Displaying publications 1 - 20 of 474 in total

Abstract:
Sort:
  1. Ramanathan S, Lau WJ, Goh PS, Gopinath SCB, Rawindran H, Omar MF, et al.
    Mikrochim Acta, 2024 Sep 10;191(10):586.
    PMID: 39251454 DOI: 10.1007/s00604-024-06662-0
    A unique method for determining chlorophyll content in microalgae is devised employing a gold interdigitated electrode (G-IDE) with a 10-µm gap, augmented by a nano-molecularly imprinted polymer (nano-MIP) and a titanium dioxide/multiwalled carbon nanotube (TiO2/MWCNT) nanocomposite. The nano-MIP, produced using chlorophyll template voids, successfully trapped chlorophyll, while the TiO2/MWCNT nanocomposite, synthesized by the sol-gel technique, exhibited a consistent distribution and anatase crystalline structure. The rebinding of procured chlorophyll powder, which was used as a template for nano-MIP synthesis, was identified with a high determination coefficient (R2 = 0.9857). By combining the TiO2/MWCNT nanocomposite with nano-MIP, the G-IDE sensing method achieved a slightly better R2 value of 0.9892 for detecting chlorophyll in microalgae. The presented G-IDE sensor showed a significant threefold enhancement in chlorophyll detection compared with commercially available chlorophyll powder. It had a detection limit of 0.917 mL (v/v) and a linear range that spanned from 10-6 to 1 mL. The effectiveness of the sensor in detecting chlorophyll in microalgae was confirmed through validation of its repeatability and reusability.
    Matched MeSH terms: Electrodes*
  2. Mohd Nazree Derman, Mohd Nasuha Abd Halim, Shaiful Rizam Shamsudin
    MyJurnal
    The hardcoat anodising process was done by using different concentration of H2SO4 from 0% to 20%. The 90 volt of anodising process was applied by using Al foil as cathode materials. The surface changes on PM Al-Mg resulted by hardcoat anodising was characterised by XRD measured. Surface hardness was measured by Micro-Vickers hardness machine. The experiment found different XRD pattern between anodised PM Al-Mg samples. The study was found by that the optimum value for H2SO4 concentration was 15 % H2SO4 and result 26 μm thickness, 5.07% of mass changes and HVN 105.4 hardness. The hardcoat anodising was affected to the XRD pattern for PM Al-Mg.
    Matched MeSH terms: Electrodes
  3. Mulyadi IH, Fiedler P, Eichardt R, Haueisen J, Supriyanto E
    Med Biol Eng Comput, 2021 Feb;59(2):431-447.
    PMID: 33495984 DOI: 10.1007/s11517-021-02319-9
    Wearable electronics and sensors are increasingly popular for personal health monitoring, including smart shirts containing electrocardiography (ECG) electrodes. Optimal electrode performance requires careful selection of the electrode position. On top of the electrophysiological aspects, practical aspects must be considered due to the dynamic recording environment. We propose a new method to obtain optimal electrode placement by considering multiple dimensions. The electrophysiological aspects were represented by P-, R-, and T-peak of ECG waveform, while the shirt-skin gap, shirt movement, and regional sweat rate represented the practical aspects. This study employed a secondary data set and simulations for the electrophysiological and practical aspects, respectively. Typically, there is no ideal solution that maximizes satisfaction degrees of multiple electrophysiological and practical aspects simultaneously; a compromise is the most appropriate approach. Instead of combining both aspects-which are independent of each other-into a single-objective optimization, we used multi-objective optimization to obtain a Pareto set, which contains predominant solutions. These solutions may facilitate the decision-makers to decide the preferred electrode locations based on application-specific criteria. Our proposed approach may aid manufacturers in making decisions regarding the placement of electrodes within smart shirts.
    Matched MeSH terms: Electrodes
  4. Yasir SF, Jani J, Mukri M
    Data Brief, 2018 Dec;21:907-910.
