Displaying publications 21 - 40 of 97 in total

Abstract:
Sort:
  1. Ying CK, Kandaiya S
    J Radiol Prot, 2010 Sep;30(3):585-96.
    PMID: 20826892 DOI: 10.1088/0952-4746/30/3/012
    Interventional cardiology (IC) procedures are known to give high radiation doses to patients and cardiologists as they involve long fluoroscopy times and several cine runs. Patients' dose measurements were carried out at the cardiology department in a local hospital in Penang, Malaysia, using Gafchromic XR-RV2 films. The dosimetric properties of the Gafchromic film were first characterised. The film was energy and dose rate independent but dose dependent for the clinically used values. The film had reproducibility within ± 3% when irradiated on three different days and hence the same XR-RV2 dose-response calibration curve can be used to obtain patient entrance skin dose on different days. The increase in the response of the film post-irradiation was less than 4% over a period of 35 days. For patient dose measurements, the films were placed on the table underneath the patient for an under-couch tube position. This study included a total of 44 patients. Values of 35-2442 mGy for peak skin dose (PSD) and 10.9-344.4 Gy cm(2) for dose-area product (DAP) were obtained. DAP was found to be a poor indicator of PSD for PTCA procedures but there was a better correlation (R(2) = 0.7344) for CA + PTCA procedures. The highest PSD value in this study exceeded the threshold dose value of 2 Gy for early transient skin injury recommended by the Food and Drug Administration.
    Matched MeSH terms: Coronary Angiography*
  2. Sim KH, Ong TK, Chin SP, Wong M
    Indian Heart J, 2007 Mar-Apr;59(2 Suppl B):B25-32.
    PMID: 19153433
    Matched MeSH terms: Coronary Angiography/methods*
  3. Chee KH, Siaw FS, Chan CG, Chong WP, Imran ZA, Haizal HK, et al.
    Int J Clin Pract, 2005 Jun;59(6):628-31.
    PMID: 15924588
    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
    Matched MeSH terms: Coronary Angiography/methods
  4. Moosavi Tayebi R, Wirza R, Sulaiman PS, Dimon MZ, Khalid F, Al-Surmi A, et al.
    J Cardiothorac Surg, 2015;10:58.
    PMID: 25896185 DOI: 10.1186/s13019-015-0249-2
    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography.
    Matched MeSH terms: Coronary Angiography/methods*
  5. Tajfard M, Tavakoly Sany SB, Avan A, Latiff LA, Rahimi HR, Moohebati M, et al.
    J Cell Physiol, 2019 07;234(7):10289-10299.
    PMID: 30548615 DOI: 10.1002/jcp.27945
    Serum high-sensitivity C-reactive protein (hs-CRP) is predictive of coronary artery disease (CAD). The aim of this study was to examine the possible association of hs-CRP with presence and severity of CAD and traditional CAD risk factors. This case-control study was carried out on 2,346 individuals from September 2011 to May 2013. Of these 1,187 had evidence of coronary disease, and were subject to coronary angiography, and the remainder were healthy controls (n = 1,159). Characteristics were determined using standard laboratory techniques and serum Hs-CRP levels were estimated using enzyme-linked immunosorbent assay (ELISA) kits, and severity of CAD was assessed according to the score of obstruction in coronary artery. Serum hs-CRP levels were higher in those with severe coronary disease, who had stenosis ≥ 50% stenosis of at least one coronary artery (all p 
    Matched MeSH terms: Coronary Angiography/methods
  6. Lim KC, Yap LB, Amin AN
    Med J Malaysia, 2020 09;75(5):472-478.
    PMID: 32918412
    INTRODUCTION: Stent thrombosis (ST) is an uncommon, but significant complication following angioplasty. We aimed to examine the predictors, clinical outcomes and mechanism of definite ST cases among patients who underwent percutaneous coronary intervention (PCI).

    METHODS: This was a retrospective observational registry of 14,935 patients from the year 2011 till 2015. Clinical characteristics, clinical outcome and intracoronary imaging data were recorded in all the patients. The SPSS Statistic version 24 was used for statistical analysis. The Cox regression hazard model was used to report calculate the hazard ratio (HR) with a 95% confidence interval (95%CI). Independent predictors of ST were identified by univariate logistic regression analysis. Variables that showed a statistically significant effect in univariate analyses were entered in a multivariate Cox proportional hazards model. A p-value<0.05 was regarded as significant.

