Displaying publications 1 - 20 of 29 in total

Abstract:
Sort:
  1. Md Muziman Syah, Khairidzan Mohd Kamal, Mahfuzah Mokhtar, Aminul Hakim Sofian Sauri
    MyJurnal
    Corneal power or keratometric value represents two-third of total
    refractive power of the eye. It is an important parameter in intraocular lens calculation.
    Purpose of the study was to evaluate repeatability and agreement of keratometric
    measurements obtained from a six points-based keratometry device; IOLMaster 500 (Carl
    Zeiss Meditec AG, Jena, Germany) and two Placido disc-based keratometry devices;
    Atlas Topographer 995 and 9000 models (Carl Zeiss Meditec AG, Jena, Germany). (Copied from article).
    Matched MeSH terms: Lenses, Intraocular
  2. Sukumaran K
    Med J Malaysia, 1983 Dec;38(4):272-4.
    PMID: 6599981
    Matched MeSH terms: Lenses, Intraocular*
  3. Lim TK
    Med J Malaysia, 1984 Sep;39(3):205-9.
    PMID: 6544921
    50 cases of anterior chamber intraocular lens implantation at the University Hospital, Kuala Lumpur were studied. 80% of the cases achieved visual acuity of 6/9 or better. The percentage would be higher if cases with pre-existing pathology are excluded and the period of follow-up is longer. Complications, mainly minor and non sight-threatening, are discussed.
    Matched MeSH terms: Lenses, Intraocular*
  4. Wern-Yih C, Jan-Bond C, Sudha M, Norlelawati A, Shatriah I
    Arq Bras Oftalmol, 2020 08;83(4):329-331.
    PMID: 32756777 DOI: 10.5935/0004-2749.20200054
    Despite the recent developments in modern cataract surgery and the application of a vast array of new devices and machines, late in-the-bag intraocular lens dislocation remains a devastating, albeit rare, complication. Various nonsurgical and surgical techniques have been used to manage this complication. We report a case of spontaneous repositioning in the left eye of an anteriorly subluxated in-the-bag intraocular lens. The spontaneous repositioning may have been caused by antagonistic effects related to the topical administration of brimonidine and prednisolone. The dislocation was treated without aggressive manipulation or surgical intervention.
    Matched MeSH terms: Lenses, Intraocular*
  5. Thevi T, Abas AL
    Kathmandu Univ Med J (KUMJ), 2021 2 18;18(70):122-132.
    PMID: 33594017
    Background Cataract surgery which is the only scientific method to treat cataracts has evolved from large incisions of intracapsular cataract excision to extracapsular cataract exicison and now modern day phacoemulsification. Anaesthesia too has progressed from general anaesthesia to local and topical anaesthesia. A variety of intraocular lenses are available ranging from rigid to foldable, multifocal and toric. Day care surgeries are becoming the norm these days. Objective Cataract surgery has advanced with new techniques and modalities. We studied the trends of cataract surgery and outcomes over the years. Method We performed secondary data analysis (National Eye Database) of cataract surgery patients in Hospital Melaka (2007 - 2014). Result Most patients were 60-69 years (mean 65.0 years). Primary cataract rose (p<0.05) but there was no difference in laterality and first or second eye (p>0.05). More patients presented with Hypertension and Diabetes (p<0.05). Pterygium encroaching the cornea showed a rise (p<0.05). Phacoemulsification (80.8%) showed a rise while Extracapsular Cataract Extraction (ECCE) (15.4%) declined (p<0.05). More Specialists operated and fewer combined surgeries were performed (p<0.001). Type of anaesthesia did not change (p>0.05). Operative complications reduced (p<0.001). Anterior chamber, scleral fixated and foldable intraocular lenses usage reduced (p<0.05). There was no change in pre-operative visual acuity (p>0.05) but postoperative vision showed a rise in good outcomes (p<0.05). Conclusion Melaka Hospital shows a rise in phacoemulsification and a decline in Extracapsular Cataract Extraction. More patients presented with primary cataracts. More Specialists operated and there was a reduction in intraoperative and postoperative complications. Post-operative visual outcomes showed a remarkable improvement. This improvement is in keeping with the aim of improved vision for all by 2020.