    PMID: 30426044 DOI: 10.1016/j.dib.2018.10.057
    In the study, a relationship was establishment between electrical resistivity by using electrical resistivity imaging (ERI) technique with hydraulic conductivity. By using Schlumberger array configuration, 2D electrical resistivity image was produced by using ABEM SAS 4000 with eighty-one (81) electrodes (Loke, 2004) [1]. By using regression equation, hydraulic conductivity was calculated from electrical resistivity and this result was compared with the hydraulic conductivity obtained from pumping tests (Butler, 2005). This data suggested that electrical resistivity survey can be used as preliminary tool to assess any subsurface zone with non- invasive nondestructive for soil, reducing time and cost.
    Matched MeSH terms: Electrodes
  5. Amirah Ahmad, Mohamed Rozali Othman
    The electrooxidation of propionaldehyde and butyraldehyde on a gold electrode was studied by cyclic voltammetry in alkaline media. Electrooxidation of both aldehydes showed the appearance of two anodic peaks. Another oxidation peak on a newly generated electrode surface was observed after the corresponding reduction peak for both aldehydes.
    Matched MeSH terms: Electrodes
  6. Tay W, Yap S, Wong C
    Sains Malaysiana, 2014;43:583-594.
    The electrical characteristics of a filamentary dielectric barrier discharge (DBD) are studied experimentally and numerically. The DBD system which has parallel plate electrodes geometry is powered by a 50 Hz power supply and operated at atmospheric air. A dynamic electric circuit model considering the discharge region and the non-discharge region being connected by a surface resistance is proposed. Simulation using this model is shown to fit the experimentally measured QV diagram satisfactorily. The effects of the air gap distance and the dielectric surface on the discharge behavior are then investigated. It is found that the surface resistivity of the dielectric is one of the important parameters governing the discharge behavior.
    Matched MeSH terms: Electrodes
  7. Cheong JKK, Ooi EH, Ooi ET
    Int J Numer Method Biomed Eng, 2020 09;36(9):e3374.
    PMID: 32519516 DOI: 10.1002/cnm.3374
    Recent studies have demonstrated the effectiveness of switching bipolar radiofrequency ablation (bRFA) in treating liver cancer. Nevertheless, the clinical use of the treatment remains less common than conventional monopolar RFA - likely due to the lack of understanding of how the tissues respond thermally to the switching effect. The problem is exacerbated by the numerous possible switching combinations when bRFA is performed using bipolar needles, thus making theoretical deduction and experimental studies difficult. This article addresses this issue via computational modelling by examining if significant variation in the treatment outcome exists amongst six different electrode configurations defined by the X-, C-, U-, N-, Z- and O-models. Results indicated that the tissue thermal and thermal damage responses varied depending on the electrode configuration and the operating conditions (input voltage and ablation duration). For a spherical tumour, 30 mm in diameter, complete ablation could not be attained in all configurations with 70 V input voltage and 5 minutes ablation duration. Increasing the input voltage to 90 V enlarged the coagulation zone in the X-model only. With the other configurations, extending the ablation duration to 10 minutes was found to be the better at enlarging the coagulation zone.
    Matched MeSH terms: Electrodes
  8. Wang Y, Sun X, Gopinath SCB, Saheed MSM, Wang X
    Biotechnol Appl Biochem, 2022 Feb;69(1):376-382.
    PMID: 33538049 DOI: 10.1002/bab.2116
    Thyroid cancer appears in endocrine glands and specific to thyroid glands has been reported widely. This work was targeted to identify and quantify thyroglobulin by using antithyroglobulin antibody complexed silane surface on interdigitated electrode (IDE) sensing surface. (3-Aminopropyl)triethoxysilane linker was used to make silane-coupling with antibody and attached on the hydroxylated IDE. This electroanalytical IDE revealed the dose-dependent responses with thyroglobulin concentrations. By getting increments with the thyroglobulin concentrations, the current responses were enhanced concomitantly and the thyroglobulin detection limit was noted as 1 pM on the linear curve [y = 0.1311x + 0.5386; R² = 0.9707] with the sensitivity at lower picomolar range. Moreover, the control experiments with thyroid peroxidase and nonimmune antibody cannot yield any response of current, confirming the specific detection of thyroglobulin. This research set-up is useful to determine and quantify the thyroglobulin and diagnose thyroid cancer.