    RESULTS: The incidence of definite ST was 0.25% (37 out of 14935 patients). 75% of ST group patients presented with ST elevation myocardial infarction (75% vs. 19.8%, p<0.01). There was higher mortality among patients with ST when compared to the group without ST (Hazard Ratio, HR=10.69, 95%CI: 1.13, 100). Two independent predictors of ST were 1) previous history of acute myocardial infarction (HR=2.36, 95%CI: 1.19, 4.70) and 2) PCI in the context of acute coronary syndrome when compared to elective PCI (HR=37, 95%CI: 15.7, 91.5). Examination of 19 ST cases with intracoronary imaging identified nine cases (47%) of underexpanded stents and five cases (26%) of malopposition of stents.

    CONCLUSIONS: ST is associated with high mortality. PCI in acute coronary syndrome setting and a previous history of acute myocardial infarction were significant predictors for ST. Intracoronary imaging identified stent underexpansion and malopposition as common reasons for ST. In cases where the risk of ST is high, the use of intracoronary imaging guided PCI is recommended.

    Matched MeSH terms: Coronary Angiography/adverse effects*
  7. Rosenberg M, Waliszewski M, Krackhardt F, Chin K, Wan Ahmad WA, Caramanno G, et al.
    J Interv Cardiol, 2019;2019:6548696.
    PMID: 31772539 DOI: 10.1155/2019/6548696
    Objectives: We analyzed the efficacy of drug coated balloons (DCB) as a stand-alone-therapy in de novo lesions of large coronary arteries. DCBs seem to be an attractive alternative for the stent-free interventional treatment of de novo coronary artery disease (CAD). However, data regarding a DCB-only approach in de novo CAD are currently limited to vessels of small caliber.

    Methods: By means of propensity score (PS) matching 234 individuals with de novo CAD were identified with similar demographic characteristics. This patient population was stratified in a 1:1 fashion according to a reference vessel diameter cut-off of 2.75 mm in small and large vessel disease. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 9 months.

    Results: Patients with small vessel disease had an average reference diameter of 2.45 ± 0.23 mm, while the large vessel group averaged 3.16 ± 0.27 mm. Regarding 9-month major adverse cardiac event (MACE), 5.7% of the patients with small and 6.1% of the patients with large vessels had MACE (p=0.903). Analysis of the individual MACE components revealed a TLR rate of 3.8% in small and 1.0% in large vessels (p=0.200). Of note, no thrombotic events in the DCB treated coronary segments occurred in either group during the 9-month follow-up.

    Conclusions: Our data demonstrate for the first time that DCB-only PCI of de novo lesions in large coronary arteries (>2.75 mm) is safe and as effective. Interventional treatment for CAD without permanent or temporary scaffolding, demonstrated a similar efficacy for large and small vessels.

    Matched MeSH terms: Coronary Angiography/methods
  8. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Coronary Angiography/methods
  9. Xie CB, Chan MY, Teo SG, Low AF, Tan HC, Lee CH
    Singapore Med J, 2011 Nov;52(11):835-9.
    PMID: 22173254
    There is a paucity of data on acute myocardial infarction (AMI) in young Asian women and of comparative data among various ethnic groups with respect to risk factor profile and clinical outcomes. We present a comprehensive overview of the clinical characteristics of young Asian women with AMI and a comparative analysis among Chinese, Malay and Indian women in a multi-ethnic Asian country.
    Matched MeSH terms: Coronary Angiography/methods
  10. Ong TK, Chin SP, Liew CK, Chan WL, Seyfarth MT, Liew HB, et al.
    Am Heart J, 2006 Jun;151(6):1323.e1-6.
    PMID: 16781246
    The new 64-row multidetector computed tomography (CT)-assisted angiography can now detect coronary artery disease with shorter breath-hold time and at faster heart rates for symptomatic patients. We aim to determine if the 64-row scanner can also overcome limitations due to mild to moderate calcification.
    Matched MeSH terms: Coronary Angiography/methods*
  11. Abdullah KA, McEntee MF, Reed W, Kench PL
    J Med Radiat Sci, 2020 Sep;67(3):170-176.
    PMID: 32219989 DOI: 10.1002/jmrs.387
    INTRODUCTION: 3D-printed imaging phantoms are now increasingly available and used for computed tomography (CT) dose optimisation study and image quality analysis. The aim of this study was to evaluate the integrated 3D-printed cardiac insert phantom when evaluating iterative reconstruction (IR) algorithm in coronary CT angiography (CCTA) protocols.

    METHODS: The 3D-printed cardiac insert phantom was positioned into a chest phantom and scanned with a 16-slice CT scanner. Acquisitions were performed with CCTA protocols using 120 kVp at four different tube currents, 300, 200, 100 and 50 mA (protocols A, B, C and D, respectively). The image data sets were reconstructed with a filtered back projection (FBP) and three different IR algorithm strengths. The image quality metrics of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were calculated for each protocol.

