METHOD: This was a retrospective study in which high-resolution computed tomography images of paediatric patients with severe-to-profound sensorineural hearing loss were reviewed. A cochlear nerve canal diameter of 1.5 mm or less in the axial plane was classified as stenotic. Semicircular canals and other bony labyrinth morphology and abnormality were evaluated.
RESULTS: Cochlear nerve canal stenosis was detected in 65 out of 265 ears (24 per cent). Of the 65 ears, 17 ears had abnormal semicircular canals (26 per cent). Significant correlation was demonstrated between cochlear nerve canal stenosis and semicircular canal abnormalities (p < 0.01). Incomplete partition type II was the most common accompanying abnormality of cochlear nerve canal stenosis (15 out of 65, 23 per cent).
CONCLUSION: Cochlear nerve canal stenosis is statistically associated with semicircular canal abnormalities. Whenever a cochlear nerve canal stenosis is present in a patient with sensorineural hearing loss, the semicircular canal should be scrutinised for presence of abnormalities.
MATERIALS AND METHODS: This was a study involving LMS PCI coronary lesions using the Synergy Megatron DES. An IVUS protocol using predefined optimisation targets to evaluate for stent malapposition, longitudinal stent deformation, optimal stent expansion >90% of reference lumen and appropriate distal landing zone was used in all cases. The primary end-point was procedural success, defined by successful stent implantation with <30% residual stenosis. The secondary end-point was in-hospital and 30-day major adverse cardiovascular event (MACE).
RESULTS: Eight patients with significant LMS stenosis were successfully treated with the Megatron stent. The primary end-point was achieved in all patients. There were no cases of stent malapposition or longitudinal stent deformation, one case did not have optimal LMS stent expansion and one case did not have an appropriate distal landing zone. IVUS optimisation criteria were met in 6 (75%) cases. There were no complications of coronary dissection, slow or no reflow, stent thrombosis or vessel perforation. None of the patients suffered in-hospital or 30-day MACE. The average LMS MLD at baseline was 2.1 ± 0.1mm and the post-PCI LMS MLD was 4.0 ± 0.5mm, with a significant acute luminal gain of 1.9 ± 0.7mm (p<0.01). A post-PCI MSA of 17 ± 3.9 mm2 was numerically superior compared to those documented in other LMS PCI trials.
CONCLUSION: This study demonstrates low rates of shortterm major adverse cardiovascular events among patients with LMS PCI using the Megatron stents. It highlights the usefulness of IVUS-guided optimisation in LMS PCI. With the use of intravascular imaging, the new generation stent technology can improve the treatment of large proximal vessels and PCI of LMS lesions.
Case Description: A patient with cervical stenosis secondary to metastatic tumor in the intradural and extradural compartments presented with lower limb paraparesis. She underwent an uneventful tumor excision accompanied by posterior cervical decompression and fusion. Postoperatively, she was quadriplegic and required ventilator support. The emergent postoperative MR scan revealed focal hyperintensity on the T2-weighted image consistent with spinal cord edema extending into the lower brain stem.
Conclusion: Very few cases of reperfusion injury of the cervical spinal cord or "white cord syndrome" are described in the literature. Here we present a patient who, following cervical laminectomy and fusion for excision of metastatic tumor, developed quadriplegia. Notably, postoperative MR showed only findings of upper cervical cord and lower brain stem edema consistent with a "white cord syndrome" without other compressive pathology.