Displaying publications 181 - 200 of 476 in total

Abstract:
Sort:
  1. Khokhar MF, Nisar M, Noreen A, Khan WR, Hakeem KR
    Environ Sci Pollut Res Int, 2017 Jan;24(3):2827-2839.
    PMID: 27838904 DOI: 10.1007/s11356-016-7907-3
    This study emphasizes on near surface observation of chemically active trace gases such as nitrogen dioxide (NO2) over Islamabad on a regular basis. Absorption spectroscopy using backscattered extraterrestrial light source technique was used to retrieve NO2 differential slant column densities (dSCDs). Mini multi-axis-differential optical absorption spectroscopy (MAX-DOAS) instrument was used to perform ground-based measurements at Institute of Environmental Sciences and Engineering (IESE), National University of Sciences and Technology (NUST) Islamabad, Pakistan. Tropospheric vertical column densities (VCDs) of NO2 were derived from measured dSCDs by using geometric air mass factor approach. A case study was conducted to identify the impact of different materials (glass, tinted glass, and acrylic sheet of various thicknesses used to cover the instrument) on the retrieval of dSCDs. Acrylic sheet of thickness 5 mm was found most viable option for casing material as it exhibited negligible impact in the visible wavelength range. Tropospheric NO2 VCD derived from ground-based mini MAX-DOAS measurements exceeded two times the Pak-NEQS levels and showed a reasonable comparison (r (2) = 0.65, r = 0.81) with satellite observations (root mean square bias of 39 %) over Islamabad, Pakistan.
    Matched MeSH terms: Air Pollutants/analysis*
  2. Newman-Morris G
    Med J Malaysia, 1974 Dec;29(2):107-9.
    PMID: 4282393
    Matched MeSH terms: Air Pollution/prevention & control
  3. Amir Abdullah, M.D., Leman, A.M., Norhidayah, A., Syafiq Syazwan, M.M.
    MyJurnal
    A poor Indoor Air Quality (IAQ) is a crucial problem which produces by the improper maintenance of Mechanical Ventilation and Air Conditioning (MVAC) ducting. A budget constraint intimidates for the practise of monitoring of the MVAC ducting. Thus IAQ measurements were conducted at the room where the air supplied by centralized air conditioning. It has been performed at four different offices that supply by two different Air Handling Unit (AHU). Walkthrough survey was conducted and the area samplings were selected for data collection. This paper examines the result of comparison of air ducting and air quality at academic office building, Universiti Tun Hussein Onn Malaysia (UTHM). The parameters involved were Temperature (°C), Relative Humidity (RH), Carbon Dioxide (CO2) and Carbon Monoxide (CO). Pictures were also captured to demonstrate the real conditions inside the ducting by using Mechanical Robot. Thus, duct cleaning was recommended to be an exceptional platform for the IAQ improvement.
    Matched MeSH terms: Air Conditioning; Air Pollution, Indoor
  4. Ahmad Syazrin Muhammad, Juliana Jalaludin, NurAqilah M. Yusof
    MyJurnal
    Exposure to traffic air pollutant have shown a significant health effect on respiratory systems and decreased in lung function among traffic policemen. The main objective of this study was to determine the relationships between personal exposure levels to PM2.5 and respiratory health among traffic policemen working at Traffic Police Station in Kuala Lumpur and general duty policemen attached to Police Headquarters, Bukit Aman. A cross sectional comparative study was conducted among 50 traffic policemen from Traffic Police Station Kuala Lumpur and 50 general duty policemen from Police Headquarters Bukit Aman as comparative group. A purposive sampling method was used to select the respondents based on inclusive criteria such as age between 25 to 60 years, no history of respiratory disease and working not less than 3 years as traffic policemen. Questionnaire based on ATS (1978) was used to collect information on socio-demographic and respiratory symptoms. Spirometer (Spirolab II Model) was used to perform lung function tests. Personal Air Sampling Pump (Aircheck 52) was used to measure personal exposure level to PM2.5. The mean exposure level of PM2.5 among the traffic policemen was 22.33 ± 8.54μg/m³ compared to only 5.60 ± 4.29μg/m³ for comparative group. There was a significant difference in all lung function parameters between the exposed group and comparative group.From the finding, it shows that there was significant relationship between working duration (years) and lung function parameters among both exposed and comparative group. The result from this research shows that traffic policemen were determined as having lower lung function parameters due to their nature of work and the environment. Also, there was a significant association between exposure to fine particle (PM2.5) and lung function among the exposed group. Finding from this study indicated that exposure to elevated concentration level to traffic related air pollutant was the risk factors in the development of respiratory diseases as shown by the higher prevalence of respiratory symptoms and the reduction in lung function among traffic policemen.