    Matched MeSH terms: Electrodes
  9. Lim SS, Fontmorin JM, Ikhmal Salehmin MN, Feng Y, Scott K, Yu EH
    Chemosphere, 2022 Feb;288(Pt 2):132548.
    PMID: 34653487 DOI: 10.1016/j.chemosphere.2021.132548
    A microbial electrolysis cell (MEC) fully catalysed by microorganisms is an attractive technology because it incorporates the state-of-the-art concept of converting organic waste to hydrogen with less external energy input than conventional electrolysers. In this work, the impact of the anode feed mode on the production of hydrogen by the biocathode was studied. In the first part, three feed modes and MEC performance in terms of hydrogen production were evaluated. The results showed the highest hydrogen production under the continuous mode (14.6 ± 0.4), followed by the fed-batch (12.7 ± 0.4) and batch (0 L m-2 cathode day-1) modes. On one hand, the continuous mode only increased by 15% even though the hydraulic retention time (HRT) (2.78 h) was lower than the fed-batch mode (HRT 5 h). A total replacement (fed-batch) rather than a constant mix of existing anolyte and fresh medium (continuous) was preferable. On the other hand, no hydrogen was produced in batch mode due to the extensive HRT (24 h) and bioanode starvation. In the second part, the fed-batch mode was further evaluated using a chronoamperometry method under a range of applied cell voltages of 0.3-1.6 V. Based on the potential evolution at the electrodes, three main regions were identified depending on the applied cell voltages: the cathode activation (<0.8 V), transition (0.8-1.1 V), and anode limitation (>1.1 V) regions. The maximum hydrogen production recorded was 12.1 ± 2.1 L m-2 cathode day-1 at 1.0 V applied voltage when the oxidation and reduction reactions at the anode and cathode were optimal (2.38 ± 0.61 A m-2). Microbial community analysis of the biocathode revealed that Alpha-, and Deltaproteobacteria were dominant in the samples with >70% abundance. At the genus level, Desulfovibrio sp. was the most abundant in the samples, showing that these microbes may be responsible for hydrogen evolution.
    Matched MeSH terms: Electrodes
  10. Yip WP, Kho ASK, Ooi EH, Ooi ET
    Med Eng Phys, 2023 Feb;112:103950.
    PMID: 36842773 DOI: 10.1016/j.medengphy.2023.103950
    No-touch bipolar radiofrequency ablation (bRFA) is known to produce incomplete tumour ablation with a 'butterfly-shaped' coagulation zone when the interelectrode distance exceeds a certain threshold. Although non-confluent coagulation zone can be avoided by not implementing the no-touch mode, doing so exposes the patient to the risk of tumour track seeding. The present study investigates if prior infusion of saline into the tissue can overcome the issues of non-confluent or butterfly-shaped coagulation. A computational modelling approach based on the finite element method was carried out. A two-compartment model comprising the tumour that is surrounded by healthy liver tissue was developed. Three cases were considered; i) saline infusion into the tumour centre; ii) one-sided saline infusion outside the tumour; and iii) two-sided saline infusion outside the tumour. For each case, three different saline volumes were considered, i.e. 6, 14 and 22 ml. Saline concentration was set to 15% w/v. Numerical results showed that saline infusion into the tumour centre can overcome the butterfly-shaped coagulation only if the infusion volume is sufficient. On the other hand, one-sided infusion outside the tumour did not overcome this. Two-sided infusion outside the tumour produced confluent coagulation zone with the largest volume. Results obtained from the present study suggest that saline infusion, when carried out correctly, can be used to effectively eradicate liver cancer. This presents a practical solution to address non-confluent coagulation zone typical of that during two-probe bRFA treatment.
    Matched MeSH terms: Electrodes
  11. Lam SM, Sin JC, Warren Tong MW, Zeng H, Li H, Huang L, et al.
    Chemosphere, 2023 Dec;344:140402.
