Displaying publications 21 - 40 of 592 in total

Abstract:
Sort:
  1. Ming CH, Fan YS
    J Immunol Methods, 1988 May 09;109(2):253-5.
    PMID: 3361136
    Addition of the non-ionic detergent Tween 20 to the serum diluent enhances anti-cardiolipin binding reactivity in an ELISA system. Maximal enhancement was obtained using a concentration of 0.05% Tween 20 in the diluent. Non-specific interactions were also considerably reduced.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  2. Balachandra D, Rahumatullah A, Lim TS, Mustafa FH, Ahmad H, Anuar NS, et al.
    Acta Trop, 2021 Sep;221:105986.
    PMID: 34058161 DOI: 10.1016/j.actatropica.2021.105986
    Serodiagnosis is an essential component of the laboratory diagnosis of Strongyloides infection and is usually performed using an indirect IgG antibody test. A direct antigen detection method can complement the IgG assay, particularly for detecting early infection and post-treatment follow-up. In the present study, a recombinant scFv monoclonal antibody against NIE recombinant protein (rMAb23) that we had previously produced was used to develop a Strongyloides antigen detection ELISA (SsAg-ELISA). The assay is based on detecting immune complexes of circulating NIE antigens bound to Strongyloides-specific IgG antibodies. The optimized ELISA parameters were 10 µg/mL of rMAb23 coated on microtitre plate wells, 2% skim milk as blocking reagent, 1:100 serum dilution, and 1:1000 goat anti-human IgG F(ab')2 conjugated to horseradish peroxidase. Four groups of serum samples were used, i.e., Strongyloides-positive serum samples categorized into Groups IA and IB; the former were from probable chronic infections and the latter from probable early/acute infections. Strongyloides-negative samples comprising Groups II (healthy samples) and III (other infections); the latter were from eleven different types of other parasitic infections. The receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 1.00, cut-off optical density (OD405) of 0.5002, and 100% diagnostic sensitivity and specificity. The results of the commercial IgG-ELISA and SsAg-ELISA from Group IA were found to be moderately correlated (r = 0.416; p 
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  3. Shamsul, B.S., Zakirah, M.
    MyJurnal
    The main objective of this study is to determine the association between respirable hexavalent chromium compounds with urinary β2-microglobulin levels among welders in an automotive components manufacturing plant. 49 welders and 39 workers involved in stamping process were selected as the exposed and the comparative group. β2-microglobulin is a protein renal tubular dysfunction marker that can indicate renal dysfunction caused by heavy metal. Air samples of worker’s breathing zone were collected using personal air sampling pump and filter papers. Filter papers were then diluted and analysed with Atomic Absorption Spectrophotometry (AAS). Workers’ urine samples were collected at the end of 8-hour work shift and analysed with β2-microglobulin ELISA Kit (IBL-Hamburg) and a microtiter reader. Meanwhile, creatinine levels were analysed with creatinine test strips and Reflotron®. A mean concentration of respirable hexavalent chromium compounds in air for the exposed group was 0.135 ± 0.043μg/m3 while for the non-exposed group was 0.124 ± 0.029μg/m3. The mean level of urinary β2-microglobulin per creatinine for the exposed group was 84.996 ± 39.246μg/g while that of the comparative group was 61.365 ± 21.609μg/g. The concentrations of respirable hexavalent chromium compounds were higher in the exposed group compared to the comparative group (Z=-2.444, p=0.015). β2-microglobulin level was also higher in the exposed group compared to the non-exposed group (t=3.821, p=
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  4. Shamsul, B.S., How Pai, S.
    MyJurnal
    Homocysteine could be a mechanism that underlies the effects of lead on cardiovascular system. This study aims to identify the relationship between lead exposure and homocysteine levels among workers. A comparative cross-sectional study was carried out on 80 workers of an automotive components manufacturing factory; that comprised of 40 exposed workers and 40 non-exposed workers. Blood samples of respondents were taken by fingerprick. The blood samples were analyzed for blood lead concentration by using Atomic Absorption Spectrometry Graphite Furnace Model GBC 908AA. Besides that, ELISA Kit was used to show the homocysteine level among the respondents. Questionnaires were used to obtain demography information of respondents. Results from the statistical analysis showed that the mean blood lead concentration for exposed respondents was 5.53±4.74 μg/dL and 3.53±2.81 μg/dL for the comparative respondents. Mann-Whitney U test showed that there was no significance difference between the mean blood lead concentration of the exposed and comparative group (z=-1.178; p=0.075). The blood lead concentration ranged 0.68-17.95 among the exposed group and with a range of 0.084-11.96 for the comparative group. The mean homocysteine level (μmol/L) was 32.48±2.481μmol/L for the exposed group and 16.50±4.0960 μmol/L for the comparative group. There was a significant difference in homocysteine level (μmol/L) between the exposed (32.48±2.481) and comparative (16.50±4.0959) groups (z = -7.699, p
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  5. Tahir D, Shariff M, Syukri F, Yusoff FM
    Vet World, 2018 Mar;11(3):327-331.
    PMID: 29657425 DOI: 10.14202/vetworld.2018.327-331
    Background and Aim: Brown-marbled grouper Epinephelus fuscoguttatus is a premium marine food fish with high demand in Asia. In fish, stress due to environmental changes such as fluctuations in the salinity can result in increased cortisol level. Stress in fish increases susceptibility to diseases ultimately resulting in death. Therefore, the aim of this study was to investigate the salinity tolerance of E. fuscoguttatus and their survival in lower salinities.

