METHODS: This was a single-center, open-label study on patients undergoing bronchoscopy, randomized into the control and interventional (VR) groups. The control group received standard care during FB. The interventional group was given a VR device during FB showing nature videos with soothing instrumental music. Pain, breathlessness, and cough were evaluated using a 10 cm visual analogue scale administered before and after FB. Anxiety was assessed using the State-Trait Anxiety Inventory. Satisfaction questionnaire (5-point Likert scale) was given to participants post FB.
RESULTS: Eighty participants enrolled, 40 in each arm. Median (IQR) satisfaction score in the VR group was 5.0 (3.0-5.0), and in the control group was 4.0 (3.0-5.0); (p
METHODS: Retrospective review of consecutive rEBUS bronchoscopy performed with a 6.2 mm conventional bronchoscope navigated via manual bronchial branch reading technique over 18 months.
RESULTS: Ninety-eight target lesions were included. Median lesion size was 2.67 cm (IQR 2.22-3.38) with 96.9% demonstrating positive CT bronchus sign. Majority (86.7%) of lesions were situated in between the third and fifth airway generations. Procedure was performed with endotracheal intubation in 43.9% and fluoroscopy in 72.4%. 98.9% of lesions were successfully navigated and verified by rEBUS following the pre-planned airway road map. Bidirectional guiding device was employed in 29.6% of cases. Clinical diagnosis was secured in 88.8% of cases, majority of which were malignant disease. The discrepancy between navigation success and diagnostic yield was 10.1%. Target PPL located within five airway generations was associated with better diagnostic yield (95.1% vs. 58.8%, P
METHODS: Children aged <18-years scheduled for FB and MDCT were recruited. FB and MDCT were undertaken within 30-min to 7-days of each other. Tracheobronchomalacia (mild, moderate, severe, very severe) diagnosed on FB were independently scored by two pediatric pulmonologists; VB was independently scored by two pairs (each pair = pediatric pulmonologist and radiologist), in a blinded manner.
RESULTS: In 53 children (median age = 2.5 years, range 0.8-14.3) evaluated for airway abnormalities, tracheomalacia was detected in 37 (70%) children at FB. Of these, VB detected tracheomalacia in 20 children, with a sensitivity of 54.1% (95%CI 37.1-70.2), specificity = 87.5% (95%CI 60.4-97.8), and positive predictive value = 90.9% (95%CI 69.4-98.4). The agreement between pediatric pulmonologists for diagnosing tracheomalacia by FB was excellent, weighted κ = 0.8 (95%CI 0.64-0.97); but only fair between the pairs of pediatric pulmonologists/radiologists for VB, weighted κ = 0.47 (95%CI 0.23-0.71). There were 42 cases of bronchomalacia detected on FB. VB had a sensitivity = 45.2% (95%CI 30.2-61.2), specificity = 95.5% (95%CI 94.2-96.5), and positive predictive value = 23.2 (95%CI 14.9-34.0) compared to FB in detecting bronchomalacia.
CONCLUSION: VB cannot replace FB as the gold standard for detecting tracheobronchomalacia in children. However, VB could be considered as an alternative diagnostic modality in children with symptoms suggestive of tracheobronchomalacia where FB is unavailable. Pediatr Pulmonol. 2017;52:480-486. © 2016 Wiley Periodicals, Inc.
CASE REPORT: Both procedures were conducted with advanced airway under total intravenous anaesthesia. 2.6 mm GS was used in combination with a 2.2 mm rEBUS probe, using a therapeutic bronchoscope. Case 1 describes a SPN in the apical segment of the right upper lobe that was inconclusive by forceps biopsy due to GS displacement and inadequate biopsy depth. A steerable GS combined with the novel cryoprobe subsequently overcame this issue. Case 2 describes a SPN in the apical segment of the left upper lobe in which the standard cryoprobe failed to advance through the GS due to steep angulation. It also highlights with shorter activation time, the novel cryoprobe enable biopsied tissue to be retrieved through the GS while the bronchoscope-GS remains wedgend in the airway segment. There were no bleeding or pneumothorax complications in both cases, and histopathological examination confirmed adenocarcinoma of the lung.
CONCLUSION: The 1.1 mm flexible cryoprobe in combination with GS and therapeutic bronchoscope offers an option to acquire adequate tissue in difficult-to-reach regions in the lung such as the apical segment of upper lobes. Further prospective series to evaluate its performance and safety in SPN biopsy is highly anticipated.