Displaying publications 41 - 60 of 72 in total

Abstract:
Sort:
  1. James V, Samuel J, Kee CY, Ong GY
    Ultrasound J, 2020 Dec 03;12(1):51.
    PMID: 33270182 DOI: 10.1186/s13089-020-00199-y
    BACKGROUND: The presence of intra-abdominal calcification in the pediatric population can be due to a wide range of conditions. Calcification in the abdomen can be seen in normal or abnormal anatomical structures. In some patients, abnormal calcification points towards the pathology; whereas in others, calcification itself is the pathology. After a thorough history and clinical examination, point-of-care ultrasound (POCUS) would complement the assessment of acute abdominal pain, based on the list of differentials generated as per the abdominal region. The main objective of this article is to review commonly encountered causes of intra-abdominal calcifications in the pediatric population and help in clinical decision-making in a Pediatric Emergency Department.

    CASE PRESENTATION: We describe a series of pediatric patients who presented to the Pediatric Emergency Department with acute abdominal pain, in whom point-of-care ultrasound helped expedite the diagnosis by identifying varying types of calcification and associated sonological findings. For children who present to the Pediatric Emergency Department with significant abdominal pain, a rapid distinction between emergencies and non-emergencies is vital to decrease morbidity and mortality.

    CONCLUSIONS: In a child presenting to the Pediatric Emergency Department with abdominal pain, POCUS and the findings of calcifications can narrow or expand the differential diagnosis when integrated with history and physical exam, to a specific anatomic structure. Integrating these findings with additional sonological findings of an underlying pathology might raise sufficient concerns in the emergency physicians to warrant further investigations for the patient in the form of a formal radiological ultrasound and assist in the patient's early disposition. The use of POCUS might also help to categorize the type of calcification to one of the four main categories of intra-abdominal calcifications, namely concretions, conduit wall calcification, cyst wall calcification, and solid mass-type calcification. POCUS used thoughtfully can give a diagnosis and expand differential diagnosis, reduce cognitive bias, and reduce physician mental load. By integrating the use of POCUS with the history and clinical findings, it will be possible to expedite the management in children who present to the Pediatric Emergency Department with acute abdominal pain.

    Matched MeSH terms: Point-of-Care Systems
  2. James V, Kee CY, Ong GY
    J Emerg Med, 2019 Apr;56(4):421-425.
    PMID: 30638645 DOI: 10.1016/j.jemermed.2018.12.015
    BACKGROUND: Point-of-care ultrasonography (POCUS) is increasingly used for both diagnostic and guided procedures. Increasingly, POCUS has been used for identification of pneumonia and to assist in the differentiation of pleural effusions, as well as to guide thoracentesis. As such, there is a need for training with ideally high-fidelity lung ultrasound phantoms to ensure ultrasound proficiency and procedural competency. Unfortunately, most commercial ultrasound phantoms remain expensive and may have limited fidelity.

    OBJECTIVE: Our aim was to create and describe a homemade, high-fidelity ultrasound phantom model for demonstrating pneumonia with pleural effusions for teaching purposes.

    DISCUSSION: An ultrasound phantom was constructed using a water-filled latex glove with a sliver of meat in it, covered over by a palm-sized piece of meat (skin and ribs are optional to increase ultrasonographic details and realism). This would appear like parapneumonic effusions with organized pneumonia under ultrasound examination. Creamer (or talc) can be added to the water in the glove to simulate empyema. The model can also be used to teach simple effusions and for ultrasound-guided thoracentesis and in clinical decision making.

    CONCLUSIONS: Easily prepared, homemade high-fidelity ultrasound phantom models for instructions on identification of pleural effusions and ultrasound-guided pleural tap of parapneumonic effusion were made.

