METHOD: This interventional cohort pilot study on patients with Eustachian tube dysfunction compared those with nasopharyngeal carcinoma to patients without. Outcome assessment was based on tympanometry type and Eustachian Tube Dysfunction Questionnaire score.
RESULTS: A total of 14 ears (12 patients) were tested. Only 14 per cent of the nasopharyngeal carcinoma cohort showed improvement, while 71 per cent of the non-nasopharyngeal carcinoma group were successfully treated. No significant adverse effect was reported in any patient during this study.
CONCLUSION: Balloon Eustachian tube dilatation was not shown to be beneficial for post-radiotherapy Eustachian tube dysfunction in nasopharyngeal carcinoma patients in the preliminary stages of this pilot study.
METHOD: Forty-six Malay adults (aged 23-74 years) with tinnitus were enrolled. They were instructed to fill in the BEST questionnaire accordingly. After one week, 21 of them were asked to fill in the questionnaire again. The other 25 subjects underwent tinnitus intervention for three months and following this; the BEST was administered to them again.
RESULTS: In the test-retest reliability task, the intraclass correlation values obtained were acceptably high (0.70-0.90). After the intervention, significant differences in the BEST result were found in the mind domain, main domain and composite score (p<0.05) with moderate effect sizes (0.61- 0.70).
CONCLUSION: The test-retest reliability of the BEST was found to be good. It also showed good responsiveness to intervention. The clinical usefulness of the BEST in assessing patients with tinnitus was further supported by the present study.
Method: Participants of this cross-sectional study included 99 full-term neonates (165 ears) with mean chronological age of 46.7 hrs (SD = 26.3 hrs). Of the 99 neonates, 58 were Malay, 28 were Indian, and 13 were Chinese. The neonates who passed high-frequency (1 kHz) tympanometry, acoustic stapedial reflex, and distortion product otoacoustic emission screening tests were assessed using a pressurized WBA test (wideband tympanometry). To reduce the number of measurement points, the WBA responses were averaged to 16 one-third octave frequency bands from 0.25 to 8 kHz. A mixed-model analysis of variance was applied to the data to investigate the effects of frequency, ear, gender, and ethnicity on WBA. The analysis of variance was also used to compare between WBA measured at TPP and 0 daPa. An interclass correlation coefficient test was applied at each of the 16 frequency bands to measure the test-retest reliability of WBA at TPP and 0 daPa.
Results: Both WBA measurements at TPP and 0 daPa exhibited a multipeaked pattern with 2 maxima at 1.25-1.6 kHz and 6.3 kHz and 2 minima at 0.5 and 4 kHz. The mean WBA measured at TPP was significantly higher than that measured at 0 daPa at 0.25, 0.4, 0.5, 1.25, and 1.6 kHz only. A normative data set was developed for absorbance at TPP and at 0 daPa. There was no significant effect of ethnicity, gender, and ear on both measurements of WBA. The test-retest reliability of WBA at TPP and 0 daPa was high with the interclass correlation coefficient ranging from 0.77 to 0.97 across the frequencies.
Conclusions: Normative data of WBA measured at TPP and 0 daPa for neonates were provided in the present study. Although WBA at TPP was slightly higher than the WBA measured at 0 daPa at some frequencies below 2 kHz, the WBA patterns of the 2 measurements were nearly identical. Moreover, the test-retest reliability of both WBA measurements was high.