Displaying publications 1 - 20 of 166 in total

Abstract:
Sort:
  1. Gan X, Gong T, Zheng Y, Gopinath SCB, Zhao K
    Biotechnol Appl Biochem, 2021 Apr;68(2):272-278.
    PMID: 32275089 DOI: 10.1002/bab.1921
    C-reactive protein (CRP) is an acute phase reactant to be a marker of inflammation and has been correlated with the cardiac injury. An immunoassay was performed using anti-human CRP antibody on an InterDigitated electrode (IDE) sensor to determine and specify CRP concentration for diagnosing the condition of myocardial inflammation. To promote the detection, gold nanoparticle (GNP) was seeded on the aminated-IDE surface. Anti-CRP was hitched on the GNP-seeded surface and identified the abundance of CRP. The limit of quantification was found as 100 fM, and the higher current response was noticed by increasing CRP concentrations with the sensitivity at 1 pM. Furthermore, CRP-spiked human serum did not interfere the determination of CRP and increased the current response, indicating suitability for a real-life sample. Similarly, the control experiments with nonimmune antibody Troponin I are not showing the definite current responses, proving the selective identification of CRP. This method of diagnosing is needful to determine the cardiovascular injury at the right time.
    Matched MeSH terms: Electrochemical Techniques*
  2. Liu Z, Gopinath SCB, Wang Z, Li Y, Anbu P, Zhang W
    Mikrochim Acta, 2021 05 15;188(6):187.
    PMID: 33990848 DOI: 10.1007/s00604-021-04834-w
    A new zeolite-iron oxide nanocomposite (ZEO-IO) was extracted from waste fly ash of a thermal power plant and utilized for capturing aptamers used to quantify the myocardial infarction (MI) biomarker N-terminal prohormone B-type natriuretic peptide (NT-ProBNP); this was used in a probe with an integrated microelectrode sensor. High-resolution microscopy revealed that ZEO-IO displayed a clubbell structure and a particle size range of 100-200 nm. Energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy confirmed the presence of Si, Al, Fe, and O in the synthesized ZEO-IO. The limit of detection for NT-ProBNP was 1-2 pg/mL (0.1-0.2 pM) when the aptamer was sandwiched with antibody and showed the doubled current response even at a low NT-ProBNP abundance. A dose-dependent interaction was identified for this sandwich with a linear plot in the concentration range 1 to 32 pg/mL (0.1-3.2 pM) with a determination coefficient R2 = 0.9884; y = 0.8425x-0.5771. Without  sandwich, the detection limit was 2-4 pg/mL (0.2-0.4 pM) and the determination coefficient was R2 = 0.9854; y = 1.0996x-1.4729. Stability and nonfouling assays in the presence of bovine serum albumin, cardiac troponin I, and myoglobin revealed that the aptamer-modified surface is stable and specific for NT-Pro-BNP. Moreover, NT-ProBNP-spiked human serum exhibited selective detection. This new nanocomposite-modified surface helps in detecting NT-Pro-BNP and diagnosing MI at stages of low expression.
    Matched MeSH terms: Electrochemical Techniques/instrumentation; Electrochemical Techniques/methods
  3. Abu Ismaiel A, Aroua MK, Yusoff R
    Sensors (Basel), 2014 Jul 21;14(7):13102-13.
    PMID: 25051034 DOI: 10.3390/s140713102
    In this study, a potentiometric sensor composed of palm shell activated carbon modified with trioctylmethylammonium thiosalicylate (TOMATS) was used for the potentiometric determination of mercury ions in water samples. The proposed potentiometric sensor has good operating characteristics towards Hg (II), including a relatively high selectivity; a Nernstian response to Hg (II) ions in a concentration range of 1.0 × 10(-9) to 1.0 × 10(-2) M, with a detection limit of 1 × 10(-10) M and a slope of 44.08 ± 1.0 mV/decade; and a fast response time (~5 s). No significant changes in electrode potential were observed when the pH was varied over the range of 3-9. Additionally, the proposed electrode was characterized by good selectivity towards Hg (II) and no significant interferences from other cationic or anionic species.
    Matched MeSH terms: Electrochemical Techniques/instrumentation*
  4. Rashid JIA, Kannan V, Ahmad MH, Mon AA, Taufik S, Miskon A, et al.
    Mater Sci Eng C Mater Biol Appl, 2021 Jan;120:111625.
