurable acrylic matrix. The biosensor gave a good response in detecting permethrin over the range of 1.0-100.0 µM. The slope of the calibration curve was 56.10 mV/decade with detection limit of 1.00 µM. The relative standard deviation for the sensor reproducibility was 4.86%. The response time of the sensor was 5 min at optimum pH 8.0 with 1.00 mg/electrode of fungus L. sajor-caju. The permethrin biosensor performance was compared with the conventional method for permethrin analysis using high performance liquid chromatography (HPLC), and the analytical results agreed well with the HPLC method (at 95% confidence limit). There was no interference from commonly used organophosphorus pesticides such as diazinon, parathion, paraoxon, and methyl parathion.
    Matched MeSH terms: Limit of Detection
  19. Lee TP, Saad B, Ng EP, Salleh B
    J Chromatogr A, 2012 May 11;1237:46-54.
    PMID: 22444432 DOI: 10.1016/j.chroma.2012.03.031
    Zeolite Linde Type L (LTL) crystals with different length, diameter and particle size (nanosized LTL, rod LTL, cylinder LTL and needle LTL) were synthesized, characterized and were used as sorbent in the micro-solid phase extraction of ochratoxin A (OTA) before the high performance liquid chromatography detection. Under the optimized conditions, the detection limits of OTA for coffee and cereal were 0.09 ng g(-1) and 0.03 ng g(-1), respectively, while the quantification limits were 0.28 ng g(-1) and 0.08 ng g(-1), respectively. The recoveries of OTA of coffee and cereal spiked at 0.5, 10 and 25 ng g(-1) ranged from 91.7 to 101.0%. The proposed method was applied to forty-five samples of coffee and cereal. The presence of OTA was found in twenty-five samples, ranging from 0.28 to 9.33 ng g(-1).
    Matched MeSH terms: Limit of Detection
  20. Al Azzam KM, Saad B, Tat CY, Mat I, Aboul-Enein HY
    J Pharm Biomed Anal, 2011 Dec 15;56(5):937-43.
    PMID: 21873014 DOI: 10.1016/j.jpba.2011.08.007
    A micellar electrokinetic chromatography method for the determination of sumatriptan succinate in pharmaceutical formulations was developed. The effects of several factors such as pH, surfactant and buffer concentration, applied voltage, capillary temperature, and injection time were investigated. Separation took about 5 min using phenobarbital as internal standard. The separation was carried out in reversed polarity mode at 20 °C, 26 kV and using hydrodynamic injection for 10s. Separation was achieved using a bare fused-silica capillary 50 μm×40 cm and background electrolyte of 25 mM sodium dihydrogen phosphate-adjusted with concentrated phosphoric acid to pH 2.2, containing 125 mM sodium dodecyl sulfate and detection was at 226 nm. The method was validated with respect to linearity, limits of detection and quantification, accuracy, precision and selectivity. The calibration curve was linear over the range of 100-2000 μg mL(-1). The relative standard deviations of intra-day and inter-day precision for migration time, peak area, corrected peak area, ratio of corrected peak area and ratio of peak area were less than 0.68, 3.48, 3.28, 2.97 and 2.83% and 2.01, 5.50, 4.46, 4.92 and 4.07%, respectively. The proposed method was successfully applied to the determinations of the analyte in tablet. Forced degradation studies were conducted by introducing a sample of sumatriptan succinate standard solution to different forced degradation conditions using neutral (water), basic (0.1 M NaOH), acidic (0.1 M HCl), oxidative (10% H(2)O(2)) and photolytic (exposure to UV light at 254 nm for 2 h). It is concluded that the stability-indicating method for sumatriptan succinate can be used for the analysis of the drug in various samples.