    Matched MeSH terms: Point-of-Care Systems
  3. Sakulchit T, Ngu L, Chor YK, Ong GY
    Cureus, 2021 Mar 08;13(3):e13760.
    PMID: 33842136 DOI: 10.7759/cureus.13760
    Melioidosis is an infectious disease most commonly found in places with tropical climates. Definitive diagnosis can be confirmed by culture or pathological results of blood or infected organ. However, imaging study is helpful in providing early provisional diagnosis and guiding therapy. Point-of-care ultrasound can be currently performed bedside by non-radiological staff such as emergency physicians or intensivists. We present the case of a pediatric patient who got diagnosed with melioidosis after detection of multiple splenic and hepatic abscesses by point-of-care ultrasound, leading to early diagnosis and appropriate empirical antibiotic selection, resulting in good treatment outcome.
    Matched MeSH terms: Point-of-Care Systems
  4. Ong YN, James V, Lau KS, Chor YK, Ong GY
    Pediatr Emerg Care, 2022 Apr 01;38(4):183-186.
    PMID: 34608058 DOI: 10.1097/PEC.0000000000002555
    Abdominal pain is one of the most common presenting complaints encountered in the pediatric emergency department. The use of point-of-care ultrasonography by emergency physicians has been shown to expedite the diagnosis of a large variety of conditions and can be used to accurately identify intra-abdominal pathology in children. We describe the case of a pediatric patient who presented to the pediatric emergency department with acute abdominal pain, in whom point-of-care ultrasonography helped expedite the diagnosis of acute portal vein thrombosis and liver abscess.
    Matched MeSH terms: Point-of-Care Systems*
  5. Lim HJ, Saha T, Tey BT, Tan WS, Ooi CW
    Biosens Bioelectron, 2020 Nov 15;168:112513.
    PMID: 32889395 DOI: 10.1016/j.bios.2020.112513
    Infectious diseases are the ever-present threats to public health and the global economy. Accurate and timely diagnosis is crucial to impede the progression of a disease and break the chain of transmission. Conventional diagnostic techniques are typically time-consuming and costly, making them inefficient for early diagnosis of infections and inconvenient for use at the point of care. Developments of sensitive, rapid, and affordable diagnostic methods are necessary to improve the clinical management of infectious diseases. Quartz crystal microbalance (QCM) systems have emerged as a robust biosensing platform due to their label-free mechanism, which allows the detection and quantification of a wide range of biomolecules. The high sensitivity and short detection time offered by QCM-based biosensors are attractive for the early detection of infections and the routine monitoring of disease progression. Herein, the strategies employed in QCM-based biosensors for the detection of infectious diseases are extensively reviewed, with a focus on prevalent diseases for which improved diagnostic techniques are in high demand. The challenges to the clinical application of QCM-based biosensors are highlighted, along with an outline of the future scope of research in QCM-based diagnostics.
    Matched MeSH terms: Point-of-Care Systems
  6. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
    Matched MeSH terms: Point-of-Care Systems
  7. William T, Parameswaran U, Lee WK, Yeo TW, Anstey NM, Ralph AP
    BMC Infect Dis, 2015;15:32.
    PMID: 25636334 DOI: 10.1186/s12879-015-0758-6
    BACKGROUND: Tuberculosis (TB) is generally well controlled in Malaysia, but remains an important problem in the nation's eastern states. In order to better understand factors contributing to high TB rates in the eastern state of Sabah, our aims were to describe characteristics of patients with TB at a large outpatient clinic, and determine the prevalence of HIV co-infection. Additionally, we sought to test sensitivity and specificity of the locally-available point-of-care HIV test kits.
    METHODS: We enrolled consenting adults with smear-positive pulmonary TB for a 2-year period at Luyang Clinic, Kota Kinabalu, Malaysia. Participants were questioned about ethnicity, smoking, prior TB, disease duration, symptoms and comorbidities. Chest radiographs were scored using a previously devised tool. HIV was tested after counselling using 2 point-of-care tests for each patient: the test routinely in use at the TB clinic (either Advanced Quality™ Rapid Anti-HIV 1&2, FACTS anti-HIV 1/2 RAPID or HIV (1 + 2) Antibody Colloidal Gold), and a comparator test (Abbott Determine™ HIV-1/2, Inverness Medical). Positive tests were confirmed by enzyme immunoassay (EIA), particle agglutination and line immunoassay.
    RESULTS: 176 participants were enrolled; 59 (33.5%) were non-Malaysians and 104 (59.1%) were male. Smoking rates were high (81/104 males, 77.9%), most had cavitary disease (51/145, 64.8%), and 81/176 (46.0%) had haemoptysis. The median period of symptoms prior to treatment onset was 8 weeks. Diabetes was present in 12. People with diabetes or other comorbidities had less severe TB, suggesting different healthcare seeking behaviours in this group. All participants consented to HIV testing: three (1.7%) were positive according to Determine™ and EIA, but one of these tested negative on the point-of-care test available at the clinic (Advanced Quality™ Rapid Anti-HIV 1&2). The low number of positive tests and changes in locally-available test type meant that accurate estimates of sensitivity and specificity were not possible.
