OBJECTIVES: To validate the HACOR scale in predicting NIV failure among acute cardiogenic pulmonary oedema (ACPO) patients.
DESIGN, SETTINGS AND PARTICIPANTS: This is a prospective, observational study of consecutive ACPO patients requiring NIV admitted to the ED.
OUTCOME MEASURE AND ANALYSIS: Primary outcome was the ability of the HACOR score to predict NIV failure. Clinical, physiological, and HACOR score at baseline and at 1 h, 12 h and 24 h were analysed. Other potential predictors were assessed as secondary outcomes.
MAIN RESULTS: A total of 221 patients were included in the analysis. Fifty-four (24.4%) had NIV failure. Optimal HACOR score was >5 at 1 h after NIV initiation in predicting NIV failure (AUC 0.73, sensitivity 53.7%, specificity 83.2%). As part of the HACOR score, respiratory rate and heart rate were not found to be significant predictors. Other significant predictors of NIV failure in ACPO patients were acute coronary syndrome, acute kidney injury, presence of congestive heart failure as a comorbid, and the ROX index.
CONCLUSIONS: The HACOR scale measured at 1 h after NIV initiation predicts NIV failure among ACPO patients with acceptable accuracy. The cut-off level > 5 could be a useful clinical decision support tool in ACPO patient. However, clinicians should consider other factors such as the acute coronary and acute kidney diagnosis at presentation, presence of underlying congestive heart failure and the ROX index when clinically deciding on timely invasive mechanical ventilation.
OBJECTIVES: This study aimed to compare the outcomes of patients with moderate to severe TBI treated with Sterofundin (SF) versus NS.
DESIGN, SETTINGS AND PARTICIPANTS: A double-blinded randomised controlled trial of patients aged 18 to 65 years with TBI was conducted at the University Malaya Medical Centre from February 2017 to November 2019.
INTERVENTION OR EXPOSURE: Patients were randomly assigned to receive either NS or SF. The study fluids were administered for 72 h as continuous infusions or boluses. Participants, investigators, and staff were blinded to the fluid type.
OUTCOMES MEASURE AND ANALYSIS: The primary outcome was in-hospital mortality. Relative risk (RR) with 95% confidence interval (CI) was calculated.
MAIN RESULTS: A total of 70 patients were included in the analysis, with 38 in the NS group and 32 in the SF group. The in-hospital mortality rate were 3 (7.9%) in the NS group vs. 4 (12.5%) in the SF group, RR = 1.29 (95% CI, 0.64 to 2.59; p = 0.695). No patients developed AKI and required renal replacement therapy. ICP on day 3 was significantly higher in the SF group (18.60 ± 9.26) compared to 12.77 ± 3.63 in the NS group, (95% CI, -11.46 to 0.20; p = 0.037). There were no significant differences in 3-day biochemical parameters and cerebral perfusion pressure, ventilator-free days, length of ICU stay, or Glasgow Outcome Scale-Extended (GOS-E) score at 6 months.
CONCLUSIONS: In patients with moderate to severe TBI, the use of SF was not associated with reduced in-hospital mortality, development of AKI, or improved 6-month GOS-E when compared to NS.
METHODS: The urine samples were photographed in a customized photo box, under five simulated lighting conditions, using five smartphones. These images were analyzed using Adobe Photoshop to obtain urine Red, Green and Blue (RGB) values with and without colour correction. A commercially available colour calibration card was used for colour correction. Using intraclass correlation coefficient (ICC), inter-phone and intra-phone agreements of urine RGB values were analyzed.
RESULTS: Without colour correction, the various smartphones produced the highest agreement for Blue and Green values under the 'daylight' lighting condition. With colour correction, ICC values showed 'exceptional' inter-phone and intra-phone agreement for the Blue and Green values (ICC > 0.9). Red values showed 'poor' (ICC < 0.5) agreement with and without colour correction in all lighting conditions. Out of the five phones compared in this study, Phone 4 produced the lowest intra-phone agreement.
CONCLUSIONS: Colour calibration using photo colour cards improved the reliability of smartphone-based urine colorimetry, making this a promising point-of-care hydration assessment tool using the ubiquitous smartphone.
