Displaying publications 1 - 20 of 75 in total

Abstract:
Sort:
  1. Low L, Abu Bakar A
    Sains Malaysiana, 2013;42:443-448.
    Hollow epoxy particles (HEP) serving as reinforcing fillers were prepared using the water-based emulsion method in this study. HEP was incorporated into the polyester matrix at various loading, ranging from 0 wt% to 9 wt%, to toughen the brittle polyester thermoset. The polyester composites were prepared using the casting technique. The fracture toughness and impact strength of the polyester composites increased with increasing the HEP loading up to 5 wt%, after which
    there was a drop. The improvement in fracture toughness and impact strength is attributed to the good polymer-filler interaction. This finding was further supported by the scanning electron micrograph, in which it was shown that the polyester resin was interlocked into the pore regions of the HEP filler. The reduction in fracture toughness and impact strength of the polyester composite were believed to be attributed to the filler agglomeration. This filler-filler interaction would create stress concentration areas and eventually weakened the interfacial adhesion between the polymer matrix and the filler particles. Hence, lower fracture toughness and impact strength of the highly HEP-filled polyester composites (above 5 wt%) were detected.
    Matched MeSH terms: Dental Materials
  2. Madfa AA, Kadir MR, Kashani J, Saidin S, Sulaiman E, Marhazlinda J, et al.
    Med Eng Phys, 2014 Jul;36(7):962-7.
    PMID: 24834856 DOI: 10.1016/j.medengphy.2014.03.018
    Different dental post designs and materials affect the stability of restoration of a tooth. This study aimed to analyse and compare the stability of two shapes of dental posts (parallel-sided and tapered) made of five different materials (titanium, zirconia, carbon fibre and glass fibre) by investigating their stress transfer through the finite element (FE) method. Ten three-dimensional (3D) FE models of a maxillary central incisor restored with two different designs and five different materials were constructed. An oblique loading of 100 N was applied to each 3D model. Analyses along the centre of the post, the crown-cement/core and the post-cement/dentine interfaces were computed, and the means were calculated. One-way ANOVAs followed by post hoc tests were used to evaluate the effectiveness of the post materials and designs (p=0.05). For post designs, the tapered posts introduced significantly higher stress compared with the parallel-sided post (p<0.05), especially along the centre of the post. Of the materials, the highest level of stress was found for stainless steel, followed by zirconia, titanium, glass fibre and carbon fibre posts (p<0.05). The carbon and glass fibre posts reduced the stress distribution at the middle and apical part of the posts compared with the stainless steel, zirconia and titanium posts. The opposite results were observed at the crown-cement/core interface.
    Matched MeSH terms: Dental Materials/chemistry*
  3. Al-Makramani BM, Razak AA, Abu-Hassan MI
    J Appl Oral Sci, 2010 Dec;18(6):607-12.
    PMID: 21308292
    Advances in all-ceramic systems have established predictable means of providing metal-free aesthetic and biocompatible materials. These materials must have sufficient strength to be a practical treatment alternative for the fabrication of crowns and fixed partial dentures.

    OBJECTIVES: The aim of this study was to compare the biaxial flexural strength of three core ceramic materials.

    MATERIAL AND METHODS: Three groups of 10 disc-shaped specimens (16 mm diameter x 1.2 mm thickness - in accordance with ISO-6872, 1995) were made from the following ceramic materials: Turkom-Cera Fused Alumina [(Turkom-Ceramic (M) Sdn Bhd, Puchong, Selangor, Malaysia)], In-Ceram (Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany) and Vitadur-N (Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany), which were sintered according to the manufacturer's recommendations. The specimens were subjected to biaxial flexural strength test in an universal testing machine at a crosshead speed of 0.5 mm/min. The definitive fracture load was recorded for each specimen and the biaxial flexural strength was calculated from an equation in accordance with ISO-6872.

    RESULTS: The mean biaxial flexural strength values were: Turkom-Cera: 506.8 ± 87.01 MPa, In-Ceram: 347.4 ± 28.83 MPa and Vitadur-N: 128.7 ± 12.72 MPa. The results were analyzed by the Levene's test and Dunnett's T3 post-hoc test (SPSS software V11.5.0 for Windows, SPSS, Chicago, IL, USA ) at a preset significance level of 5% because of unequal group variances (P<0.001). There was statistically significant difference between the three core ceramics (P<0.05). Turkom-Cera showed the highest biaxial flexural strength, followed by In-Ceram and Vitadur-N.