    PMID: 33545813 DOI: 10.1016/j.msec.2020.111625
    Multidrug resistant Pseudomonas aeruginosa (P. aeruginosa) is known to be a problematic bacterium for being a major cause of opportunistic and nosocomial infections. In this study, reduced graphene oxide decorated with gold nanoparticles (AuNPs/rGO) was utilized as a new sensing material for a fast and direct electrochemical detection of pyocyanin as a biomarker of P. aeruginosa infections. Under optimal condition, the developed electrochemical pyocyanin sensor exhibited a good linear range for the determination of pyocyanin in phosphate-buffered saline (PBS), human saliva and urine at a clinically relevant concentration range of 1-100 μM, achieving a detection limit of 0.27 μM, 1.34 μM, and 2.3 μM, respectively. Our developed sensor demonstrated good selectivity towards pyocyanin in the presence of interfering molecule such as ascorbic acid, uric acid, NADH, glucose, and acetylsalicylic acid, which are commonly found in human fluids. Furthermore, the developed sensor was able to discriminate the signal with and without the presence of pyocyanin directly in P. aeruginosa culture. This proposed technique demonstrates its potential application in monitoring the presence of P. aeruginosa infection in patients.
    Matched MeSH terms: Electrochemical Techniques
  5. Yu CY, Ang GY, Yean CY
    Chem Commun (Camb), 2013 Mar 11;49(20):2019-21.
    PMID: 23370051 DOI: 10.1039/c3cc39144b
    We developed a multiplex enzyme-based electrochemical genosensor for sequence-specific detection of multiplex linear-after-the-exponential-PCR amplicons that targeted toxigenic Vibrio cholerae O1 and O139 using novel screen-printed gold electrode bisensors.
    Matched MeSH terms: Electrochemical Techniques*
  6. Low KF, Zain ZM, Yean CY
    Biosens Bioelectron, 2017 Jan 15;87:256-263.
    PMID: 27567251 DOI: 10.1016/j.bios.2016.08.064
    A novel enzyme/nanoparticle-based DNA biosensing platform with dual colorimetric/electrochemical approach has been developed for the sequence-specific detection of the bacterium Vibrio cholerae, the causative agent of acute diarrheal disease in cholera. This assay platform exploits the use of shelf-stable and ready-to-use (shelf-ready) reagents to greatly simplify the bioanalysis procedures, allowing the assay platform to be more amenable to point-of-care applications. To assure maximum diagnosis reliability, an internal control (IC) capable of providing instant validation of results was incorporated into the assay. The microbial target, single-stranded DNA amplified with asymmetric PCR, was quantitatively detected via electrochemical stripping analysis of gold nanoparticle-loaded latex microspheres as a signal-amplified hybridization tag, while the incorporated IC was analyzed using a simplified horseradish peroxidase enzyme-based colorimetric scheme by simple visual observation of enzymatic color development. The platform showed excellent diagnostic sensitivity and specificity (100%) when challenged with 145 clinical isolate-spiked fecal specimens. The limits of detection were 0.5ng/ml of genomic DNA and 10 colony-forming units (CFU)/ml of bacterial cells with dynamic ranges of 0-100ng/ml (R(2)=0.992) and log10 (1-10(4) CFU/ml) (R(2)=0.9918), respectively. An accelerated stability test revealed that the assay reagents were stable at temperatures of 4-37°C, with an estimated ambient shelf life of 200 days. The versatility of the biosensing platform makes it easily adaptable for quantitative detection of other microbial pathogens.
    Matched MeSH terms: Electrochemical Techniques/instrumentation; Electrochemical Techniques/methods*
  7. Wang S, Su S, Yu C, Gopinath SCB, Yang Z
    Biotechnol Appl Biochem, 2021 Aug;68(4):726-731.
    PMID: 32621620 DOI: 10.1002/bab.1981
    The urinary C-terminal telopeptide fragment of type II collagen (uCTX-II) has been reported as the efficient blood-based biomarker for osteoarthritis, which affects knees, hands, spine, and hips. This study reports a sensing strategy with antibody-conjugated gold nanoparticles (GNP) on an interdigitated electrode (IDE) to determine uCTX-II. The GNP-antibody complex was chemically immobilized on the IDE surface through the amine linker. uCTX-II was determined by monitoring the alteration in current upon interacting the GNP-complexed antibody. This strategy was improved the detection by attracting higher uCTX-II molecules, and the detection limit falls in the range of 10-100 pM with an acceptable regression value [y = 0.6254x - 0.4073, R² = 0.9787]. The sensitivity of the detection was recognized at 10 pM. Additionally, upon increasing the uCTX-II concentration, the current changes were increased in a linear fashion. Control detection with nonimmune antibody and control protein do not increase the current level, confirming the specific detection of uCTX-II. This method of detection helps in diagnosing osteoarthritis and its follow-up treatment.
