Displaying publications 1 - 20 of 78 in total

Abstract:
Sort:
  1. Chai CS, Chan SK, Kho SS, Ahmad A, Tie ST
    J Bronchology Interv Pulmonol, 2023 Jul 01;30(3):285-288.
    PMID: 37101325 DOI: 10.1097/LBR.0000000000000922
    Matched MeSH terms: Bronchoscopy*; Bronchoscopes
  2. Soo CI, Mak WW, Nasaruddin MZ, Ismail R, Ban AY, Abdul Rahaman JA
    Singapore Med J, 2024 Feb 01;65(2):119-122.
    PMID: 34617697 DOI: 10.11622/smedj.2021144
    Matched MeSH terms: Bronchoscopy
  3. Sooriyaghandan IV, Mohamad Jailaini MF, Nik Abeed NN, Ng BH, Yu-Lin AB, Shah SA, et al.
    BMC Pulm Med, 2023 Jan 10;23(1):10.
    PMID: 36627598 DOI: 10.1186/s12890-023-02304-y
    BACKGROUND: Patient comfort during invasive and therapeutic procedures is important. The use of virtual reality (VR) devices during flexible bronchoscopy (FB) as a method of distraction to increase patient tolerability and improve satisfaction has not been investigated. We aim to assess the satisfaction and tolerability of participants undergoing FB with or without VR.

    METHODS: This was a single-center, open-label study on patients undergoing bronchoscopy, randomized into the control and interventional (VR) groups. The control group received standard care during FB. The interventional group was given a VR device during FB showing nature videos with soothing instrumental music. Pain, breathlessness, and cough were evaluated using a 10 cm visual analogue scale administered before and after FB. Anxiety was assessed using the State-Trait Anxiety Inventory. Satisfaction questionnaire (5-point Likert scale) was given to participants post FB.

    RESULTS: Eighty participants enrolled, 40 in each arm. Median (IQR) satisfaction score in the VR group was 5.0 (3.0-5.0), and in the control group was 4.0 (3.0-5.0); (p 

    Matched MeSH terms: Bronchoscopy/adverse effects
  4. Kho SS, Nyanti LE, Chai CS, Chan SK, Tie ST
    Clin Respir J, 2021 Jun;15(6):595-603.
    PMID: 33113256 DOI: 10.1111/crj.13297
    BACKGROUND: Although radial endobronchial ultrasound (rEBUS) is an important verification tool in guided bronchoscopy, a navigational route was not provided. Manual airway mapping allows the bronchoscopist to translate the bronchial branching in computed tomography (CT) into a comparable bronchoscopic road map. We aimed to explore the feasibility of this technique in navigating conventional rEBUS bronchoscopy in the localisation of peripheral pulmonary lesion by determining navigation success and diagnostic yield.

    METHODS: Retrospective review of consecutive rEBUS bronchoscopy performed with a 6.2 mm conventional bronchoscope navigated via manual bronchial branch reading technique over 18 months.

    RESULTS: Ninety-eight target lesions were included. Median lesion size was 2.67 cm (IQR 2.22-3.38) with 96.9% demonstrating positive CT bronchus sign. Majority (86.7%) of lesions were situated in between the third and fifth airway generations. Procedure was performed with endotracheal intubation in 43.9% and fluoroscopy in 72.4%. 98.9% of lesions were successfully navigated and verified by rEBUS following the pre-planned airway road map. Bidirectional guiding device was employed in 29.6% of cases. Clinical diagnosis was secured in 88.8% of cases, majority of which were malignant disease. The discrepancy between navigation success and diagnostic yield was 10.1%. Target PPL located within five airway generations was associated with better diagnostic yield (95.1% vs. 58.8%, P 