    CONCLUSIONS: Turkom-Cera core had significantly higher flexural strength than In-Ceram and Vitadur-N ceramic core materials.

    Matched MeSH terms: Dental Materials/chemistry*
  4. Ahmad Mahmood, Aws H. Ali Al-Kadhim, Zaripah Wan Bakar, Adam Husein
    Malaysian Dental Journal, 2011;32(1):12-16.
    MyJurnal
    Evaluation of the mechanical behaviour of restoration dental materials is essential to understand their performance under different load conditions and to estimate their durability under clinical oral function. Restorative materials and dental tissues like other materials by having specific mechanical properties, such as static strength (i.e. compressive strength, tensile strength, flexural strength) and dynamic strength (i.e. fatigue strength). The selection of proper mechanical test type depends on the goals that the study claims to define. On such basis, the mechanical test can be chosen correctly. Laboratory studies should be designed as replications of the clinical oral circumstances to measure the mechanical and physical properties of a material and any arbitrary choices in the design of the study may result in large variations of data.
    Matched MeSH terms: Dental Materials
  5. Norazean Shaari, Aidah Jumahat
    MyJurnal
    The effects of hole size on open hole tensile properties of Kevlar-glass fibre hybrid composite laminates were thoroughly investigated in this work. Woven Kevlar/glass fibre epoxy composite laminates were fabricated using hand lay-up and vacuum bagging technique. Specimens of five different hole size (1 mm, 4 mm, 6 mm, 8 mm and 12 mm) were carefully prepared before the tensile test was performed according to ASTM D5766. Results indicated that hybridizing Kevlar to glass fibres improved tensile strength and failure strain of hybrid composite specimen. In addition, increasing the hole size reduced strength retention of the hybrid specimen from 96% for 1 mm hole size to 62% and 44% for 6 mm and 12 mm, respectively. Fractography analysis showed that several types of failure mechanisms were observed such as brittle failure, ductile failure, fibre breakage, delamination and fibre-matrix splitting. It is concluded that as hole size increased, failure behaviour changed from a matrix dominated failure mode to a fibre-dominated failure mode.
    Matched MeSH terms: Dental Materials
  6. Zainab Shakir Radif, Aidy Ali
    MyJurnal
    The fracture behaviour represents the most critical issue in the automotive and aerospace engine fields. Thus, the objective of this study was to estimate and analyze the crack criteria by using the
    Mathematical laws that were limited in E 1820 standard and the results affirmed by applying the numerical solutions of ANSYS to estimate the fracture toughness value KIC, besides the energy release rate of biomass composite. The specimens were prepared from different percentage of kenaf mat (KM) and unsaturated polyester resin (UP) 20% KM – 80% UP and 40% KM – 60% UP, respectively, as well the other composite properties which were calculated using the stress-strain data. The fracture characterizations of this composite were carried out using the compact tension (CT) specimen that was commonly used to determine Mode-I fracture properties. The fracture toughness has been found to be independent of pre-crack length. Meanwhile, the tests were performed at room temperature. The numerical simulations of the ANSYS model results demonstrated a good agreement between the experiments computed results of the fracture toughness. The fracture toughness KIC of 20% KM – 80% UP and 40% KM – 60% UP was equivalent to 0.76 MPa√m and 2.0 MPa√m, respectively. Thus, the fracture propagation is dependent on the fibre percentage of the composite. On the other hand, there are unlimited mechanisms of crack paths derived from randomly kenaf mat packs, particularly in the frontal process zone of crack tip.
    Matched MeSH terms: Dental Materials
  7. Ahmed T, Rahman NA, Alam MK
    Eur J Dent, 2018 10 30;12(4):602-609.
    PMID: 30369810 DOI: 10.4103/ejd.ejd_22_18
    The aim of this study was to systematically review the available studies measuring the bond strength of orthodontic bracket-adhesive system under different experimental conditions in vivo. Literature search was performed in four different databases: PubMed, Web of Science, Cochrane, and Scopus using the keywords - bond strength, orthodontic brackets, bracket-adhesive, and in vivo. A total of six full-text articles were selected based on the inclusion and exclusion criteria of our study after a careful assessment by the two independent reviewers. Data selection was performed by following PRISMA 2009 guidelines. Five of the selected studies were clinical trials; one study was a randomized clinical trial. From each of the selected articles, the following data were extracted - number of samples, with the type of tooth involved materials under experiment methods of measurement, the time interval between bonding and debonding orthodontic brackets, mode of force application, and the bond strength results with the overall outcome. The methodological quality assessment of each article was done by the modified Downs and Black checklist method. The qualitative analyses were done by two independent reviewers. Conflicting issues were resolved in a consensus meeting by consulting the third reviewer (MKA). Meta-analysis could not be performed due to the lack of homogenous study results. The review reached no real conclusion apart from the lack of efforts to clinically evaluate the bonding efficiency of a wide range of orthodontic bracket-adhesive systems in terms of debonding force compared to laboratory-based in vitro and ex vivo studies.
    Matched MeSH terms: Dental Materials
  8. Razak AA, Abu-Hassan MI, Al-Makramani BM, Al-Sanabani FA, Al-Shami IZ, Almansour HM
    J Contemp Dent Pract, 2016 Nov 01;17(11):920-925.
    PMID: 27965501
    AIM: The aim of this study was to evaluate the effect of surface treatments on shear bond strength (SBS) of Turkom-Cera (Turkom-Ceramic (M) Sdn. Bhd., Puchong, Malaysia) all-ceramic material cemented with resin cement Panavia-F (Kuraray Medical Inc., Okayama, Japan).

