Displaying publications 1 - 20 of 38 in total

Abstract:
Sort:
  1. Mohd Ali, B., Nguan, D.K.C., Bashirah, I., Chan, K.M.
    MyJurnal
    Changes in tear protein concentrations may reflect ocular surface health. This study analyzes changes in tear protein concentrations of young Malays with dry eye (DE) and determines its association with the clinical findings. Methods: Subjects were screened using McMonnies questionnaire (MDEQ) and flourescein tear break up time (TBUT). Total tear protein concentration (TTPC) was determined using Bradford's technique and specific tear protein (sIgA, lysozyme, lactoferrin and human serum albumin (HSA)) concentrations were determined using SDS-PAGE. Parametric and nonparametric tests were used to compare means between groups. Spearman correlation was used to determine the association between variables measured. Results: A total of 42 subjects (21 DE and 21 NDE) were included. Mean MDEQ score for DE was 16.00±1.48 and NDE was 8.47±3.47. Mean TBUT for DE was 3.47±0.47s and NDE was 4.98±0.43s. Mean TTPC for DE and NDE was 9.84±2.40mg/ml and 8.96±1.84mg/ml respectively. Mean sIgA, lysozyme, lactoferrin and HSA for DE was 0.54±0.10mg/ml, 1.68±0.17mg/ml, 1.47±0.25mg/ml, 0.06±0.03mg/ml and for NDE was 0.57±0.09mg/ml, 2.04±0.19mg/ml, 1.75±0.23mg/ml, 0.06±0.03mg/ml accordingly. Significant differences were noted in MDEQ score (p=0.01), TBUT (p=0.01), lactoferrin (p=0.01) and lysozyme (p=0.01) but not in TTPC (p=0.19), HSA (p=0.74) and sIgA (p=0.24) between groups. Significant correlations were noted between TBUT with lactoferrin (r=0.02, p=0.02) and lysozyme (r=0.63, p=0.01) and between MDEQ score with lactoferrin (r=-0.34, p=0.02) and lysozyme (r=-0.64, p=0.01). Conclusions: There are changes in specific tear protein in dry eye patients, which correlate well with clinical results. Tear protein analysis may play an important role in the diagnosis of the dry eye.
  2. Nasidi, Y., Bamgbade S. Abu, J. A., Adeleke, A. Q., Ali, B.
    MyJurnal
    The construction organization contributes to the generation of large quantities of
    construction waste across Nigerian cities. Nigeria has been known to lack appropriate procedures for
    managing construction waste, and developers and their contractors are left with the collection and
    disposal of construction waste management, despite the fact that they are expected to embrace all
    administrative, financial, legal, planning, and technological functions involved in solutions to all
    problems of construction waste. Therefore, this leads to ineffective construction waste management.
    This paper examines the effect of the government policy on the relationship between organizational
    resources and construction waste management among construction organizations, in Abuja, Nigeria. A
    quantitative method of survey was used to obtain data from managers of construction project-based
    organizations in Abuja, Nigeria. A total of 310 questionnaires were administered and 178 usable
    questionnaires were returned, yielding 57.4 response rate. Partial least square Structural equation
    model (PLS-SEM) was used to analyse the data. The Cronbach’s Alpha value for the variables ranging
    from 0.885 to 0.972 indicates a very good reliability of the research instrument. It was found that all
    the hypotheses are significant at 5% significance level. It was found that while government policy
    moderates the relationship between the Transformational leadership as a dimension of organizational
    resources and construction waste management, it does not support organizational learning and staff
    training. Copyright © 2016 Penerbit Akademia Baru - All rights reserved.
  3. Mohd-Ali B, Chen LY
    Cont Lens Anterior Eye, 2021 02;44(1):72-75.
    PMID: 32624364 DOI: 10.1016/j.clae.2020.06.007
    PURPOSE: To analyse and compare the alterations in corneal endothelium morphology induced by different materials and durations of wearing soft contact lenses (CL) among young adults living in Kuala Lumpur.

    METHODS: Healthy soft CL wearers were invited to participate in this study. Visual acuity (VA) was measured using the Snellen chart, and subjective refraction was performed using cross-cylinder technique. Standard ocular assessments were conducted using a slit lamp biomicroscope and morphology of corneal endothelial cells (endothelial cell density, ECD, coefficient variation, COV, hexagonality, HEX and central corneal thickness, CCT) were evaluated using a non-contact specular microscope. Statistical analysis was conducted using ANOVA and data from the right eye only is included.