    Matched MeSH terms: Bronchoscopy*
  5. Kho SS, Nyanti LE, Chai CS, Kho SK, Ismail AM, Voon PJ, et al.
    Respir Investig, 2023 Jul;61(4):473-477.
    PMID: 37182371 DOI: 10.1016/j.resinv.2023.04.003
    Peripheral transbronchial needle aspiration (pTBNA) allows the access of pulmonary nodules without bronchus sign but is limited to cytological examination. A 39-year-old man with left parotid carcinoma presented with an incidental lung nodule. Target localisation was performed with manual airway mapping, virtual bronchoscopic navigation, and pTBNA. Direct target validation using radial endobronchial ultrasound (rEBUS) was performed through the puncture defect. Targeted pinpoint biopsy with a 1.1 mm cryoprobe through the pTBNA puncture defect confirmed metastatic adenoid cystic carcinoma. Guided pTBNA with rEBUS validation followed by cryobiopsy of lung nodules without bronchus sign is potentially feasible for histological and molecular analyses.
    Matched MeSH terms: Bronchoscopy*
  6. Kho SS, Chai CS, Ho RL, Ismail AM, Tie ST
    Lancet, 2023 Oct 14;402(10410):1356.
    PMID: 37838440 DOI: 10.1016/S0140-6736(23)01906-2
    Matched MeSH terms: Bronchoscopy
  7. Majid AA
    Chest, 1991 Sep;100(3):862.
    PMID: 1889289
    A J-shaped suction catheter was tailored to facilitate aspiration of the right upper lobe bronchus during rigid bronchoscopy in pediatric patients. This suction catheter was used successfully in three patients.
    Matched MeSH terms: Bronchoscopy*; Bronchoscopes
  8. Zainudin BM, Wahab Sufarlan A, Rassip CN, Ruzana MA, Tay AM
    Med J Malaysia, 1991 Dec;46(4):309-13.
    PMID: 1840437
    The role of fiberoptic bronchoscopy for rapid diagnosis of pulmonary tuberculosis was examined among 74 patients who were suspected of having the disease but had negative sputum smear for acid fast bacilli. Bronchial brushing and washing were routinely performed in all subjects and bronchial biopsy was performed on abnormal mucosa in 7 of them. The diagnosis of pulmonary tuberculosis was confirmed in 44.6% of the patients studied from smear examination, culture, histology or the combination of them. Rapid diagnosis was achieved in 54.5% of the confirmed cases from smear or histology within a few days of examination. Two of the cases had concomitant bronchogenic carcinoma. We conclude that the fiberoptic bronchoscopy is a useful investigation for this group of patients as confirmation of the diagnosis can be made fairly rapidly in a significant proportion of them, hence the treatment can be started confidently.
    Matched MeSH terms: Bronchoscopy*
  9. Fauzi AR, Balakrishnan L, Rathor MY
    Med J Malaysia, 2003 Dec;58(5):729-34.
    PMID: 15190660
    A retrospective review of all bronchoscopy cases for investigation of lung cancer between January 1997 and December 1999 was done. The cases were included if endobronchial mass was visible (Group A) or when there was an abnormal mucosa and/or bronchial narrowing in the absence of a mass (Group B). All patients in Group A (n = 177) underwent endobronchial biopsy (EB) bronchial brushings (BB) and bronchial washings (BW). All cases in Group B underwent transbronchial biopsy (TBB), BB and BW. Only a small increase in the positive results for cancer was seen when cytology specimens (BB and BW) were added to EB (85.3% vs 88.1%, McNemar's P = 0.06) in Group A but there was a significant increase in Group B (37.3% vs 54.2%. McNemar's, P = 0.001). Therefore although cytology specimens did not significantly add to overall yield of positive results when endobronchial lesions were visible, when mass lesions were not visible, cytology specimens increased the yield by 16.9%.
    Study site: Chest clinic, Hospital Sultanah Aminah (HSA), Johor Bahru, Johor, Malaysia
    Matched MeSH terms: Bronchoscopy*
  10. Faisal AH, Sopian AW, Tidi H
    Med J Malaysia, 2017 08;72(4):241-243.
    PMID: 28889136 MyJurnal
    Electromagnetic navigational bronchoscopy (ENB), one of the methods of navigational bronchoscopy is an advanced diagnostic tool allowing tissue sampling at the lung peripheries which were previously accessible only by computed tomography (CT) guidance or video-assisted thoracoscopic surgery (VATS). We report a 53-year-old man who presented with a cough and dyspnea with constitutional symptoms for one month. CT thorax revealed multiple bilateral peripheral lung nodules and there were no endobronchial lesions on flexible bronchoscopy. ENB was performed using a loan machine from Veran navigational technology. Biopsy successfully revealed small cell carcinoma of the lung thus preventing him from undergoing a more invasive diagnostic procedure. This case highlights the utility of ENB in the evaluation of peripheral lung nodules that were inaccessible by conventional bronchoscopy. This is one of the first few successful applications of Veran ENB in Asia.
    Matched MeSH terms: Bronchoscopy/methods
  11. Su SC, Masters IB, Buntain H, Frawley K, Sarikwal A, Watson D, et al.
    Pediatr Pulmonol, 2017 04;52(4):480-486.
    PMID: 27641078 DOI: 10.1002/ppul.23606
    INTRODUCTION: Flexible bronchoscopy (FB) is the current gold standard for diagnosing tracheobronchomalacia. However, it is not always feasible and virtual bronchoscopy (VB), acquired from chest multi-detector CT (MDCT) scan is an alternative diagnostic tool. We determined the sensitivity, specificity, and positive and negative predictive values of VB compared to FB in diagnosing tracheobronchomalacia.