    Matched MeSH terms: Air Pollutants; Air Pollution
  5. Haider K, Khokhar MF, Chishtie F, RazzaqKhan W, Hakeem KR
    Environ Sci Pollut Res Int, 2017 Mar;24(8):7617-7629.
    PMID: 28120226 DOI: 10.1007/s11356-016-8359-5
    Like other developing countries, Pakistan is also facing changes in temperature per decade and other climatic abnormalities like droughts and torrential rains. In order to assess and identify the extent of temperature change over Pakistan, the whole Pakistan was divided into five climatic zones ranging from very cold to hot and dry climates. Similarly, seasons in Pakistan are defined on the basis of monsoon variability as winter, pre-monsoon, monsoon, and post-monsoon. This study primarily focuses on the comparison of surface temperature observations from Pakistan Meteorological Department (PMD) network with PRECIS (Providing Regional Climates for Impacts Studies) model simulations. Results indicate that PRECIS underestimates the temperature in Northern Pakistan and during the winter season. However, there exists a fair agreement between PRECIS output and observed datasets in the lower plain and hot areas of the country. An absolute increase of 0.07 °C is observed in the mean temperature over Pakistan during the time period of 1951-2010. Especially, the increase is more significant (0.7 °C) during the last 14 years (1997-2010). Moreover, SCIAMACHY observations were used to explore the evolution of atmospheric CO2 levels in comparison to temperature over Pakistan. CO2 levels have shown an increasing trend during the first decade of the twenty-first century.
    Matched MeSH terms: Air Pollutants/analysis*
  6. Ali HS, Abdul-Rahim AS, Ribadu MB
    Environ Sci Pollut Res Int, 2017 Jan;24(2):1967-1974.
    PMID: 27798805 DOI: 10.1007/s11356-016-7935-z
    The main aim of this article is to examine empirically the impact of urbanization on carbon dioxide emissions in Singapore from 1970 to 2015. The autoregressive distributed lags (ARDL) approach is applied within the analysis. The main finding reveals a negative and significant impact of urbanization on carbon emissions in Singapore, which means that urban development in Singapore is not a barrier to the improvement of environmental quality. Thus, urbanization enhances environmental quality by reducing carbon emissions in the sample country. The result also highlighted that economic growth has a positive and significant impact on carbon emissions, which suggests that economic growth reduces environmental quality through its direct effect of increasing carbon emissions in the country. Despite the high level of urbanization in Singapore, which shows that 100 % of the populace is living in the urban center, it does not lead to more environmental degradation. Hence, urbanization will not be considered an obstacle when initiating policies that will be used to reduce environmental degradation in the country. Policy makers should consider the country's level of economic growth instead of urbanization when formulating policies to reduce environmental degradation, due to its direct impact on increasing carbon dioxide emissions.
    Matched MeSH terms: Air Pollutants/analysis*
  7. Rabaan AA, Al-Ahmed SH, Al-Malkey M, Alsubki R, Ezzikouri S, Al-Hababi FH, et al.
    Infez Med, 2021 03 01;29(1):10-19.
