Affiliations 

  • 1 The Vibration Laboratory, School of Mechanical Engineering, Universiti Sains Malaysia, Engineering Campus, 14300, Nibong Tebal, Penang, Malaysia. cpingyi@hotmail.com
  • 2 The Vibration Laboratory, School of Mechanical Engineering, Universiti Sains Malaysia, Engineering Campus, 14300, Nibong Tebal, Penang, Malaysia
  • 3 Department of Medicine, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, 16150, Kubang Kerian, Kelantan, Malaysia
  • 4 Department of Neurosciences, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, 16150, Kubang Kerian, Kelantan, Malaysia
  • 5 Department of Neurology, Penang General Hospital, Residensi Road, 10990, Georgetown, Penang, Malaysia
  • 6 Department of Internal Medicine, Penang General Hospital, Residensi Road, 10990, Georgetown, Penang, Malaysia
  • 7 School of Civil Engineering, Universiti Sains Malaysia, Engineering Campus, 14300, Nibong Tebal, Penang, Malaysia
  • 8 Unit of Biostatistics and Research Methodology, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, 16150, Kubang Kerian, Kelantan, Malaysia
Sci Rep, 2019 05 31;9(1):8117.
PMID: 31148550 DOI: 10.1038/s41598-019-44142-1

Abstract

There is a lack of evidence that either conventional observational rating scale or biomechanical system is a better tremor assessment tool. This work focuses on comparing a biomechanical system and the Movement Disorder Society-sponsored revision of the Unified Parkinson's Disease Rating Scale in terms of test-retest reliability. The Parkinson's disease tremors were quantified by biomechanical system in joint angular displacement and predicted rating, as well as assessed by three raters using observational ratings. Qualitative comparisons of the validity and function are made also. The observational rating captures the overall severity of body parts, whereas the biomechanical system provides motion- and joint-specific tremor severity. The tremor readings of the biomechanical system were previously validated against encoders' readings and doctors' ratings; the observational ratings were validated with previous ratings on assessing the disease and combined motor symptoms rather than on tremor specifically. Analyses show that the predicted rating is significantly more reliable than the average clinical ratings by three raters. The comparison work removes some of the inconsistent impressions of the tools and serves as guideline for selecting a tool that can improve tremor assessment. Nevertheless, further work is required to consider more variabilities that influence the overall judgement.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.