AIM: This study aimed to evaluate the ultrasound method and its agreement with the endometrium cytology method, which is used to diagnose cytological endometritis in beef cows. Moreover, we determined which method has higher sensitivity and specificity at 4 and 5 weeks postpartum.
MATERIALS AND METHODS: The study was conducted 20-35 days postpartum. A total of 53 clinically healthy beef cows (28 Brangus and 25 Kedah-Kelantan breeds) from three beef farms were obtained. All cows were evaluated at 4 and 5 weeks postpartum, using ultrasound and cytobrush endometrial examination methods to diagnose cytological endometritis.
RESULTS: Endometrial cytology result showed that 11.3% (6/53) and 9.4% (5/53) of the cows exhibited cytological endometritis 4 and 5 weeks postpartum, respectively. A weak-to-moderate agreement found between the diagnostic methods (k=0.29 - 0.50; p<0.01 and k=0.38 - 0.49) at 4 and 5 weeks postpartum respectively.
CONCLUSION: The percentage of beef cows that were positive to cytological endometritis was low (polymorphonuclear cells, ≥8%) at 4 and 5 weeks postpartum. Results showed that the ultrasound method is useful and practical for diagnosing endometritis 4 and 5 weeks postpartum. This method exhibited 60% sensitivity, 93.8% specificity, and a 0.50 kappa value, especially when presence of intrauterine fluids and measurement of cervix diameter used in combination.
METHODS: The imaging performance of the camera system was assessed quantitatively and qualitatively at different source depths, source to collimator distances (SCD), activity levels, acquisition times and source separations, utilising bespoke phantoms.
RESULTS: The system sensitivity and spatial resolution of the HGC for 125I were 0.41 cps/MBq (at SCD 48 mm) and 1.53 ± 0.23 mm (at SCD 10 mm) respectively. The camera was able to detect the 125I seed at a SCD of 63 mm (with no scattering material in place) in images recorded within a 1-min acquisition time. The detection of the seeds beneath scattering material (simulating deep-seated tumours) was limited to depths of less than 20 mm beneath the skin surface with a SCD of 63 mm and seed activity of 2.43 MBq. Subjective assessments of the hybrid images acquired showed the capability of the HGC for localising the 125I seeds.
CONCLUSION: This preliminary ex vivo study demonstrates that the HGC is capable of detecting 125I seeds and could be a useful tool in radioactive seed localisation with the added benefit of providing hybrid optical γ images for guiding breast conserving surgery.
ADVANCES IN KNOWLEDGE: The SFOV HGC could provide high resolution fused optical-gamma images of 125I radioactive seeds indicating the potential use in intraoperative surgical procedure such as RSL.
METHODS: This was a meta-analysis of diagnostic test accuracy. Relevant studies that evaluated the diagnostic performance of RDTs and microscopy for detection of asymptomatic malaria were searched in health-related electronic databases. The methodological quality of the studies included was assessed using the QUADAS-2 tool.
RESULTS: Ten studies assessing RDT and/or microscopy were identified. The diagnostic accuracies in all these studies were verified by PCR. Overall, the pooled sensitivities of RDT, as well as microscopy for detection of any malaria parasites in asymptomatic participants, were low, while their pooled specificities were almost ideal. For the detection of Plasmodium falciparum, pooled sensitivity by RDT (59%, 95%CI:16-91%) or microscopy (55%, 95%CI: 25-82%) were almost comparable. For detection of Plasmodium vivax, pooled sensitivity of RDT (51%, 95% CI:7-94%) had also the comparable accuracy of microscopy (54%, 95%CI,11-92%). Of note are the wide range of sensitivity and specificity.
CONCLUSION: The findings of this meta-analysis suggest that RDTs and microscopy have limited sensitivity and are inappropriate for the detection of asymptomatic Plasmodium infections. Other methods including a combination of PCR-based strategies, Loop-Mediated Isothermal Amplification (LAMP) technique must be considered to target these infections, in order to achieve malaria elimination. However, more data is needed for the wide acceptance and feasibility of these approaches. Studies to explore the role of asymptomatic and sub-patent infections in the transmission of malaria are of critical importance and are recommended.
METHODS: It was a cross-sectional study carried out at Universiti Kebangsaan Malaysia Medical Centre (UKMMC), Malaysia. Records of patients with focal thyroid nodules on ultrasound (US) for which US-guided fine needle aspiration cytology (FNAC) was performed and pathology results were available, from January 2014 to May 2016 were selected for review. Correlation of the U Classification with pathology results was assessed. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, predictive value, negative predictive value and accuracy were calculated in a conservative and non-conservative method. The threshold for statistical performance was set at 0.05. Each sonographic feature was also compared with its pathology results.
RESULTS: A total of 91 patients with 104 nodules were eligible. 12 nodules out of 104 (11.5%) were malignant. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value, negative predictive value and accuracy were 100%, 91.3%, 11.5, 0.0, 60%, 100% and 92.3%, and 100%, 91.4%, 11.7%, 0.0, 78.6%, 100% and 93.5%, for the non-conservative and conservative method of calculations respectively.
CONCLUSION: The U Classification is reliable in predicting thyroid malignancy. More evidence is nevertheless necessary for widespread adaptation and use.
METHODS: This was a meta-analysis of diagnostic accuracy. Relevant studies that assessed the diagnostic performance of LAMP for the detection of malaria in pregnancy were searched in health-related electronic databases including PubMed, Ovid, and Google Scholar. The methodological quality of the studies included was evaluated using the QUADAS-2 tool.
RESULTS: Of the 372 studies identified, eight studies involving 2999 pregnant women in five endemic countries that assessed the accuracy of LAMP were identified. With three types of PCR as reference tests, the pooled sensitivity of LAMP was 91% (95%CI 67-98%) and pooled specificity was 99% (95%CI 83-100%, 4 studies), and the negative likelihood ratio was 9% (2-40%). Caution is needed in the interpretation as there was substantial between-study heterogeneity (I2: 80%), and a low probability that a person without infection is tested negative. With microscopy as a reference, the pooled sensitivity of LAMP was 95% (95%CI 26-100%) and pooled specificity was 100% (95%CI 94-100%, 4 studies). There was a wide range of sensitivity and substantial between-study heterogeneity (I2: 83.5-98.4%). To investigate the source of heterogeneity, a meta-regression analysis was performed with covariates. Of these potential confounding factors, reference test (p: 0.03) and study design (p:0.03) had affected the diagnostic accuracy of LAMP in malaria in pregnancy. Overall, there was a low certainty of the evidence in accuracy estimates.
CONCLUSION: The findings suggest that LAMP is more sensitive than traditional tests used at facilities, but the utility of detecting and treating these low-density infections is not well understood. Due to the limited number of studies with bias in their methodological quality, variation in the study design, and different types of reference tests further research is likely to change the estimate. Well-conceived large prospective studies with blinding of the index test results are recommenced.