CASE REPORT: A 5-year-old Malay boy with a history of recurrent pneumonia, presented with productive cough, fever and worsening tachypnoea. Physical examination revealed coarse crepitations, reduced breath sounds and clubbing. Biochemical investigations showed that he had respiratory type 2 failure as a result of bronchiectasis. Sweat conductivity done twice was raised supporting a diagnosis of CF. Other investigations such as bronchoscopy to look for congenital anomaly of the lung, infectious disease screening and tuberculosis, fungal and viral culture and sensitivity were negative. Further cascade screening revealed high sweat conductivity results in his siblings.
DISCUSSION: Although CF prevalence is low in Malaysia, it is nevertheless an important diagnosis to be recognised as it is associated with increased morbidity.
AIM: The objective of this study was to compare the diagnostic accuracy of mRDT CareStatTM with microscopy.
SETTING: This study was conducted in the paediatric primary care clinic of the Federal Medical Centre, Asaba, Nigeria.
METHODS: A cross-sectional study for diagnostic accuracy was conducted from May 2016 to October 2016. Ninety-eight participants were involved to obtain a precision of 5%, sensitivity of mRDT CareStatTM of 95% from published work and 95% level of confidence after adjusting for 20% non-response rate or missing data. Consecutive participants were tested using both microscopy and mRDT. The results were analysed using EPI Info Version 7.
RESULTS: A total of 98 children aged 3-59 months were enrolled. Malaria prevalence was found to be 53% (95% confidence interval [CI] = 46% - 60%), whilst sensitivity and specificity were 29% (95% CI = 20% - 38%) and 89% (95% CI = 83% - 95%), respectively. The positive and negative predictive values were 75% (95% CI = 66.4% - 83.6%) and 53% (95% CI = 46% - 60%), respectively.
CONCLUSION: Agreement between malaria parasitaemia using microscopy and mRDT positivity increased with increase in the parasite density. The mRDT might be negative when malaria parasite density using microscopy is low.
DESIGN AND METHODS: The activity of DPD was measured using 5-[2- (14)C]Fluorouracil (5-[2-(14)C]FUra) followed by separation of substrate and product 5-[2-(14)C]FUraH(2) with a 15 x 4.6 mm I.D., 5 microm particle size (d(p)) porous graphitic carbon (PGC) column (Hypercarb(R)) and HPLC with online detection of the radioactivity. This was standardized using the protein concentration of the cytosol (NanoOrange(R) Protein Quantitation).
RESULTS: Complete baseline separation of 5-[2-(14)C]Fluorouracil (5-[2-(14)C]FUra) and 5-[2-(14)C]Fluoro-5,6-dihydrouracil (5-[2-(14)C]FUraH(2)) was achieved using a porous graphitic carbon (PGC) column. The detection limit for 5-[2-(14)C]FUraH(2) was 0.4 pmol.
CONCLUSIONS: By using linear gradient separation (0.1% Trifluoroacetic acid [TFA] in water to 100% Methanol) protocols in concert with PGC columns (Hypercarb(R)), we have demonstrated that a PGC column has a distinct advantage over C-18 reverse phase columns in terms of column stability (pH 1-14). This method provides an improvement on the specific assay for DPD enzyme activity. It is rapid, reproducible and sensitive and can be used for routine screening for healthy and cancer patients for partial and profound DPD deficiency before treatment with 5- FUra.
METHODOLOGY: We retrospectively reviewed computerized medical records of adults with suspected UTI between July-December 2016. Excluded were consultations misclassified by the search engine, duplicated records of the same patient, consultations for follow-up of suspected UTI, patients who were pregnant, catheterised, or who had a renal transplant. Records were reviewed by two primary care physicians and a clinical microbiologist.
RESULTS: From 852 records, 366 consultations were a fresh episode of possible UTI. Most subjects were female (78.2%) with median age of 61.5 years. The major co-morbidities were hypertension (37.1%), prostatic enlargement in males (35.5%) and impaired renal function (31.1%). Symptoms were reported in 349 (95.4%) consultations. Antibiotics were prescribed in 307 (83.9%) consultations, which was appropriate in 227/307 (73.9%), where the subject had at least one symptom, and leucocytes were raised in urine full examination and microscopic examination (UFEME). In 73 (23.8%) consultations antibiotics were prescribed inappropriately, as the subjects were asymptomatic (14,4.6%), urine was clear (17,5.5%), or UFEME did not show raised leucocytes (42,13.7%). In 7 (2.3%) consultations appropriateness of antibiotics could not be determined as UFEME was not available.
