Displaying publications 41 - 60 of 91 in total

Abstract:
Sort:
  1. Low PL, Yong BE, Ong BH, Matsumoto M, Tou TY
    J Nanosci Nanotechnol, 2011 Mar;11(3):2640-3.
    PMID: 21449444
    The substrate effects on surface morphologies, crystal structures, and magnetic properties of the sputter-deposited FePt thin films on Corning 1737, normal glass, and Si wafer substrates, respectively, were investigated. High in-plane coercivities of 10 kOe were obtained for the air-annealed films on Corning 1737 and Si wafer, where both films similarly have granular-like morphologies. Besides, increasing grain size and surface roughness of all the FePt films with the post-anneal temperature were observed. Moreover, partially separated grains were seen in the film on Si wafer, where the formation of Fe silicides during post-anneal is suspected, in which has enhanced the magnetic ordering.
    Matched MeSH terms: Magnetics*
  2. Lund LA, Omar Z, Khan I
    Comput Methods Programs Biomed, 2019 Dec;182:105044.
    PMID: 31491654 DOI: 10.1016/j.cmpb.2019.105044
    BACKGROUND AND OBJECTIVE: The last two and half decades are witnessed a great surge in the use convective fluids for enhancement of heat transfer of minerals ethylene glycol, oil and water due to their numerous applications in the industrial segments including chemical production, microelectronics, power generation, transportation, and air-conditioning. For this purpose, different procedures were applied to upgrade the thermal conductivity of common fluid but could not. Further, Choi and Eastman in 1995 introduced nanofluid which has good thermal properties as compared to common fluids. After that, it can be seen that researchers, mathematicians, and scientists tried to understand the principles of nanofluids and how to implicate them in many different practical applications. In this work, the Buongiorno model has been considered for nanofluid. One of the prime objectives is to consider all possible multiple solutions of the model because these solutions cannot be seen experimentally.

    METHODS: The governing equations of fluid flow have been transformed in the form of ordinary differential equations. These equations have been solved by two methods namely, shooting method and three-stage Lobatto IIIa formula.

    RESULTS: The effects of different parameters on temperature, velocity, concentration profiles, skin friction coefficient, Sherwood number, and reduced Nusselt number were obtained and presented graphically. It was noticed that four solutions existed at definite ranges of the parameters for high suction over both surfaces for the first time. The results of the stability analysis revealed that only the first solution is more stable and possess physical reliability compared to the remaining solutions.

    CONCLUSION: The graphs also indicated that the fluid velocity decreases as the thermophoresis parameter increases but the opposite behavior observed for both temperature and concentration profiles in the first solution. Furthermore, it was detected that the concentration profile declined at the higher values of the Brownian motion parameter.

    Matched MeSH terms: Magnetics*
  3. Markus A, Gbadamosi AO, Yusuff AS, Agi A, Oseh J
    Environ Sci Pollut Res Int, 2018 Dec;25(35):35130-35142.
    PMID: 30328041 DOI: 10.1007/s11356-018-3402-3
    In this study, a new magnetic adsorbent based on magnetite-sporopollenin/graphene oxide (Fe3O4-SP/GO) was successfully developed. The adsorbent was applied for magnetic solid phase extraction (MSPE) of three selected polar organophosphorus pesticides (OPPs), namely, dimethoate, phenthoate, and phosphamidon, prior to gas chromatography analysis with electron capture detection (GC-μECD). The Fe3O4-SP/GO adsorbent combines the advantages of superior adsorption capability of the modified sporopollenin (SP) with graphene oxide (GO) and magnetite (Fe3O4) for easy isolation from sample solution. Several MSPE parameters were optimized. Under optimized conditions, excellent linearity (R2 ≥ 0.9994) was achieved using matrix match calibration in the range of 0.1 to 500 ng mL-1. The limit of detection (LOD) method (S/N = 3) was from 0.02 to 0.05 ng mL-1. The developed Fe3O4-SP/GO MSPE method was successfully applied for the determination of these three polar OPPs in cucumber, long beans, bell pepper, and tomato samples. Good recoveries (81.0-120.0%) and good relative standard deviation (RSD) (1.4-7.8%, n = 3) were obtained for the spiked OPPs (1 ng mL-1) from real samples. This study is beneficial for adsorptive removal of toxic pesticide compounds from vegetable samples.