    RESULTS: A total of 72 subjects (32 SiHy and 40 HCL wearers) and 24 non-CL wearers (control) participated in this study. The gender distribution for study subjects was 13 males and 59 females, with a mean age 22.15 ± 1.84 years old. The mean refraction was -1.86 ± 1.25DS. The duration of wearing CL ranged from 1 to 9 years. Subjects were later divided into 2 groups following duration of CL wear: Group 1 (<5 years) and Group 2 (≥5 years) for analysis purposes. Statistical analysis showed significant alterations in ECD, COV and HEX of CL wearers (p 

  4. Mohd-Ali B, Tan XL
    PMID: 31861174 DOI: 10.3390/ijerph16245161
    BACKGROUND: Contact lenses (CLs) are more popular than spectacles for vision correction amongst the youth. Knowledge about the risks of wearing CLs is critical especially for those with poor access to public health education. This study investigates the patterns of use and level of knowledge about CL wear amongst teenagers living in rural areas in Selangor, Malaysia using a set of validated questionnaires.

    METHODS: A total of 8500 self-administered questionnaires were distributed in eight selected secondary schools. The results were analysed using descriptive statistics.

    RESULTS: A total of 2474 (29%) completed questionnaires were collected. The mean age of the respondents was 14.8 ± 1.5 years, and approximately 7.2% were CL wearers. The majority of the wearers were females (76.0%) and wore soft CLs (92.2%). Cosmetic purposes (58.1%) and comfort (24.6%) were the main reasons for wearing CLs. Many of the respondents purchased their lenses from optical shops (50.1%) and beauty accessory shops (15.6%), and approximately 10% did not disinfect their lenses properly. Regarding knowledge about CL care, approximately 56% of the respondents responded correctly.

    CONCLUSION: Half of the respondents do not have sufficient knowledge about the risks of wearing CLs. Thus, aggressive public health education aimed at teenagers is needed to prevent improper CL usage.

  5. Mohd-Ali B, Azmi N
    Clin Optom (Auckl), 2021;13:155-160.
    PMID: 34295203 DOI: 10.2147/OPTO.S277786
    PURPOSE: To investigate the wearing pattern and awareness about contact lens care among secondary school students in Kuala Lumpur.

    PATIENTS AND METHODS: This is a cross-sectional study using self-administered validated questionnaires. A total of 2500 questionnaires were distributed to secondary school students (aged 13 to 18 years) from 5 selected schools in Kuala Lumpur. Descriptive statistics were used to analyze the results.

    RESULTS: A total of 987 completed questionnaires were returned and analyzed. The response rate was 39.5%. Mean age of respondents was 15.5±2.5 years with 54.6% females. Around 9.9% of the respondents were contact lens wearers with female majority (78.6%) and the main reasons for wearing contact lenses were cosmesis (42.8%) and comfort (32.7%). Majority (92.2%) were soft contact lens wearers and daily wear (monthly disposable) is the preferred modality. Nevertheless, 42.4% purchased their lenses from unlicensed vendors and 18.4% rinsed their lenses using tap water. Regarding contact lens care, more than 50% of the respondents were not aware about the correct way of handling contact lenses.

    CONCLUSION: Soft contact lens wear is popular among the secondary school students in Kuala Lumpur but the level of practice and knowledge about CL care are unsatisfactory. Thus, health communication strategies and aggressive public ocular health education that can influence behavior changes in teenagers are needed to overcome these issues.

