METHODS: An online questionnaire was sent out in April 2021, to Malaysian Ophthalmologists and medical officers who perform cataract surgeries. The questions were focused on the preferred cataract surgery practices of the participants. All data obtained were collected, tabulated and analysed.
RESULTS: A total of 173 participants responded to the online questionnaire. 55% of the participants were within 31-40 years of age. 56.1% preferred peristaltic pump over venturi system. 91.3% of participants practised povidone iodine instillation to the conjunctival sac. With regards to the main wound incision, more than half of the surgeons (50.3%) preferred fixed superior incision and 72.3% of them preferred 2.75 mm microkeratome blade. Most of the participants (63%) were inclined towards C-Loop clear intraocular lens (IOL) with a single-handed push preloaded system. 78.6% of the surgeons routinely use carbachol in their cataract surgery.
CONCLUSIONS: This survey provides some insight into the current practices among Malaysian ophthalmologists. Most of the practices are in line with international guidelines for preventing postoperative endophthalmitis. This article could help trainees and ophthalmologists benchmark and observe the common cataract surgery practices among their seniors and peers in Malaysia.
AIM: The examinations aim to calculate the intraocular lens (IOL) power required to achieve emmetropia following cataract surgery.
METHODS: Five Bornean sun bears diagnosed with cataracts at the Bornean Sun Bear Conservation Centre in Malaysia underwent ocular examination under general anesthesia. Keratometry and biometry data, including anterior chamber depth, crystalline lens thickness, and axial globe length, were collected using an automated keratometer and B-mode ultrasound. The Retzlaff, Binkhorst, Colenbrander, and Fyodorov formulas were used to estimate the required IOL power.
RESULTS: The mean corneal keratometric power was 56.94 D, the mean axial globe length was 12.93 mm, and the mean calculated postoperative anterior chamber depth was 4.77 mm. The mean calculated IOL power was +92.96 D. Conclusion: Aphakic cataract surgery were decided following these findings showing no available commercial IOL implants for this species. These findings provide valuable baseline data for optimizing cataract surgery in Bornean sun bears.
METHODS: Patient demography, pre-operative visual acuity, intra-operative complications, post-operative complications and post-operative visual acuity were recorded for two hundred and forty seven of the 400 patients who underwent cataract surgery during a 2-week period. The cost of surgery, which included capital, staff and overhead, and patient care consumable costs were assessed prospectively in 8 randomly sampled patients over a 3-month period. Cost efficiency refers to cost per cataract surgery. Cost effectiveness refers to cost per successful cataract surgery. This is estimated by the ratio of cost efficiency to the proportion of successful cataract surgery. Successful surgery was defined as best-corrected visual acuity (BCVA) of better than 6/12 at 3 months post-operatively.
RESULTS: Proportion of patients who had post-operative visual acuity of 6/12 or better was higher in phacoemulsification group (94%) than in the ECCE group (81%). Conventional extracapsular cataract surgery with intraocular lens implant costs RM3442 (USD 905.79) and phacoemulsification with intraocular lens implant costs RM4288 (USD 1128.42).
DISCUSSION: There was no significant difference in cost effectiveness between ECCE and phacoemulsification. The cost of cataract surgery in the MOH hospital was found to be high due to the high overhead costs.