    Matched MeSH terms: Lenses, Intraocular*
  6. Jaais F
    Med J Malaysia, 1998 Sep;53(3):272-6.
    PMID: 10968165
    Secondary intraocular lens implantation after cataract surgery done in University Hospital between 1983 to 1993 were reviewed. Thirty three patients (37 eyes) underwent secondary intraocular lens implantation during this period. Twenty four eyes had secondary anterior chamber lens implantation while 13 had posterior chamber lens implantation. There was no case of secondary posterior scleral fixation lens implantation. Visual acuity of 6/9 or better was seen in 25 of 37 eyes (67%) in the series. Eyes seeing as good or better than before secondary implantation procedure were noted in 34 of 37 eyes (92%). Vision of 6/9 or better was seen in 9 of 13 eyes (70%) with posterior chamber implants and 16 of 24 eyes in (67%) with anterior chamber lenses. Complications including bullous keratopathy, uveitis and glaucoma were seen with anterior chamber implants of the rigid type resulting in poorer visual acuity than before the secondary procedure.
    Matched MeSH terms: Lenses, Intraocular*
  7. Bastion ML
    BMJ Case Rep, 2010;2010.
    PMID: 22242074 DOI: 10.1136/bcr.10.2009.2398
    The use of 0.5 mg/0.05 ml of ranibizumab intracamerally, to induce regression of iris neovascularisation in a non-diabetic patient, is reported. A 55-year-old Malay man presented with left eye rubeosis and hyphaema secondary to ischaemic remnant retinal flap in his silicone filled pseudophakic eye. Regression of rubeosis and resolution of hyphaema was noted within 4 days of injection of intracameral ranibizumab, allowing repeat vitrectomy to be performed without much bleeding, thus facilitating removal of his intraocular lens and laser to remaining flap. One month postoperatively he remained comfortable with counting fingers vision similar to the pre-hyphaema period.
    Matched MeSH terms: Lenses, Intraocular
  8. Kuan BB, Lim TK
    Med J Malaysia, 1984 Dec;39(4):280-4.
    PMID: 6544933
    Ultrasound measurement of ocular dimension is the chosen method for assessing axial length when determining dioptric power for intraocular lens. From the current results of 30 cases studied, the mean axial length ranges from 22 to 23 mm. Despite the limitation of the accuracy of the ultrasonic measurements with the 7.5 mHz transducer, the power of intraocular lens can. be determined satisfactorily in accordance with the knowledge of keratometric reading. Hence, high refractive errors could be avoided post-operatively.
    Matched MeSH terms: Lenses, Intraocular
  9. Naicker P, Sundralingam S, Peyman M, Juana A, Mohamad NF, Win MM, et al.
    Int Ophthalmol, 2015 Aug;35(4):459-66.
    PMID: 25024102 DOI: 10.1007/s10792-014-9970-4
    To determine the accuracy of intraocular lens (IOL) calculations in eyes undergoing phacoemulsification cataract surgery with IOL implantation using immersion A-scan ultrasound (US) and Lenstar LS 900(®) biometry. In this prospective study, 200 eyes of 200 patients were randomized to undergo either Lenstar LS 900(®) or immersion A-scan US biometry to determine the IOL dioptric power prior to phacoemulsification cataract surgery. Post-operative refractive outcomes of these two groups of patients were compared. The result showed no significant difference between the target spherical equivalent (SE) and the post-operative SE value by the Lenstar LS 900(®) (p value = 0.632) or immersion A-scan US biometry (p value = 0.438) devices. The magnitude of difference between the two biometric devices were not significantly different (p value = 0.868). There was no significant difference in the predicted post-operative refractive outcome between immersion A-scan US biometry and Lenstar LS 900(®). Based on the results, the immersion A-scan US technique is as accurate as Lenstar LS 900(®) in the hands of an experienced operator.