    CONCLUSION: Patients had advanced disease at diagnosis, long diagnostic delays, low HIV co-infection rates, high smoking rates among males, and migrants may be over-represented. These findings provide important insights to guide local TB control efforts. Caution is required in using some point-of-care HIV tests, and ongoing quality control measures are of major importance.
    Study site: Klinik Kesihatan Luyang (Tuberculosis Clinic), Kota Kinabalu, Sabah, Malaysia,
    Matched MeSH terms: Point-of-Care Systems
  8. Iqhbal M, Noor JM, Karim NA, Ismail I, Sanib H, Mokhtar MA, et al.
    Sultan Qaboos Univ Med J, 2018 May;18(2):e219-e222.
    PMID: 30210855 DOI: 10.18295/squmj.2018.18.02.017
    The use of ultrasonography in acute and critical care medicine is becoming increasingly common. However, use of an airway ultrasound as an adjunct to determine the type of intervention needed and assess complications is not common practice. We report a 56-year-old male who presented to the Emergency Department of the Sungai Buloh Hospital, Selangor, Malaysia, in 2015 with hoarseness, stridor and impending respiratory failure. A point-of-care ultrasound performed to assess the neck and vocal cords indicated a heterogeneous echogenic mass in the larynx, thus ruling out a cricothyroidotomy. The patient was therefore referred for an emergency tracheostomy. This case highlights the importance of point-of-care airway ultrasonography in the assessment of patients with stridor. This imaging technique not only helps to detect the cause of the stridor, but also to determine the feasibility of a cricothyroidotomy in emergency cases.
    Matched MeSH terms: Point-of-Care Systems*
  9. Chong ZL, Soe HJ, Ismail AA, Mahboob T, Chandramathi S, Sekaran SD
    Biosensors (Basel), 2021 Apr 22;11(5).
    PMID: 33921935 DOI: 10.3390/bios11050129
    Dengue is a major threat to public health globally. While point-of-care diagnosis of acute/recent dengue is available to reduce its mortality, a lack of rapid and accurate testing for the detection of previous dengue remains a hurdle in expanding dengue seroepidemiological surveys to inform its prevention, especially vaccination, to reduce dengue morbidity. This study evaluated ViroTrack Dengue Serostate, a biosensors-based semi-quantitative anti-dengue IgG (immunoglobulin G) immuno-magnetic agglutination assay for the diagnosis of previous and recent dengue in a single test. Blood samples were obtained from 484 healthy participants recruited randomly from two communities in Petaling district, Selangor, Malaysia. The reference tests were Panbio Dengue IgG indirect and capture enzyme-linked immunosorbent assays, in-house hemagglutination inhibition assay, and focus reduction neutralization test. Dengue Serostate had a sensitivity and specificity of 91.1% (95%CI 87.8-93.8) and 91.1% (95%CI 83.8-95.8) for the diagnosis of previous dengue, and 90.2% (95%CI 76.9-97.3) and 93.2% (95%CI 90.5-95.4) for the diagnosis of recent dengue, respectively. Its positive predictive value of 97.5% (95%CI 95.3-98.8) would prevent most dengue-naïve individuals from being vaccinated. ViroTrack Dengue Serostate's good point-of-care diagnostic accuracy can ease the conduct of dengue serosurveys to inform dengue vaccination strategy and facilitate pre-vaccination screening to ensure safety.
    Matched MeSH terms: Point-of-Care Systems
  10. Balakrishnan P, Saravanan S, Vignesh R, Shankar EM
    Indian J Med Res, 2023 Nov 01;158(5&6):447-450.
    PMID: 38063301 DOI: 10.4103/ijmr.ijmr_1616_23
    Matched MeSH terms: Point-of-Care Systems*
  11. Foster D, Cox-Singh J, Mohamad DS, Krishna S, Chin PP, Singh B
    Malar J, 2014;13:60.
    PMID: 24548805 DOI: 10.1186/1475-2875-13-60
    Plasmodium knowlesi, a malaria parasite of Southeast Asian macaques, infects humans and can cause fatal malaria. It is difficult to diagnose by microscopy because of morphological similarity to Plasmodium malariae. Nested PCR assay is the most accurate method to distinguish P. knowlesi from other Plasmodium species but is not cost effective in resource-poor settings. Rapid diagnostic tests (RDTs) are recommended for settings where malaria is prevalent. In this study, the effectiveness of three RDTs in detecting P. knowlesi from fresh and frozen patient blood samples was evaluated.
    Matched MeSH terms: Point-of-Care Systems*
  12. Thanimalai S, Shafie AA, Hassali MA, Sinnadurai J
    Int J Clin Pharm, 2013 Oct;35(5):736-43.
    PMID: 23715759 DOI: 10.1007/s11096-013-9796-6
    BACKGROUNDS: Limited evidence is available regarding pharmacist managed anticoagulation clinic in the Southeast Asian region where there is marked difference in terms of care model, genetic composition and patient demographics.