    Matched MeSH terms: Electrochemical Techniques*
  8. Lin J, Gopinath SCB, Lakshmipriya T, Chen Y, Yuan WR, Yang M
    Int J Biol Macromol, 2019 Dec 01;141:564-569.
    PMID: 31493451 DOI: 10.1016/j.ijbiomac.2019.09.012
    Human papilloma virus (HPV) affects predominantly the genital area, which includes vagina, cervix, penis, vulva scrotum, rectum and anus. Among 100 types of HPV, 14 types are considered to cause the risky cancer. The gene HPV-16 E7 is responsible for the development of cancer with the infected women. Earlier identification of this gene sequence avoids the cancer progression. The targeted HPV-16 E7 sequence was sandwiched by capture and reporter sequences on the carbodiimidazole-modified interdigitated electrode (IDE) surface. Target sequence at 100 f. was paired to the capture sequence immobilized on IDE sensing surface. To this surface, different concentrations of reporter sequence with and without gold rod (GNR) were evaluated. In both cases the detections were attained 1 aM by the reporter sequence pairing and with GNR increments in current were found. This enhancement was found to be 1000 folds, considering the condition was revealed in the absence of reporter. This sandwich detection strategy of capture-target-reporter sequences for HPV-16 detection on the IDE sensing surface helps to diagnose the association of cervical cancer.
    Matched MeSH terms: Electrochemical Techniques*
  9. Han H, Sabani NB, Nobusawa K, Takei F, Nakatani K, Yamashita I
    Anal Chem, 2023 Jul 04;95(26):9729-9733.
    PMID: 37341999 DOI: 10.1021/acs.analchem.3c01126
    We have developed a DNA sensor that can be finalized to detect a specific target on demand. The electrode surface was modified with 2,7-diamino-1,8-naphthyridine (DANP), a small molecule with nanomolar affinity for the cytosine bulge structure. The electrode was immersed in a solution of synthetic probe-DNA that had a cytosine bulge structure at one end and a complementary sequence to the target DNA at the other end. The strong binding between the cytosine bulge and DANP anchored the probe DNAs to the electrode surface, and the electrode became ready for target DNA sensing. The complementary sequence portion of the probe DNA can be changed as requested, allowing for the detection of a wide variety of targets. Electrochemical impedance spectroscopy (EIS) with the modified electrode detected target DNAs with a high sensitivity. The charge transfer resistance (Rct) extracted from EIS showed a logarithmic relationship with the concentration of target DNA. The limit of detection (LoD) was less than 0.01 μM. By this method, highly sensitive DNA sensors for various target sequences could be easily produced.
    Matched MeSH terms: Electrochemical Techniques/methods
  10. Gopinath SCB, Xuan S
    Biotechnol Appl Biochem, 2021 Jun;68(3):554-559.
    PMID: 32460382 DOI: 10.1002/bab.1961
    One of the current issues with thyroid tumor is early diagnosis as it makes the higher possibility of curing. This research was focused to detect and quantify the level of specific target sequence complementation of miR-222 with capture DNA sequence on interdigitated electrode (IDE) sensor. The aluminum electrode with the gap and finger sizes of 10 µm was fabricated on silicon wafer, further the surface was amine-functionalized for accommodating carboxylated-DNA probe. With DNA-target RNA complementation, the detection limit was attained to be 1 fM as estimated by a linear regression analysis [y = 1.5325x - 2.1171 R² = 0.9065] and the sensitivity was at the similar level. Current responses were higher by increasing the target RNA sequence concentrations. Control experiments with mismatched/noncomplementary sequences were failed to complement the capture DNA sequence immobilized on IDE, indicating the specific target validation. This research helps diagnosing and identifying the progression with thyroid tumor and miRNA being a potential "marker" in atypia diagnosis.
    Matched MeSH terms: Electrochemical Techniques*
  11. Lee PK, Woi PM
    Crit Rev Anal Chem, 2020;50(5):393-404.