  6. Mohd-Ali B, Leong SF, Abdul-Mutalib H, Mohidin N
    Clin Ter, 2011;162(4):327-30.
    PMID: 21912820
    OBJECTIVE: Asians are known to have different tear characteristics compared to Caucasians that may affect contact lens wear. There are scanty research studies that have evaluated tears during continuous wear contact lens in Asia. The present study aims to evaluate changes in tears in subjects wearing continuous wear rigid gas permeable contact lens (CWRGP) for 6 months.
    MATERIALS AND METHODS: Thirty five neophyte subjects (21 females, 14 females) were recruited for this study. Subjects were fitted with CWRGP lenses with Dk of 163 on both eyes. Tear was evaluated using Phenol red thread test (PRT), tear break up time (TBUT) test and tear meniscus height (TMH) measurement. Non parametric and parametric analyses were used to compare the parameters.
    RESULTS: Values at baseline (BL) and six months (6M) were as follow: PRT, BL=19.10 ± 3.86 mm, 6M= 21.02 ± 4.27 mm, TBUT, BL= 8.58 ± 4.90 sec, 6M=8.08 ± 5.32 sec, TMH, BL= 0.38 ± 0.12 mm, 6M= 0.34 ± 0.07 mm. Statistical analysis showed significant difference in tear volume for PRT only at 6 months (p=0.007).
    CONCLUSION: Our analysis showed minimal change in the tear characteristics after six months of CWRGP lens wear, which indicated low impact of CWRGP contact lens on tears characteristics of Asian eyes. However, careful monitoring is required to prevent development of adverse events during contact lens wear.
  7. Ishak B, Mohd-Ali B, Mohidin N
    Clin Exp Optom, 2011 Sep;94(5):458-63.
    PMID: 21793918 DOI: 10.1111/j.1444-0938.2011.00621.x
    BACKGROUND: The monitoring and assessment of the upper tarsal conjunctiva can be enhanced by the use of a grading scale. The aim of this study was to categorise the appearance of normal tarsal conjunctiva among young adults in Malaysia using the Institute for Eye Research grading scale and to investigate inter- and intra-observer agreement.
    METHODS: The appearance of the upper tarsal conjunctiva of 416 non-contact lens wearing subjects aged between 19 to 24 years was assessed by two separate observers for roughness and redness in three separate zones using the Institute for Eye Research grading scale. The average grade for each zone and overall grade for roughness and redness were calculated. Inter- and intra-observer agreements were analysed.
    RESULTS: Subjects were categorised for ethnicity and the roughness and redness were calculated. No significant differences were found between Malay and Chinese eyes (p > 0.05). The average grades for the upper tarsal conjunctiva redness and roughness were 0.90 ± 0.25 and 0.86 ± 0.43, respectively. Significantly higher roughness scores were found in zone 1 compared to the other two zones (p = 0.03). Significant association was also found between tarsal conjunctiva redness and roughness (Spearman ρ= 0.45, p < 0.001). Correlation between redness and roughness with age (p = 0.48, p = 0.65) and gender (p = 0.30, p = 0.79) were not significant. Only 2.2 per cent of subjects had scores higher than 2.0 for roughness or redness. Inter- and intra-observer analysis showed good agreement between two observers during the study.
    CONCLUSION: The roughness and redness of normal tarsal conjunctiva among young adults in Malaysia were found to be less than two units. Results of this study might be beneficial in clinical trials using contact lenses where changes in the tarsal conjunctiva are commonly used as an outcome measure.
    Study site: Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
  8. Ahmad A, Mohd-Ali B, Ishak B
    Clin Optom (Auckl), 2018;10:109-113.
    PMID: 30319302 DOI: 10.2147/OPTO.S172272
    Purpose: Soft contact lens wear is most frequently associated with morphologic changes in corneal endothelial cells, but the data are scarce in Asians. This study aimed to evaluate changes in corneal endothelial cell morphology after 6 months of wearing soft hydrogel contact lenses (SH) in young myopic adults living in Kuala Lumpur.

    Patients and methods: Forty-eight subjects were included in the study, 24 were fitted with SH contact lenses (A) and the rest were prescribed with glasses (B). Refraction was conducted subjectively and standard contact lens fitting protocol was followed. Corneal endothelial cell morphology (endothelial cell density, ECD; coefficient of variation, COV; cells' hexagonality, HEX; and central corneal thickness, CCT) was evaluated using specular microscope. Data were collected at baseline and after 6 months of lens wear.

    Results: Mean age of all subjects was 21.23±1.30 years. All results are shown at baseline and 6 months, respectively. Mean refraction for A was -2.16±0.97 diopter sphere (DS) and -2.05±1.03 DS (P=0.49); for B was -2.72±1.51 DS and -2.73±1.51 DS (P=0.58). Mean ECD (cell/mm2) for A: 3104.19±237.30 and 3107.23±237.51 (P=0.07); for B: 3011.56±227.95 and 2983.83±244.55 (P=0.33). COV (%) for A: 46.52±8.63 and 48.53±10.65 (P=0.06); for B: 46.93±9.31 and 46.14±10.65 (P=0.88). HEX (%) for A: 46.21±10.12 and 45.15±10.01 (P=0.08); for B: 46.21±10.12 and 45.15±10.01 (P=0.12). CCT (µm) for A: 520.33±0.04 and 525.70±0.05 (P=0.41); for B: 532.00±0.04 µm and 530.00±0.05 µm (P=0.40).