    OBJECTIVES: This study aimed at comparing the anticoagulation clinic managed by the pharmacist with physician advisory and the usual medical care provided in Kuala Lumpur Hospital (KLH) in terms of anticoagulation control and adverse outcomes.

    SETTING: A 2,302 bedded government tertiary referral hospital in Malaysia.

    METHODS: A 6-month retrospective cohort study of the effectiveness of two models of anticoagulation care, the pharmacist managed anticoagulation clinic which is known as warfarin medication therapy adherence clinic (WMTAC) and usual medical clinic (UMC) in KLH was conducted, where a random number generator was used to recruit patients. The UMC patients received standard medical care where they are managed by rotational medical officers in the physicians' clinic. As for the WMTAC with physician advisory, the pharmacist will counsel and review the patients internationalised normalization ratio at each clinic visit and also adjust the patients' warfarin dose accordingly. Patients are referred to physicians if immediate attention is required.

    MAIN OUTCOME MEASURE: The main therapeutic outcome is time in therapeutic range (TTR) both actual and expanded TTR and thromboembolic and bleeding complications.

    RESULTS: Each of the WMTAC and usual medical care recruited 92 patients, which totals to 184 patients. The patient demographics in terms of age, race and indication of treatment were comparable. At the end of the 6 months follow-up, patients in the WMTAC group had significantly higher actual-TTR (65.1 vs. 48.3 %; p < 0.05) compared to those in usual medical care group. Rates of admission were 6.5 versus 28.2 events per 100 person-years for the WMTAC and UMC groups, respectively. Though the bleeding incidences were not significantly different, it was reduced.