    MATERIALS AND METHODS: Forty Turkom-Cera ceramic disks (10 mm × 3 mm) were prepared and randomly divided into four groups. The disks were wet ground to 1000-grit and subjected to four surface treatments: (1) No treatment (Control), (2) sandblasting, (3) silane application, and (4) sandblasting + silane. The four groups of 10 specimens each were bonded with Panavia-F resin cement according to manufacturer's recommendations. The SBS was determined using the universal testing machine (Instron) at 0.5 mm/min crosshead speed. Failure modes were recorded and a qualitative micromorphologic examination of different surface treatments was performed. The data were analyzed using the one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests.

    RESULTS: The SBS of the control, sandblasting, silane, and sandblasting + silane groups were: 10.8 ± 1.5, 16.4 ± 3.4, 16.2 ± 2.5, and 19.1 ± 2.4 MPa respectively. According to the Tukey HSD test, only the mean SBS of the control group was significantly different from the other three groups. There was no significant difference between sandblasting, silane, and sandblasting + silane groups.

    CONCLUSION: In this study, the three surface treatments used improved the bond strength of resin cement to Turkom-Cera disks.

    CLINICAL SIGNIFICANCE: The surface treatments used in this study appeared to be suitable methods for the cementation of glass infiltrated all-ceramic restorations.

    Matched MeSH terms: Dental Materials
  9. Jan J, Wan Bakar WZ, Mathews SM, Okoye LO, Ehler BR, Louden C, et al.
    J Investig Clin Dent, 2016 Nov;7(4):383-390.
    PMID: 26012784 DOI: 10.1111/jicd.12163
    OBJECTIVE: This study investigated the accuracy of the Canary System (CS) to detect proximal caries lesions in vitro, and compared it with conventional methods: International Caries Detection and Assessment System (ICDAS) II and bitewing radiography (BW).

    METHODS: Visible proximal surfaces of extracted human teeth were assessed by ICDAS-II before setting them in five manikin mouth models. Then contacting proximal surfaces in mouth models were assessed by BW and CS. Histological validation with polarized-light microscopy served as a gold standard. Pairwise comparisons were performed on area under the curve (AUC), sensitivity, and specificity of the three methods, and corrected using Bonferroni's method. Sensitivities and specificities were compared using a test of proportions and AUC values were compared using DeLong's method.