    METHODS: Children aged <18-years scheduled for FB and MDCT were recruited. FB and MDCT were undertaken within 30-min to 7-days of each other. Tracheobronchomalacia (mild, moderate, severe, very severe) diagnosed on FB were independently scored by two pediatric pulmonologists; VB was independently scored by two pairs (each pair = pediatric pulmonologist and radiologist), in a blinded manner.

    RESULTS: In 53 children (median age = 2.5 years, range 0.8-14.3) evaluated for airway abnormalities, tracheomalacia was detected in 37 (70%) children at FB. Of these, VB detected tracheomalacia in 20 children, with a sensitivity of 54.1% (95%CI 37.1-70.2), specificity = 87.5% (95%CI 60.4-97.8), and positive predictive value = 90.9% (95%CI 69.4-98.4). The agreement between pediatric pulmonologists for diagnosing tracheomalacia by FB was excellent, weighted κ = 0.8 (95%CI 0.64-0.97); but only fair between the pairs of pediatric pulmonologists/radiologists for VB, weighted κ = 0.47 (95%CI 0.23-0.71). There were 42 cases of bronchomalacia detected on FB. VB had a sensitivity = 45.2% (95%CI 30.2-61.2), specificity = 95.5% (95%CI 94.2-96.5), and positive predictive value = 23.2 (95%CI 14.9-34.0) compared to FB in detecting bronchomalacia.

    CONCLUSION: VB cannot replace FB as the gold standard for detecting tracheobronchomalacia in children. However, VB could be considered as an alternative diagnostic modality in children with symptoms suggestive of tracheobronchomalacia where FB is unavailable. Pediatr Pulmonol. 2017;52:480-486. © 2016 Wiley Periodicals, Inc.