    CONCLUSIONS: These findings will impact local warfarin patient management services and policies because there was no available evidence supporting the role of pharmacists in the management of warfarin patients prior to this study.
    Matched MeSH terms: Point-of-Care Systems
  13. Peyman M, Tai LY, Khaw KW, Ng CM, Win MM, Subrayan V
    Int Ophthalmol, 2015 Oct;35(5):651-5.
    PMID: 25189684 DOI: 10.1007/s10792-014-9989-6
    To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.
    Matched MeSH terms: Point-of-Care Systems*
  14. Ang KM, Yeo LY, Hung YM, Tan MK
    Lab Chip, 2016 09 21;16(18):3503-14.
    PMID: 27502324 DOI: 10.1039/c6lc00780e
    The deposition of a thin graphene film atop a chip scale piezoelectric substrate on which surface acoustic waves are excited is observed to enhance its performance for fluid transport and manipulation considerably, which can be exploited to achieve further efficiency gains in these devices. Such gains can then enable complete integration and miniaturization for true portability for a variety of microfluidic applications across drug delivery, biosensing and point-of-care diagnostics, among others, where field-use, point-of-collection or point-of-care functionality is desired. In addition to a first demonstration of vibration-induced molecular transport in graphene films, we show that the coupling of the surface acoustic wave gives rise to antisymmetric Lamb waves in the film which enhance molecular diffusion and hence the flow through the interstitial layers that make up the film. Above a critical input power, the strong substrate vibration displacement can also force the molecules out of the graphene film to form a thin fluid layer, which subsequently destabilizes and breaks up to form a mist of micron dimension aerosol droplets. We provide physical insight into this coupling through a simple numerical model, verified through experiments, and show several-fold improvement in the rate of fluid transport through the film, and up to 55% enhancement in the rate of fluid atomization from the film using this simple method.
    Matched MeSH terms: Point-of-Care Systems
  15. Fathil MF, Md Arshad MK, Gopinath SC, Hashim U, Adzhri R, Ayub RM, et al.
    Biosens Bioelectron, 2015 Aug 15;70:209-20.
    PMID: 25841117 DOI: 10.1016/j.bios.2015.03.037
    Acute myocardial infarction or myocardial infarction (MI) is a major health problem, due to diminished flow of blood to the heart, leads to higher rates of mortality and morbidity. Data from World Health Organization (WHO) accounted 30% of global death annually and expected more than 23 million die annually by 2030. This fatal effects trigger the need of appropriate biomarkers for early diagnosis, thus countermeasure can be taken. At the moment, the most specific markers for cardiac injury are cardiac troponin I (cTnI) and cardiac troponin T (cTnT) which have been considered as 'gold standard'. Due to higher specificity, determination of the level of cardiac troponins became a predominant indicator for MI. Several ways of diagnostics have been formulated, which include enzyme-linked immunosorbent assay, chemiluminescent, fluoro-immunoassays, electrical detections, surface plasmon resonance, and colorimetric protein assay. This review represents and elucidates the strategies, methods and detection levels involved in these diagnostics on cardiac superior biomarkers. The advancement, sensitivity, and limitations of each method are also discussed. In addition, it concludes with a discussion on the point-of care (POC) assay for a fast, accurate and ability of handling small sample measurement of cardiac biomarker.
    Matched MeSH terms: Point-of-Care Systems*
  16. Citartan M, Tang TH
    Talanta, 2019 Jul 01;199:556-566.
    PMID: 30952298 DOI: 10.1016/j.talanta.2019.02.066
    Aptamers are nucleic acid-based molecular recognition elements that are specific and have high binding affinity against their respective targets. On account of their target recognition capacity, aptamers are widely utilized in a number of applications including diagnostics. This review aims to highlight the recent developments of aptasensors expedient for point-of-care (POC) diagnostics. Significant focus is given on the primary assay formats of aptamers such as fluorescence, electrochemical, surface plasmon resonance (SPR) and colorimetric assays. A potpourri of platforms such as paper-based device, lateral flow assay, portable electrodes, portable SPR and smart phones expedient for point-of-care (POC) diagnostics are discussed. Emphasis is also given on the technicalities and assay configurations associated with the sensors.
    Matched MeSH terms: Point-of-Care Systems*
  17. Teng CL
    Malays Fam Physician, 2014;9(2):18-25.
    PMID: 25893067 MyJurnal
    This review highlights the high prevalence of antibiotic use for upper respiratory tract infections (URTIs) in a larger part of the Asia-Pacific region. Since URTIs are one of the common reasons for primary care consultations in this region, inappropriate use of antibiotic in both quantity and drug choice has greatly influenced the development of antibiotic resistance. Notwithstanding the paucity of Asia-Pacific data on the above issues, the available information suggests urgent actions needed to be taken to promote judicious antibiotic use at the point-of-care through a multi- pronged approach targeting the patients/consumers (or parents), healthcare providers and health care systems.
    Matched MeSH terms: Point-of-Care Systems
  18. Teng CL
    MyJurnal
    In the developing world, clinical knowledge management in primary care has a long way to go. Clinical decision support systems, despite its promise to revolutionise healthcare, is slow in its implementation due to the lack of financial investment in information technology. Point-of-care resources, such as comprehensive electronic textbooks delivered via the web or mobile devices, have yet to be fully utilised by the healthcare organisation or individual clinicians. Increasing amount of applicable knowledge of good quality (e.g. clinical practice guidelines and other pre-appraised resources) are now available via the internet. The policy makers and clinicians need to be more informed about the potential benefits and
    limitations of these new tools and resources and make the necessary budgetary provision and learn how best to harness them for patient care.
    Matched MeSH terms: Point-of-Care Systems
  19. Osman A, Fong CP, Wahab SFA, Panebianco N, Teran F
    J Emerg Med, 2020 Sep;59(3):418-423.
    PMID: 32591302 DOI: 10.1016/j.jemermed.2020.05.003
    BACKGROUND: Although surface sonography has become an essential diagnostic tool in the evaluation of trauma patients, important limitations of this modality include the evaluation of retroperitoneal hemorrhage and mediastinal pathology, such as blunt traumatic aortic injuries (BTAI). As in other emergency applications where surface sonography can't provide the information needed, focused transesophageal echocardiography (TEE) may represent a valuable diagnostic tool in the evaluation of hemodynamically unstable trauma patients with suspected thoracic pathology such as BTAI.