    PMID: 37838031 DOI: 10.1016/j.chemosphere.2023.140402
    Environmental conservation and energy scarcity have become two core challenges with the ever-increasing advancement of industry, particularly chemical energy rich wastewater comprising refractory organics and pathogenic microbes. Here, a multifunctional photocatalytic fuel cell (PFC) was devised using NiFe2O4 nanoparticle-loaded on pine tree-like ZnO/Zn (NiFe2O4/ZnO/Zn) photoanode and CuO/Cu2O nanorods-loaded on Cu (CuO/Cu2O/Cu) cathode for extracting electricity upon wastewater treatment. When fed with Rhodamine B (RhB) dyestuff, the NiFe2O4/ZnO/Zn-PFC provided the maximum power density (Pmax) of 0.539 mW cm-2 upon visible light irradiation with an average RhB degradation of 85.2%, which were 2.8 and 2.7 times higher than ZnO/Zn, respectively. The remarkable enhanced NiFe2O4/ZnO/Zn-PFC performance was owing to the synergistic effect of pine tree-like structure and Z-scheme heterostructure. The pine tree-like with high surface area was not only for effective harnessing photon energies but also provided more directional routes for rapid segregation and transport of carriers and higher interface contacting areas with electrolyte. Through a series of systematic characterizations, the Z-scheme heterostructure mechanism of the system and organics degradation pathway were also speculated. Additionally, the performance of the NiFe2O4/ZnO/Zn-PFC in industry printing wastewater showed Pmax of 0.600 mW cm-2, which was considerably impressive as real wastewater was challenging to accomplish. The phytotoxicity outcome also manifested that the comprehensive toxicity of RhB was eradicated after PFC treatment. Lastly, the excellent recyclability and the pronounced bactericidal effect towards Escherichia coli and Staphylococcus aureus were other attributions which enabled the NiFe2O4/ZnO/Zn-PFC for possible practical application.
    Matched MeSH terms: Electrodes
  12. Manoj D, Rajendran S, Murphy M, Jalil AA, Sonne C
    Chemosphere, 2023 Nov;340:139820.
    PMID: 37586499 DOI: 10.1016/j.chemosphere.2023.139820
    Over the past decades, increasing research in metal-organic frameworks (MOFs) being a large family of highly tunable porous materials with intrinsic physical properties, show propitious results for a wide range of applications in adsorption, separation, electrocatalysis, and electrochemical sensors. MOFs have received substantial attention in electrochemical sensors owing to their large surface area, active metal sites, high chemical and thermal stability, and tunable structure with adjustable pore diameters. Benefiting from the superior properties, MOFs and MOF-derived carbon materials act as promising electrode material for the detection of food contaminants. Although several reviews have been reported based on MOF and its nanocomposites for the detection of food contaminants using various analytical methods such as spectrometric, chromatographic, and capillary electrophoresis. But there no significant review has been devoted to MOF/and its derived carbon-based electrodes using electrochemical detection of food contaminants. Here we review and classify MOF-based electrodes over the period between 2017 and 2022, concerning synthetic procedures, electrode fabrication process, and the possible mechanism for detection of the food contaminants which include: heavy metals, antibiotics, mycotoxins, and pesticide residues. The merits and demerits of MOF as electrode material and the need for the fabrication of MOF and its composites/derivatives for the determination of food contaminants are discussed in detail. At last, the current opportunities, key challenges, and prospects in MOF for the development of smart sensing devices for future research in this field are envisioned.
    Matched MeSH terms: Electrodes
  13. Jesudason CG
    Int J Mol Sci, 2009 May;10(5):2203-51.
    PMID: 19564949 DOI: 10.3390/ijms10052203
    This review is variously a presentation, reflection, synthesis and report with reference to more recent developments of an article - in a journal which has ceased publication - entitled "Some Electrode Theorems with Experimental Corroboration, Inclusive of the Ag/AgCl System" Internet Journal of Chemistry, (http://www.ijc.com), Special Issues: Vol. 2 Article 24 (1999). The results from new lemmas relating charge densities and capacitance in a metallic electrode in equilibrium with an ionic solution are used to explain the data and observed effects due to Esin, Markov, Grahame, Lang and Kohn. Size effects that vary the measured e.m.f. of electrodes due to changes in the electronic chemical potential are demonstrated in experiment and theory implying the need for standardization of electrodes with respect to geometry and size. The widely used Stern modification of the Gouy-Chapman theory is shown to be mostly inapplicable for many of the problems where it is employed. Practical consequences of the current development include the possibility of determining the elusive single-ion activity coefficients of solution ions directly from the expression given by a simplified capacitance theorem, the potential of zero charge and the determination of single ion concentrations of active species in the electrode reactions from cell e.m.f. measurements.