    RESULTS: Decrease in dose levels has significantly increased the image noise, compared to FBP of protocol A (P 

    Matched MeSH terms: Coronary Angiography*
  12. Sakai K, Storozhenko T, Mizukami T, Ohashi H, Bouisset F, Tajima A, et al.
    Catheter Cardiovasc Interv, 2024 May;103(6):885-896.
    PMID: 38566527 DOI: 10.1002/ccd.31020
    BACKGROUND: Two invasive methods are available to estimate microvascular resistance: bolus and continuous thermodilution. Comparative studies have revealed a lack of concordance between measurements of microvascular resistance obtained through these techniques.

    AIMS: This study aimed to examine the influence of vessel volume on bolus thermodilution measurements.

    METHODS: We prospectively included patients with angina with non-obstructive coronary arteries (ANOCA) undergoing bolus and continuous thermodilution assessments. All patients underwent coronary CT angiography to extract vessel volume. Coronary microvascular dysfunction was defined as coronary flow reserve (CFR) 

    Matched MeSH terms: Coronary Angiography*
  13. Sabarudin A, Sun Z, Ng KH
    Radiat Prot Dosimetry, 2013;154(3):301-7.
    PMID: 22972797 DOI: 10.1093/rpd/ncs243
    A retrospective analysis was performed in patients undergoing prospective ECG-triggered coronary computed tomography (CT) angiography (CCTA) with the single-source 64-slice CT (SSCT), dual-source 64-slice CT (DSCT), dual-source 128-slice CT and 320-slice CT with the aim of comparing the radiation dose associated with different CT generations. A total of 164 patients undergoing prospective ECG-triggered CCTA with different types of CT scanners were studied with the mean effective doses estimated at 6.8 ± 3.2, 4.2 ± 1.9, 4.1±0.6 and 3.8 ± 1.4 mSv corresponding to the 128-slice DSCT, 64-slice DSCT, 64-slice SSCT and 320-slice CT scanners. In this study a positive relationship was found between the effective dose and the body mass index (BMI). A low radiation dose is achieved in prospective ECG-triggered CCTA, regardless of the CT scanner generation. BMI is identified as the major factor that has a direct impact on the effective dose associated with prospective ECG-triggered CCTA.
    Matched MeSH terms: Coronary Angiography/classification; Coronary Angiography/statistics & numerical data*
  14. Sabarudin A, Md Yusof AK, Tay MF, Ng KH, Sun Z
    Radiat Prot Dosimetry, 2013;153(4):441-7.
    PMID: 22807493 DOI: 10.1093/rpd/ncs127
    This study was conducted to investigate the effectiveness of dose-saving protocols in dual-source computed tomography (CT) coronary angiography compared with invasive coronary angiography (ICA). On 50 patients who underwent coronary CT angiography was performed dual-source CT (DSCT) and compared with ICA procedures. Entrance skin dose (ESD), which was measured at the thyroid gland, and effective dose (E) were assessed for both imaging modalities. The mean ESD measured at the thyroid gland was the highest at 120 kVp, followed by the 100 kVp DSCT and the ICA protocols with 4.0±1.8, 2.7±1.0 and 1.1±1.2 mGy, respectively. The mean E was estimated to be 10.3±2.1, 6.2±2.3 and 5.3±3.4 mSv corresponding to the 120-kVp, 100-kVp DSCT and ICA protocols, respectively. The application of 100 kVp in DSCT coronary angiography is feasible only in patients with a low body mass index of <25 kg m(-2), which leads to a significant dose reduction with the radiation dose being equivalent to that of ICA.
    Matched MeSH terms: Coronary Angiography/instrumentation*; Coronary Angiography/methods*
  15. Jayasinghe R, Weerasooriya S, Kapadia N
    Med J Malaysia, 2012 Apr;67(2):236-9; quiz 240.
    PMID: 22822658
    How does one decide on the best non-invasive test to investigate stable coronary ischaemia? This is a very common question faced by many medical practitioners. Chronic stable angina is a common presentation encountered in general practitice. Upon clinical assessment and risk stratification the patient needs to be investigated further to confirm the diagnosis. The first investigational modality involves a non-invasive test. It is important that practitioners possess a practical knowledge of the array of different tests that are available so that the best suited one for each patient can be chosen. This article aims to compare the efficacy and accuracy and the practical utility of the different non-invasive tests for coronary ischaemia and aid the practitioner in making sound decisions in this regard.
    Matched MeSH terms: Coronary Angiography
  16. Chin BS, Ong TK, Seyfarth TM, Liew CK, Chan WL, Rapaee A, et al.
    J Comput Assist Tomogr, 2006 7 18;30(4):564-8.
    PMID: 16845284
    BACKGROUND AND OBJECTIVE: We hypothesized that a "culprit" lesion in acute coronary syndrome (ACS) should have low overall vessel lumen and plaque density on multidetector computed tomography-assisted coronary angiography (MDCTA) because of lower calcification and the presence of occlusive thrombus. However, thrombi and calcification both can themselves blur the demarcation between vessel wall and lumen. If we calculated a "vessel density ratio" (VDR) obtained by measuring the mean density of contrast-enhancement within a region of interest (ROI), which includes the vessel wall, lumen, plaque, and thrombus, and comparing that with the aortic root mean density acting as a reference point, this ratio may be more convenient, standardized, and reproducible to test the feasibility of VDR in identifying "culprit" lesions in ACS.

