METHODS: A total of 521 students from a public university in East Malaysia were asked to complete the Malay versions of the Suicidal Behaviour Questionnaire-Revised (SBQ-R), the Attitudes Towards Suicide Scale, and the Depression Anxiety Stress Scale.
RESULTS: 197 women and 290 men (mean age, 19.13 years) completed the questionnaires, giving a response rate of 93.4%. The prevalence of high-risk suicidal behaviour (SBQ-R score ≥7) was 23.8%. Suicidal behaviour was positively associated with psychological distress and favourable attitudes towards suicide, and negatively associated with unfavourable attitudes towards suicide. Predictors for suicidal behaviour were psychological distress and favourable attitudes towards suicide ('the ability to understand and accept suicide').
CONCLUSION: The prevalence of suicidal behaviour is high among students in a public university in East Malaysia. Services and education for mental health awareness and screening for early detection and intervention of psychological distress should be provided to university students. Implementation of suicide awareness policies and suicide prevention training is crucial.
METHODS: A cross-sectional, hospital-based study. Fifty-four OSA subjects and 54 controls were recruited. Candidate that fulfil the criteria with normal ocular examinations then proceed with spectrum domain Cirrus optical coherence tomography examinations. ONH parameters and RNFL thickness were evaluated. Apnoea-hypopnoea index (AHI) of the OSA group were obtained from the medical record.
RESULTS: In OSA, mean of average RNFL thickness was 93.87 µm, standard deviation (SD) = 9.17, p = 0.008 (p < 0.05) while superior RNFL thickness was 113.59 µm, SD = 16.29, p ≤ 0.001 (p < 0.05). RNFL thickness fairly correlate with severity of the disease (AHI), superior RNFL with R = 0.293, R2 = 0.087, p = 0.030 (p < 0.05), and nasal RNFL R = 0.292, R2 = 0.085, p = 0.032. No significant difference and correlation observed on ONH parameters. In control group, mean of average RNFL thickness was 98.96 µm, SD = 10.50, p = 0.008 (p < 0.05) while superior RNFL thickness was 125.76 µm, SD = 14.93, p ≤ 0.001 (p < 0.05).
CONCLUSIONS: The mean of the average and superior RNFL thickness were significantly lower in the OSA group compare to control. Regression analysis showed RNFL thickness having significantly linear relationship with the AHI, specifically involving the superior and nasal quadrant.
METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.
RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.
CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.
KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.