    Conclusion: This study found no significant change in corneal endothelial cell morphology after 6 months of wearing SH contact lenses. This is probably due to better oxygen permeability of the contact lens material, good compliance, and short wearing period.
  9. Mohd-Ali B, Liew LY, Tai HJ, Wong YY
    Med J Malaysia, 2011 Mar;66(1):53-5.
    PMID: 23765144 MyJurnal
    OBJECTIVE: To evaluate tears of newly diagnosed keratoconus patients attending the Optometry clinic in Malaysia and to compare this with tears of normal myopic subjects.
    METHODS: The ocular surface of newly diagnosed keratoconus patients were evaluated using tear break up time (TBUT) test, non invasive tear break up time test (NIBUT) and Schirmer test. Twenty keratoconus patients (40 eyes) and 40 normal subjects (80 eyes) participated in this study.
    RESULTS: Significantly lower TBUT and NIBUT values were found in keratoconus patients than normal control subjects (p<0.05). Mean TBUT and NIBUT for keratoconus patients were 3.99±1.69s and 7.03±3.48s and for normal subjects were 7.24±4.39s and 13.67±10.81s respectively. However, no significant difference was detected in Schirmer test values. Mean values of Schirmer tests I and II for keratoconus patients were 20.52±10.66mm and 10.71±10.43mm and for normals were 23.83±11.34mm and 13.27±8.28mm accordingly.
    CONCLUSION: It was concluded from this study that keratoconus patients have poor tear stability which need to be considered appropriately during management of the patients.
    Study site: Optometry clinic, Pusat Perubatan Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
  10. Mohd-Ali B, Mohammed Z, Norlaila M, Mohd-Fadzil N, Rohani CC, Mohidin N
    Clin Exp Optom, 2006 May;89(3):150-4.
    PMID: 16637969 DOI: 10.1111/j.1444-0938.2006.00033.x
    Down syndrome is a common chromosomal anomaly. Few reported studies make reference to the ocular status in Asian children with Down syndrome. The purpose of this study was to determine the visual and binocular status of a sample of Down syndrome children in Malaysia.
  11. Abd Ali BM, Sharquie IK, Gorial FI
    Med J Malaysia, 2024 Nov;79(6):777-784.
    PMID: 39614798
    INTRODUCTION: Interleukin (IL)-41, a type of cytokine also known as Metrnl, is involved in the pathogenesis of various inflammatory and immune-related diseases. However, its role in Ankylosing Spondylitis (AS), a field yet to be explored, remains a mystery. This study therefore assesses the diagnostic utility of IL-41 in patients with AS and examines the correlations among IL-41 levels, disease activity, and patients' demographic and clinical data. Such novel insights could have significant implications for the diagnosis and management of AS.

    MATERIALS AND METHODS: Eighty-eight patients diagnosed with AS were enrolled from the Rheumatology Unit at Baghdad Teaching Hospital. Participants were categorized into two groups based on disease status: inactive (n = 44) and active (n = 44). Additionally, 44 matched healthy individuals were included as controls. Comprehensive medical histories were obtained, including disease duration, body mass index, sex, and age. Laboratory parameters related to the disease-such as C-reactive protein, human leukocyte antigen (HLA-B27), and rheumatoid factor-were also measured. Serum IL-41 levels were quantified using an enzyme-linked immunosorbent assay.

    RESULTS: The study revealed a significant difference in levels of IL-41 in patients with AS (17.721±0.705 ng/L) compared to controls (8.495±0.984 ng/L; P = 0.009). The mean serum IL-41 concentration was highest in the active group (23.037±5.268 ng/L), followed by the inactive group (12.411±1.672 ng/L; p = 0.001) and controls (8.495±0.984 ng/L). Serum IL-41 levels demonstrated strong validity for diagnosing AS, with a cutoff value of ≥ 9.35 ng/mL and an area under the curve of 0.991. The sensitivity, specificity, and accuracy were 97.7%, 79.5%, and 92.38%, respectively (p = 0.002).