    PMID: 31335176 DOI: 10.1080/10408347.2019.1642733
    Mixed valence transition metal hexacyanoferrates (MeHCF)-Prussian blue and its analogs receive enormous research interest in the electrochemical sensing field. In recent years, conducting materials such as conducting polymer, carbon nanomaterial, and noble metals have been used to form nanocomposites with MeHCF. The scope of this review offers the reasons behind the preparation of various MeHCF based nanocomposite toward electrochemical detection. We primarily focus on the current progress of the development of MEHCF-based nanocomposites. The synthesis methods for these nanocomposites are also reviewed and discussed.
    Matched MeSH terms: Electrochemical Techniques*
  12. Kamal Eddin FB, Wing Fen Y
    Sensors (Basel), 2020 Feb 14;20(4).
    PMID: 32075167 DOI: 10.3390/s20041039
    Nowadays, several neurological disorders and neurocrine tumours are associated with dopamine (DA) concentrations in various biological fluids. Highly accurate and ultrasensitive detection of DA levels in different biological samples in real-time can change and improve the quality of a patient's life in addition to reducing the treatment cost. Therefore, the design and development of diagnostic tool for in vivo and in vitro monitoring of DA is of considerable clinical and pharmacological importance. In recent decades, a large number of techniques have been established for DA detection, including chromatography coupled to mass spectrometry, spectroscopic approaches, and electrochemical (EC) methods. These methods are effective, but most of them still have some drawbacks such as consuming time, effort, and money. Added to that, sometimes they need complex procedures to obtain good sensitivity and suffer from low selectivity due to interference from other biological species such as uric acid (UA) and ascorbic acid (AA). Advanced materials can offer remarkable opportunities to overcome drawbacks in conventional DA sensors. This review aims to explain challenges related to DA detection using different techniques, and to summarize and highlight recent advancements in materials used and approaches applied for several sensor surface modification for the monitoring of DA. Also, it focuses on the analytical features of the EC and optical-based sensing techniques available.
    Matched MeSH terms: Electrochemical Techniques/methods*; Electrochemical Techniques/trends*
  13. Mat Zaid MH, Che-Engku-Chik CEN, Yusof NA, Abdullah J, Othman SS, Issa R, et al.
    Molecules, 2020 Jul 24;25(15).
    PMID: 32722334 DOI: 10.3390/molecules25153373
    Death from tuberculosis has resulted in an increased need for early detection to prevent a tuberculosis (TB) epidemic, especially in closed and crowded populations. Herein, a sensitive electrochemical DNA biosensor based on functionalized iron oxide with mercaptopropionic acid (MPA-Fe3O4) nanoparticle and nanocellulose crystalline functionalized cetyl trimethyl ammonium bromide (NCC/CTAB) has been fabricated for the detection of Mycobacterium tuberculosis (MTB). In this study, a simple drop cast method was applied to deposit solution of MPA-Fe3O4/NCC/CTAB onto the surface of the screen-printed carbon electrode (SPCE). Then, a specific sequence of MTB DNA probe was immobilized onto a modified SPCE surface by using the 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide (EDC/NHS) coupling mechanism. For better signal amplification and electrochemical response, ruthenium bipyridyl Ru(bpy)32+ was assigned as labels of hybridization followed by the characteristic test using differential pulse voltammetry (DPV). The results of this biosensor enable the detection of target DNA until a concentration as low as 7.96 × 10-13 M with a wide detection range from 1.0 × 10-6 to 1.0 × 10-12 M. In addition, the developed biosensor has shown a differentiation between positive and negative MTB samples in real sampel analysis.
    Matched MeSH terms: Electrochemical Techniques
  14. Guo S, Li Y, Li R, Zhang P, Wang Y, Gopinath SCB, et al.
    Biotechnol Appl Biochem, 2020 May;67(3):383-388.
    PMID: 31876964 DOI: 10.1002/bab.1877
    Abdominal aortic aneurysm (AAA) is a serious, life-threatening vascular disease that presents as an enlarged area of the aorta, which is the main artery that carries blood away from the heart. AAA may occur at any location in the aorta, but it is mainly found in the abdominal region. A ruptured AAA causes serious health issues, including death. Traditional imaging techniques, such as computed tomography angiogram, magnetic resonance imaging, and ultrasound sonography, have been used to identify AAAs. Circulating biomarkers have recently become attractive for diagnosing AAAs due to their cost-effectiveness compared to imaging. Insulin-like growth factor 1 (IGF-1), a secreted hormone vital for human atherosclerotic plaque stability, has been found to be an efficient biomarker for AAA identification. In this report, immunosensing was performed by using an InterDigitated electrode (IDE) sensor to detect circulating levels of IGF-1. The detection limit of IGF-1 was found to be 100 fM with this sensor. Moreover, related protein controls (IGF-2 and IGFBP3) were not detected with the same antibody, indicating selective IGF-1 detection. Thus, immunosensing by using an IDE sensor may help to effectively diagnose AAAs and represents a basic platform for further development.