    PMID: 33664169
    Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has become a pandemic worldwide. On a daily basis the number of deaths associated with COVID-19 is rapidly increasing. The main transmission route of SARS-CoV-2 is through the air (airborne transmission). This review details the airborne transmission of SARS-CoV-2, the aerodynamics, and different modes of transmission (e.g. droplets, droplet nuclei, and aerosol particles). SARS-CoV-2 can be transmitted by an infected person during activities such as expiration, coughing, sneezing, and talking. During such activities and some medical procedures, aerosols and droplets contaminated with SARS-CoV-2 particles are formed. Depending on their sizes and the environmental conditions, such particles stay viable in the air for varying time periods and can cause infection in a susceptible host. Very few studies have been conducted to establish the mechanism or the aerodynamics of virus-loaded particles and droplets in causing infection. In this review we discuss the various forms in which SARS-CoV-2 virus particles can be transmitted in air and cause infections.
    Matched MeSH terms: Air Microbiology*
  8. MOHAMAD FIRDAUS ISMAIL, MUHAMMAD FAIS FADZIL, NORHAYATI MOHD TAHIR, NORHAYATI MOHD TAHIR, MOHD TALIB LATIF, NOORLIN MOHAMAD
    MyJurnal
    Fine particulate matter (aerodynamic diameter ≤2.5 μm) (PM2.5) has become a major concern because it can adsorb chemicals e.g. polycyclic aromatic hydrocarbons (PAHs) onto its surface. Although PAHs are priority pollutants that can cause adverse health effect, there is still limited information concerning indoor exposures to PAHs in Malaysia. This study aimed to characterise the distribution of PAHs bounded to PM2.5in primary school environments. Indoor and outdoor PM2.5 were collected between May and July 2017 using low volume samplers (LVS) at three public primary schools in the Federal Territory of Kuala Lumpur. PAHs were extracted by ultrasonic extraction with Dichloromethane: n-Hexane (1:1, v/v) as the extraction solvent and analysed using gas chromatography coupled with mass spectrometer (GC-MS). Based on the results, the average total concentration of PAHs (∑PAHs) ranged from 3.8 to 10.1 ng m-3and 1.6 to 8.0 ng m-3for outdoors and indoors, respectively. PAHs in PM2.5samples indicated the potential contribution of combustion at high temperature and indoor sources and the infiltration of outdoor PAHs were the important sources for outdoor and indoor, respectively. In addition, the diagnostic ratio analysis showed that vehicular emissions were the most predominant sources of PAHs in school environments.
    Matched MeSH terms: Air Pollutants; Air Pollution, Indoor
  9. Abidin SZ, Ho TM
    Asian Pac J Trop Biomed, 2012 Feb;2(2):156-8.
    PMID: 23569888 DOI: 10.1016/S2221-1691(11)60212-8
    To investigate the short and long term efficacy of a commercial air ionizer in killing Dermatophagoides pteronyssinus (D. pteronyssinus) and Dermatophagoides farinae (D. farinae) mites.
    Matched MeSH terms: Air Ionization*
  10. Mehmannavaz T, Ismail M, Radin Sumadi S, Rafique Bhutta MA, Samadi M, Sajjadi SM
    ScientificWorldJournal, 2014;2014:461241.
    PMID: 24696646 DOI: 10.1155/2014/461241
    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern.
    Matched MeSH terms: Air/analysis*
  11. Soyiri IN, Reidpath DD, Sarran C
    Chron Respir Dis, 2013 May;10(2):85-94.
    PMID: 23620439 DOI: 10.1177/1479972313482847
    Health forecasting can improve health service provision and individual patient outcomes. Environmental factors are known to impact chronic respiratory conditions such as asthma, but little is known about the extent to which these factors can be used for forecasting. Using weather, air quality and hospital asthma admissions, in London (2005-2006), two related negative binomial models were developed and compared with a naive seasonal model. In the first approach, predictive forecasting models were fitted with 7-day averages of each potential predictor, and then a subsequent multivariable model is constructed. In the second strategy, an exhaustive search of the best fitting models between possible combinations of lags (0-14 days) of all the environmental effects on asthma admission was conducted. Three models were considered: a base model (seasonal effects), contrasted with a 7-day average model and a selected lags model (weather and air quality effects). Season is the best predictor of asthma admissions. The 7-day average and seasonal models were trivial to implement. The selected lags model was computationally intensive, but of no real value over much more easily implemented models. Seasonal factors can predict daily hospital asthma admissions in London, and there is a little evidence that additional weather and air quality information would add to forecast accuracy.