    CONCLUSIONS: IL-41 is a potential new diagnostic biomarker for AS and associated with patient's disease activity. These insights could potentially transform the way we diagnose and manage AS, offering new avenues for improved patient care and outcomes.

  12. Valli H, Ahmad S, Chadda KR, Al-Hadithi ABAK, Grace AA, Jeevaratnam K, et al.
    Mech Ageing Dev, 2017 Oct;167:30-45.
    PMID: 28919427 DOI: 10.1016/j.mad.2017.09.002
    INTRODUCTION: Ageing and several age-related chronic conditions including obesity, insulin resistance and hypertension are associated with mitochondrial dysfunction and represent independent risk factors for atrial fibrillation (AF).

    MATERIALS AND METHODS: Atrial arrhythmogenesis was investigated in Langendorff-perfused young (3-4 month) and aged (>12 month), wild type (WT) and peroxisome proliferator activated receptor-γ coactivator-1β deficient (Pgc-1β-/-) murine hearts modeling age-dependent chronic mitochondrial dysfunction during regular pacing and programmed electrical stimulation (PES).

    RESULTS AND DISCUSSION: The Pgc-1β-/- genotype was associated with a pro-arrhythmic phenotype progressing with age. Young and aged Pgc-1β-/- hearts showed compromised maximum action potential (AP) depolarization rates, (dV/dt)max, prolonged AP latencies reflecting slowed action potential (AP) conduction, similar effective refractory periods and baseline action potential durations (APD90) but shortened APD90 in APs in response to extrasystolic stimuli at short stimulation intervals. Electrical properties of APs triggering arrhythmia were similar in WT and Pgc-1β-/- hearts. Pgc-1β-/- hearts showed accelerated age-dependent fibrotic change relative to WT, with young Pgc-1β-/- hearts displaying similar fibrotic change as aged WT, and aged Pgc-1β-/- hearts the greatest fibrotic change. Mitochondrial deficits thus result in an arrhythmic substrate, through slowed AP conduction and altered repolarisation characteristics, arising from alterations in electrophysiological properties and accelerated structural change.

