Displaying publications 1 - 20 of 63 in total

Abstract:
Sort:
  1. Shah, N.N.A.K., Sulaiman, A., Sidek, N.S.M., Supian, N.A.M.
    MyJurnal
    The aim of the present work was to analyse the impact of ozone treatment on the physicochemical parameters and antioxidant capacity of citrus fruit juices (orange, lemon and lime) with different juice components (total soluble solids). Each sample was ozonated at different ozone treatment time, between 0 to 30 min with fixed ozone concentration of 600 mg/h. The synergistic effects of ozone treatment and the different types of juice were found to significantly affect the pH, total colour difference (TCD), pectin methylesterase (PME) activity, ascorbic acid (AA) and total phenolic content (TPC) of treated juices, while total soluble solids, turbidity and 2,2-diphenyl- 1-picrylhydrazyl (DPPH) assay were found to be unchanged. It was observed that PME activity decreased with treatment time and this is related to the decrease of juice turbidity (R2 = 0.86) and TCD (R2 = 0.78). Ascorbic acid showed an abrupt decrease in all the juices especially in orange juice with percentage loss of 85%. TPC also showed decreasing trend for all juices with maximum loss of 84.4% in lemon juice after 30 min of ozonation time. The present work also found that lemon juice could retain most of its antioxidant activities (DPPH 98.9%, TPC 96%, AA 86.7%) after 10 min of ozone treatment time in comparison to orange and lime juices.
  2. Sulaiman AS, Nordin S
    Med J Malaysia, 2005 Jul;60 Suppl C:41-4.
    PMID: 16381282
    Patellar thickness is an important consideration for resurfacing in total knee arthroplasty. A patella of 25 mm in thickness is not suitable for resurfacing using the currently available total knee systems. A cross sectional study on patellar thickness using plain radiographs was undertaken on 56 patients. It was observed that the average thickness of the bony part of the patella was 20.05 mm (range 17-23 mm). The actual thickness of cartilage varies from 2.0 to 5.5 mm (mean 3.2 mm). Thus the mean thickness of the patella was 23.2 mm (range 20.2-26.2 mm). The majority of our patients (73%) had patellar thickness of 24 mm or less. The patellar thickness had a significant correlation with the patient's height (R=0.5). Since the majority of our patients have thin patella, we are of the opinion that majority of our patients are not suitable for patellar resurfacing.
  3. Sulaiman AH, Husain R, Seluakumaran K
    Eur Arch Otorhinolaryngol, 2014 Jun;271(6):1463-70.
    PMID: 23812554 DOI: 10.1007/s00405-013-2612-z
    Although sound exposure from personal listening devices (PLDs) could potentially lead to noise-induced hearing loss (NIHL), the actual hearing risk associated with the use of these devices is still unclear. In this study, early hearing effects related to PLD usage were evaluated in 35 young adult PLD users (listening for >1 h/day, at >50% of the maximum volume setting of their devices) and their age- and sex-matched controls using a combination of conventional and extended high-frequency audiometry as well as transient-evoked otoacoustic emission (TEOAE) and distortion product of otoacoustic emission (DPOAE) measurements. The mean listening duration of the PLD users was 2.7 ± 1.0 h/day while their estimated average listening volume was 81.3 ± 9.0 dBA (free-field corrected). Typical signs of NIHL were not detected in the audiogram of PLD users and their audiometric thresholds at most of the conventional test frequencies (0.25-8 kHz) were comparable with those obtained from controls. However, compared with the controls, mean hearing thresholds of PLD users at many of the extended high-frequencies (9-16 kHz) were significantly higher. In addition, TEOAE and DPOAE amplitudes in users were reduced compared with controls. The deterioration of extended high-frequency thresholds and the decrease in DPOAE amplitudes were more evident in the users' right ears. These results indicate the presence of an early stage of hearing damage in the PLD user group. Preventive steps should be taken as the initial hearing damage in these users could eventually progress into permanent NIHL after many years of PLD use.