    Matched MeSH terms: Air Pollution/statistics & numerical data*
  12. Bhatia S, Wong CT, Abdullah AZ
    J Hazard Mater, 2009 May 30;164(2-3):1110-7.
    PMID: 18976860 DOI: 10.1016/j.jhazmat.2008.09.040
    The low concentration and high flow rate of air-borne butyl acetate (BA) could be effectively removed using combined adsorption-catalytic oxidation system. Ag-Y (Si/Al=80) dual-function adsorbent was investigated for the adsorption step of 1000 ppm of butyl acetate at gas hourly space velocity of 13,000 h(-1) at ambient temperature under dry and humid feeds. A central composite design (CCD) coupled with response surface methodology (RSM) was employed to obtain the optimum process conditions and the interactions between process variables were demonstrated and elucidated. Humidity and increasing organic concentration shortened the adsorption service time. The effect of moisture was more pronounced at low BA concentration. The interactions between the BA concentration and humidity were statistically significant at 95% confidence level. The optimum conditions were found to be at 4500 ppm of BA with 37 min saturation time to give 58 mg BA/g as adsorption capacity. The simulated data fitted the experimental data satisfactorily. The simulated data also correctly demonstrated the overall behaviors of the adsorption process.
    Matched MeSH terms: Air Pollutants/isolation & purification*
  13. Mujeebu MA, Abdullah MZ, Bakar MZ, Mohamad AA, Muhad RM, Abdullah MK
    J Environ Manage, 2009 Jun;90(8):2287-312.
    PMID: 19299066 DOI: 10.1016/j.jenvman.2008.10.009
    The rapid advances in technology and improved living standard of the society necessitate abundant use of fossil fuels which poses two major challenges to any nation. One is fast depletion of fossil fuel resources; the other is environmental pollution. The porous medium combustion (PMC) has proved to be one of the technically and economically feasible options to tackle the aforesaid problems to a remarkable extent. PMC has interesting advantages compared with free flame combustion due to the higher burning rates, the increased power dynamic range, the extension of the lean flammability limits, and the low emissions of pollutants. This article provides a comprehensive picture of the global scenario of research and developments in PMC and its applications that enable a researcher to decide the direction of further investigation. The works published so far in this area are reviewed, classified according to their objectives and presented in an organized manner with general conclusions. A separate section is devoted for the numerical modeling of PMC.
    Matched MeSH terms: Air Pollution/prevention & control
  14. Abushammala MF, Noor Ezlin Ahmad Basri, Basri H, Ahmed Hussein El-Shafie, Kadhum AA
    Waste Manag Res, 2011 Aug;29(8):863-73.
    PMID: 20858637 DOI: 10.1177/0734242X10382064
    The decomposition of municipal solid waste (MSW) in landfills under anaerobic conditions produces landfill gas (LFG) containing approximately 50-60% methane (CH(4)) and 30-40% carbon dioxide (CO(2)) by volume. CH(4) has a global warming potential 21 times greater than CO(2); thus, it poses a serious environmental problem. As landfills are the main method for waste disposal in Malaysia, the major aim of this study was to estimate the total CH(4) emissions from landfills in all Malaysian regions and states for the year 2009 using the IPCC, 1996 first-order decay (FOD) model focusing on clean development mechanism (CDM) project applications to initiate emission reductions. Furthermore, the authors attempted to assess, in quantitative terms, the amount of CH(4) that would be emitted from landfills in the period from 1981-2024 using the IPCC 2006 FOD model. The total CH(4) emission using the IPCC 1996 model was estimated to be 318.8 Gg in 2009. The Northern region had the highest CH(4) emission inventory, with 128.8 Gg, whereas the Borneo region had the lowest, with 24.2 Gg. It was estimated that Pulau Penang state produced the highest CH(4) emission, 77.6 Gg, followed by the remaining states with emission values ranging from 38.5 to 1.5 Gg. Based on the IPCC 1996 FOD model, the total Malaysian CH( 4) emission was forecast to be 397.7 Gg by 2020. The IPCC 2006 FOD model estimated a 201 Gg CH(4) emission in 2009, and estimates ranged from 98 Gg in 1981 to 263 Gg in 2024.