  13. Saimon JA, Salim ET, Amin MH, Fakhri MA, Azzahrani AS, Ali ABM, et al.
    Sci Rep, 2024 Nov 15;14(1):28192.
    PMID: 39548127 DOI: 10.1038/s41598-024-73360-5
    This study successfully synthesized high-performance photodetectors based on Ag-WO3 core-shell heterostructures using a simple and economical two-step pulsed laser ablation in water method and has investigated the electrical characteristics of the Ag@WO3 nanocomposite heterojunction. The Hall effect tests indicate that the synthesized Ag@WO3 exhibits n-type conduction with a Hall mobility of 1.25 × 103 cm2V-1S-1. Dark current-voltage properties indicated that the created heterojunctions displayed rectification capabilities, with the highest rectification factor of around 1.71 seen at a 5 V bias. A photodetector's responsivity reveals the existence of two response peaks, which are situated in the ultraviolet and visible region. The photodetector demonstrates a rapid response time of less than 100 ms. The detectivity values for wavelengths of 350 nm and 490 nm were 35 × 1013 Jones and 28 × 1013 Jones, respectively. The n-Ag-WO3/n-Si photodetector achieved a maximum EQE of 11.5% in the ultraviolet wavelength when subjected to 3 V and illuminated with 350 nm (26 mW/cm2) light. The devices demonstrate rapid switching behavior with a rise time of 0.32 s and a fall time of 0.33 s. The time-dependent light response of a photodetector under illumination at 26 mW/cm2 is seen at a bias of 3 V. The light exhibits a rise and decay duration of 15 s, while the photocurrent gain is measured at 9µA. The photocurrent of devices exhibited a positive correlation with the incoming light intensity, suggesting that the junction has the potential to function as a photo detector.
  14. Ahmadi Hosseini SM, Mohidin N, Abolbashari F, Mohd-Ali B, Santhirathelagan CT
    Int Ophthalmol, 2013 Apr;33(2):139-45.
    PMID: 23138667 DOI: 10.1007/s10792-012-9654-x
    To evaluate corneal thickness and volume in subclinical and clinical keratoconus in Asian population with the aim of discriminating between normal and ectatic cornea. Eyes were placed into one of the following three groups: normal, subclinical, and mild-moderate keratoconus. Pentacam Scheimpflug imaging (Oculus Inc., Wetzlar, Germany) was performed for each participant to record thinnest corneal thickness, central corneal thickness, corneal volume (CV), peripheral corneal thickness (PCT) and percentage thickness increase (PTI) at 2, 4, 6, and 8 mm. The data were exported to SPSS for statistical analysis. Subjects comprised 52 normal, 15 subclinical keratoconus, and 32 mild-moderate clinical keratoconus eyes. Our results indicated that corneal thickness (CT) distribution, PTI, and CV in normal eyes were significantly different compared with subclinical and clinical keratoconus (P < .05). Overall, subclinical group exhibited lower CT distribution and volume, and higher PTI in comparison with normal eyes. However, they showed higher CT distribution and volume, and lower PTI compared with keratoconus group. In addition, there was a smaller change in PCT and PTI from the thinnest point of the cornea to the periphery. The results of the present study indicate that CT parameters and CV were significantly different in normal versus subclinical group and in normal versus keratoconus group. These findings could help clinicians to better discriminate between normal and ectatic cornea.
  15. Abolbashari F, Mohidin N, Ahmadi Hosseini SM, Mohd Ali B, Retnasabapathy S
    Cont Lens Anterior Eye, 2013 Aug;36(4):191-5.
    PMID: 23375190 DOI: 10.1016/j.clae.2013.01.005
    To assess changes in anterior segment parameters of keratoconus eyes at different stages of the disease in a sample of the Asian population.
  16. Mustapha I, Mohd Ali B, Rasid MF, Sali A, Mohamad H
    Sensors (Basel), 2015;15(8):19783-818.
    PMID: 26287191 DOI: 10.3390/s150819783
    It is well-known that clustering partitions network into logical groups of nodes in order to achieve energy efficiency and to enhance dynamic channel access in cognitive radio through cooperative sensing. While the topic of energy efficiency has been well investigated in conventional wireless sensor networks, the latter has not been extensively explored. In this paper, we propose a reinforcement learning-based spectrum-aware clustering algorithm that allows a member node to learn the energy and cooperative sensing costs for neighboring clusters to achieve an optimal solution. Each member node selects an optimal cluster that satisfies pairwise constraints, minimizes network energy consumption and enhances channel sensing performance through an exploration technique. We first model the network energy consumption and then determine the optimal number of clusters for the network. The problem of selecting an optimal cluster is formulated as a Markov Decision Process (MDP) in the algorithm and the obtained simulation results show convergence, learning and adaptability of the algorithm to dynamic environment towards achieving an optimal solution. Performance comparisons of our algorithm with the Groupwise Spectrum Aware (GWSA)-based algorithm in terms of Sum of Square Error (SSE), complexity, network energy consumption and probability of detection indicate improved performance from the proposed approach. The results further reveal that an energy savings of 9% and a significant Primary User (PU) detection improvement can be achieved with the proposed approach.
  17. Ali B, Tasirin SM, Aminayi P, Yaakob Z, Ali NT, Noori W
    Nanomaterials (Basel), 2018 Dec 14;8(12).
    PMID: 30558256 DOI: 10.3390/nano8121053
    Porous Ni, Ni-Co, Ni-Fe, and Ni-Cu magnetic alloys with a morphology similar to a giant barrel sponge were synthesized via a facile co-precipitation procedure and then by hydrogen reduction treatment. For the first time, the non-supported alloys with their unique morphology were employed in catalytic biogas decomposition (CBD) at a reaction temperature of 700 °C and 100 mL min-1 to produce syngas and carbon bio-nanofilaments, and the catalysts' behavior, CH₄ and CO₂ conversion, and the carbon produced during the reaction were investigated. All of the equimolar alloy catalysts showed good activity and stability for the catalytic biogas decomposition. The highest sustainability factor (0.66) and carbon yield (424%) were accomplished with the Ni-Co alloy without any significant inactivation for six hours, while the highest carbon efficiency of 36.43 was obtained with the Ni-Co catalyst, which is considered relatively low in comparison with industry standards, indicating a low carbon production process efficiency, possibly due to the relatively high biogas flow rate. The higher activity of the Ni-Co alloy catalyst was associated with the synergistic impact between nickel and cobalt, allowing the catalyst to maintain a high stability throughout the reaction period. Moreover, highly uniform, interwoven carbon bio-nanofilaments with a parallel and fishbone structure were achieved.
  18. Caracelli I, Zukerman-Schpector J, Stefani HA, Ali B, Tiekink ER
    Acta Crystallogr E Crystallogr Commun, 2015 Aug 1;71(Pt 8):o582-3.
    PMID: 26396808 DOI: 10.1107/S2056989015013353
    In the title compound, C13H15NO4, the oxopyrrolidin-3-yl ring has an envelope conformation, with the C atom bearing the acetate group being the flap. The acetate and phenyl groups are inclined with respect to the central ring, forming dihedral angles of 50.20 (12) and 87.40 (9)°, respectively, with the least-squares plane through the ring. The dihedral angle between the acetate group and the phenyl ring is 63.22 (8)°, indicating a twisted conformation in the mol-ecule. In the crystal, supra-molecular chains along the b axis are formed by (hy-droxy)O-H⋯O(ring carbon-yl) hydrogen bonds. The chains are consolidated into the three-dimensional architecture by C-H⋯O inter-actions.
  19. Salar U, Khan KM, Taha M, Ismail NH, Ali B, Qurat-Ul-Ain, et al.
    Eur J Med Chem, 2017 Jan 05;125:1289-1299.
    PMID: 27886546 DOI: 10.1016/j.ejmech.2016.11.031
    Current study is based on the biology-oriented drug synthesis (BIODS) of 2-(2-methyl-5-nitro-1H-imidazol-1-yl)ethyl aryl carboxylate derivatives 1-26, by treating metronidazole with different aryl and hetero-aryl carboxylic acids in the presence of 1,1'-carbonyl diimidazole (CDI) as a coupling agent. Structures of all synthetic derivatives were confirmed with the help of various spectroscopic techniques such as EI-MS, (1)H -NMR and (13)C NMR. CHN elemental analyses were also found in agreement with the calculated values. Synthetic derivatives were evaluated to check their β-glucuronidase inhibitory activity which revealed that except few derivatives, all demonstrated good inhibition in the range of IC50 = 1.20 ± 0.01-60.30 ± 1.40 μM as compared to the standard d-saccharic acid 1,4-lactone (IC50 = 48.38 ± 1.05 μM). Compounds 1, 3, 4, 6, 9-19, and 21-24 were found to be potent analogs and showed superior activity than standard. Limited structure-activity relationship is suggested that the molecules having electron withdrawing groups like NO2, F, Cl, and Br, were displayed better activity than the compounds with electron donating groups such as Me, OMe and BuO. To verify these interpretations, in silico study was also performed, a good correlation was observed between bioactivities and docking studies.
  20. Syed Mohd Dardin SF, Mohd-Ali B, Mohamad Shahimin M, Mohd Saman MN, Mohidin N
    Clin Optom (Auckl), 2024;16:107-114.
    PMID: 38596476 DOI: 10.2147/OPTO.S431608
    INTRODUCTION: Corneal characteristics are unique to each eye and can vary among different levels of refractive errors. However, minimal data are available in the literature on corneal characteristics in myopic Malay school children including the difference between the low myopic group and the moderate myopic group. Therefore, this study aims to determine the corneal characteristics of myopic Malay school children and their associations with axial length.