    Matched MeSH terms: Lenses, Intraocular*
  10. Jasman AA, Shaharuddin B, Noor RA, Ismail S, Ghani ZA, Embong Z
    BMC Ophthalmol, 2010;10:20.
    PMID: 20738840 DOI: 10.1186/1471-2415-10-20
    Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month post cataract surgery with primary implantation of an intraocular lens using SRK II versus Pediatric IOL Calculator for pediatric intraocular lens calculation. Pediatric IOL Calculator is a modification of SRK II using Holladay algorithm. This program attempts to predict the refraction of a pseudophakic child as he grows, using a Holladay algorithm model. This model is based on refraction measurements of pediatric aphakic eyes. Pediatric IOL Calculator uses computer software for intraocular lens calculation.
    Matched MeSH terms: Lenses, Intraocular/standards*
  11. Poh EP, Fariza NN, Mariam I
    Med J Malaysia, 2005 Aug;60(3):370-2.
    PMID: 16379196
    A 61-year-old Chinese man presented with bilateral posteriorly dislocated anterior chamber intraocular lenses (AC IOLs) one year after successful vitrectomy, removal of bilateral dislocated mature cataractous lenses and AC IOLs implantation. A thorough clinical evaluation revealed habitual eye rubbing as the only possible cause.
    Matched MeSH terms: Lenses, Intraocular/adverse effects*
  12. Lim AS, Ang BC, Heng LK, Hart PM, Ngui MS, Chew P, et al.
    Ann Acad Med Singap, 1989 Mar;18(2):174-7.
    PMID: 2751233
    This is a retrospective study of 525 posterior chamber implants in diabetics performed by A S M Lim and B C Ang of Singapore. The patients were reviewed by visiting ophthalmologists--J E Kennedy (Sydney), M Ngui (East Malaysia) and P M Hart (Belfast). This study did not show any significant difference in the complication of post-operative visual acuity between diabetics and non-diabetics. 95% obtained 6/12 vision or better when pre-existing disease was excluded. It also showed that posterior chamber implants can be inserted in eyes with maculopathy or proliferative retinopathy if laser treatment was effectively done before or after surgery.
    Matched MeSH terms: Lenses, Intraocular*
  13. Singh M, Dahalan A
    Br J Ophthalmol, 1987 Nov;71(11):850-3.
    PMID: 3689737
    A total of 94 patients underwent extracapsular cataract extraction and insertion of Sinsky style two-loop posterior chamber intraocular lenses. Forty-six eyes received a standard power IOL and 48 eyes were given a preoperatively calculated IOL. A significant difference was found in the two groups with regard to the postoperative refractive error and uncorrected visual acuity.
    Matched MeSH terms: Lenses, Intraocular*
  14. Lam CK, Sundaraj K, Sulaiman MN
    Medicina (Kaunas), 2013;49(1):1-8.
    PMID: 23652710
    The aim of this study was to review the capability of virtual reality simulators in the application of phacoemulsification cataract surgery training. Our review included the scientific publications on cataract surgery simulators that had been developed by different groups of researchers along with commercialized surgical training products, such as EYESI® and PhacoVision®. The review covers the simulation of the main cataract surgery procedures, i.e., corneal incision, capsulorrhexis, phacosculpting, and intraocular lens implantation in various virtual reality surgery simulators. Haptics realism and visual realism of the procedures are the main elements in imitating the actual surgical environment. The involvement of ophthalmology in research on virtual reality since the early 1990s has made a great impact on the development of surgical simulators. Most of the latest cataract surgery training systems are able to offer high fidelity in visual feedback and haptics feedback, but visual realism, such as the rotational movements of an eyeball with response to the force applied by surgical instruments, is still lacking in some of them. The assessment of the surgical tasks carried out on the simulators showed a significant difference in the performance before and after the training.