    Matched MeSH terms: Magnetics
  4. Mengting Z, Kurniawan TA, Yanping Y, Dzarfan Othman MH, Avtar R, Fu D, et al.
    J Environ Manage, 2020 Sep 15;270:110839.
    PMID: 32721303 DOI: 10.1016/j.jenvman.2020.110839
    We aim at fabricating a ternary magnetic recyclable Bi2WO6/BiOI@Fe3O4 composite that could be applied for photodegradation of tetracycline (TC) from synthetic wastewater. To identify any changes with respect to the composite's morphology and crystal structure properties, ΧRD, FTIR, FESEM-EDS, PL and VSM analyses are carried out. The effects of Fe3O4 loading ratio on the Bi2WO6/BiOI for TC photodegradation are evaluated, while operational parameters such as pH, reaction time, TC concentration, and photocatalyst's dose are optimized. Removal mechanisms of the TC by the composite and its photodegradation pathways are elaborated. With respect to its performance, under the same optimized conditions (1 g/L of dose; 5 mg/L of TC; pH 7; 3 h of reaction time), the Bi2WO6/BiOI@5%Fe3O4 composite has the highest TC removal (97%), as compared to the Bi2WO6 (63%). After being saturated, the spent photocatalyst could be magnetically separated from solution for subsequent use. In spite of three consecutive cycles with 71% of efficiency, the spent composite still has reasonable photocatalytic activities for reuse. Overall, this suggests that the composite is a promising photocatalyst for TC removal from aqueous solutions.
    Matched MeSH terms: Magnetics
  5. Mhd Haniffa MAC, Ching YC, Illias HA, Munawar K, Ibrahim S, Nguyen DH, et al.
    Carbohydr Polym, 2021 Feb 01;253:117245.
    PMID: 33279000 DOI: 10.1016/j.carbpol.2020.117245
    Cellulose with ample hydroxyl groups is considered as a promising supportive biopolymer for fabricating cellulose supported promising magnetic sorbents (CMS) for magnetic solid-phase extraction (MSPE). The easy recovery via external magnetic field, and recyclability of CMS, associated with different types and surface modifications of cellulose has made them a promising sorbent in the field of solid-phase extraction. CMS based sorbent can offer improved adsorption and absorption capabilities due to its high specific surface area, porous structure, and magnetic attraction feature. This review mainly focuses on the fabrication strategies of CMS using magnetic nanoparticles (MNPs) and various forms of cellulose as a heterogeneous and homogeneous solution either in alkaline mediated urea or Ionic liquids (ILs). Moreover, CMS will be elaborated based on their structures, synthesis, physical performance, and chemical attraction of MNPs and their MSPE in details. The advantages, challenges, and prospects of CMS in future applications are also presented.
    Matched MeSH terms: Magnetics
  6. Misron N, Shin NW, Shafie S, Marhaban MH, Mailah NF
    Sensors (Basel), 2011;11(11):10474-89.
    PMID: 22346653 DOI: 10.3390/s111110474
    This paper presents a mobile Hall sensor array system for the shape detection of ferromagnetic materials that are embedded in walls or floors. The operation of the mobile Hall sensor array system is based on the principle of magnetic flux leakage to describe the shape of the ferromagnetic material. Two permanent magnets are used to generate the magnetic flux flow. The distribution of magnetic flux is perturbed as the ferromagnetic material is brought near the permanent magnets and the changes in magnetic flux distribution are detected by the 1-D array of the Hall sensor array setup. The process for magnetic imaging of the magnetic flux distribution is done by a signal processing unit before it displays the real time images using a netbook. A signal processing application software is developed for the 1-D Hall sensor array signal acquisition and processing to construct a 2-D array matrix. The processed 1-D Hall sensor array signals are later used to construct the magnetic image of ferromagnetic material based on the voltage signal and the magnetic flux distribution. The experimental results illustrate how the shape of specimens such as square, round and triangle shapes is determined through magnetic images based on the voltage signal and magnetic flux distribution of the specimen. In addition, the magnetic images of actual ferromagnetic objects are also illustrated to prove the functionality of mobile Hall sensor array system for actual shape detection. The results prove that the mobile Hall sensor array system is able to perform magnetic imaging in identifying various ferromagnetic materials.
    Matched MeSH terms: Magnetics
  7. Misson M, Zhang H, Jin B
    J R Soc Interface, 2015 Jan 06;12(102):20140891.