METHODS: CT scans of 50 lower limbs were analyzed. Key anatomical landmarks such as the medial epicondyle (ME), lateral epicondyle, and transepicondylar width (TEW) were determined on 3D models constructed from the CT images. Best-fit planes placed on the most distal and posterior loci of points on the femoral condyles were used to define the distal and posterior joint lines, respectively. Statistical analysis was performed to determine the relationships between the anatomical landmarks and the distal and posterior joint lines.
RESULTS: There was a strong correlation between the distance from the ME to the distal joint line of the medial condyle (MEDC) and the distance from the ME to the posterior joint line of the medial condyle (MEPC) (p
RESULTS: Numerical optimization showed that rice noodles prepared with SPI, 68.32 (g kg-1 of rice flour), MTG, 5.06 (g kg-1 of rice flour) and GDL, 5.0 (g kg-1 of rice flour) gave the best response variables; hardness (53.19 N), springiness (0.76), chewiness (20.28 J), tensile strength (60.35 kPa), and cooking time (5.15 min). The pH, sensory, and microstructure results showed that the optimized rice noodles had a more compact microstructure with fewer hollows, optimum pH for MTG action, and overall sensory panelists also showed the highest preference for the optimized formulation, compared to other samples selected from the numerical optimization and desirability tests.
CONCLUSION: Optimization of the levels of SPI, MTG, and GDL yielded quality noodles with improved textural, mechanical, sensory, and microstructural properties. This was partly due to the favourable pH value of the optimized noodles that provided the most suitable conditions for MTG crosslinking and balanced electrostatic interaction of proteins. © 2020 Society of Chemical Industry.
METHODS: This was a randomised cross-over study conducted between 9 April to 5 May 2020 in the ED of University Malaya Medical Centre. Postgraduate Emergency Medicine trainees performed video laryngoscope-assisted intubation on an airway manikin with and without an aerosol box in a random order. Contamination was simulated by nebulised Glo Germ. Primary outcome was number of contaminated front and back body regions pre-doffing and post-doffing of PPE of the intubator and assistant. Secondary outcomes were intubation time, Cormack-Lehane score, number of intubation attempts and participants' feedback.
RESULTS: Thirty-six trainees completed the study interventions. The number of contaminated front and back body regions pre-doffing of PPE was significantly higher without the aerosol box (all p values<0.001). However, there was no significant difference in the number of contaminations post-doffing of PPE between using and not using the aerosol box, with a median contamination of zero. Intubation time was longer with the aerosol box (42.5 s vs 35.5 s, p<0.001). Cormack-Lehane scores were similar with and without the aerosol box. First-pass intubation success rate was 94.4% and 100% with and without the aerosol box, respectively. More participants reported reduced mobility and visibility when intubating with the aerosol box.
CONCLUSIONS: An aerosol box may significantly reduce exposure to contaminations but with increased intubation time and reduced operator's mobility and visibility. Furthermore, the difference in degree of contamination between using and not using an aerosol box could be offset by proper doffing of PPE.
METHODS: The proximal tibia was resected as a single osteochondral unit during total knee replacement from patients (N = 10). The osteoarthritic chondrocytes were isolated from the osteochondral units, and characterized using reverse transcriptase-polymerase chain reaction. The isolated osteoarthritic chondrocytes were cultured and embedded in agarose, and then subjected to 10% and 20% uniaxial dynamic compression up to 8-days using a bioreactor. The morphological features and changes in the osteoarthritic chondrocytes upon compression were evaluated using scanning electron microscopy. Safranin O was used to detect the presence of cartilage matrix proteoglycan expression while quantitative analysis was conducted by measuring type VI collagen using an immunohistochemistry and fluorescence intensity assay.
FINDINGS: Gene expression analysis indicated that the isolated osteoarthritic chondrocytes expressed chondrocyte-specific markers, including BGN, CD90 and HSPG-2. Moreover, the compressed osteoarthritic chondrocytes showed a more intense and broader deposition of proteoglycan and type VI collagen than control. The expression of type VI collagen was directly proportional to the duration of compression in which 8-days compression was significantly higher than 4-days compression. The 20% compression showed significantly higher intensity compared to 10% compression in 4- and 8-days.
INTERPRETATION: The biosynthetic activity of human chondrocytes from osteoarthritic joints can be enhanced using selected compression regimes.
METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.
RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).
CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.