    Materials and Methods: In this study, grouper juveniles (92.43±standard error of the mean 0.51 mm) maintained in 31 ppt seawater were transferred into five tanks with seawater diluted to 25, 20, 15, 10, and 5 ppt. The salinity of the control group was not changed and was maintained at 31 ppt. Serum cortisol was measured using ELISA at 0, 30, 60, and 120 min after the fish were transferred to the different concentrations of salinity.

    Results: The survival percentage was recorded for 14 days following the transfer and the results revealed that serum cortisol of fish in a high change in salinity (15, 10, and 5 ppt) was significantly higher than the control group immediately after exposure. At the high salinity change, the cortisol levels gradually decrease at 30 min and 60 min, until no difference in cortisol concentration was observed at 120 min. No mortality was observed in fish exposed to low salinity change (25 and 20 ppt) while in higher salinity change (5 ppt), the survival percentage was 50%.

    Conclusion: The study revealed that the serum cortisol concentration was high initially and continues to decrease to resting cortisol level at 120 min indicating that cortisol hormone is released following acute stress as a primary response in grouper juveniles.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  6. Ambrose JH, Sekaran SD, Azizan A
    J Trop Med, 2017;2017:8072491.
    PMID: 28740517 DOI: 10.1155/2017/8072491
    BACKGROUND: The proper management of patients infected with dengue virus requires early detection. Here, real-time molecular assays have proven useful but have limitations, whereas ELISAs that detect antibodies are still favored but results are obtained too late to be of clinical value. The production of DENV NS1 peaks early during infection and its detection can combine the advantages of both diagnostic approaches.

    METHODS: This study compared assays currently used for detecting DENV infection at the Florida Department of Health including anti-DENV IgM and IgG ELISAs as well as qRT-PCR, against a commercially available DENV NS1 ELISA. These comparisons were made among a group of 21 human sera.

    RESULTS: Nine of 14 (64.3%) DENV qRT-PCR+ samples were also DENV NS1+. Interestingly, the 5 NS1- samples that were qRT-PCR+ were additionally IgM- and IgG+ suggesting a nonprimary infection. Compared to qRT-PCR, the NS1 assay had a sensitivity of 64.3%, specificity 100%, PPV of 100%, and NPV of 58.3%.