  4. Sulaiman AH, Seluakumaran K, Husain R
    Public Health, 2013 Aug;127(8):710-5.
    PMID: 23474376 DOI: 10.1016/j.puhe.2013.01.007
    To investigate listening habits and hearing risks associated with the use of personal listening devices among urban high school students in Malaysia.
  5. Logheswaren S, Sulaiman AR, Munajat I
    Malays Orthop J, 2017 Jul;11(2):82-84.
    PMID: 29021887 MyJurnal DOI: 10.5704/MOJ.1707.014
    The ideal size of intramedullary device to fix corrective osteotomy of proximal femur in abnormal bone in children and small patients may not be easily available. We report the successful use of Rush rod in combination with multiple Kirschner wires to fix the corrective osteotomy of coxa vara and shepherd crook deformity in two patients with osteogenesis imperfecta and fibrous dysplasia. The union was achieved on time, neck shaft angle and rotation were maintained.
  6. Shukrimi A, Sulaiman AR, Halim AY, Azril A
    Med J Malaysia, 2008 Mar;63(1):44-6.
    PMID: 18935732 MyJurnal
    Honey dressing has been used to promote wound healing for years but scanty scientific studies did not provide enough evidences to justify it benefits in the treatment of diabetic foot ulcers. We conducted a prospective study to compare the effect of honey dressing for Wagner's grade-II diabetic foot ulcers with controlled dressing group (povidone iodine followed by normal saline). Surgical debridement and appropriate antibiotics were prescribed in all patients. There were 30 patients age between 31 to 65-years-old (mean of 52.1 years). The mean healing time in the standard dressing group was 15.4 days (range 9-36 days) compared to 14.4 days (range 7-26 days) in the honey group (p < 0.005). In conclusion, ulcer healing was not significantly different in both study groups. Honey dressing is a safe alternative dressing for Wagner grade-II diabetic foot ulcers.
  7. Sulaiman AR, Nawaz H, Munajat I, Sallehudin AY
    J Orthop Surg (Hong Kong), 2007 Apr;15(1):84-6.
    PMID: 17429125
    We report a case of the Antley-Bixler syndrome in an 11-year-old girl. She presented with bilateral proximal femoral focal deficiency, right clubfoot, left radiohumeral synostosis, bilateral ear hypoplasia, cleft palate, tongue tie, missing teeth, congenital heart disease, a pelvic kidney with hydronephrosis, and mental retardation. Proximal femoral focal deficiency has never been reported before as a manifestation of Antley-Bixler syndrome. Her mother was exposed to radiation during an intravenous urogram done in the first trimester of pregnancy. Exposure to radiation has not been implicated as a cause of Antley-Bixler syndrome.
  8. Faisham WI, Sulaiman AR, Zulmni W
    Med J Malaysia, 2006 Feb;61 Suppl A:36-9.
    PMID: 17042227
    Femoral neck fracture non-unions often present with significant difficult treatment decision as regards to surgical options and the risk of complication. We present three cases of femoral neck non-union treated with double screw stabilization technique using sliding compression hip screw and anti-rotational screw. The rationale for opting to these simple implants in our setting is discussed.
  9. Vythilingam I, Jeffery J, Oothuman P, Abdul Razak AR, Sulaiman A
    PMID: 9322309
    A study was carried out to determine the distribution of cockroaches in two different housing areas with central sewerage or individual septic tanks in an urban area in Kuala Lumpur, Malaysia. Six species of cockroaches were present and of these Periplaneta americana and Periplaneta brunnea were found in greater abundance. Seventeen species of bacteria were isolated and of these Escherichia coli and Klebsiella p. pneumoniae were isolated in greatest numbers. Control measures carried out using lambda cyhalothrin showed that there was no significant difference between treated and control sites.