    RESULTS: The CS presented significantly higher sensitivity (0.933) than ICDAS-II (0.733, P = 0.01) and BW (0.267, P 

    Matched MeSH terms: Dental Materials/chemistry
  10. Amer AAR, Abdullah MMAB, Liew YM, A Aziz IH, Wysłocki JJ, Tahir MFM, et al.
    Materials (Basel), 2021 Feb 26;14(5).
    PMID: 33652863 DOI: 10.3390/ma14051094
    The demand for durable, resistant, and high-strength structural material has led to the use of fibers as reinforcing elements. This paper presents an investigation into the inclusion of chopped steel wool fibers (CSWFs) in cement to form a high-flexural strength cementitious composite matrix (CCM). CSWFs were used as the primary reinforcement in CCM at increments of 0.5 wt%, from 0.5-6 wt%, with ratios of cement to sand of 1:1.5 and water to cement of 0.45. The inclusion of CSWFs resulted in an excellent optimization of the physicomechanical properties of the CCM, such as its density (2.302 g/cm3), compressive strength (61.452 MPa), and maximum flexural strength (10.64 MPa), all of which exceeded the performances of other reinforcement elements reported in the literature.
    Matched MeSH terms: Dental Materials
  11. Siti Farhana Hisham, Ishak Ahmad, Rusli Daik, Anita Ramli
    Sains Malaysiana, 2011;40:1179-1186.
    In this study, poly(ethylene terephthalate) (PET) wastes bottle was recycled by glycolysis process using ethylene glycol. The unsaturated polyester resin (UPR) was then prepared by reacting the glycolysed product with maleic anhydride. The blend of UPR based on recycled PET wastes with liquid natural rubber (LNR) was carried out by varying the amount of LNR from 0 to 7.5 wt%. Mechanical tests such as tensile and impact were conducted to investigate the effects of LNR on the mechanical properties. Scanning Electron Microscopy (SEM) was used to analyze the morphology of the breaking area resulted from the tensile tests on the UPR and blend samples. From the results, the blend of 2.5 wt% LNR in UPR based recycled PET wastes achieved the highest strength in the mechanical properties and showed a well dispersed of elastomer particles in the sample morphology compared to other blends concentrations. This blend sample was then compared to the optimum blend of LNR with commercial resin through the glass transition temperature value Tg, mechanical strength and morphology properties. The comparison study showed that the Tg for UPR based recycled PET was higher than the value represented from commercial resin due to the degree of crystalinity in the molecular structure of the materials. LNR was found to be an effective impact modifier which gave a greater improvement in UPR from recycled PET wastes structure but not to the commercial one which needs 5% LNR to achieve the optimum properties. Thus, the compatibility between the UP resin based recycled PET and LNR was much better than with the commercial resin.
    Matched MeSH terms: Dental Materials
  12. Md Zin N, Al-Fakih A, Nikbakht E, Teo W, Anwar Gad M
    Materials (Basel), 2019 Dec 11;12(24).
    PMID: 31835775 DOI: 10.3390/ma12244159
    An experimental study is conducted to determine the influence of secondary reinforcement on the behaviour of corbels fabricated with three different types of high-performance fiber-reinforced cementitious composites, including engineered cementitious concrete (ECC); high-performance steel fiber-reinforced composite (HPSFRC); and hybrid fiber-reinforced composite (HyFRC). Two shear span-to-depth ratios (a/d = 0.75 and 1.0) are explored. The mechanical properties of the composites in terms of tensile, compressive, and flexural strengths are investigated. Next, the structural behaviour of the high-performance cementitious composite corbels in terms of ultimate load capacity, ductility, and failure modes under the three-point bending test are investigated. The secondary reinforcement is proven to significantly affect stiffness and ultimately load capacity of all three high-performance composite corbels with an aspect ratio of 0.75. However, the secondary reinforcement was more impactful for the HPSFRC corbels, with 51% increase of ultimate strength. Moreover, in terms of damage, fewer cracks occurred in ECC corbels. HPSFRC corbels displayed the highest level of ductility and deformation capacity compared to the other specimens. The results were comparatively analyzed against the predicted results using truss and plastic truss models which provided relatively reliable shear strength.