METHODS: One hundred computed tomography scans of disease-free knees were analyzed. A 3-dimensional reconstructed image of the tibia was generated and aligned to its anatomic axis in the coronal and sagittal planes. The tibia was then rotationally aligned to the tibial plateau (tibial centroid axis) and PTS was measured from best-fit planes on the surface of the proximal tibia and individually for the medial and lateral plateaus. This was then repeated with the tibia rotationally aligned to the ankle (transmalleolar axis).
RESULTS: When rotationally aligned to the tibial plateau, the mean PTS, medial PTS, and lateral PTS were 11.2° ± 3.0 (range, 4.7°-17.7°), 11.3° ± 3.2 (range, 2.7°-19.7°), and 10.9° ± 3.7 (range, 3.5°-19.4°), respectively. When rotationally aligned to the ankle, the mean PTS, medial PTS, and lateral PTS were 11.4° ± 3.0 (range, 5.3°-19.3°), 13.9° ± 3.7 (range, 3.1°-24.4°), and 9.7° ± 3.6 (range, 0.8°-17.7°), respectively.
CONCLUSION: The PTS in the normal Asian knee is on average 11° (mean) with a reference range of 5°-17° (mean ± 2 standard deviation). This has implications to surgery and implant design.
METHODS: Twelve fresh-frozen cadaveric knees were used. Five components of the quadriceps and the iliotibial band were loaded physiologically with 175N and 30N, respectively. The force required to displace the patella 10mm laterally and medially at 0°, 20°, 30°, 60° and 90° knee flexion was measured. Patellofemoral contact points at these knee flexion angles were marked. The trochlea cartilage geometry at these flexion angles was visualized by Computed Tomography imaging of the femora in air with no overlying tissue. The sulcus, medial and lateral facet angles were measured. The facet angles were measured relative to the posterior condylar datum.
RESULTS: The lateral facet slope decreased progressively with flexion from 23°±3° (mean±S.D.) at 0° to 17±5° at 90°. While the medial facet angle increased progressively from 8°±8° to 36°±9° between 0° and 90°. Patellar lateral stability varied from 96±22N at 0°, to 77±23N at 20°, then to 101±27N at 90° knee flexion. Medial stability varied from 74±20N at 0° to 170±21N at 90°. There were significant correlations between the sulcus angle and the medial facet angle with medial stability (r=0.78, p<0.0001).
CONCLUSIONS: These results provide objective evidence relating the changes of femoral profile geometry with knee flexion to patellofemoral stability.
METHODS: Focus group interviews were conducted to determine the construct of the questionnaire. Content and face validity were assessed by a panel of experts. A pilot study was conducted to validate the Sexual Dysfunction in Asian Men with Diabetes (SAD-MEN) questionnaire in English and Malay. The International Index of Erectile Function-5 (IIEF-5) was used for comparison. Construct validity was assessed using exploratory factor analysis, reliability was determined using Cronbach's α (> 0.700), and test-retest reliability using Spearman's rank correlation coefficient.
RESULTS: The SAD-MEN questionnaire yielded moderate face and content validity, with high reliability as shown by Cronbach's α values of 0.949 for sexual performance and 0.775 for sexual desire for the English version. The Malay language questionnaire had a Cronbach's α value of 0.945 for sexual performance and 0.750 for sexual desire. Test-retest reliability using Spearman's test gave correlation coefficients of r = 0.853, P = 0.000 for the English language questionnaire and r = 0.908, P = 0.000 for the Malay language questionnaire.
CONCLUSION: The SAD-MEN questionnaire is a valid and reliable tool by which to assess sexual dysfunction in English- and Malay-speaking Malaysian and South East Asian men with diabetes.
METHODS: The quadriceps of eight fresh-frozen knees were loaded on a custom-made jig. Kinematic data were recorded using an optical tracking device for the native knee, following total knee arthroplasty (TKA), then with patellar thicknesses from -2 to +4 mm, during knee extension motion. Staged lateral retinacular releases were performed to examine the restoration of normal patellar kinematics.
RESULTS: Compared to the native knee, TKA led to significant changes in patellofemoral kinematics, with significant increases in lateral shift, tilt and rotation. When patellar composite thickness was increased, the patella tilted further laterally. Lateral release partly corrected this lateral tilt but caused abnormal tibial external rotation. With complete release of the lateral retinaculum and capsule, the patella with an increased thickness of 4 mm remained more laterally tilted compared to the TKA with normal patellar thickness between 45° and 55° knee flexion and from 75° onwards. This was on average by 2.4° ± 2.9° (p