    CONCLUSIONS: The NS1 ELISA performed as expected in known DENV qRT-PCR+ samples; however negative NS1 results for qRT-PCR+ and IgG+ sera seemingly reduced the usefulness of the NS1 ELISA for nonprimary cases. We therefore conclude that diagnosis obtained via DENV NS1 ELISA deserves further investigation.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  7. Hosseini S, Azari P, Cardenas-Benitez B, Martínez-Guerra E, Aguirre-Tostado FS, Vázquez-Villegas P, et al.
    Mater Sci Eng C Mater Biol Appl, 2020 Apr;109:110629.
    PMID: 32228934 DOI: 10.1016/j.msec.2020.110629
    Based on the concept of LEGO toys, a fiber probe analytical platform (FPAP) was developed as a powerful diagnostic tool offering higher sensitivity in detection of infectious agents compared to established methods. Using the form and the function of LEGO toys, this protocol describes a fiber-based, 96-well plate, which suspends a new class of chemically-designed, electrospun fibers within the assay. This clamping strategy allows both sides of the developed fiber mats to interact with biomolecules within the assay thus benefiting from the tailored chemical and physical properties of these fiber-based bioreceptors in attracting the biomolecules to the surface. The fabrication method of FPAP involves one-step electrospinning of the chemically designed fibers, 3D printing of the LEGO-like probing segments, and assembly of the device followed by ELISA procedure. FPAP follows the same principles of operation as that of a conventional enzyme linked immunosorbent assay (ELISA), therefore, it can be run by lab technicians, expert in ELISA. FPAP was used for early diagnosis of Dengue fever and provided an 8-fold higher sensitivity while the limit of detection (LOD) was recorded to be in femto-gram per milliliter range which is significantly low when compared to other existing techniques or conventional assay. This platform allows different types of paper/fiber bio-receptive platforms to be incorporated within the design that promises simultaneous recognition of multiple infectious agents.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  8. Moon JY, Kim WK, Choi YH, Choi MS, Hur J, Kang JY, et al.
    Sains Malaysiana, 2017;46:217-221.
    The efficacy of the combination vaccine of the individual C-terminal fragments of ApxIA, ApxIIA and ApxIIIA of Actinobacillus pleuropneumoniae (APP) was evaluated in piglets. Twenty piglets were divided equally into 2 groups (n=10). All piglets were intramuscularly primed at 4 week-of-age (0 week post prime inoculation (WPPI)) and were intramuscularly boosted at 6 week-of-age (2 WPPI). Group A piglets were inoculated with sterile PBS and group B piglets were inoculated with the combination vaccine. Concentrations of each of the C-terminal fragment-specific IgG as determined by ELISA were significantly higher in group B than in group A from 2 WPPI until the end of this study. Clinical signs were observed from only 10% of group B piglets after the challenge with the mixture of APP serotypes 1, 2 and 5 at 4 WPPI, while 50% of group A piglets were protected against APP infections. Overall, intramuscular inoculation with the vaccine candidate can efficiently protect piglets against APP infection.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  9. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  10. Wei W, Tang Y, He H, Gopinath SCB, Wang L
    Biotechnol Appl Biochem, 2022 Feb;69(1):160-165.
    PMID: 33369762 DOI: 10.1002/bab.2092
    Acute myocardial infarction (AMI) is the heart attack happening when the blood flow is terminated to the heart muscles. C-reactive protein (CRP) level is raising significantly in AMI patients after the onset of symptom; also, temporal variations of CRP in plasma of AMI patient have also been found. Quantifying the concentration of CRP helps to identify the condition associated with AMI. Plasmonic enzyme-linked immunosorbent assay (ELISA) was utilized here to identify CRP by the sandwich of aptamer and antibody. Bare-eye CRP detection was achieved by plasmonic ELISA through the aggregation (blue color) of gold nanoparticle in the presence of CRP, whereas in the absence of CRP, it retains its red color (dispersion). Depending on the catalase presence on the ELISA surface, hydrogen peroxide (H2 O2 ) controls gold growth and differentiates with color changes. To achieve the lowest detection limit of CRP, H2 O2 (200 µM), gold seed (0.2 µM), and streptavidin-catalase (1:500) were found optimal. The detection limit was reached at 0.25 µg/mL, whereas it was 0.5 µg/mL in the CRP-spiked serum. This method of detection system is easier to detect the levels of CRP and helps diagnosing AMI.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  11. Thergarajan G, Sekaran SD
    Expert Rev Mol Diagn, 2023;23(8):643-651.
    PMID: 37417532 DOI: 10.1080/14737159.2023.2234815
    INTRODUCTION: Every year, a significant rise in dengue incidence observed is responsible for 10% of fever episodes in children and adolescents in endemic countries. Considering that the symptoms of dengue are similar to those of many other viruses, early diagnosis of the disease has long been difficult, and lack of sensitive diagnostic tools may be another factor contributing to a rise in dengue incidence.

    AREAS COVERED: This review will highlight dengue diagnostics strategies and discuss other possible targets for dengue diagnosis. Understanding the dynamics of the immune response and how it affects viral infection has enabled informed diagnosis. As more technologies emerge, precise assays that include some clinical markers need to be included.

