Objectives: The present study investigates the applicability of water hyacinth (Eichhornia crassipes), a tropical aquatic plant with reported heavy metal hyper-accumulation in microcosm floating wetland treatment systems designed to remediate AMD with copper (Cu) and cadmium (Cd) concentrations exceeding threshold limits.
Methods: Twelve water hyacinth samples were prepared with varying concentrations of Cu (1 mg/L, 2 mg/L, 4 mg/L) and Cd (0.005 mg/L, 0.01 mg/L, 0.02 mg/L). Water samples of 5 ml each were collected from each sample at 24-hour intervals for analysis with an atomic absorption spectrometer.
Results: Plant growth varied according to Cu and Cd concentrations and no plants survived for more than 14 days. There was a significant discrepancy in the rate at which the Cd concentrations abated. The rate of reduction was rapid for higher concentrations and after 24 hours a substantial reduction was achieved. There was a reduction in Cu concentration after the first 24-hour period, and after the next 24-hour period the concentrations were again elevated in the samples at initial concentrations of 2 mg/L and A4 mg/L. 4 mg/L Cu concentration was shown to be toxic to the plants, as they had low accumulations and rapid dying was evident.
Conclusions: Water hyacinth has the capability to reduce both Cu and Cd concentrations, except at an initial concentration of 4 mg/L of Cu, which was toxic to the plants.
Competing Interests: The authors declare no competing financial interests.
Methods: This project designed a safety vest incorporated with metal detectors which can provide immediate warning to the field workers when there is metal hazard around. This product has greater freedom of design via smart manufacturing as it involves the assembly of few commercially available parts into a single entity. Briefly, the metal detector is a do it yourself (DIY) kit, and the safety vest is purchasable from any local market. The DIY kit was connected to a copper coil and being sewed into the safety vest.
Results: The metal detector induces beeping sound when there is metal hazard around. A total of 121 engineering students were introduced to the prototype before being requested to answer a survey associated with the design. Respondents have rated >3.00/5.00 for the design simplicity, ease of usage, and light weight. Meanwhile, respondents suggested that the design should be further improved by increasing the metal detection range.
Conclusion: It is envisaged that the introduction of this smart safety vest will allow the workers to carry out their duties securely by reducing the accident rates. Particularly, such design is expected to reduce workplace accident especially during night time at construction sites where the visibility is low.