    Matched MeSH terms: Air Pollutants/analysis*
  15. Azmi SZ, Latif MT, Ismail AS, Juneng L, Jemain AA
    Air Qual Atmos Health, 2010 Mar;3(1):53-64.
    PMID: 20376168
    Over the last decades, the development of the Klang Valley (Malaysia), as an urban commercial and industrial area, has elevated the risk of atmospheric pollutions. There are several significant sources of air pollutants which vary depending on the background of the location they originate from. The aim of this study is to determine the trend and status of air quality and their correlation with the meteorological factors at different air quality monitoring stations in the Klang Valley. The data of five major air pollutants (PM(10), CO, SO(2), O(3), NO(2)) were recorded at the Alam Sekitar Sdn Bhd (ASMA) monitoring stations in the Klang Valley, namely Petaling Jaya (S1), Shah Alam (S2) and Gombak (S3). The data from these three stations were compared with the data recorded at Jerantut, Pahang (B), a background station established by the Malaysian Department of Environment. Results show that the concentrations of CO, NO(2) and SO(2) are higher at Petaling Jaya (S1) which is due to influence of heavy traffic. The concentrations of PM(10) and O(3,) however, are predominantly related to regional tropical factors, such as the influence of biomass burning and of ultra violet radiation from sunlight. They can, though, also be influenced by local sources. There are relatively stronger inter-pollutant correlations at the stations of Gombak and Shah Alam, and the results also suggest that heavy traffic flow induces high concentrations of PM(10), CO, NO(2) and SO(2) at the three sampling stations. Additionally, meteorological factors, particularly the ambient temperature and wind speed, may influence the concentration of PM(10) in the atmosphere.
    Matched MeSH terms: Air Pollutants; Air Pollution
  16. Yau YH, Chew BT
    Indoor Air, 2009 Dec;19(6):500-10.
    PMID: 19719535 DOI: 10.1111/j.1600-0668.2009.00617.x
    This article presents findings of the thermal comfort study in hospitals. A field survey was conducted to investigate the temperature range for thermal comfort in hospitals in the tropics. Thermal acceptability assessment was conducted to examine whether the hospitals in the tropics met the ASHRAE Standard-55 80% acceptability criteria. A total of 114 occupants in four hospitals were involved in the study. The results of the field study revealed that only 44% of the examined locations met the comfort criteria specified in ASHRAE Standard 55. The survey also examined the predicted percentage of dissatisfied in the hospitals. The results showed that 49% of the occupants were satisfied with the thermal environments in the hospitals. The field survey analysis revealed that the neutral temperature for Malaysian hospitals was 26.4 degrees C. The comfort temperature range that satisfied 90% of the occupants in the space was in the range of 25.3-28.2 degrees C. The results from the field study suggested that a higher comfort temperature was required for Malaysians in hospital environments compared with the temperature criteria specified in ASHRAE Standard (2003). In addition, the significant deviation between actual mean vote and predicted mean vote (PMV) strongly implied that PMV could not be applied without errors in hospitals in the tropics.
    Matched MeSH terms: Air Conditioning/standards*
  17. Omar NY, Mon TC, Rahman NA, Abas MR
    Sci Total Environ, 2006 Oct 1;369(1-3):76-81.
    PMID: 16766020
    The concentrations and distributions of particle bound polycyclic aromatic hydrocarbons (PAHs) collected over a 10 month period in ambient environment, at street levels as well as during a hazy episode are reported. Ambient and street level distributions of PAHs were similar and their occurrence was attributed to vehicular emissions. However, in haze particles, a different pattern of PAHs was observed, characterized by relatively low levels of benzo[a]pyrene (BaP) and high levels of benzofluoranthenes (BFs). The BaP equivalency results showed that the potential health risk associated with haze smoke particles was 4 times higher than that of street level particles whereas the lowest health risk was associated with ambient atmospheric particles.