    METHODS: Sixty-four patients-21 exertional angina; 17 unstable angina/non-ST elevation myocardial infarction (NSTEMI); 26 ST elevation myocardial infarction (STEMI)-provided 188 diseased segments on conventional angiography. All underwent MDCTA within a week of angiography. ROI was mapped out from maximum intensity projections of diseased segments in planar view.

    RESULTS: One hundred seventy-four segments were evaluated. Patients who presented with ACS (STEMI and unstable angina/non-ST elevation myocardial infarction) had lower mean VDR compared to patients with exertional angina (0.58 vs. 0.66 vs. 0.81; P < 0.001). Culprit lesions in ACS patients also had the lowest mean VDR when compared to nonculprit lesions and lesions in patients without ACS (0.51 vs. 0.68 vs. 0.81; P < 0.001).

    CONCLUSIONS: VDR is a new, convenient, and standardized approach in identifying "culprit" lesions by MDCTA.

    Matched MeSH terms: Coronary Angiography
  17. Ong HT
    Med J Malaysia, 1991 Dec;46(4):379-83.
    PMID: 1840450
    A 61-year old lady presented clinically in unstable angina with ST-segment depression typical of myocardial ischemia. However, coronary arteries were completely normal at angiography. Exercise testing reproduced symptoms and ST-segment depression. A diagnosis of Syndrome X was made, an uncommon disorder of myocardial ischemia with normal coronary anatomy and excellent prognosis.
    Matched MeSH terms: Coronary Angiography
  18. Loong CW, Firdaus MAM, Said MRM, Abidin IZ
    Medeni Med J, 2020;35(3):266-270.
    PMID: 33110680 DOI: 10.5222/MMJ.2020.47374
    Takotsubo syndrome is a rare disease and remained ambiguous with its etiology. The disease manifests in various clinical characteristics and even mimicking acute coronary syndrome. We are reporting a case of an elderly lady who manifested by unsteady gaits and recurrent falls. Subacute infarct of the right corona radiata was observed on the brain CT. In addition, coronary angiography and ventriculogram were performed because of dynamic ECG changes and elevated troponin I levels. The angiogram was normal while ventriculogram showed apical ballooning. She was diagnosed and treated as Takotsubo syndrome.
    Matched MeSH terms: Coronary Angiography
  19. Shahril Shamsul, Akmal Sabarudin, Hamzaini Abdul Hamid, Norzailin Abu Bakar, Oteh Maskon, Muhammad Khalis Abdul Karim
    MyJurnal
    The purpose of this study was to evaluate the image quality and diagnostic accuracy of coronary computed tomography angiography (CCTA) using 640-slice scanner. Advancement of multidetector computed tomography (MDCT) technology with higher spatial, temporal resolution, and increasing detector array have improved the image quality and diagnostic accuracy of CCTA. A total of 25 patients (12 men and 13 women) underwent CCTA examination was chosen and data was acquired by 640-slice scanner. All 16 segments of coronary arteries were evaluated by two reviewers using a 4-likert scale for qualitative assessment. In quantitative assessment, the evaluation of 4 main coronary arteries were analysed in terms of signal intensity (SI), image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All 25 patients with a mean age of 52.88 ± 14.75 years old and body mass index (BMI) of 24.24 ± 3.28 kg/m2 were analysed. In qualitative assessment, from the total of 400 segments, 379 segments (95%) had diagnostic value while 21 segments did not have diagnostic value, which means 5% artefact was detected. In quantitative assessment, there was no statistical differences in gender, race, and BMI (p>0.05). Overall evaluation showed that higher SI at the left main artery (LM) at 393.7 ± 47.19. Image noise was higher at right coronary artery (RCA) at 39.01 ± 13.97. SNR and CNR showed higher at left anterior descending (LAD) with 12.73 ± 5.17 and LM 9.14 ± 4.2, respectively. In conclusion, this study indicates that 640-slice MDCT has higher diagnostic value in CCTA examination with 95% vessel visibility with 5% artefact detection.
    Matched MeSH terms: Coronary Angiography