MATERIALS AND METHODS: A cross-sectional study was conducted in Luyang Health Clinic from 1st June 2020 to 3rd September 2020. A self-interviewed questionnaire comprises of three sections; sociodemographic, Wake Forest Physician Trust Scale (WFS) and Adherence to Refills and Medications Scale (ARMS) was completed by 281 respondents. Glycaemic control is based on the latest Hba1c profile of the respondents. Descriptive and nonparametric bivariate analysis were performed using IBM SPSS version 26.
RESULTS: The median (IQR) level of trust in physician was 43(8) out of a possible score range of 10 to 50. Trust in physician was correlated with treatment adherence (r=-0.12, p=0.048). There was no significant association between trust in physician with sociodemographic factors, which include age (p=0.33), gender (p=0.46), ethnicity (p=0.70), education level (p=0.50), and household income (p=0.37). Similarly, there was no significant association between the level of trust in physician with glycaemic control (p=0.709).
CONCLUSION: In conclusion, trust in physician was associated with treatment adherence but not with glycaemic control. In our local context, the glycaemic control could be due to other factors. Further studies should include a multicentre population to assess other potential factors that could contribute to glycaemic control.
PURPOSE: Due to the high percentage of affected pregnant women, it should be mandatory to evaluate glucose levels during pregnancy and there is a need for a continuous monitoring system.
METHODS: Herein, the investigators modified the interdigitated (di)electrodes (IDE) sensing surface to detect the glucose on covalently immobilized glucose oxidase (GOx) with the graphene. The characterization of graphene and gold nanoparticle (GNP) was performed by high-resolution microscopy.
RESULTS: Sensitivity was found to be 0.06 mg/mL and to enhance the detection, GOx was complexed with GNP. GNP-GOx was improved the sensitive detection twofold from 0.06 to 0.03 mg/mL, and it also displayed higher levels of current changes at all the concentrations of glucose that were tested. High-performance of the above IDE sensing system was attested by the specificity, reproducibility and higher sensitivity detections. Further, the linear regression analysis indicated the limit of detection to be between 0.02 and 0.03 mg/mL.
CONCLUSION: This study demonstrated the potential strategy with nanocomposite for diagnosing gestational diabetes mellitus.
METHOD: Data from 1,538 women were analyzed. At the first visit for prenatal care, the 50-gram glucose challenge test was followed by the 75-gram glucose tolerance test in those who screened positive. GDM was diagnosed based on the WHO (1999) criteria. Maternal complete blood count was obtained at the first visit, hospitalization for birth, and after birth. Receiver operator characteristic curves were generated to establish thresholds. Multivariable logistic regression analyses were performed to establish independent predictors of GDM.
RESULTS: GDM was diagnosed in 182/1,538 (11.8%). GDM was associated with hemoglobin level, hematocrit and erythrocyte count at the first visit for prenatal care only. Hemoglobin threshold at the first visit was established at 11.5 g/dl. After adjustment, high hemoglobin [AOR 1.5 (95% CI 1.0-2.1); p = 0.027] remained predictive of GDM.
CONCLUSIONS: High maternal hemoglobin level at the first prenatal visit is independently predictive of GDM.
Methods: hTenowere isolated from human hamstring tendon. Presence of insulin receptor beta (INSR-β) on normal tendon tissues and the hTeno monolayer culture were analyzed by immunofluorescence staining. The presence of Glucose Transporter Type 1 (GLUT1) and Glucose Transporter Type 4 (GLUT4) on the hTeno monolayer culture were also analyzed by immunofluorescence staining. Primary hTeno were treated with 0.008, 0.08, 0.8 and 8.0 µM of TNF-α, with and without insulin supplement. Outcome measures include 2-[N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl) amino]-2-deoxy-d-glucose (2-NBDG) assay to determine the glucose uptake activity; colourimetric total collagen assay to quantify the total collagen expression levels; COL-I ELISA assay to measure the COL-I expression levels and real-time qPCR to analyze the mRNA gene expressions levels of Scleraxis (SCX), Mohawk (MKX), type I collagen (COL1A1), type III collagen (COL3A1), matrix metalloproteinases (MMP)-9 and MMP-13 in hTeno when treated with TNF-α. Apoptosis assay for hTeno induced with TNF-α was conducted using Annexin-V FITC flow cytometry analysis.
Results: Immunofluorescence imaging showed the presence of INSR-β on the hTeno in the human Achilles tendon tissues and in the hTeno in monolayer culture. GLUT1 and GLUT4 were both positively expressed in the hTeno. TNF-α significantly reduced the insulin-mediated 2-NBDG uptake in all the tested concentrations, especially at 0.008 µM. Total collagen expression levels and COL-I expression levels in hTeno were also significantly reduced in hTeno treated with 0.008 µM of TNF-α. The SCX, MKX and COL1A1 mRNA expression levels were significantly downregulated in all TNF-α treated hTeno, whereas the COL3A1, MMP-9 and MMP-13 were significantly upregulated in the TNF-α treated cells. TNF-α progressively increased the apoptotic cells at 48 and 72 h.
Conclusion: At 0.008 µM of TNF-α, an IR condition was induced in hTeno, supported with the significant reduction in glucose uptake, as well as significantly reduced total collagen, specifically COL-I expression levels, downregulation of candidate tenogenic markers genes (SCX and MKX), and upregulation of ECM catabolic genes (MMP-9 and MMP-13). Development of novel IR model in hTeno provides an insight on how tendon homeostasis could be affected and can be used as a tool for further discovering the effects on downstream molecular pathways, as the implication for diabetic tendinopathy.