METHODS: Focus group interviews were conducted to determine the construct of the questionnaire. Content and face validity were assessed by a panel of experts. A pilot study was conducted to validate the Sexual Dysfunction in Asian Men with Diabetes (SAD-MEN) questionnaire in English and Malay. The International Index of Erectile Function-5 (IIEF-5) was used for comparison. Construct validity was assessed using exploratory factor analysis, reliability was determined using Cronbach's α (> 0.700), and test-retest reliability using Spearman's rank correlation coefficient.
RESULTS: The SAD-MEN questionnaire yielded moderate face and content validity, with high reliability as shown by Cronbach's α values of 0.949 for sexual performance and 0.775 for sexual desire for the English version. The Malay language questionnaire had a Cronbach's α value of 0.945 for sexual performance and 0.750 for sexual desire. Test-retest reliability using Spearman's test gave correlation coefficients of r = 0.853, P = 0.000 for the English language questionnaire and r = 0.908, P = 0.000 for the Malay language questionnaire.
CONCLUSION: The SAD-MEN questionnaire is a valid and reliable tool by which to assess sexual dysfunction in English- and Malay-speaking Malaysian and South East Asian men with diabetes.
MATERIALS AND METHODS: This was a cross sectional study with 64 arms from 32 patients (34 neuropathic, 30 nonneuropathic). Diagnosis was confirmed by nerve conduction study and electromyography. The ulnar nerves were evaluated with 15MHz small footprint linear array transducer. The ulnar nerve CSA was measured at three levels with arm extended: at medial epicondyle (ME), 5cm proximal and 5cm distal to ME. Results from the neuropathic and nonneuropathic arms were compared. Independent T-tests and Pearson correlation tests were used. P value of less than 0.05 was considered significant.
RESULTS: Mean CSA values for the UN at levels 5cm proximal to ME, ME and 5cm distal to ME were 0.055, 0.109, 0.045 cm(2) respectively in the neuropathic group and 0.049, 0.075, 0.042 cm2 respectively in the non-neuropathic group. The CSA of the UN at the ME level was significantly larger in the neuropathic group, with p value of 0.005. However, there was no statistical difference between the groups at 5cm proximal and distal to the ME, with p values of 0.10 and 0.35 respectively.
CONCLUSION: There is significant difference in CSA values of the UN at ME between the neuropathic and non-neuropathic groups with mean CSA value above the predetermined 0.10cm(2) cut-off point. High-resolution ultrasonography is therefore useful to diagnose and follow up cases of elbow UNN.