  10. Minhat FI, Husain ML, Sulaiman A
    Data Brief, 2019 Aug;25:104214.
    PMID: 31372481 DOI: 10.1016/j.dib.2019.104214
    The data presented herein were collected from the Straits of Malacca, along the west coast of Peninsular Malaysia. A 3.9 m core sample was retrieved from the Straits of Malacca in 2001. This core was continuously sub-sampled at 5-cm intervals between selected core depths of 220 cm and 380 cm. The 32 sub-samples obtained were analysed to understand the species composition of benthic Foraminifera in them and the changes in lithology during the Holocene. The data available in this article include the raw counts of different species of Foraminifera and the weight percentages of sediment of different grain sizes and organic matter at different depth. In addition, the estimated ages of the sediment samples are also provided. The chronostratigraphic framework of the core was based on radiocarbon-14 Accelerator Mass Spectrometry (AMS) dates estimated from three selected sediment intervals. The results of carbon dating were calibrated to calendar years (cal BC/AD) and calibrated radiocarbon years (cal BP). Calibration was done using the INTCAL program with a Delta R value of -19 ± 70.
  11. Sulaiman A, Omar K, Nasrudin MF
    J Imaging, 2019 Apr 12;5(4).
    PMID: 34460486 DOI: 10.3390/jimaging5040048
    In this era of digitization, most hardcopy documents are being transformed into digital formats. In the process of transformation, large quantities of documents are stored and preserved through electronic scanning. These documents are available from various sources such as ancient documentation, old legal records, medical reports, music scores, palm leaf, and reports on security-related issues. In particular, ancient and historical documents are hard to read due to their degradation in terms of low contrast and existence of corrupted artefacts. In recent times, degraded document binarization has been studied widely and several approaches were developed to deal with issues and challenges in document binarization. In this paper, a comprehensive review is conducted on the issues and challenges faced during the image binarization process, followed by insights on various methods used for image binarization. This paper also discusses the advanced methods used for the enhancement of degraded documents that improves the quality of documents during the binarization process. Further discussions are made on the effectiveness and robustness of existing methods, and there is still a scope to develop a hybrid approach that can deal with degraded document binarization more effectively.
  12. Sulaiman A, Farid M, Silva FV
    Food Sci Technol Int, 2017 Apr;23(3):265-276.
    PMID: 28359205 DOI: 10.1177/1082013216685484
    Worldwide, apple juice is the second most popular juice, after orange juice. It is susceptible to enzymatic browning spoilage by polyphenoloxidase, an endogenous enzyme. In this study, Royal Gala apple juice was treated by thermosonication (TS: 1.3 W/mL, 58 ℃, 10 min), pulsed electric field (PEF: 24.8 kV/cm, 60 pulses, 169 µs treatment time, 53.8 ℃) and heat (75 ℃, 20 min) and stored at 3.0 ℃ and 20.0 ℃ for 30 days. A sensory analysis was carried out after processing. The polyphenoloxidase activity, antioxidant activity and total color difference of the apple juice were determined before and after processing and during storage. The sensory analysis revealed that thermosonication and pulsed electric field juices tasted differently from the thermally treated juice. Apart from the pulsed electric field apple juice stored at room temperature, the processed juice was stable during storage, since the pH and soluble solids remained constant and fermentation was not observed. Polyphenoloxidase did not reactivate during storage. Along storage, the juices' antioxidant activity decreased and total color difference increased (up to 6.8). While the antioxidant activity increased from 86 to 103% with thermosonication and was retained after pulsed electric field, thermal processing reduced it to 67%. The processing increased the total color difference slightly. No differences in the total color difference of the juices processed by the three methods were registered after storage. Thermosonication and pulsed electric field could possibly be a better alternative to thermal preservation of apple juice, but refrigerated storage is recommended for pulsed electric field apple juice.
  13. Sulaiman A, Farid M, Silva FV
    Food Sci Technol Int, 2017 Jun;23(4):293-309.