    Matched MeSH terms: Lenses, Intraocular
  15. Aziz S, Asokumaran T, Intan G
    Med J Malaysia, 2011 Mar;66(1):64-5.
    PMID: 23765148 MyJurnal
    Blunt ocular trauma may result in expulsion of the intraocular lens in a patient who has undergone cataract surgery. This case report describes a patient who presented with an extrusion of intraocular lens following blunt ocular trauma post-operatively. The authors emphasise the importance of patient counselling and protection of the operated eye after surgery.
    Matched MeSH terms: Lenses, Intraocular
  16. Thanigasalam T, Reddy SC, Zaki RA
    J Ophthalmic Vis Res, 2016 4 7;10(4):375-84.
    PMID: 27051481 DOI: 10.4103/2008-322X.158892
    PURPOSE: Cataract surgery is the most common intraocular surgery performed all over the world and has advanced technically in recent years. As in all surgeries, complications are unavoidable. Herein we report factors associated with complications and visual outcomes of cataract surgery.

    METHODS: This retrospective cohort study included data of 1,632 cataract surgeries performed from 2007 to 2010 which was obtained from the cataract registry of the Malaysian National Eye Database. Demographic features, ocular and systemic comorbidites, grade of surgeon expertise and duration of surgery, type of anesthesia, intraoperative and postoperative complications, and the type of intraocular lens were recorded. Best corrected visual acuities were compared before and after the operation.

    RESULTS: Mean patient age was 66.9 years with equal gender distribution. The majority of subjects had age related cataracts. Phacoemulsification was done faster than other surgeries, especially by specialist surgeons. History of prior ocular surgery and operations performed under general anesthesia were associated with greater complications. Phacoemulsification was associated with less complications and better visual outcomes. The age and etiology of cataract did not affect complications. Malays, absence of ocular comorbidities, left eyes and eyes operated under local anesthesia were more likely to experience more visual improvement. Gender, age, cause of cataract, systemic comorbidities and surgeon expertise as well as intra-and postoperative complications did not affect the visual outcomes.

    CONCLUSION: Phacoemulsification had good visual outcomes in cataract surgery. Duration of surgery, expertise of the surgeon and complications did not affect the visual outcomes.

    Matched MeSH terms: Lenses, Intraocular
  17. Royan, Jeyarine, Teo, Khairy Shamel Sonny, Vengadasalam, Selva Raja
    MyJurnal
    To report on a rare case of an intralenticular foreign body which
    demonstrates that use of a spring-powered airsoft gun can result in a severe
    ocular injury. A 2-year-old male presented following a trauma to the left eye.
    The trauma was caused by a wooden matchstick from a spring-powered airsoft
    gun being shot into his eye. On examination, there was a shallow anterior
    chamber with a full thickness corneal laceration, with fragmented matchstick
    pieces embedded in the cornea and in the lens. The corneal foreign bodies
    were removed, corneal laceration wound sutured and lensectomy done. There
    were no post-operative complications, and the cornea wound healed with a
    scar. A few months later, he underwent a successful secondary intraocular lens
    implantation surgery with an iris claw lens. Airsoft guns are easily available to
    children who are unaware of its dangers. It can cause significant ocular
    morbidity despite successful surgical treatment of the injury.
    Matched MeSH terms: Lenses, Intraocular
  18. Azhany Y, Hemalatha C, Nani D, Rosediani M, Liza-Sharmini A
    Malays Fam Physician, 2013;8(1):33-7.
    PMID: 25606266 MyJurnal
    Cataract is the most common cause of blindness in the world. An attack of phacolytic and phacomorphic glaucoma as a result of neglected cataract constitutes a medical emergency that must be addressed immediately. Ocular emergencies such as these is challenging for the surgeon with guarded or poor prognosis. We describe the presentation, management and prognosis of three cases of phacomorphic and phacolytic glaucoma. All three patients underwent aggressive management of intraocular pressure. Despite successful cataract operation with implantation of intraocular lens, there was only mild improvement of the vision. Optic nerve and pupil functions were permanently affected following the insult. Phacomorphic and phacolytic glaucoma present a very challenging problem to the surgeon with poor visual outcome. Public health education and awareness are important and health workers should encourage patients with cataract to seek early treatment for better prognosis.
