METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.
RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).
CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.
METHOD: From January 2013 to December 2015, patients aged 6 months and below with duct-dependent pulmonary circulation underwent CT angiography to delineate the ductus arteriosus origin, tortuosity, site of insertion, and pulmonary artery anatomy. The ductus arteriosus were classified into type I, IIa, IIb, and III based on its site of origin, either from descending aorta, distal arch, proximal arch, or subclavian artery, respectively.
RESULTS: A total of 114 patients and 116 ductus arteriosus (two had bilateral ductus arteriosus) were analysed. Type I, IIa, IIb, and III ductus arteriosus were seen in 13 (11.2 %), 71 (61.2%), 21 (18.1%), and 11 (9.5%), respectively. Tortuous ductus arteriosus was found in 38 (32.7%), which was commonly seen in single ventricular lesions. Ipsilateral and bilateral branch pulmonary artery stenosis was seen in 68 (59.6%) and 6 (5.3%) patients, respectively. The majority of patients with pulmonary atresia intact ventricular septum had type I (54.4%) and non-tortuous ductus arteriosus, while those with single and biventricular lesions had type II ductus arteriosus (84.9% and 89.7%, respectively). Type III ductus arteriosus was more common in biventricular lesions (77.8%).
CONCLUSIONS: Ductus arteriosus in duct-dependent pulmonary circulation has a diverse morphology with a distinct origin and tortuosity pattern in different types of ventricular morphology. CT may serve as an important tool in case selection and pre-procedural planning for ductal stenting.
METHODS: The 3D-printed cardiac insert phantom was positioned into a chest phantom and scanned with a 16-slice CT scanner. Acquisitions were performed with CCTA protocols using 120 kVp at four different tube currents, 300, 200, 100 and 50 mA (protocols A, B, C and D, respectively). The image data sets were reconstructed with a filtered back projection (FBP) and three different IR algorithm strengths. The image quality metrics of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were calculated for each protocol.
RESULTS: Decrease in dose levels has significantly increased the image noise, compared to FBP of protocol A (P
AIMS: This study aimed to examine the influence of vessel volume on bolus thermodilution measurements.
METHODS: We prospectively included patients with angina with non-obstructive coronary arteries (ANOCA) undergoing bolus and continuous thermodilution assessments. All patients underwent coronary CT angiography to extract vessel volume. Coronary microvascular dysfunction was defined as coronary flow reserve (CFR)
METHODS: Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software.
RESULTS: Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp.
CONCLUSIONS: There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.