    EXPERT OPINION: Future diagnostic strategies will require the use both viral and clinical markers in a serial manner with the use of artificial intelligence technology to determine from the first point of illness to better determine severity status and management. A definitive endpoint is not in the horizon as the disease as well as the virus is constantly evolving and hence many developed assays need to be constantly changing some of their reagents periodically as newer genotypes and probably too serotypes emerge.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  12. Wang H, Vidyadaran S, Mohd Moklas MA, Baharuldin MTH
    PMID: 29358962 DOI: 10.1155/2017/2623163
    Objective: To explore the effect of Ficus deltoidea (FD) aqueous extracts on the release of tumor necrosis factor-α (TNF-α), the expression of CD40, and the morphology of microglial cells in lipopolysaccharide- (LPS-) activated BV2 cells.

    Methods: The cytotoxicity of FD extract was assessed by MTS solution. BV2 cells were divided into 5 experimental groups, intervened, respectively, by FD (4 mg/mL) and LPS + FD (0, 1, 2, and 4 mg/mL). Besides, a blank control group was set up without any intervention. TNF-α release was assessed by enzyme linked immunosorbent assay (ELISA). The expression of CD40 was examined by flow cytometry. Immunocytochemical staining was used to show the morphology of BV2 cells.

    Results: FD extract of different concentrations (1, 2, and 4 mg/mL) had no significant toxic effects on the BV2 cells. FD suppressed the activation of microglia in morphology and reduced TNF-α production and expression of CD40 induced by LPS.