    Matched MeSH terms: Electrochemical Techniques*
  15. Hui H, Gopinath SCB, Ismail ZH, Chen Y, Pandian K, Velusamy P
    Biotechnol Appl Biochem, 2023 Apr;70(2):581-591.
    PMID: 35765758 DOI: 10.1002/bab.2380
    Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI; however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based diagnosis is an immediate solution, and due to the high correlation of troponin with MI, it has been considered to be a gold-standard biomarker. In the present research, the cardiac biomarker troponin I (cTnI) was detected on an interdigitated electrode sensor with various surface interfaces. To detect cTnI, a capture aptamer-conjugated gold nanoparticle probe and detection antibody probe were utilized and compared through an alternating sandwich pattern. The surface metal oxide morphology of the developed sensor was proven by microscopic assessments. The limit of detection with the aptamer-gold-cTnI-antibody sandwich pattern was 100 aM, while it was 1 fM with antibody-gold-cTnI-aptamer, representing 10-fold differences. Further, the high performance of the sensor was confirmed by selective cTnI determination in serum, exhibiting superior nonfouling. These methods of determination provide options for generating novel assays for diagnosing MI.
    Matched MeSH terms: Electrochemical Techniques/methods
  16. Hasan MR, Pulingam T, Appaturi JN, Zifruddin AN, Teh SJ, Lim TW, et al.
    Anal Biochem, 2018 08 01;554:34-43.
    PMID: 29870692 DOI: 10.1016/j.ab.2018.06.001
    In this study, an amino-modified aptasensor using multi-walled carbon nanotubes (MWCNTs)-deposited ITO electrode was prepared and evaluated for the detection of pathogenic Salmonella bacteria. An amino-modified aptamer (ssDNA) which binds selectively to whole-cell Salmonella was immobilised on the COOH-rich MWCNTs to produce the ssDNA/MWCNT/ITO electrode. The morphology of the MWCNT before and after interaction with the aptamers were observed using scanning electron microscopy (SEM). Cyclic voltammetry and electrochemical impedance spectroscopy techniques were used to investigate the electrochemical properties and conductivity of the aptasensor. The results showed that the impedance measured at the ssDNA/MWCNT/ITO electrode surface increased after exposure to Salmonella cells, which indicated successful binding of Salmonella on the aptamer-functionalised surface. The developed ssDNA/MWCNT/ITO aptasensor was stable and maintained linearity when the scan rate was increased from 10 mV s-1 to 90 mV s-1. The detection limit of the ssDNA/MWCNT/ITO aptasensor, determined from the sensitivity analysis, was found to be 5.5 × 101 cfu mL-1 and 6.7 × 101 cfu mL-1 for S. Enteritidis and S. Typhimurium, respectively. The specificity test demonstrated that Salmonella bound specifically to the ssDNA/MWCNT/ITO aptasensor surface, when compared with non-Salmonella spp. The prepared aptasensor was successfully applied for the detection of Salmonella in food samples.
    Matched MeSH terms: Electrochemical Techniques/methods*; Electrochemical Techniques/statistics & numerical data
  17. Citartan M, Gopinath SC, Tominaga J, Tan SC, Tang TH
    Biosens Bioelectron, 2012 Apr 15;34(1):1-11.
    PMID: 22326894 DOI: 10.1016/j.bios.2012.01.002
    Aptamers are single stranded DNA or RNA oligonucleotides that have high affinity and specificity towards a wide range of target molecules. Aptamers have low molecular weight, amenable to chemical modifications and exhibit stability undeterred by repetitive denaturation and renaturation. Owing to these indispensable advantages, aptamers have been implemented as molecular recognition element as alternative to antibodies in various assays for diagnostics. By amalgamating with a number of methods that can provide information on the aptamer-target complex formation, aptamers have become the elemental tool for numerous biosensor developments. In this review, administration of aptamers in applications involving assays of fluorescence, electrochemistry, nano-label and nano-constructs are discussed. Although detection strategies are different for various aptamer-based assays, the core of the design strategies is similar towards reporting the presence of specific target binding to the corresponding aptamers. It is prognosticated that aptamers will find even broader applications with the development of new methods of transducing aptamer target binding.