    PMID: 25392397 DOI: 10.1098/rsif.2014.0891
    The nanobiocatalyst (NBC) is an emerging innovation that synergistically integrates advanced nanotechnology with biotechnology and promises exciting advantages for improving enzyme activity, stability, capability and engineering performances in bioprocessing applications. NBCs are fabricated by immobilizing enzymes with functional nanomaterials as enzyme carriers or containers. In this paper, we review the recent developments of novel nanocarriers/nanocontainers with advanced hierarchical porous structures for retaining enzymes, such as nanofibres (NFs), mesoporous nanocarriers and nanocages. Strategies for immobilizing enzymes onto nanocarriers made from polymers, silicas, carbons and metals by physical adsorption, covalent binding, cross-linking or specific ligand spacers are discussed. The resulting NBCs are critically evaluated in terms of their bioprocessing performances. Excellent performances are demonstrated through enhanced NBC catalytic activity and stability due to conformational changes upon immobilization and localized nanoenvironments, and NBC reutilization by assembling magnetic nanoparticles into NBCs to defray the high operational costs associated with enzyme production and nanocarrier synthesis. We also highlight several challenges associated with the NBC-driven bioprocess applications, including the maturation of large-scale nanocarrier synthesis, design and development of bioreactors to accommodate NBCs, and long-term operations of NBCs. We suggest these challenges are to be addressed through joint collaboration of chemists, engineers and material scientists. Finally, we have demonstrated the great potential of NBCs in manufacturing bioprocesses in the near future through successful laboratory trials of NBCs in carbohydrate hydrolysis, biofuel production and biotransformation.
    Matched MeSH terms: Magnetics*
  8. Mohd Dzaki, Mohd Amir, Sanuri, Ishak
    MyJurnal
    Magnetic actuator driven switchgear is a new medium voltage switchgear technology. In this switchgear, the conventional spring mechanism which is used to operate the circuit breaker is replaced with a magnetic actuator mechanism. The suitability of this technology in the Malaysian utility network specifically in highly loaded areas with frequent switching was assessed via a field evaluation. Preliminary results indicated that magnetic actuator driven switchgear perform commendably on the safety aspect, on-site performance monitoring and online diagnostic test results. However, there are several concerns that need to be addressed such as the ease of installation, substation system requirements, high life cycle cost and reliability of components, before this technology can be used widely.
    Matched MeSH terms: Magnetics
  9. Mousavi Z, Soofivand F, Esmaeili-Zare M, Salavati-Niasari M, Bagheri S
    Sci Rep, 2016 Feb 01;6:20071.
    PMID: 26832329 DOI: 10.1038/srep20071
    In this work, zinc chromite (ZnCr2O4) nanostructures have been synthesized through co-precipitation method. The effect of various parameters such as alkaline agent, pH value, and capping agent type was investigated on purity, particle size and morphology of samples. It was found that particle size and morphology of the products could be greatly influenced via these parameters. The synthesized products were characterized by field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), fourier transform infrared (FT-IR) spectra, X-ray energy dispersive spectroscopy (EDS), photoluminescence (PL) spectroscopy, diffuse reflectance spectroscopy (DRS) and vibrating sample magnetometry (VSM). The superhydrophilicity of the calcined oxides was investigated by wetting experiments and a sessile drop technique which carried out at room temperature in air to determine the surface and interfacial interactions. Furthermore, the photocatalytic activity of ZnCr2O4 nanoparticles was confirmed by degradation of anionic dyes such as Eosin-Y and phenol red under UV light irradiation. The obtained ZnCr2O4 nanoparticles exhibit a paramagnetic behavior although bulk ZnCr2O4 is antiferromagnetic, this change in magnetic property can be ascribed to finite size effects.
    Matched MeSH terms: Magnetics
  10. Mustapha N, Amin N, Chakravarty S, Mandal PK
    Comput Biol Med, 2009 Oct;39(10):896-906.