    Conclusion: FD extract has a therapeutic potential against neuroinflammatory diseases.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  13. Hunsperger EA, Yoksan S, Buchy P, Nguyen VC, Sekaran SD, Enria DA, et al.
    PLoS Negl Trop Dis, 2014 Oct;8(10):e3171.
    PMID: 25330157 DOI: 10.1371/journal.pntd.0003171
    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60-75% and specificity 71-80%; NS1 RDT sensitivity was 38-71% and specificity 76-80%; the IgM anti-DENV RDTs sensitivity was 30-96%, with a specificity of 86-92%, and IgM anti-DENV ELISA sensitivity was 96-98% and specificity 78-91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88-94%.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  14. Toh SY, Citartan M, Gopinath SC, Tang TH
    Biosens Bioelectron, 2015 Feb 15;64:392-403.
    PMID: 25278480 DOI: 10.1016/j.bios.2014.09.026
    The application of antibodies in enzyme-linked immunosorbent assay (ELISA) is the basis of this diagnostic technique which is designed to detect a potpourri of complex target molecules such as cell surface antigens, allergens, and food contaminants. However, development of the systematic evolution of Ligands by Exponential Enrichment (SELEX) method, which can generate a nucleic acid-based probe (aptamer) that possess numerous advantages compared to antibodies, offers the possibility of using aptamers as an alternative molecular recognition element in ELISA. Compared to antibodies, aptamers are smaller in size, can be easily modified, are cheaper to produce, and can be generated against a wide array of target molecules. The application of aptamers in ELISA gives rise to an ELISA-derived assay called enzyme-linked apta-sorbent assay (ELASA). As with the ELISA method, ELASA can be used in several different configurations, including direct, indirect, and sandwich assays. This review provides an overview of the strategies involved in aptamer-based ELASA.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay*
  15. Noordin R, Smith HV, Mohamad S, Maizels RM, Fong MY
    Acta Trop, 2005 Jan;93(1):57-62.
    PMID: 15589798
    Diagnosis of human toxocariasis, caused by Toxocara canis or Toxocara cati, normally relies on a combination of the presence of clinical signs and symptoms backed by positive serology. The use of Toxocara excretory-secretory antigen (TES) in ELISA assays increases the test specificity. However, in tropical countries where soil-transmitted helminths are endemic, cross-reactivity from antibodies to these intestinal parasites poses a significant limitation for Toxocara serodiagnosis. To increase the specificity of serodiagnosis, we compared the use of IgG-ELISA to the use of IgG4-ELISA using commercially manufactured TES-coated plates. The sensitivity of the IgG-ELISA was 97.1%, while that of the IgG4-ELISA was 45.7%; the specificities were 36.0 and 78.6%, respectively. The study shows that employing both assays can improve the serodiagnosis of toxocariasis. An IgG4 immunoassay would also be useful in the secondary screening of antigen clones in the effort to develop improved serological tests for toxocariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  16. Ng LC, Teng LC, Ng ML, Sazali BS, Khalid BA
    Malays J Pathol, 2000 Dec;22(2):73-8.
    PMID: 16329538
    Detection of microalbuminuria is important in the management of diabetic patients since it is predictive of development of proteinuria and nephropathy. Two sensitive and specific in-house ELISAs for microalbuminuria were established and validated. One of the ELISAs was based on antigen coating while the other employed antibody coating. Recovery and linearity experiments gave acceptable results of 100 +/- 10%, while precision results were <10% for intra-assay and <12% for inter-assay coefficients of variation (CVs). The standard curve ranged from 10-625 ug/l, equivalent to 0.2-12.5 mg/l for urine samples diluted 1:20 fold. When the antibody coated ELISA was compared to antigen coated ELISA, a correlation of r=0.996 was obtained. When compared to commercial kits, the in-house ELISAs gave good correlations of r=0.961 versus the Boehringer Mannheim Micral Test strips and r=0.940 versus Ames Microalb Turbidimetry. The normal microalbumin reference ranges determined for 12h, first morning and random urine samples were 0.7-5.3 mg, 0.1-10.2 mg/l and 0.8-26.1 mg/l respectively. The normal albumin excretion rate (AER) was 1.0-7.3 ug/min while untimed urine samples gave results of 0.1-0.9 and 0.2-1.6 mg/mmol after dividing by creatinine concentrations. The ELISAs were used to detect microalbuminuria in 338 random urine samples from diabetic patients. A high percentage 47.9% was found to be positive for microalbuminuria and 18.0% had macroalbuminuria >25 mg/mmol. Thus screening for microalbuminuria together with creatinine measurements using random urine samples can be used for management of diabetic patients.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  17. Muniandy S, Qvist R, Zaini A, Chinna K, Ismail IS
    PMID: 16295560
    The concentration of plasma sialic acid was estimated using the modified chemical method and the more sensitive enzymatic method in 20 subjects with impaired glucose tolerance and 20 control subjects. The mean sialic acid concentration values of the control subjects and subjects with impaired glucose tolerance using the enzymatic method were 1.747 +/- 0.047 and 2.583 +/- 0.070 mmole/l and 1.753 +/- 0.067 and 2.591 +/- 1.02 mmole/l for the chemical method. The intra-assay coefficient of variation for the control subjects and for the subjects with impaired glucose tolerance were 1.963% and 1.583%, respectively, for the enzymatic assay and 2.728% and 2.431%, respectively, for the chemical assay. The inter-assay coefficient of variation for the control subjects and for the subjects with impaired glucose tolerance were 2.686% and 2.723% for the enzymatic assay, and 3.819% and 3.95% for the chemical assay. Since the values do not differ significantly, the chemical assay is a cost effective method that can be used in large epidemiological studies.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  18. Thiha A, Ibrahim F
    Sensors (Basel), 2015;15(5):11431-41.
    PMID: 25993517 DOI: 10.3390/s150511431
    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation*
  19. Rahmah N, Ashikin AN, Anuar AK, Ariff RH, Abdullah B, Chan GT, et al.
    Trans R Soc Trop Med Hyg, 1998 12 16;92(4):404-6.
    PMID: 9850392
    A polymerase chain reaction assay based on the enzyme-linked immunosorbent assay (PCR-ELISA) has been developed to detect Brugia malayi infection in an area of low endemicity in Malaysia. Blood samples from 239 subjects were tested: 192 amicrofilaraemic individuals, 14 microfilaraemic persons and 3 chronic elephantiasis cases from endemic areas and 30 city-dwellers (non-endemic controls). PCR products were examined by ELISA and Southern hybridization. In the PCR-ELISA, digoxigenin-labelled PCR products were hybridized to a biotin-labelled probe. This was followed by incubation in streptavidin-coated microtitre wells and detection using anti-digoxigenin-peroxidase and ABTS [2,2'-azinobis(3-ethylbenzthiazoline-6-sulphonic acid)]. All microfilaraemic samples were positive by PCR-ELISA and Southern hybridization and all samples from non-endemic subjects and chronic elephantiasis patients were negative. The PCR-ELISA detected 12 times as many B. malayi infections as did thick blood film examination. Nineteen of the 194 samples from the endemic area gave positive results by both PCR-ELISA and Southern hybridization, and an additional 5 samples were positive by PCR-ELISA only. The PCR-ELISA was specific and sensitive, detected more infections, and was more reproducible than Southern hybridization.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  20. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*