    CASE SERIES: We present a series of five cases that illustrate the diagnostic value of emergency physician-performed resuscitative TEE in the diagnosis of BTAI in patients presenting with blunt thoracic trauma. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: As the use of point-of-care TEE during resuscitation continues to expand in emergency medicine, the evaluation of patients with BTAI represents a novel application where this emerging modality can allow early diagnosis of these injuries in hemodynamically unstable patients.

    Matched MeSH terms: Point-of-Care Systems
  20. Kho SS, Chan SK, Yong MC, Cheah HM, Lee YG, Tie ST
    Respir Investig, 2020 Sep;58(5):367-375.
    PMID: 32107195 DOI: 10.1016/j.resinv.2020.01.004
    BACKGROUND: Tuberculous pleural effusions (TBEs) and parapneumonic pleural effusion (PPEs) have similar clinical presentations and fluid biochemistry. A pleural biopsy is usually required to diagnose TBE but complete fluid evacuation may not be necessary, contrasting with complicated PPE (CPPE). A point-of-care test that distinguishes between TBE and CPPE enables the appropriate procedures to be performed during the initial diagnostic thoracentesis. Lactate is a metabolic product measurable by a blood-gas analyzer. This study measured pleural fluid (Pf) lactate levels in TBE and compared them with those in PPE/CPPE. We hypothesized that Pf lactate would be significantly higher in PPE because of active metabolic activities than in TBE which is driven by delayed hypersensitivity.

    METHODS: All patients undergoing an initial diagnostic thoracentesis over 18 months with Pf lactate measured using a calibrated point-of-care blood gas analyzer were assessed.

    RESULTS: The diagnoses of the enrolled patients (n = 170) included TBE (n = 49), PPE (n = 47), malignancy (n = 63), and transudate (n = 11). Pf lactate level in TBE, median 3.70 (inter-quartile range 2.65-4.90) mmol/l, was significantly lower than in PPE and CPPE. In the subgroup of TBE and CPPE patients whose initial Pf pH and glucose could suggest either condition, Pf lactate was significantly higher in those with CPPE. Pf lactate (cutoff ≥7.25 mmol/l) had a sensitivity of 79.3%, specificity 100%, positive predictive value 100%, and negative predictive value 89.1% for discriminating CPPE from TBE (area under the curve 0.947, p Point-of-care Pf lactate measurements may have practical value in early separation of TBE or CPPE during initial thoracentesis, and warrants further investigation.

    Matched MeSH terms: Point-of-Care Systems*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links