    Matched MeSH terms: Bronchoscopy/instrumentation*
  12. Jalleh RD, Kuppusamy I, Parameswary V, Yeow CS
    Singapore Med J, 1993 Feb;34(1):55-7.
    PMID: 8266131
    We report our experience on the use of fibreoptic bronchoscopy in the diagnosis of pulmonary tuberculosis. The case records of 1,274 patients who underwent fibreoptic bronchoscopy at the National Tuberculosis Centre, Kuala Lumpur, Malaysia during a three-year period were reviewed. In 120 of them the final diagnosis was tuberculosis. Bronchoscopy confirmed the diagnosis in 37 patients (30.8%). This was achieved by bronchial aspiration for culture in 26 patients (70.3%) and bronchial biopsy for histopathology in 11 patients (29.7%). It was the exclusive method of confirmation in 16 patients (13.3%). Sputum culture was positive in 62 patients (51.7%) including 41 patients (34.2%) in whom bronchoscopy was unhelpful. Six patients had diagnosis confirmed by other means while in 36 others (30%) it was based on clinical features and supportive basic investigations. There were no complications noted. We conclude that while sputum examination remains the mainstay for diagnosing pulmonary tuberculosis, fibreoptic bronchoscopy serves as a safe and useful adjunct.
    Matched MeSH terms: Bronchoscopy*; Bronchoscopes
  13. Kho SS, Chai CS, Nyanti LE, Ismail AMB, Tie ST
    BMC Pulm Med, 2020 Jun 03;20(1):158.
    PMID: 32493437 DOI: 10.1186/s12890-020-01199-3
    BACKGROUND: Lung cancer is frequently situated peripherally in the upper lobes of the lung. Acquiring adequate tissue from this difficult-to-reach area remains a challenge. Transbronchial cryobiopsy (TBCB) has the ability to acquire larger specimens, but the rigidity of the standard 1.9 mm and 2.4 mm cryoprobes frequently poses challenges when used with a guide sheath (GS). The novel 1.1 mm cryoprobe, being both smaller and more flexible, may address this limitation. We describe the usage of this 1.1 mm flexible cryoprobe with GS in the biopsy of solitary pulmonary nodules (SPN) in the apical segment of the upper lobe in two cases.

    CASE REPORT: Both procedures were conducted with advanced airway under total intravenous anaesthesia. 2.6 mm GS was used in combination with a 2.2 mm rEBUS probe, using a therapeutic bronchoscope. Case 1 describes a SPN in the apical segment of the right upper lobe that was inconclusive by forceps biopsy due to GS displacement and inadequate biopsy depth. A steerable GS combined with the novel cryoprobe subsequently overcame this issue. Case 2 describes a SPN in the apical segment of the left upper lobe in which the standard cryoprobe failed to advance through the GS due to steep angulation. It also highlights with shorter activation time, the novel cryoprobe enable biopsied tissue to be retrieved through the GS while the bronchoscope-GS remains wedgend in the airway segment. There were no bleeding or pneumothorax complications in both cases, and histopathological examination confirmed adenocarcinoma of the lung.

    CONCLUSION: The 1.1 mm flexible cryoprobe in combination with GS and therapeutic bronchoscope offers an option to acquire adequate tissue in difficult-to-reach regions in the lung such as the apical segment of upper lobes. Further prospective series to evaluate its performance and safety in SPN biopsy is highly anticipated.