    METHODS: A total of eighty-four data samples were extracted from forty-two myopic Malay school children. Measurements of the central corneal thickness (CCT), corneal curvature, corneal diameter, and axial length were measured using Lenstar LS900, a non-contact optical biometer. Data were later stratified by the spherical equivalent refraction (SER) into a low myopic group and a moderate myopic group, and paired t-test were employed to determine the differences in the corneal characteristics between these two groups. Univariate and multivariate linear regressions were performed to identify factors that are significantly associated with axial length.

    RESULTS: There was no significant difference in the CCT, corneal curvature and corneal diameter between the low myopic group and the moderate myopic group (t82=0.015, P=0.99), (t82=-0.802, P=0.43) and (t82=-0.575, P=0.57), respectively. Pearson univariate correlation analysis found that axial length significantly correlated with corneal curvature (r=-0.765, P<0.001) and corneal diameter (r=0.614, P<0.001) but no significant correlation found with CCT (r=0.046, P=0.68). Multiple regression analysis showed that axial length was significantly associated with a flatter corneal curvature (P<0.001), older age (P<0.001) and larger corneal diameter (P=0.02).

    CONCLUSION: This study reported the corneal characteristics in myopic Malay school children and its associations with axial length. Results of this study can serve as a reference value for the myopic Malay schoolchild population.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links