Displaying publications 61 - 80 of 279 in total

Abstract:
Sort:
  1. Daneshjoo A, Rahnama N, Mokhtar AH, Yusof A
    J Hum Kinet, 2013 Mar;36:45-53.
    PMID: 23717354 DOI: 10.2478/hukin-2013-0005
    This study investigated bilateral and unilateral asymmetries of strength and flexibility in male young professional soccer players. Thirty-six soccer players (age: 18.9 ± 1.4 years) participated in this study. A Biodex Isokinetic Dynamometer was used to assess the hamstring and quadriceps strength at selected speeds of 60°/s, 180°/s and 300°/s. Hip joint flexibility was measured using a goniometer. No difference was observed in conventional strength ratio, dynamic control ratio and fast/slow speed ratio between the dominant and non-dominant legs (p>0.05). All but one of the players (97.2%) had musculoskeletal abnormality (bilateral imbalance > 10%) in one or more specific muscle groups. The dominant leg had greater hip joint flexibility compared with the non-dominant leg (108.8 ± 10.7° versus 104.6 ± 9.8°, respectively). The findings support the hypothesis that physical performance and movement pattern experienced during soccer playing may negatively change the balance of strength in both legs (bilateral strength balance), but not on the same leg of the young male professional soccer players. The results can be helpful for trainers and coaches to decide whether the players need to improve their balance and strength which in turn may prevent injury. It is suggested that in professional soccer training, quadriceps and hamstrings muscle strength, as well as hip joint flexibility should not be overlooked.
    Matched MeSH terms: Range of Motion, Articular
  2. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  3. Siow WM, Chin PL, Chia SL, Lo NN, Yeo SJ
    Clin Orthop Relat Res, 2013 May;471(5):1451-7.
    PMID: 23299954 DOI: 10.1007/s11999-012-2776-7
    There is marked racial disparity in TKA use rates, demographics, and outcomes between white and Afro-Caribbean Americans. Comparative studies of ethnicity in patients undergoing TKAs have been mostly in American populations with an underrepresentation of Asian groups. It is unclear whether these disparities exist in Chinese, Malays, and Indians.
    Matched MeSH terms: Range of Motion, Articular
  4. Shetty P
    Lancet, 2013 May 18;381(9879):1709-10.
    PMID: 23691551
    Matched MeSH terms: Motion Pictures as Topic*
  5. Ling XF, Peng X, Samman N
    J Oral Maxillofac Surg, 2013 Sep;71(9):1604-12.
    PMID: 23810616 DOI: 10.1016/j.joms.2013.03.006
    This study evaluated and compared the long-term donor-site morbidity of the free fibula flap with the deep circumflex iliac artery (DCIA) flap in maxillofacial reconstruction.
    Matched MeSH terms: Range of Motion, Articular/physiology
  6. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Range of Motion, Articular
  7. Makinejad MD, Abu Osman NA, Abu Bakar Wan Abas W, Bayat M
    Clinics (Sao Paulo), 2013 Sep;68(9):1180-8.
    PMID: 24141832 DOI: 10.6061/clinics/2013(09)02
    This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height.
    Matched MeSH terms: Range of Motion, Articular/physiology
  8. Wang C, Bea K, Zulkiflee O
    Malays Orthop J, 2013 Nov;7(3):18-20.
    PMID: 25674302 MyJurnal DOI: 10.5704/MOJ.1311.002
    Clavicle fracture is commonly treated conservatively. However uncommon complication can arise causing impingement. We report a patient who sustained distal clavicle fracture and was treated conservatively. However he developed persistent shoulder pain that affected his daily life. Shoulder impingement was diagnosed and arthroscopic subacromioclavicular decompression was done. Following early physiotherapy the early recovery was good with full range of motion of the shoulder.
    Matched MeSH terms: Range of Motion, Articular
  9. Fathurrahman L, Hajar AH, Sakinah DW, Nurhazwani Z, Ahmad J
    Pak J Biol Sci, 2013 Nov 15;16(22):1517-23.