    Matched MeSH terms: Electrodes*
  14. Kamali KZ, Alagarsamy P, Huang NM, Ong BH, Lim HN
    ScientificWorldJournal, 2014;2014:396135.
    PMID: 25136664 DOI: 10.1155/2014/396135
    Hematite (α-Fe2O3) nanoparticles were synthesized by the solid transformation of ferrous hydroxide and ferrihydrite in hydrothermal condition. The as-prepared α-Fe2O3 nanoparticles were characterized by UV-vis, PL, XRD, Raman, TEM, AFM, FESEM, and EDX analysis. The experimental results indicated the formation of uniform hematite nanoparticles with an average size of 45 nm and perfect crystallinity. The electrochemical behavior of a GC/α-Fe2O3 electrode was studied using CV and EIS techniques with an electrochemical probe, [Fe(CN)6](3-/4-) redox couple. The electrocatalytic activity was investigated toward DA oxidation in a phosphate buffer solution (pH 6.8) by varying different experimental parameters. The chronoamperometric study showed a linear response in the range of 0-2 μM with LoD of 1.6 μM for DA. Square wave voltammetry showed a linear response in the range of 0-35 μM with LoD of 236 nM for DA.
    Matched MeSH terms: Electrodes*
  15. Slaninova N, Fiedorova K, Selamat A, Danisova K, Kubicek J, Tkacz E, et al.
    Sensors (Basel), 2020 Jun 30;20(13).
    PMID: 32629993 DOI: 10.3390/s20133666
    The subject of the submitted work is the proposal of electrodes for the continual measurement of the glucose concentration for the purpose of specifying further hemodynamic parameters. The proposal includes the design of the electronic measuring system, the construction of the electrodes themselves and the functionality of the entire system, verified experimentally using various electrode materials. The proposed circuit works on the basis of micro-ammeter measuring the size of the flowing electric current and the electrochemical measurement method is used for specifying the glucose concentration. The electrode system is comprised of two electrodes embedded in a silicon tube. The solution consists of the measurement with three types of materials, which are verified by using three solutions with a precisely given concentration of glucose in the form of a mixed solution and enzyme glucose oxidase. For the testing of the proposed circuit and the selection of a suitable material, the testing did not take place on measurements in whole blood. For the construction of the electrodes, the three most frequently used materials for the construction of electrodes used in clinical practice for sensing biopotentials, specifically the materials Ag/AgCl, Cu and Au, were used. The performed experiments showed that the material Ag/AgCl, which had the greatest sensitivity for the measurement even without the enzyme, was the most suitable material for the electrode. This conclusion is supported by the performed statistical analysis. On the basis of the testing, we can come to the conclusion that even if the Ag/AgCl electrode appears to be the most suitable, showing high stability, gold-plated electrodes showed stability throughout the measurement similarly to Ag/AgCl electrodes, but did not achieve the same qualities in sensitivity and readability of the measured results.
    Matched MeSH terms: Electrodes*
  16. Zubair M, Tang TB
    Sensors (Basel), 2014;14(7):11351-61.
    PMID: 24967606 DOI: 10.3390/s140711351
    This paper presents the design of a non-intrusive system to measure ultra-low water content in crude oil. The system is based on a capacitance to phase angle conversion method. Water content is measured with a capacitance sensor comprising two semi-cylindrical electrodes mounted on the outer side of a glass tube. The presence of water induces a capacitance change that in turn converts into a phase angle, with respect to a main oscillator. A differential sensing technique is adopted not only to ensure high immunity against temperature variation and background noise, but also to eliminate phase jitter and amplitude variation of the main oscillator that could destabilize the output. The complete capacitive sensing system was implemented in hardware and experiment results using crude oil samples demonstrated that a resolution of ± 50 ppm of water content in crude oil was achieved by the proposed design.
    Matched MeSH terms: Electrodes
  17. Al-Hardan NH, Abdul Hamid MA, Ahmed NM, Jalar A, Shamsudin R, Othman NK, et al.
    Sensors (Basel), 2016 Jun 07;16(6).
