OBJECTIVE: In this study, we report a rapid method for the residue analysis of IND and its metabolites, viz., IND-carboxylic acid, diaminotriazine, and triazine indanone in a wide range of palm oil matrices using liquid chromatography-tandem mass spectrometry (LC-MS/MS).
METHOD: The optimized sample preparation workflows included two options: (1) acetonitrile extraction (QuEChERS workflow), followed by freezing at -80°C and (2) acetonitrile extraction, followed by cleanup through a C18 solid phase extraction (SPE) cartridge. The optimized LC runtime was 7 min. All these analytes were estimated by LC-MS/MS multiple reaction monitoring.
RESULTS: Both sample preparation methods provided similar method performance and acceptable results. The limit of quantification (LOQ) of IND, IND-carboxylic acid, and triazine indanone was 0.001 mg/kg. For diaminotriazine, the LOQ was 0.005 mg/kg. The method accuracy and precision complied with the SANTE/12682/2019 guidelines of analytical quality control.
CONCLUSIONS: The potentiality of the method lies in a high throughput analysis of IND and its metabolites in a single chromatographic run with high selectivity and sensitivity. Considering its fit-for-purpose performance, the method can be implemented in regulatory testing of IND residues in a wide range of palm oil matrices that are consumed and traded worldwide.
HIGHLIGHTS: This work has provided a validated method for simultaneous residue analysis of indaziflam and its metabolites in crude palm oil and its derived matrices with high sensitivity, selectivity, and throughput.
MATERIALS AND METHODS: A total of 24 ejaculates were collected from four bulls via an electroejaculator. Semen samples were diluted with 2% VCO in Tris-based extender which consists of various concentrations of SL (1, 1.25, 1.5, and 1.75%). A 20% egg yolk in Tris used as a positive control (C+). The diluted semen samples were divided into two fractions; one for chilling which were stored at 4°C for 24, 72, and 144 h before evaluated for semen quality parameters. The second fraction used for freezing was chilled for 3 h at 4°C, packed into 0.25 mL straws and then cryopreserved in liquid nitrogen. The samples were then evaluated after 7 and 14 days. Chilled and frozen semen samples were thawed at 37°C and assessed for general motility using computer-assisted semen analysis, viability, acrosome integrity and morphology (eosin-nigrosin stain), membrane integrity, and lipid peroxidation using thiobarbituric acid reaction test.
RESULTS: The results showed that all the quality parameters assessed were significantly (p<0.05) improved at 1.5% SL concentration in chilled semen. Treatment groups of 1, 1.25, 1.5, and 1.75% SL were higher in quality parameters than the control group (C+) in chilled semen. However, all the quality parameters in frozen-thawed semen were significantly higher in the C+ than the treated groups.
CONCLUSION: In conclusion, supplementation of 1.5% SL in 2% VCO Tris-based extender enhanced the chilled bull semen. However, there was no marked improvement in the frozen-thawed quality parameters after treatment.