    PMID: 24511694
    One of the main limitations of productivity in photobioreactor is the inefficient conversion of the available light into biomass. Photoautotrophic cells such as microalgae only absorb a small fraction of supplied illumination due to limitation of its photosystem's (PS) absorbing rate. However, phenomenon of Flashing Light Effect (FLE) allows microalgae to utilize strong light exceptionally through intermittent exposure. Exposure of strong light at correct frequency of light and dark photoperiod would allow two pigment-protein complexes, PSI and PSII to be at the equilibrium mid-point potential to allow efficient light conversion. Narrow range of optimum frequency is crucial since overexposure to strong light would injured photosynthetic apparatus whereas longer dark period would contributed to loss of biomass due to triacylglycerol metabolism. The behaviour of microalgae towards various illumination conditions of FLE was determined at batch Photobioreactor (PBR) by varying the aeration flow rate: 16.94, 33.14 and 49.28 mL sec(-1) which yield, respectively the light exposure time of 3.99, 1.71 and 1.1 seconds per cycle. Maximum cell density in FLE-PBR was significantly higher at the exponential phase as compared to the continuously illuminated culture (p = 5.62 x 10(-5), a = 0.05) under the flow rate of 25.07 mL sec(-1). Maximum cell density yield of FLE-PBR and continuously illuminated PBR was, respectively 3.1125 x 10(7) and 2.947 x 10(7) cells mL(-1). Utilization of FLE as an innovative solution to increase the efficiency of microalgae to convert light into chemical energy would revolutionize the microalgae culture, reduce the time for cultivation and produce higher maximum biomass density.
    Matched MeSH terms: Motion
  10. Teo PC, Kassim AY, Thevarajan K
    J Orthop Surg (Hong Kong), 2013 Dec;21(3):340-6.
    PMID: 24366797
    To propose a novel method to measure the neck shaft angle and anteversion of the femur using anteroposterior and 45-degree oblique radiographs.
    Matched MeSH terms: Range of Motion, Articular
  11. Ali F, Khan I, Samiulhaq, Shafie S
    PLoS One, 2013;8(6):e65223.
    PMID: 23840321 DOI: 10.1371/journal.pone.0065223
    The aim of this study is to present an exact analysis of combined effects of radiation and chemical reaction on the magnetohydrodynamic (MHD) free convection flow of an electrically conducting incompressible viscous fluid over an inclined plate embedded in a porous medium. The impulsively started plate with variable temperature and mass diffusion is considered. The dimensionless momentum equation coupled with the energy and mass diffusion equations are analytically solved using the Laplace transform method. Expressions for velocity, temperature and concentration fields are obtained. They satisfy all imposed initial and boundary conditions and can be reduced, as special cases, to some known solutions from the literature. Expressions for skin friction, Nusselt number and Sherwood number are also obtained. Finally, the effects of pertinent parameters on velocity, temperature and concentration profiles are graphically displayed whereas the variations in skin friction, Nusselt number and Sherwood number are shown through tables.
    Matched MeSH terms: Motion
  12. Rahman K, Ghani NA, Kamil AA, Mustafa A, Kabir Chowdhury MA
    PLoS One, 2013;8(5):e63503.
    PMID: 23691055 DOI: 10.1371/journal.pone.0063503
    Pedestrian movements are the consequence of several complex and stochastic facts. The modelling of pedestrian movements and the ability to predict the travel time are useful for evaluating the performance of a pedestrian facility. However, only a few studies can be found that incorporate the design of the facility, local pedestrian body dimensions, the delay experienced by the pedestrians, and level of service to the pedestrian movements. In this paper, a queuing based analytical model is developed as a function of relevant determinants and functional factors to predict the travel time on pedestrian facilities. The model can be used to assess the overall serving rate or performance of a facility layout and correlate it to the level of service that is possible to provide the pedestrians. It has also the ability to provide a clear suggestion on the designing and sizing of pedestrian facilities. The model is empirically validated and is found to be a robust tool to understand how well a particular walking facility makes possible comfort and convenient pedestrian movements. The sensitivity analysis is also performed to see the impact of some crucial parameters of the developed model on the performance of pedestrian facilities.