    Matched MeSH terms: Bronchoscopy/instrumentation*
  14. Ramarmuty HY, Huan NC, Nyanti LE, Khoo TS, Renganathan T, Manoh AZ, et al.
    Ther Adv Respir Dis, 2024;18:17534666241231122.
    PMID: 38357899 DOI: 10.1177/17534666241231122
    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established minimally invasive method for the diagnosis of benign and malignant conditions. Continuous efforts are underway to improve the material adequacy of EBUS-TBNA, including the introduction of a new technique called EBUS-guided transbronchial nodal cryobiopsy (EBUS-TBNC). This method allows for the retrieval of larger and well-preserved histologic samples from the mediastinum. We present a case series of four patients who underwent combined EBUS-TBNA and EBUS-TBNC procedures in our centre. All procedures were performed under general anaesthesia using a convex probe EBUS scope (Pentax EB-1970UK). Two patients were diagnosed with malignancy and two with benign disorders (silicosis and tuberculosis). In the malignant cases, both EBUS-TBNA/cell block and cryobiopsy provided a diagnosis but cryobiopsy yielded more material for ancillary tests in one patient. However, in the benign cases, there was discordance between EBUS-TBNA/cell block and cryobiopsy. Only cryobiopsy detected granuloma in the patient with TB (tuberculosis), and in the patient with silicosis, TBNC provided a better overall histological evaluation, leading to a definitive diagnosis. No complications were observed. This case series supports the potential diagnostic value of combining EBUS-TBNA and EBUS-TBNC, particularly in benign mediastinal lesions (granulomatous diseases), and in cases requiring additional molecular tests in cancer diagnosis.
    Matched MeSH terms: Bronchoscopy/methods
  15. Mohamad I, Haron A
    Med J Malaysia, 2013 Apr;68(2):164-5.
    PMID: 23629566 MyJurnal
    Papillary thyroid carcinoma is a common thyroid malignancy reported world wide. It affects females more commonly in the 4th to 6th decades of life. The patients usually present with a painless anterior neck mass and occasionally with lymph node involvement. We report a case of an elderly male who presented with hoarseness and hemoptysis, which warranted bronchoscopy. Biopsy of the intraluminal tracheal mass revealed the diagnosis of papillary thyroid carcinoma. Computed tomography scan of the neck confirmed the presence of the primary lesion in the right thyroid lobe with invasion into the adjacent trachea and esophagus.
    Matched MeSH terms: Bronchoscopy
  16. Kuan, Y.C., How, S.H., Ng, T.H., Mohammed Fauzi, A.R., Liam, C.K., Mohd Ashri, A.
    MyJurnal
    This case report describes a rigid bronchoscopy-assisted placement of a silicone airway Y-stent in a patient who developed tracheobronchomalacia following repeated dilatations for post-tuberculous airway stenosis. This is the first report of an airway Y-stent insertion in Malaysia.
    Matched MeSH terms: Bronchoscopy
  17. Huan NC, Ng KL, Tang JT, Kua HN, Daut UN, Muhammad NA, et al.
    Ann Acad Med Singap, 2020 12;49(12):1013-1017.
    PMID: 33463660 DOI: 10.47102/annals-acadmedsg.2020364
    The ongoing pandemic of COVID-19 has presented multiple challenges to global healthcare services, dictating changes in almost every aspect of daily medical practice. Performing aerosol generating procedures (AGPs) in the field of interventional pulmonology can lead to profound formation of aerosols, leading to a high risk of infection among healthcare workers (HCWs). We share our experiences on performing AGPs in the midst of a COVID-19 pandemic by focusing on changes in AGP practices. In a pandemic, HCWs ought to adapt to the ever-changing situation and use available resources to provide the best possible healthcare to patients, ensure safety of staff, and continue medical education of future pulmonologists.
    Matched MeSH terms: Bronchoscopy/methods*; Bronchoscopy/trends
  18. Narhari R, Nazaruddin Wan Hassan WM, Mohamad Zaini RH, Che Omar S, Abdullah Nik Mohamad N, Seevaunnamtum P
    Anaesthesiol Intensive Ther, 2020;52(5):377-382.
    PMID: 33327695 DOI: 10.5114/ait.2020.101387
    INTRODUCTION: The choice of endotracheal tube (ETT) is important for successful orotracheal fibreoptic intubation (OFI). The aim of this study was to compare the use of the Parker flex tip (PFT) with the unoflex reinforced (UFR) ETT during OFI.

    MATERIAL AND METHODS: A total of 58 patients who underwent elective surgery under general anaesthesia were randomised to two ETT groups, the PFT group (n = 29) and the UFR group (n = 29), for OFI in simulated difficult intubation patients using a rigid cervical collar. After successful standardised induction and relaxation, OFI and railroading of selected ETT were subsequently performed by a similarly experienced practitioner. Ease of insertion, degree of manipulation, time to successful intubation, post-intubation complications and haemodynamic changes were recorded for both groups.

    RESULTS: he percentage of easy intubation was comparable between both groups with a slightly higher percentage in the UFR group than the PFT group (69.0% vs. 62.0%; P = 0.599). Degree of manipulation was also comparable between the two groups; the percentage of cases in which manipulation was not required was slightly higher in the UFR group than the PFT group (69.0% vs. 62.1%; P = 0.849). Time to successful intubation was also comparable between the groups, although the time was slightly shorter for the UFR group than the PFT group (56.9 s ± 39.7 s vs. 63.9 s ± 36.9 s; P = 0.488). There were also no significant differences in other parameters.

    CONCLUSIONS: The Parker flex tip ETT was comparable to the unoflex reinforced ETT for OFI in simulated difficult airway patients.

    Matched MeSH terms: Bronchoscopy/instrumentation; Bronchoscopy/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links