    Matched MeSH terms: Lenses, Intraocular
  19. Lam, C.S., Mushawiahti, M., Bastion, M.L.C.
    MyJurnal
    Subluxation or dislocation of PCIOL is one of the complications of cataract operation in RP patients. This paper reports the presentation of PCIOL dislocation and subluxation and the management and outcome in 3 eyes of 2 RP patients. Two medical records of patients with RP who developed dislocated or subluxated PCIOL and subsequently underwent explantation of the dropped IOL were evaluated. Two patients had bilateral eye cataract operation done and had PCIOL implanted. Patient 1 developed left eye subluxated PCIOL inferiorly after 2 years of the cataract operation and right eye dislocated PCIOL anteriorly 4 years after cataract operation. Patient 2 develop right eye subluxated PCIOL inferiorly after 12 years of the cataract operation. Patient 1 with right eye dislocated PCIOL underwent intraocular lens (IOL) explantation and was left aphakic as her visual prognosis was poor due to advanced RP. The left IOL remained within the visual axis despite subluxation and no intervention has been done. Patient 2 with right eye subluxated PCIOL underwent IOL explantation and anterior chamber intraocular lens (ACIOL) implantation. ACIOL remained stable and visual acuity improved post-operation. Both the operations were uneventful. Post-operatively, there was no elevated intraocular pressure and no prolonged ocular inflammation, which required prolonged anti-inflammatory and no retinal detachment was seen. Both patient and surgeon should be aware of potential PCIOL subluxation or dislocation in RP. The presentation may be as late as more than a decade after the cataract operation.
    Matched MeSH terms: Lenses, Intraocular
  20. Lim AK, Goh PP, Azura R, Mariam I
    J Cataract Refract Surg, 2011 Apr;37(4):655-9.
    PMID: 21420589 DOI: 10.1016/j.jcrs.2010.10.050
    PURPOSE: To determine the prevalence of and risk factors for AcriFlex 50CSE hydrophilic acrylic intraocular lens (IOL) opacification approximately 3 years after implantation.
    SETTING: Selayang Hospital, Selangor, Malaysia.
    DESIGN: Cross-sectional study.
    METHODS: Patients who had AcriFlex 50CSE IOL implantation in 2005 and 2006 were identified from operating logbooks and recalled via telephone and letters. Opaque IOLs were explanted and sent for scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS).
    RESULTS: The review showed that 18 patients had died and 67 had declined examination or could not be contacted, leaving 239 eyes for evaluation. The age of the patients ranged from 25 to 85 years. Of the patients, 83 (34.7%) were Malay, 127 (53.1%) Chinese, and 29 (12.1%) East Indian. The male:female ratio was 1:1. Fourteen eyes of 13 patients (5.4%) had IOL opacification; 1 had bilateral opacification. Five eyes had fine deposits, and 9 eyes had dense opaque deposits. Seven opaque IOLs required explantation. There was no correlation between age (P=.645), sex (P=.319), or race (P=.860) and IOL opacification. Pearson chi-square analysis showed a strong association between diabetes mellitus and IOL opacification (P=.019). Nine (69.2%) of the 13 patients with opacification had diabetes. Scanning electron microscopy and EDS showed calcium and phosphate deposits on the optic surface and intralenticularly near the anterior surface of the optic.
    CONCLUSIONS: Results indicate that diabetes mellitus is a risk factor for AcriFlex hydrophilic acrylic IOL opacification. In some cases, opacification affected vision, necessitating explantation. The pathophysiology of this complication is unknown.
    FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
    Matched MeSH terms: Lenses, Intraocular*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)