    Matched MeSH terms: Time and Motion Studies*
  13. Bachok N, Ishak A, Pop I
    PLoS One, 2013;8(4):e60766.
    PMID: 23577156 DOI: 10.1371/journal.pone.0060766
    The steady boundary layer flow of a viscous and incompressible fluid over a moving vertical flat plate in an external moving fluid with viscous dissipation is theoretically investigated. Using appropriate similarity variables, the governing system of partial differential equations is transformed into a system of ordinary (similarity) differential equations, which is then solved numerically using a Maple software. Results for the skin friction or shear stress coefficient, local Nusselt number, velocity and temperature profiles are presented for different values of the governing parameters. It is found that the set of the similarity equations has unique solutions, dual solutions or no solutions, depending on the values of the mixed convection parameter, the velocity ratio parameter and the Eckert number. The Eckert number significantly affects the surface shear stress as well as the heat transfer rate at the surface.
    Matched MeSH terms: Motion*
  14. Bong CH, Lau TL, Ghani AA
    Water Sci Technol, 2013;67(2):395-403.
    PMID: 23168641 DOI: 10.2166/wst.2012.580
    The current study aims to verify the existing equations for incipient motion for a rigid rectangular channel. Data from experimental work on incipient motion from a rectangular flume with two different widths, namely 0.3 and 0.6 m, were compared with the critical velocity value predicted by the equations of Novak & Nalluri and El-Zaemey. The equation by El-Zaemey performed better with an average discrepancy ratio value of 1.06 compared with the equation by Novak & Nalluri with an average discrepancy ratio value of 0.87. However, as the sediment deposit thickness increased, the equation by El-Zaemey became less accurate. A plot on the Shields Diagram using the experimental data had shown the significant effect of the sediment deposit thickness where, as the deposit becomes thicker, the dimensionless shear stress θ value also increased. A new equation had been proposed by incorporating the sediment deposit thickness. The new equation gave improved prediction with an average discrepancy ratio value of 1.02.
    Matched MeSH terms: Motion*
  15. Tham LK, Abu Osman NA, Wan Abas WA, Lim KS
    PLoS One, 2013;8(2):e55702.
    PMID: 23409022 DOI: 10.1371/journal.pone.0055702
    The deep tendon reflex assessments that are essential to the accurate diagnosis of neurological or neuromuscular disorders are conducted subjectively in clinical neurology. Our aim was to assess deep tendon reflexes objectively with a new reflex quantification method.
    Matched MeSH terms: Motion*
  16. Ali Md Nadzalan
    MyJurnal
    This study was conducted to investigate i) while the shoulder was in 180° of flexion and the elbow extended, which of the forearm position (supination, pronation and neutral) can generate the greatest handgrip strength, ii) is there any correlation of the handgrip strength between the dominant hand (right hand) and non-dominant hand (left hand) in each forearm position, and iii) will the dominant hand possessed 10% higher handgrip strength than the non-dominant hand. 100 right handed sedentary active students age 22.20 years old (± 1.03), height 172.83 cm (± 6.37), body mass 68.87 (± 11.52) and grip position 3.77 (± 0.77) were recruited in this study. The result indicated that for both the dominant and non-dominant hand, when the shoulder is in 180˚ flexion of the body with the elbow extended, the greatest grip strength was obtained when the forearm was in neutral position followed by pronation and supination position. Post Hoc analysis showed that for both dominant hand and non-dominant hand, pronation and supination forearm position produced greater strength score compared to supination forearm position (p0.05). In all forearm position, participants were shown to produced significantly greater strength in their dominant hand and all the scores were more than 10% greater compared to when using non-dominant hand. Positive relationships were also found for the strength score between dominant hand and non-dominant hand. As the conclusion, different shoulder, elbow and forearm position can affect handgrip strength.
