Materials and Methods: Freshly extracted mandibular teeth with sample size of thirty were carefully chosen and instrumented using the 2Shape and WOG rotary files. Preoperative and postinstrumentation cone-beam computed tomographic scans were done to accomplish mesial and distal dentin walls' measurements and volume of removed dentin calculations, apical transportation, and centering ratio. Statistical analysis was performed and confirmed by independent t-test. Statistical significance was set at 5%.
Results: When shaping ability of 2Shape and WOG was evaluated, it was reported that there was no statistically significant differences noted among the groups in relation to the total volume of removed dentin, apical transportation, and centering ratio.
Conclusion: It can be concluded that 2Shape and WOG preserved the original canal anatomy well and did not eliminate excess dentin during shaping and cleaning. Rotary nickel-titanium files which work on the principle of rotary movement attained an outcome analogous to that of the rotary files working on reciprocating motion in relation to alteration in angle.
DESIGN: A digitally derived 3-dimensional maxillary model incorporating the palatal defect was generated from the patient's existing cone beam computerized tomography data and compared with the scanned cast from the conventional impression for linear dimensions, area, and volume. The digitally derived cast was 3-dimensionally printed and the obturator fabricated using traditional techniques. Similarly, an obturator was fabricated from the conventional cast and the fit of both final obturator bulbs were compared in vivo.
RESULTS: The digitally derived model produced more accurate volumes and surface areas within the defect. The defect margins and peripheries were overestimated which was reflected clinically.
CONCLUSION: The digitally derived model provided advantages in the fabrication of the palatal obturator; however, further clinical research is required to refine consistency.
METHODS: In 24 participants, 140-200 g of force was applied for mandibular canine retraction. Three MOPs were made according to the scheduled intervals of the 3 different groups: group 1 (MOP 4 weeks), group 2 (MOP 8 weeks), and group 3 (MOP 12 weeks) directly at the mandibular buccal cortical bone of extracted first premolars sites. Cone-beam computed tomography scans were obtained at the 12th week after MOP application. Computed tomography Analyzer software (version 1.11.0.0; Skyscan, Kontich, Belgium) was used to compute the trabecular alveolar BV/TV ratio.
RESULTS: A significant difference was observed in the rate of canine movement between control and MOP. Paired t test analysis showed a significant difference (P = 0.001) in the mean BV/TV ratio between control and MOP sides in all the frequency intervals groups. However, the difference was significant only in group 1 (P = 0.014). A strong negative correlation (r = -0.86) was observed between the rate of canine tooth movement and the BV/TV ratio at the MOP side for group 1 and all frequency intervals together (r = -0.42).
CONCLUSIONS: The rate of orthodontic tooth movement can be accelerated by the MOP technique with frequently repeated MOPs throughout the treatment.
MATERIALS AND METHODS: Oral biopsies (n = 44) were scanned using the swept source OCT (SSOCT) and grouped by pathology diagnosis to benign, dysplasia or carcinoma. Two trained and calibrated assessors scored on the five OCT variables: thickness of keratin layer (KL), epithelial layer (EL), homogeneity of lamina propria (LP), basement membrane integrity (BMI), and the degree of reflection of the epithelial layer (Ep Re). Chi-square tests and Fischer's exact method were used to compare the data.
RESULTS: The OCT images showed breached BM status in all the OSCC samples (100%). Epithelial reflection was noted to be hyper-reflective in all the OSCC and oral dysplasia samples (100%). An increase in KL in 66.67% of the OSCC and 100% of the oral dysplasia samples was found. EL was increased in all the OSCC samples (100%) and 85.72% of the oral dysplasias. Kappa values showed that there was very good agreement (over 0.7) when scoring individual parameters between the two assessors.
CONCLUSION: The study showed that the BM status was a key parameter in the detection of SCC and for differentiating SCC from oral dysplasia or benign disorders.
CLINICAL RELEVANCE: OCT is a non-invasive and non-radioactive adjunct diagnostic tool that can provide immediate results on the structure of oral mucosa. The BM status measured ex vivo was a key parameter in the detection of SCC and for differentiating SCC from oral dysplasia or benign disorders.
METHODOLOGY: A literature search was performed in Elsevier's Scopus database to locate all the publications of the International Endodontic Journal. Various bibliometric software packages including the open-source visualization software Gephi and Biblioshiny (version 2.0) were employed for data visualization and analysis.
RESULTS: A total of 3739 records with citation and bibliographic details were selected and retrieved to allow a bibliometric analysis to be performed. The bibliometric analysis indicates that the IEJ has grown both in terms of productivity and influence. Over time, the journal has been associated with an increase in the number of manuscripts published and the citations they have attracted, but with minor downward fluctuations in citations in the last few years. Bibliographic coupling of the IEJ articles revealed that the major research themes published in the journal include 'endodontics', 'root canal treatment', 'calcium hydroxide', 'apical periodontitis', 'mineral trioxide aggregate', 'microbiology', 'cyclic fatigue', 'cone-beam computed tomography' and 'micro-computed tomography'. Authors affiliated to institutions in the UK were the major contributors to the journal and were linked with other countries such as Brazil, USA and Malaysia. The largest number of publications were from the University of São Paulo, Brazil.
CONCLUSION: The IEJ is one of the leading journals in Endodontology and has been providing a platform for innovative research and clinical reports for more than 50 years. Publications have been associated with a wide range of authors, institutions and countries around the world.
METHODS: This study included 344 patients from the Korean Obstructive Lung Disease (KOLD) cohort. External validation was performed on a cohort of 112 patients. In total, 525 chest CT-based radiomics features were semi-automatically extracted. The five most useful features for survival prediction were selected by least absolute shrinkage and selection operation (LASSO) Cox regression analysis and used to generate a RS. The ability of the RS for classifying COPD patients into high or low mortality risk groups was evaluated with the Kaplan-Meier survival analysis and Cox proportional hazards regression analysis.
RESULTS: The five features remaining after the LASSO analysis were %LAA-950, AWT_Pi10_6th, AWT_Pi10_heterogeneity, %WA_heterogeneity, and VA18mm. The RS demonstrated a C-index of 0.774 in the discovery group and 0.805 in the validation group. Patients with a RS greater than 1.053 were classified into the high-risk group and demonstrated worse overall survival than those in the low-risk group in both the discovery (log-rank test, < 0.001; hazard ratio [HR], 5.265) and validation groups (log-rank test, < 0.001; HR, 5.223). For both groups, RS was significantly associated with overall survival after adjustments for patient age and body mass index.
CONCLUSIONS: A radiomics approach for survival prediction and risk stratification in COPD patients is feasible, and the constructed radiomics model demonstrated acceptable performance. The RS derived from chest CT data of COPD patients was able to effectively identify those at increased risk of mortality.
KEY POINTS: • A total of 525 chest CT-based radiomics features were extracted and the five radiomics features of %LAA-950, AWT_Pi10_6th, AWT_Pi10_heterogeneity, %WA_heterogeneity, and VA18mm were selected to generate a radiomics model. • A radiomics model for predicting survival of COPD patients demonstrated reliable performance with a C-index of 0.774 in the discovery group and 0.805 in the validation group. • Radiomics approach was able to effectively identify COPD patients with an increased risk of mortality, and patients assigned to the high-risk group demonstrated worse overall survival in both the discovery and validation groups.