    PMID: 19665698 DOI: 10.1016/j.compbiomed.2009.07.004
    Flow of an electrically conducting fluid characterizing blood through the arteries having irregular shaped multi-stenoses in the environment of a uniform transverse magnetic-field is analysed. The flow is considered to be axisymmetric with an outline of the irregular stenoses obtained from a three-dimensional casting of a mild stenosed artery, so that the physical problem becomes more realistic from the physiological point of view. The marker and cell (MAC) and successive-over-relaxation (SOR) methods are respectively used to solve the governing unsteady magnetohydrodynamic (MHD) equations and pressure-Poisson equation quantitatively and to observe the flow separation. The results obtained show that the flow separates mostly towards the downstream of the multi-stenoses. However, the flow separation region keeps on shrinking with the increasing intensity of the magnetic-field which completely disappears with sufficiently large value of the Hartmann number. The present observations certainly have some clinical implications relating to magnetotherapy which help reducing the complex flow separation zones causing flow disorder leading to the formation and progression of the arterial diseases.
    Matched MeSH terms: Magnetics*
  11. Muzakkir Mohammad Zainol, Nor Aishah Saidina Amin, Mohd Asmadi
    Sains Malaysiana, 2017;46:773-782.
    The magnetic adsorbents i.e. oil palm frond-magnetic particles (OPF-MP) and oil palm frond activated carbon-magnetic particles (OPFAC-MP) have been prepared by impregnation of iron oxide via co-precipitation method. The magnetic adsorbents and their parent materials were characterized using Fourier transform infrared (FTIR), thermogravimetric analysis (TGA), field emission scanning electron microscopy (FESEM), Brunauer Emmett Teller (BET), Barrett, Joyner & Halenda (BJH) and t-plot method, x-ray diffraction (XRD) and also using vibrating sample magnetometry (VSM) to study their properties and surface chemistry. The activated carbon magnetic adsorbent confers high surface area of 700 m2/g with amorphous structure and magnetic properties of 2.76 emu/g. The OPF-MP and OPFAC-MP were then applied in adsorption study for ions removal of Pb(II), Zn(II) and Cu(II). OPFAC-MP has shown high removal efficiency of 100 % with adsorption capacity up to 15 mg/g of Pb(II), Zn(II) and Cu(II) ions compared to OPF-MP. In addition, the magnetic adsorbents were also compared with their parent materials to observe the effect of magnetic particles. Accordingly, the impregnation of magnetic particles enhances the metal ions adsorption comparing to their parent materials.
    Matched MeSH terms: Magnetics
  12. N. Sulaiman, B. Y. Majlis
    ASM Science Journal, 2013;7(1):27-36.
    MyJurnal
    Measurement of low magnetic field has played an important role in many electronics applications such as navigation, military, non-destructive test, traffic detection as well as medical diagnosis and treatment. The presence of magnetic field, particularly its strength and direction, can be measured using magnetometer. There are many types of magnetometers being investigated through the years and one of the prominent types is fluxgate magnetometer. The main components of fluxgate magnetometer consisting of driving coils, sensing coils and magnetic core are developed by MEMS silicon processing technology. In this paper, an investigation on physical characteristics of the three-dimensional coil structure for a micro-scaled fluxgate magnetometer is presented. The physical characteristics such as width of the coil, distance between successive coils, and gap between the top and bottom coils which would influence the magnetic energy in magnetometer is discussed. In this work, finite-element method simulations to investigate the physical characteristics of the sensing coils were carried out, where the parameter of interest is the coils’ inductance as well as the magnetic flux density. Based on the simulation results, the varying of physical characteristics of the coils had its effects particularly in coil inductance, magnetic flux density, and magnetic energy. It could also be seen that the simulated results agreed with the theoretical aspects of magnetism in a coil. From the investigations, suitable coil dimensions were proposed.
    Matched MeSH terms: Magnetics
  13. Nasir ANM, Yahaya N, Zain NNM, Lim V, Kamaruzaman S, Saad B, et al.
    Food Chem, 2019 Mar 15;276:458-466.
    PMID: 30409620 DOI: 10.1016/j.foodchem.2018.10.044
    Thiol-functionalized magnetic carbon nanotubes (TMCNTs) were employed as the sorbent in the magnetic micro-solid phase extraction (M-µ-SPE) of sulfonamide antibiotics (SAs) in water, milks and chicken meat products prior to high performance liquid chromatography-diode array detector (HPLC-DAD) analysis. The synthesized sorbent was characterized by several spectroscopic techniques. Optimum conditions were: 20 mg of TMCNTs at pH 4, 2 min extraction time, 10% addition of salt and 30 mL of sample volume. Under the optimized TMCNTs-M-µ-SPE and HPLC-DAD conditions, the method showed good linearity in the range of 0.1-500 µg L-1 (r2 ≥ 0.9950), low limits of detection (0.02-1.5 µg L-1), good analytes recovery (80.7-116.2%) and acceptable RSDs (0.3-7.7%, n = 15). The method was applied to tap water (1), milks (15) and commercial chicken meat products (35), SAs were detected in five chicken meat samples (3.0-25.7 µg L-1). The method is critically compared to those reported in the literature.