    Matched MeSH terms: Dental Materials
  13. Sapuan SM, Aulia HS, Ilyas RA, Atiqah A, Dele-Afolabi TT, Nurazzi MN, et al.
    Polymers (Basel), 2020 Sep 27;12(10).
    PMID: 32992450 DOI: 10.3390/polym12102211
    This work represents a study to investigate the mechanical properties of longitudinal basalt/woven-glass-fiber-reinforced unsaturated polyester-resin hybrid composites. The hybridization of basalt and glass fiber enhanced the mechanical properties of hybrid composites. The unsaturated polyester resin (UP), basalt (B) and glass fibers (GF) were fabricated using the hand lay-up method in six formulations (UP, GF, B7.5/G22.5, B15/G15, B22.5/G7.5 and B) to produce the composites, respectively. This study showed that the addition of basalt to glass-fiber-reinforced unsaturated polyester resin increased its density, tensile and flexural properties. The tensile strength of the B22.5/G7.5 hybrid composites increased by 213.92 MPa compared to neat UP, which was 8.14 MPa. Scanning electron microscopy analysis was used to observe the fracture mode and fiber pullout of the hybrid composites.
    Matched MeSH terms: Dental Materials
  14. Norazlina Mohammad, Abdul Azim Asy Abdul Aziz, Aimi Amalina Ahmad, Azlan Jaafar, Aws H Ali Al-Kadhim
    MyJurnal
    Dentist-related factors are one of the major influences on the material selection for
    restoration of carious and non-carious tooth surface loss. There were conflicting results regarding
    the impact of dentists' gender and age or length of clinical experience on restorative material
    selection for posterior dentition. The aims of this study were to determine the influence of gender
    and clinical experience on posterior restorative material selection among private dental
    practitioner in Malaysia. (Copied from article).
    Matched MeSH terms: Dental Materials
  15. Ayatollahi MR, Yahya MY, Karimzadeh A, Nikkhooyifar M, Ayob A
    PMID: 26046269 DOI: 10.1016/j.msec.2015.05.004
    The aim of this study was to investigate the effects of temperature change and immersion in two common beverages on the mechanical and tribological properties for three different types of dental restorative materials. Thermocycling procedure was performed for simulating temperature changes in oral conditions. Black tea and soft drink were considered for beverages. Universal composite, universal nanohybrid composite and universal nanofilled composite, were used as dental materials. The nanoindentation and nanoscratch experiments were utilized to determine the elastic modulus, hardness, plasticity index and wear resistance of the test specimens. The results showed that thermocycling and immersion in each beverage had different effects on the tested dental materials. The mechanical and tribological properties of nanohybrid composite and nanocomposite were less sensitive to temperature change and to immersion in beverages in comparison with those of the conventional dental composite.
    Matched MeSH terms: Dental Materials/chemistry*
  16. Elshereksi NW, Ghazali MJ, Muchtar A, Azhari CH
    J Dent, 2017 Jan;56:121-132.
    PMID: 27916635 DOI: 10.1016/j.jdent.2016.11.012
    OBJECTIVES: This study aimed to fabricate and characterise silanated and titanated nanobarium titanate (NBT) filled poly(methyl methacrylate) (PMMA) denture base composites and to evaluate the behaviour of a titanate coupling agent (TCA) as an alternative coupling agent to silane. The effect of filler surface modification on fracture toughness was also studied.