CONCLUSION: Several pitfalls contributed to suboptimal adherence to guidelines for diagnosis and management of suspected UTI. This illustrates the complexity of managing suspected UTI in older subjects with multiple co-morbidities.
METHODS: This study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis for Diagnostic Test Accuracy (PRISMA-DTA) guideline. Relevant studies in the health-related electronic databases were searched. According to the criteria set for this study, eligible studies were identified. The quality of included studies was evaluated with the use of a quality assessment checklist. A summary performance estimates such as pooled sensitivity and specificity were stratified by type of LAMP. Bivariate model for data analyses was applied. Summary receiver operating characteristics plots were created to display the results of individual studies in a receiver operating characteristics space. Meta-regression analysis was performed to investigate the sources of heterogeneity among individual studies.
RESULTS: Twenty-seven studies across 17 endemic countries were identified. The vast majority of studies were with unclear risk of bias in the selection of index test. Overall, the pooled test performances were high for Pan LAMP (sensitivity: 0.95, 95% CI 0.91 to 0.97; specificity: 0.98, 95% CI 0.95 to 0.99), Plasmodium falciparum (Pf) LAMP (sensitivity: 0.96, 95% CI 0.94 to 0.98; specificity: 0.99, 95% CI 0.96 to 1.00) or for Plasmodium vivax (Pv) LAMP from 6 studies (sensitivity: 0.98, 95% CI 0.92 to 0.99; specificity: 0.99, 95% CI 0.72 to 1.00). The area under the curve for Pan LAMP (0.99, 95% CI 0.98-1.00), Pf LAMP (0.99, 95% CI 0.97-0.99) and Pv LAMP was (1.00, 95% CI 0.98-1.00) indicated that the diagnostic performance of these tests were within the excellent accuracy range. Meta-regression analysis showed that sample size had the greatest impact on test performance, among other factors.
CONCLUSIONS: The current findings suggest that LAMP-based assays are appropriate for detecting low-level malaria parasite infections in the field and would become valuable tools for malaria control and elimination programmes. Future well-designed larger sample studies on LAMP assessment in passive and active malaria surveillances that use PCR as the reference standard and provide sufficient data to construct 2 × 2 diagnostic table are needed.
Methods: A nationwide representative provider survey amongst community health centres (CHCs) using randomized stratified sampling methods was conducted between September and December 2015. One hundred and eighty CHCs and frontline primary care practitioners from 20 cities across three administrative regions of Western, Central and Eastern China were invited to participate.
Results: One hundred and forty-nine clinicians-in-charge (79%), 1734 doctors and 1846 nurses participated (86%). Majority of CHCs (80%, 95% CI: 74-87) offered hepatitis B testing, but just over half (55%, 95% CI: 46-65) offered hepatitis C testing. The majority of doctors (87%) and nurses (85%) felt that there were benefits for providing hepatitis testing at CHCs. The major barriers for not offering hepatitis testing were lack of training (54%) and financial support (23%). Multivariate analysis showed that the major determinants for CHCs to offer hepatitis B and C testing were the number of nurses (AOR 1.1) and written policies for hepatitis B diagnosis (AOR 12.7-27.1), and for hepatitis B the availability of reproductive health service.
Conclusions: Primary care providers in China could play a pivotal role in screening, diagnosing and treating millions of people with chronic hepatitis B and C in China.
RESULTS: A noticeable variation between the RDT (Alltest Biotech, China) and nPCR results was observed, for RDT 78% (46/59) were P. falciparum positive, 6.8% (4/59) were co-infected with both P. falciparum and Plasmodium vivax, 15.3% (9/59) were negative by the RDT. However, when the nPCR was applied only 44.1% (26/59) and 55.9% (33/59) was P. falciparum positive and negative respectively. The pfhrp2 was further amplified form all nPCR positive samples. Only 17 DNA samples were positive from the 26 positive P. falciparum, interestingly, variation in band sizes was observed and further confirmed by DNA sequencing, and sequencing analysis revealed a high-level of genetic diversity of the pfhrp2 gene in the parasite population from the study area. However, despite extreme sequence variation, diversity of PfHRP2 does not appear to affect RDT performance.