    PMID: 28595485 DOI: 10.1177/1082013216685485
    Strawberry puree was processed for 15 min using thermal (65 ℃), high-pressure processing (600 MPa, 48 ℃), and ultrasound (24 kHz, 1.3 W/g, 33 ℃). These conditions were selected based on similar polyphenoloxidase inactivation (11%-18%). The specific energies required for the above-mentioned thermal, high-pressure processing, and power ultrasound processes were 240, 291, and 1233 kJ/kg, respectively. Then, the processed strawberry was stored at 3 ℃ and room temperature for 30 days. The constant pH (3.38±0.03) and soluble solids content (9.03 ± 0.25°Brix) during storage indicated a microbiological stability. Polyphenoloxidase did not reactivate during storage. The high-pressure processing and ultrasound treatments retained the antioxidant activity (70%-74%) better than the thermal process (60%), and high-pressure processing was the best treatment after 30 days of ambient storage to preserve antioxidant activity. Puree treated with ultrasound presented more color retention after processing and after ambient storage than the other preservation methods. For the three treatments, the changes of antioxidant activity and total color difference during storage were described by the fractional conversion model with rate constants k ranging between 0.03-0.09 and 0.06-0.22 day - 1, respectively. In resume, high-pressure processing and thermal processes required much less energy than ultrasound for the same polyphenoloxidase inactivation in strawberry. While high-pressure processing retained better the antioxidant activity of the strawberry puree during storage, the ultrasound treatment was better in terms of color retention.
  14. Alagdar GSA, Oo MK, Sengupta P, Mandal UK, Jaffri JM, Chatterjee B
    Int J Pharm Investig, 2017 12 1;7(3):142-148.
    PMID: 29184827 DOI: 10.4103/jphi.JPHI_54_17
    Background and Objective: One of the established strategies to improve solubility and dissolution rate of poorly water-soluble drugs is solid dispersion (SD). Polyethylene glycol (PEG) is used as common carrier despite its stability problem which may be overcome by the addition of hydrophobic polymer. The present research aimed to develop an SD formulation with ibuprofen, a poor water-soluble BCS Class II drug as active pharmaceutical ingredient (API) and PEG 4000-ethyl cellulose (EC) as binary carrier.

    Methods: Melt mixing SD method was employed using a ratio of API: binary carrier (1:3.5 w/w) (SDPE). Another SD was prepared using only PEG (SDP) as a carrier for comparative study. The developed formulation was evaluated using optical microscopy, scanning electron microscopy (SEM), determination of moisture content, differential scanning calorimetry (DSC), in vitro dissolution test, attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) and flow properties.

    Results: SEM and DSC indicated the conversion of crystalline ibuprofen to fine partly amorphous solid dispersion, which was responsible for the increase in dissolution rate of SD than a physical mixture. The release characteristics within 1 h from the higher to the lower value were the SDPE> SDP> physical mixture. Flow property evaluation using the angle of repose showed no difference between SD and PM. However, by Carr index and Hausner ratio, the flow properties of SDPE was excellent.

    Conclusion: The SD formulation with the PEG 4000-EC carrier can be effective to enhance in vitro dissolution of ibuprofen immediate release dosage form.

  15. Sulaiman S, Mokhtar MN, Naim MN, Baharuddin AS, Sulaiman A
    Appl Biochem Biotechnol, 2015 Feb;175(4):1817-42.
    PMID: 25427594 DOI: 10.1007/s12010-014-1417-x
    Nanobiocatalysis is a new frontier of emerging nanosized material support in enzyme immobilization application. This paper is about a comprehensive review on cellulose nanofibers (CNF), including their structure, surface modification, chemical coupling for enzyme immobilization, and potential applications. The CNF surface consists of mainly -OH functional group that can be directly interacted weakly with enzyme, and its binding can be improved by surface modification and interaction of chemical coupling that forms a strong and stable covalent immobilization of enzyme. The knowledge of covalent interaction for enzyme immobilization is important to provide more efficient interaction between CNF support and enzyme molecule. Enzyme immobilization onto CNF is having potential for improving enzymatic performance and production yield, as well as contributing toward green technology and sustainable sources.