    METHODS: Silanated, titanated and pure NBT at 5% were incorporated in PMMA matrix. Neat PMMA matrix served as a control. NBT was sonicated in MMA prior to mixing with the PMMA. Curing was carried out using a water bath at 75°C for 1.5h and then at 100°C for 30min. NBT was characterised via Fourier transform-infrared spectroscopy (FTIR), Transmission Electron Microscopy (TEM) and Brunauer-Emmett-Teller (BET) analysis before and after surface modification. The porosity and fracture toughness of the PMMA nanocomposites (n=6, for each formulation and test) were also evaluated.

    RESULTS: NBT was successfully functionalised by the coupling agents. The TCA exhibited the lowest percentage of porosity (0.09%), whereas silane revealed 0.53% porosity. Statistically significant differences in fracture toughness were observed among the fracture toughness values of the tested samples (p<0.05). While the fracture toughness of untreated samples was reduced by 8%, an enhancement of 25% was achieved after titanation. In addition, the fracture toughness of the titanated samples was higher than the silanated ones by 10%.

    CONCLUSION: Formation of a monolayer on the surface of TCA enhanced the NBT dispersion, however agglomeration of silanated NBT was observed due to insufficient coverage of NBT surface. Such behaviour led to reducing the porosity level and improving fracture toughness of titanated NBT/PMMA composites. Thus, TCA seemed to be more effective than silane.

    CLINICAL SIGNIFICANCE: Minimising the porosity level could have the potential to reduce fungus growth on denture base resin to be hygienically accepTable Such enhancements obtained with Ti-NBT could lead to promotion of the composites' longevity.

    Matched MeSH terms: Dental Materials/chemistry
  17. Elshereksi NW, Ghazali M, Muchtar A, Azhari CH
    Dent Mater J, 2017 Sep 26;36(5):539-552.
    PMID: 28652551 DOI: 10.4012/dmj.2016-014
    Silane is a dominant coupler that is widely used in dentistry to promote adhesion among the components of dental composites. Silica-based fillers can be easily silanized because of their similarly ordered structure. However, silane is hydrolytically degraded in the aqueous oral environment and inefficiently bonds to non-silica fillers. Thus, the development of hydrolytically stable dental composites is an important objective in the research on dental materials. Titanate coupling agents (TCAs) exhibit satisfactory interfacial bonding, enhanced homogeneous filler dispersion, and improved mechanical properties of the composites. Titanates also provide superior hydrolytic stability in wet environments, which should be considered in fabricating dental composites. The addition of a small amount of titanates can improve the resistance of the composites to moisture. This paper reviews the effects of the instability of silanes in moisture on the performance of dental composites and presents TCAs as alternative couplers to silanes for fabricating dental composites.
    Matched MeSH terms: Dental Materials*
  18. Gonzalez, M.A.G., Kasim, N.H.A., Aziz, R.A.
    Ann Dent, 1997;4(1):-.
    MyJurnal
    Microleakage testing has been used to determine the possible clinical performance of a restorative material. Many microleakage testing materials have been developed and performed through the years. There has been no agreement as to which testing methodology would give the most accurate results. Attempts have been made to simulate the oral conditions and to give a more quantitative representation of micro leakage. The different micro leakage testing methodologies are presented in this paper.
    Matched MeSH terms: Dental Materials
  19. Huseien GF, Sam ARM, Faridmehr I, Baghban MH
    Materials (Basel), 2021 Mar 06;14(5).
    PMID: 33800835 DOI: 10.3390/ma14051255
    This research investigated the application of epoxy resin polymer as a self-healing strategy for improving the mechanical and durability properties of cement-based mortar. The epoxy resin was added to the concrete mix at various levels (5, 10, 15, and 20% of cement weight), and the effectiveness of healing was evaluated by microstructural analysis, compressive strength, and non-destructive (ultrasonic pulse velocity) tests. Dry and wet-dry conditions were considered for curing, and for generating artificial cracks, specimens at different curing ages (1 and 6 months) were subjected to compressive testing (50 and 80% of specimen's ultimate compressive strength). The results indicated that the mechanical properties in the specimen prepared by 10% epoxy resin and cured under wet-dry conditions was higher compared to other specimens. The degree of damage and healing efficiency index of this particular mix design were significantly affected by the healing duration and cracking age. An optimized artificial neural network (ANN) combined with a firefly algorithm was developed to estimate these indexes over the self-healing process. Overall, it was concluded that the epoxy resin polymer has high potential as a mechanical properties self-healing agent in cement-based mortar.
    Matched MeSH terms: Dental Materials
  20. Choo YSL, Giamberini M, Reina JA, Waddell PG, Benniston AC
    Org Biomol Chem, 2020 Nov 25;18(45):9316.
    PMID: 33179703 DOI: 10.1039/d0ob90154g
    Correction for 'Functionalized fluorescent terephthalate monomers and their attempted polyester formation' by Yvonne S. L. Choo et al., Org. Biomol. Chem., 2020, 18, 8735-8745, DOI: 10.1039/D0OB01533D.
    Matched MeSH terms: Biomedical and Dental Materials
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links