    Matched MeSH terms: Magnetics
  14. Nasir N, Yahya N, Kashif M, Daud H, Akhtar MN, Zaid HM, et al.
    J Nanosci Nanotechnol, 2011 Mar;11(3):2551-4.
    PMID: 21449424
    This is our initial response towards preparation of nano-inductors garnet for high operating frequencies strontium iron garnet (Sr3Fe5O12) denoted as SrIG and yttrium iron garnet (Y3Fe5O12) denoted as YIG. The garnet nano crystals were prepared by novel sol-gel technique. The phase and crystal structure of the prepared samples were identified by using X-ray diffraction analysis. SEM images were done to reveal the surface morphology of the samples. Raman spectra was taken for yttrium iron garnet (Y3Fe5O12). The magnetic properties of the samples namely initial permeability (micro), relative loss factor (RLF) and quality factor (Q-Factor) were done by using LCR meter. From the XRD profile, both of the Y3Fe5O12 and Sr3Fe5O12 samples showed single phase garnet and crystallization had completely occurred at 900 degrees C for the SrIG and 950 degrees C for the YIG samples. The YIG sample showed extremely low RLF value (0.0082) and high density 4.623 g/cm3. Interesting however is the high Q factor (20-60) shown by the Sr3Fe5O12 sample from 20-100 MHz. This high performance magnetic property is attributed to the homogenous and cubical-like microstructure. The YIG particles were used as magnetic feeder for EM transmitter. It was observed that YIG magnetic feeder with the EM transmitter gave 39% higher magnetic field than without YIG magnetic feeder.
    Matched MeSH terms: Magnetics
  15. Nguyen DM, Soci C, Ooi CH
    Sci Rep, 2016;6:21083.
    PMID: 26879520 DOI: 10.1038/srep21083
    Phaseonium is a three-level Λ quantum system, in which a coherent microwave and an optical control (pump) beams can be used to actively modulate the dielectric response. Here we propose a new metamaterial structure comprising of a periodic array of triangular phaseonium metamolecules arranged as a trefoil. We present a computational study of the spatial distribution of magnetic and electric fields of the probe light and the corresponding transmission and reflection, for various parameters of the optical and microwave beams. For specific values of the probing frequencies and control fields, the phaseonium can display either metallic or dielectric optical response. We find that, in the metallic regime, the phaseonium metamaterial structure supports extremely large transmission, with optical amplification at large enough intensity of the microwave thanks to strong surface plasmon coupling; while, in the dielectric regime without microwave excitation, the transmission bandwidth can be tuned by varying the control beam intensity. Implementation of such phaseonium metamaterial structure in solid-state systems, such as patterned crystals doped with rare-earth elements or dielectric matrices embedded with quantum dots, could enable a new class of actively tunable quantum metamaterials.
    Matched MeSH terms: Magnetics
  16. Nodeh HR, Kamboh MA, Wan Ibrahim WA, Jume BH, Sereshti H, Sanagi MM
    Environ Sci Process Impacts, 2019 Apr 17;21(4):714-726.
    PMID: 30869668 DOI: 10.1039/c8em00530c
    A novel nanocomposite of MGO-NGC, composed of magnetic Fe3O4 nanoparticles (M), graphene oxide (GO), and N-methyl-d-glucamine functionalized calix[4]arene (NGC), was synthesized and applied as an effective adsorbent for the removal of two selected pesticides, namely hexaconazole and chlorpyrifos from water samples. The adsorbent was characterized by FTIR, SEM, EDX, TEM, and XRD. The main parameters affecting the adsorption process such as adsorbent dosage, pH of sample solution, salt effect, pesticide concentration, and adsorption time were investigated. The data from kinetic studies fitted well to the pseudo-second order kinetic model with R2 > 0.99. Among the isotherm models of Langmuir, Freundlich, Temkin, and Dubinin-Radushkevich, the Langmuir isotherm fitted well to the adsorption process and demonstrated the monolayer adsorption pattern of the pesticides. Moreover, high adsorption capacities of 78.74 and 93.46 mg g-1 were obtained for chlorpyrifos and hexaconazole, respectively. Thermodynamic and free energy data indicated the physisorption mechanism for the adsorption process. The new adsorbent can be employed as an efficient, environment friendly, and highly reusable alternative for the removal of chlorinated pesticides from aqueous media.