    Matched MeSH terms: Range of Motion, Articular
  17. Ahmad, D., Jamarei, O., Sulaiman, S., Fashina, A.B., Akande, F.B.
    MyJurnal
    The motion resistances of 660 mm pneumatic and rigid bicycle wheels of the same rim diameter were measured experimentally using the developed tractor-towed single non-lug narrow wheel motion resistance test rig for traction studies. The motion resistances measured were taken to be the towing forces determined in real time using Mecmesin Basic Force Gauge (BFG 2500). The test variables included two test surfaces [tilled and wet (mud) surfaces], the dynamic load and the towing velocity. The tyre inflation pressure of 414 kPa was chosen to make the surface synonymous with that of the rigid wheel. Motion resistance ratios of the two wheels were determined empirically and through semi-empirical approach. The motion resistances of the rigid wheel were found to be greater than those of the pneumatic wheel for both surfaces. Consequently, the motion resistance ratios of the rigid wheel were greater than those obtained
    from the pneumatic wheel. Analysis of variance showed that there were significant differences between the means of the motion resistance measured on the test surfaces, as well as between the two wheels and their interactions with the test surfaces. The motion resistance ratio exhibited a linear relationship with the towing velocity, while the relationship with the dynamic load was quadratic. However, such a relationship is either direct or inverse with the respective variables. The motion resistance ratio models for the pneumatic and rigid wheels showed that on different test conditions of the dynamic loads and the towing velocities, the relationships between the motion resistance ratio and the dynamic load, and motion resistance with dynamic load were also different.
    Matched MeSH terms: Motion
  18. Kondo E, Merican AM, Yasuda K, Amis AA
    Arthroscopy, 2014 Mar;30(3):335-43.
    PMID: 24581258 DOI: 10.1016/j.arthro.2013.12.003
    The purpose of this study was to clarify the changes in the kinematics of the knee that result from isolated deficiency of the anteromedial (AM) or posterolateral (PL) bundle.
    Matched MeSH terms: Range of Motion, Articular
  19. Merican AM, Ghosh KM, Baena FR, Deehan DJ, Amis AA
    Knee Surg Sports Traumatol Arthrosc, 2014 Mar;22(3):526-33.
    PMID: 23271038 DOI: 10.1007/s00167-012-2312-z
    PURPOSE: To study the effect of increasing patellar thickness (overstuffing) on patellofemoral kinematics in total knee arthroplasty and whether subsequent lateral retinacular release would restore the change in kinematics.

    METHODS: The quadriceps of eight fresh-frozen knees were loaded on a custom-made jig. Kinematic data were recorded using an optical tracking device for the native knee, following total knee arthroplasty (TKA), then with patellar thicknesses from -2 to +4 mm, during knee extension motion. Staged lateral retinacular releases were performed to examine the restoration of normal patellar kinematics.

    RESULTS: Compared to the native knee, TKA led to significant changes in patellofemoral kinematics, with significant increases in lateral shift, tilt and rotation. When patellar composite thickness was increased, the patella tilted further laterally. Lateral release partly corrected this lateral tilt but caused abnormal tibial external rotation. With complete release of the lateral retinaculum and capsule, the patella with an increased thickness of 4 mm remained more laterally tilted compared to the TKA with normal patellar thickness between 45° and 55° knee flexion and from 75° onwards. This was on average by 2.4° ± 2.9° (p 

    Matched MeSH terms: Range of Motion, Articular
  20. Abd Razak NA, Abu Osman NA, Kamyab M, Wan Abas WA, Gholizadeh H
    Am J Phys Med Rehabil, 2014 May;93(5):437-44.
    PMID: 24429510 DOI: 10.1097/PHM.0b013e3182a51fc2
    This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.
    Matched MeSH terms: Range of Motion, Articular/physiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links