    Matched MeSH terms: Air Pollutants/analysis*
  18. Chang KF, Fang GC, Chen JC, Wu YS
    Environ Pollut, 2006 Aug;142(3):388-96.
    PMID: 16343719
    Polycyclic aromatic hydrocarbons (PAHs) are present in both gaseous and particulate phases. These compounds are considered to be atmospheric contaminants and are human carcinogens. Many studies have monitored atmospheric particulate and gaseous phases of PAH in Asia over the past 5 years. This work compares and discusses different sample collection, pretreatment and analytical methods. The main PAH sources are traffic exhausts (AcPy, FL, Flu, PA, Pyr, CHR, BeP) and industrial emissions (BaP, BaA, PER, BeP, COR, CYC). PAH concentrations are highest in areas of traffic, followed by the urban sites, and lowest in rural sites. Meteorological conditions, such as temperature, wind speed and humidity, strongly affect PAH concentrations at all sampling sites. This work elucidates the characteristics, sources and distribution, and the healthy impacts of atmospheric PAH species in Asia.
    Matched MeSH terms: Air Pollutants/analysis*
  19. Abdullah AZ, Bakar MZ, Bhatia S
    J Hazard Mater, 2006 Feb 28;129(1-3):39-49.
    PMID: 16310938
    The paper reports on the performance of chromium or/and copper supported on H-ZSM-5(Si/Al = 240) modified with silicon tetrachloride (Cr1.5/SiCl4-Z, Cu1.5/SiCl4-Z and Cr1.0Cu0.5/SiCl4-Z) as catalysts in the combustion of chlorinated VOCs (Cl-VOCs). A reactor operated at a gas hourly space velocity (GHSV) of 32,000 h(-1), a temperature between 100 and 500 degrees C with 2500 ppm of dichloromethane (DCM), trichloromethane (TCM) and trichloroethylene (TCE) is used for activity studies. The deactivation study is conducted at a GHSV of 3800 h(-1), at 400 degrees C for up to 12 h with a feed concentration of 35,000 ppm. Treatment with silicon tetrachloride improves the chemical resistance of H-ZSM-5 against hydrogen chloride. TCM is more reactive compared to DCM but it produces more by-products due to its high chlorine content. The stabilization of TCE is attributed to resonance effects. Water vapor increases the carbon dioxide yield through its role as hydrolysis agent forming reactive carbocations and acting as hydrogen-supplying agent to suppress chlorine-transfer reactions. The deactivation of Cr1.0Cu0.5/SiCl4-Z is mainly due to the chlorination of its metal species, especially with higher Cl/H feed. Coking is limited, particularly with DCM and TCM. In accordance with the Mars-van Krevelen model, the weakening of overall metal reducibility due to chlorination leads to a loss of catalytic activity.
    Matched MeSH terms: Air Pollutants, Occupational/chemistry*
  20. Abas MR, Omar NY, Maah MJ
    J Environ Sci (China), 2004;16(5):751-4.
    PMID: 15559805
    PM10 airborne particles and soot deposit collected after a fire incident at a chemical store were analyzed in order to determine the concentrations of polycyclic aromatic hydrocarbons (PAHs). The samples were extracted with 1:1 hexane-dichloromethane by ultrasonic agitation. The extracts were then subjected to gas chromatography-mass spectrometric (GC-MS) analysis. The total PAHs concentrations in airborne particles and soot deposit were found to be 3.27 +/- 1.55 ng/m3 and 12.81 +/- 24.37 microg/g, respectively. Based on the molecular distributions of PAHs and the interpretation of their diagnostic ratios such as PHEN/(PHEN + ANTH), FLT/(FLT + PYR) and BeP/(BeP + BaP), PAHs in both airborne particles and soot deposit may be inferred to be from the same source. The difference in the value of IP/(IP + BgP) for these samples indicated that benzo[g, h, i] perylene and coronene tend to be attached to finer particles and reside in the air for longer periods. Comparison between the molecular distributions of PAHs and their diagnostic ratios observed in the current study with those reported for urban atmospheric and roadside soil particles revealed that they are of different sources.
    Matched MeSH terms: Air Pollutants/analysis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links