    PMID: 27338381 DOI: 10.3390/s16060839
    In this study, porous silicon (PSi) was prepared and tested as an extended gate field-effect transistor (EGFET) for pH sensing. The prepared PSi has pore sizes in the range of 500 to 750 nm with a depth of approximately 42 µm. The results of testing PSi for hydrogen ion sensing in different pH buffer solutions reveal that the PSi has a sensitivity value of 66 mV/pH that is considered a super Nernstian value. The sensor considers stability to be in the pH range of 2 to 12. The hysteresis values of the prepared PSi sensor were approximately 8.2 and 10.5 mV in the low and high pH loop, respectively. The result of this study reveals a promising application of PSi in the field for detecting hydrogen ions in different solutions.
    Matched MeSH terms: Electrodes
  18. Md Razak Daud, Wan Nor Shela Ezwane Wan Jusoh, Syahrullail Samion
    MyJurnal
    This study investigates metal removal rate (MRR) of the biomaterial by using discharge machine Neuar CNC A50 Electrical Discharge Machine Die Sinking (EDM DS). The purpose of this study is to compare machining curvature cup for material SKD 11 and stainless steel with shape curvature cup acetabular. The result showed that electrode wear is higher when high current is applied. For each applied current 0.5A and 3.0A could result electrode wear of 0.236 mm, 0.246 mm and 0.269 mm respectively. Mean time of complete discharged for each pit with 0.3mm depth with supply 0. 5A is 6.51 minutes; 1. 5A is 3.54 minutes and 3A is 1.52 minutes. The biggest mean parameter of the pit is 0.356 mm, with 3A of current is applied. From this study, it can be concluded that low current set may give lower electrode copper wear. The experiment will help a researcher to discharge biomaterial types of metal with small size of copper electrode use of EDM DS Neuar for discharge multi hole or micro pit.
    Matched MeSH terms: Electrodes
  19. Yang J, Mohmad AR, Wang Y, Fullon R, Song X, Zhao F, et al.
    Nat Mater, 2019 12;18(12):1309-1314.
    PMID: 31451781 DOI: 10.1038/s41563-019-0463-8
    Metallic transition metal dichalcogenides (TMDs)1-8 are good catalysts for the hydrogen evolution reaction (HER). The overpotential and Tafel slope values of metallic phases and edges9 of two-dimensional (2D) TMDs approach those of Pt. However, the overall current density of 2D TMD catalysts remains orders of magnitude lower (~10-100 mA cm-2) than industrial Pt and Ir electrolysers (>1,000 mA cm-2)10,11. Here, we report the synthesis of the metallic 2H phase of niobium disulfide with additional niobium (2H Nb1+xS2, where x is ~0.35)12 as a HER catalyst with current densities of >5,000 mA cm-2 at ~420 mV versus a reversible hydrogen electrode. We find the exchange current density at 0 V for 2H Nb1.35S2 to be ~0.8 mA cm-2, corresponding to a turnover frequency of ~0.2 s-1. We demonstrate an electrolyser based on a 2H Nb1+xS2 cathode that can generate current densities of 1,000 mA cm-2. Our theoretical results reveal that 2H Nb1+xS2 with Nb-terminated surface has free energy for hydrogen adsorption that is close to thermoneutral, facilitating HER. Therefore, 2H Nb1+xS2 could be a viable catalyst for practical electrolysers.
    Matched MeSH terms: Electrodes
  20. Nagai K, Kuwabara T, Ahmad MF, Nakano M, Karakawa M, Taima T, et al.
    Chem Commun (Camb), 2019 Oct 15;55(83):12491-12494.
    PMID: 31573004 DOI: 10.1039/c9cc04759j
    Photoelectrochemical oxidation of thiols was enhanced with a threshold potential of -0.35 V vs. Ag/AgCl by the use of a ZnPc/PCBM:P3HT/ZnO electode, which was prepared by removing the PEDOT:PSS/Au electrode of an inverted OPV device and coating it with ZnPc. A co-photocatalysis property of ZnPc was observed in the photoelectrochemistry and scanning Kelvin probe microscopy.
    Matched MeSH terms: Electrodes
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links