Methods: One hundred and twenty-five disk samples were prepared from a new rice husk-based composite and four other conventional methacrylate-based light-cured composites of shade A2. The samples were immersed in four commonly consumed beverages: coco-based drink, kopi, Chinese tea, and teh tarik for four weeks. The color measurements were carried out every week using the reflectance spectrophotometer according to the CIE L
∗
a
∗
b
∗
color system. Color changes of samples (ΔE) in each week were calculated. Statistical analysis was carried out by performing a mixed ANOVA and Tukey's post hoc test in order to analyse the differences in ΔE.
Results: The findings revealed a statistically significant difference of ΔE reading (p < 0.05) among all composites immersed in all four beverages after four weeks. Rice husk composites exhibited lesser color stability as compared to Ceram.X One Universal (p < 0.001) and G-aenial Universal Flo (p < 0.001) but showed higher color stability compared to Solare-X (p < 0.001) and Neofil (p < 0.001). Coffee and Chinese tea had the most significant impact on color changes (p < 0.05) observed in all composites over four weeks of study.
Conclusion: Rice husk composite showed acceptable color stability. It can be considered as an alternative to conventional composites due to its eco-friendly properties.
METHODS: The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test.
RESULTS: FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F𝑐𝑟𝑖𝑡, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.
METHODS: A cross-sectional randomized intervention study over 12 months' duration was conducted in university hospital simulation lab. ACLS-certified medical doctors were assigned to run 2 standardized simulated resuscitation code as RTL from a head-end position (HEP) and leg-end position (LEP). They were evaluated on leadership qualities including situational attentiveness (SA), errors detection (ED), and decision making (DM) using a standardized validated resuscitation-code-checklist (RCC). Performance was assessed live by 2 independent raters and was simultaneously recorded. RTL self-perceived performance was compared to measured performance.
RESULTS: Thirty-four participants completed the study. Mean marks for SA were 3.74 (SD ± 0.96) at HEP and 3.54 (SD ± 0.92) at LEP, P = .48. Mean marks for ED were 2.43 (SD ± 1.24) at HEP and 2.21 (SD ± 1.14) at LEP, P = .40. Mean marks for DM were 4.53 (SD ± 0.98) at HEP and 4.47 (SD ± 0.73) at LEP, P = .70. The mean total marks were 10.69 (SD ± 1.82) versus 10.22 (SD ± 1.93) at HEP and LEP respectively, P = .29 which shows no significance difference in all parameters. Twenty-four participants (71%) preferred LEP for the following reasons, better visualization (75% of participants); more room for movement (12.5% of participants); and better communication (12.5% of participants). RTL's perceived performance did not correlate with actual performance CONCLUSION:: The physical position either HEP or LEP appears to have no influence on performance of RTL in simulated cardiac resuscitation. RTL should be aware of the advantages and limitations of each position.
MATERIAL AND METHODS: Transmission and field emission scanning electron microscopy (TEM and FESEM) were used for the characterisation of CaCO3 nanocrystals. Cytotoxicity and genotoxic effect of calcium carbonate nanocrystals in cultured mouse embryonic fibroblast NIH 3T3 cell line using various bioassays including MTT, and Neutral red/Trypan blue double-staining assays. LDH, BrdU and reactive oxygen species were used for toxicity analysis. Cellular morphology was examined by scanning electron microscopy (SEM) and confocal fluorescence microscope.
RESULTS: The outcome of the analyses revealed a clear rod-shaped aragonite polymorph of calcium carbonate nanocrystal. The analysed cytotoxic and genotoxicity of CaCO3 nanocrystal on NIH 3T3 cells using different bioassays revealed no significance differences as compared to control. A slight decrease in cell viability was noticed when the cells were exposed to higher concentrations of 200 to 400 µg/ml, while increase in ROS generation and LDH released at 200 and 400 µg/ml was observed.
CONCLUSIONS: The study has shown that CaCO3 nanocrystal is biocompatible and non toxic to NIH 3T3 fibroblast cells. The analysed results offer a promising potential of CaCO3 nanocrystal for the development of intracellular drugs, genes and other macromolecule delivery systems.