    Matched MeSH terms: Magnetics
  17. Noor Ashikin Mohd Rashid, Wan Nor Liza Wan Mahadi
    Sains Malaysiana, 2014;43:909-914.
    Evaluation of magnetic properties of electrical steel is vital in improving the quality of electrical machinery since it is used as magnetic cores for transformers, motors and generators. A double yoke single sheet tester (ssT) was modeled using two identical C-cores wound with copper wires at limb side in horizontal arrangement. The magnetic properties for electrical steels, grade M4 and M19 were tested under a frequency of 50 Hz with the current ranging from 02 to 2.4A. The effects of the sample dimension and anisotropy on magnetic measurements were investigated. Evaluation on specimen dimensions indicate that the non-uniformity of sample magnetization in overhang sample can attribute to the flux leakage between the yoke legs. The stray flux is also increased with the overhang sample. However, the so-called fit-in sample which is fitted nicely between the yoke end poles can minimize the effect of stray flux. One way ANOVA and T-test were used as statistical methods and executed at the 5% significance level. It is statistically proven that the magnetic properties of both magnetic materials are influenced by their anisotropy.
    Matched MeSH terms: Magnetics
  18. Norhisam, M., Roslan, M.K., Ishak, A., Hamidon, M.N.
    MyJurnal
    Visual inspection to locate metals embedded in walls or floors is impractical. Detection of these metals can only be done with a proper metal detection. Accordingly, the development of a magnetic imaging system based on giant magneto-resistance (GMR) sensors is presented for metal shape detection . This system is based on magnetic flux leakage testing (MFLT) principle for detecting the shape of ferromagnetic material specimens. The imaging system is constructed using 21 linear GMR sensors array as signals sensing unit (SSU). In this study, a few ferromagnetic SS400 mild steels specimens in various shapes are used as specimens. Image produced confirm system functionality in detecting and evaluating metal shapes.
    Matched MeSH terms: Magnetics
  19. Nurul Najian AB, Foo PC, Ismail N, Kim-Fatt L, Yean CY
    Mol Cell Probes, 2019 04;44:63-68.
    PMID: 30876924 DOI: 10.1016/j.mcp.2019.03.001
    This study highlighted the performance of the developed integrated loop-mediated isothermal amplification (LAMP) coupled with a colorimetric DNA-based magnetogenosensor. The biosensor operates through a DNA hybridization system in which a specific designed probe captures the target LAMP amplicons. We demonstrated the magnetogenosensor assay by detecting pathogenic Leptospira, which causes leptospirosis. The color change of the assay from brown to blue indicated a positive result, whereas a negative result was indicated by the assay maintaining its brown color. The DNA biosensor was able to detect DNA at a concentration as low as 200 fg/μl, which is equivalent to 80 genomes/reaction. The specificity of the biosensor assay was 100% when it was evaluated with 172 bacterial strains. An integrated LAMP and probe-specific magnetogenosensor was successfully developed, promising simple and rapid visual detection in clinical diagnostics and service as a point-of-care device.
    Matched MeSH terms: Magnetics/methods*
  20. Ooi DJ, Dzulkurnain A, Othman RY, Lim SH, Harikrishna JA
    J Virol Methods, 2006 Sep;136(1-2):160-5.
    PMID: 16781785
    A modified method for the rapid isolation of specific ligands to whole virus particles is described. Biopanning against cymbidium mosaic virus was carried out with a commercial 12-mer random peptide display library. A solution phase panning method was devised using streptavidin-coated superparamagnetic beads. The solution based panning method was more efficient than conventional immobilized target panning when using whole viral particles of cymbidium mosaic virus as a target. Enzyme-linked immunosorbent assay of cymbidium mosaic virus-binding peptides isolated from the library identified seven peptides with affinity for cymbidium mosaic virus and one peptide which was specific to cymbidium mosaic virus and had no significant binding to odontoglossum ringspot virus. This method should have broad application for the screening of whole viral particles towards the rapid development of diagnostic reagents without the requirement for cloning and expression of single antigens.
    Matched MeSH terms: Magnetics*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links