    Matched MeSH terms: Electrochemical Techniques/methods*
  18. Citartan M, Tang TH
    Talanta, 2019 Jul 01;199:556-566.
    PMID: 30952298 DOI: 10.1016/j.talanta.2019.02.066
    Aptamers are nucleic acid-based molecular recognition elements that are specific and have high binding affinity against their respective targets. On account of their target recognition capacity, aptamers are widely utilized in a number of applications including diagnostics. This review aims to highlight the recent developments of aptasensors expedient for point-of-care (POC) diagnostics. Significant focus is given on the primary assay formats of aptamers such as fluorescence, electrochemical, surface plasmon resonance (SPR) and colorimetric assays. A potpourri of platforms such as paper-based device, lateral flow assay, portable electrodes, portable SPR and smart phones expedient for point-of-care (POC) diagnostics are discussed. Emphasis is also given on the technicalities and assay configurations associated with the sensors.
    Matched MeSH terms: Electrochemical Techniques
  19. Lin LP, Tan MTT
    Biosens Bioelectron, 2023 Oct 01;237:115492.
    PMID: 37421797 DOI: 10.1016/j.bios.2023.115492
    Lung cancer remains the leading cause of cancer-related death. In addition to chest X-rays and computerised tomography, the detection of cancer biomarkers serves as an emerging diagnostic tool for lung cancer. This review explores biomarkers including the rat sarcoma gene, the tumour protein 53 gene, the epidermal growth factor receptor, the neuron-specific enolase, the cytokeratin-19 fragment 21-1 and carcinoembryonic antigen as potential indicators of lung cancer. Biosensors, which utilise various transduction techniques, present a promising solution for the detection of lung cancer biomarkers. Therefore, this review also explores the working principles and recent implementations of transducers in the detection of lung cancer biomarkers. The transducing techniques explored include optical techniques, electrochemical techniques and mass-based techniques for detecting biomarkers and cancer-related volatile organic compounds. Graphene has outstanding properties in terms of charge transfer, surface area, thermal conductivity and optical characteristics, on top of allowing easy incorporation of other nanomaterials. Exploiting the collective merits of both graphene and biosensor is an emerging trend, as evidenced by the growing number of studies on graphene-based biosensors for the detection of lung cancer biomarkers. This work provides a comprehensive review of these studies, including information on modification schemes, nanomaterials, amplification strategies, real sample applications, and sensor performance. The paper concludes with a discussion of the challenges and future outlook of lung cancer biosensors, including scalable graphene synthesis, multi-biomarker detection, portability, miniaturisation, financial support, and commercialisation.
    Matched MeSH terms: Electrochemical Techniques/methods
  20. Hassan RA, Heng LY, Tan LL
    Sci Rep, 2019 04 23;9(1):6379.
    PMID: 31015498 DOI: 10.1038/s41598-019-42757-y
    A novel disposable electrochemical biosensor based on immobilized calf thymus double-stranded DNA (dsDNA) on the carbon-based screen-printed electrode (SPE) is developed for rapid biorecognition of carrageenan by using methylene blue (MB) redox indicator. The biosensor protocol for the detection of carrageenan is based on the concept of competitive binding of positively charged MB to the negatively charged dsDNA and carrageenan. The decrement in the MB cathodic peak current (ipc) signal as a result of the released MB from the immobilized dsDNA, and attracted to the carrageenan can be monitored via differential pulse voltammetry (DPV). The biosensor showed high sensitivity and selectivity to carrageenan at low concentration without interference from other polyanions such as alginate, gum arabic and starch. Calibration of the biosensor with carrageenan exhibited an excellent linear dependence from 1-10 mg L-1 (R2 = 0.98) with a detection limit of 0.08 mg L-1. The DNA-based carrageenan biosensor showed satisfactory reproducibility with 5.6-6.9% (n = 3) relative standard deviations (RSD), and possessing several advantages such as simplicity, fast and direct application to real sample analysis without any prior extensive sample treatments, particularly for seaweeds and food analyses.
    Matched MeSH terms: Electrochemical Techniques
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links