  16. Talib AT, Mokhtar MN, Baharuddin AS, Sulaiman A
    Bioresour Technol, 2014 Oct;169:428-38.
    PMID: 25079208 DOI: 10.1016/j.biortech.2014.07.033
    The effect of different aeration rates on the organic matter (OM) degradation during the active phase of oil palm empty fruit bunch (EFB)-rabbit manure co-composting process under constant forced-aeration system has been studied. Four different aeration rates, 0.13 L min(-1) kg(DM)(-1),0.26 L min(-1) kg(DM)(-1),0.49 L min(-1) kg(DM)(-1) and 0.74 L min(-1) kg(DM)(-1) were applied. 0.26 L min(-1) kg(DM)(-1) provided enough oxygen level (10%) for the rest of composting period, showing 40.5% of OM reduction that is better than other aeration rates. A dynamic mathematical model describing OM degradation, based on the ratio between OM content and initial OM content with correction functions of moisture content, free air space, oxygen and temperature has been proposed.
  17. Justine M, Manaf H, Sulaiman A, Razi S, Alias HA
    Biomed Res Int, 2014;2014:640321.
    PMID: 24977154 DOI: 10.1155/2014/640321
    This study compares energy expenditure (EE), gait parameters (GP), and level of fatigue (LOF) between 5-minute walking with sharp turning (ST) and corner turning (CT). Data were obtained from 29 community-dwelling elderly (mean age, 62.7 ± 3.54 years). For 5 minutes, in ST task, participants walked on a 3-meter pathway with 2 cones placed at each end (180° turning), while in CT task, participants walked on a 6-meter pathway with 4 cones placed at 4 corners (90° turning). The physiological cost index, pedometer, and 10-point Modified Borg Dyspnoea Scale were used to measure EE (beats/min), GP (no of steps), and LOF, respectively. Data were analyzed by using independent t-tests. EE during ST (0.62 ± 0.21 beats/min) was significantly higher than CT (0.48 ± 0.17 beats/min) (P < 0.05). GP (434 ± 92.93 steps) and LOF (1.40 ± 1.11) in ST were found to be lower compared to GP (463 ± 92.18 steps) and LOF (1.54 ± 1.34) in CT (All, P > 0.05). Higher EE in ST could be due to the difficulty in changing to a 180° direction, which may involve agility and different turning strategies (step-turn or pivot-turn) to adjust the posture carefully. In CT, participants could choose a step-turn strategy to change to a 90° direction, which was less challenging to postural control.
  18. Damayanti A, Ujang Z, Salim MR, Olsson G, Sulaiman AZ
    Bioresour Technol, 2010 Jan;101(1):144-9.
    PMID: 19734044 DOI: 10.1016/j.biortech.2009.08.034
    Activated sludge models (ASMs) have been widely used as a basis for further model development in wastewater treatment processes. Values for parameters to be used are vital for the accuracy of the modeling approach. A continuous stirred tank reactor (CSTR), as open respirometer with continuous flow for 20 h is used in ASMs. The dissolved oxygen (DO) profile for 11 days was monitored. It was found the mass transfer coefficient K(La) is 0.3 h(-1) during lag and start feed phase and 0.01 h(-1) during stop feed phase, while the heterotrophic yield coefficient Y(H) is 0.44. Some of the chemical oxygen demand (COD) fractionations of palm oil mill effluent (POME) using respirometric test in ASM models are S(s) 50 mg/L, S(I) 16,600 mg/L, X(S) 25,550 mg/L, and X(I) 2,800 mg/L. The comparison of experimental and ASM1 from OUR concentration is found to fit well.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links