Displaying publications 941 - 960 of 1919 in total

Abstract:
Sort:
  1. Norhaya MR, Wazi RA, Azhar AA
    Med J Malaysia, 2009 Mar;64(1):77-9.
    PMID: 19852329
    Treatment for chronic respiratory failure has advanced since the introduction of domiciliary non-invasive ventilatory devices. This has given a new light of hope for patients with chronic respiratory failure secondary to various causes. We report a series of patients with respiratory failure of different origins and types of management that they received. Four patients received bilevel positive airway pressure (BiPAP) and one patient received continuous positive airway pressure (CPAP).
    Matched MeSH terms: Positive-Pressure Respiration
  2. Gopalai AA, Senanayake SM, Kiong LC, Gouwanda D
    J Bodyw Mov Ther, 2011 Oct;15(4):453-64.
    PMID: 21943619 DOI: 10.1016/j.jbmt.2010.10.005
    A method for assessing balance, which was sensitive to changes in the postural control system is presented. This paper describes the implementation of a force-sensing platform, with force sensing resistors as the sensing element. The platform is capable of measuring destabilized postural perturbations in dynamic and static postural conditions. Besides providing real-time qualitative assessment, the platform quantifies the postural control of the subjects. This is done by evaluating the weighted center of applied pressure distribution over time. The objective of this research was to establish the feasibility of using the force-sensing platform to test and gauge the postural control of individuals. Tests were conducted in Eye Open and Eye Close states on Flat Ground (static condition) and the balance trainer (dynamic condition). It was observed that the designed platform was able to gauge the sway experienced by the body when subject's states and conditions changed.
    Matched MeSH terms: Pressure
  3. Marikkar JM, Ghazali HM, Long K
    J Oleo Sci, 2010;59(1):7-14.
    PMID: 20032594
    This study was to characterize the seed fat from Madhuca longifolia known as Mee fat and its solid and liquid fractions with the objective of distinguishing them. A sample of Mee fat was partitioned into solid and liquid fractions using acetone as the solvent medium. The isolated fractions were compared to the native Mee fat sample with respect to various physico-chemical parameters using standard chemical methods as well as instrumental techniques such as, gas liquid chromatography (GLC), reversed-phase high performance liquid chromatography (RP-HPLC), and differential scanning calorimetry (DSC). Basic analyses indicated that there were wide variations between the native sample and its fractions with respect to iodine value (IV), and slip melting point (SMP). The cloud point (CP) of the liquid fraction was found to be 10.5 degrees C. Fatty acid compositional analyses showed that the proportion of saturated fatty acids (SFA) such as palmitic and stearic went up in the high-melting fraction (HMF) while in low-melting fraction (LMF) the proportion of unsaturated fatty acid (USFA) such as oleic and lenoleic increased. According to the HPLC analyses, Mee fat had a tiacyl glycerol (TAG) sequence similar to that of palm oil. After fractionation, the solid and liquid fractions obtained were found to have TAG profiles very much different from the native sample. Thermal analyses by DSC showed that Mee fat had two-widely separated high and low melting thermal transitions, a feature which was beneficial for the effective separation of solid and liquid fractions. The thermal profiles displayed by the fractions were clearly distinguishable from that of the native sample.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  4. Adzahan N, Jalili M, Jinap S
    PMID: 24785182 DOI: 10.1080/19440040903384190
    A total of 126 local and imported samples of commercial white and black pepper in Malaysia were analysed for aflatoxins B1, B2, G1 and G2 (AFB1, AFB2, AFG1, AFG2) content using high-performance liquid chromatography (HPLC) with a fluorescence detector (FD). An acetonitrile-methanol-water (17 : 29 : 54; v/v) mixture was used as a mobile phase and clean-up was using an immunoaffinity column (IAC). Seventy out of 126 (55.5%) samples were contaminated with total aflatoxins, although only low levels of aflatoxins were found ranging from 0.1 to 4.9 ng g(-1). Aflatoxin B1 showed the highest incidence of contamination and was found in all contaminated samples. There was a significant difference between type of samples and different brands (p < 0.05). The results showed black peppers were more contaminated than white peppers.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  5. Mistiran AF, Dzarr AA, Gan SH
    Toxicol. Mech. Methods, 2010 Oct;20(8):472-81.
    PMID: 20626302 DOI: 10.3109/15376516.2010.503246
    This paper describes a new validated high performance liquid chromatography (HPLC) method for the simultaneous determination of two anti-cancer drugs, Arabinoside-C (Ara-C) and doxorubicin hydrochloride (DOX). A simultaneous determination method saves cost and time as both drugs can be injected into a single HPLC system without the need to change or re-equilibrate with a new mobile phase. The objective of the study is to develop a simultaneous determination method of two anti-cancer drugs, Ara-C and DOX. The mobile phase consisted of a mixture (45:55) of acetonitrile:ammonium hydrogen phosphate aqueous solution (0.01 M) at pH 6.2 at a flow rate of 0.3 ml/min, with UV detection at 252 nm. Separation was achieved on a C-18 column (5 µm: 250 mm × 4.6 mm) maintained at 30°C in a column oven. The method was linear between 325 ng/ml and 10 µg/ml for Ara-C and 625 ng/ml and 20 µg/ml for DOX. The limit of detection (LOD) was 20 ng/ml for Ara-C and 60 ng/ml for DOX. The developed HPLC method achieved good precision and accuracy as well as limit of quantitations. The developed and validated method is suitable to be used for routine analysis of Ara-C and DOX.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  6. Chan KL, Choo CY, Morita H, Itokawa H
    Planta Med, 1998 Dec;64(8):741-5.
    PMID: 17253320 DOI: 10.1055/s-2006-957570
    An analytical method using HPLC with UV detection was developed to investigate the quassinoid content of Eurycoma longifolia Jack (Simaroubaceae) collected from various sources. Eurycomanone (1), longilactone (2), 14,15beta-dihydroxyklaineanone (3), 15beta-acetyl-14-hydroxyklaineanone (4), 6alpha-hydroxyeurycomalactone (5), and eurycomalactone (7) were isolated as reference standards and together with the synthesized 1beta,12alpha,15beta-triacetyleurycomanone (6, internal standard), were identified by NMR, MS, UV and IR spectroscopies. Their coefficient of variation values for 0.50-35 microg ml(-1) concentrations of quassinoids and their retention times measured within- and between-day were small. The recoveries of the spiked quassinoids in E. longifolia samples and their detection limits at 8.5 times signal to noise ratio were 99.75-109.13% and 0.01 microg ml(-1), respectively. From the root samples analysed, 1 had the highest concentration, being about 16.8-39.6 fold higher than the other quassinoids 2, 3, 5, 7 but 145.3 fold higher than 4 which showed the lowest concentration.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  7. Akkbik M, Assim ZB, Ahmad FB
    Int J Anal Chem, 2011;2011:858153.
    PMID: 21760792 DOI: 10.1155/2011/858153
    An HPLC method with ultraviolet-visible spectrophotometry detection has been optimized and validated for the simultaneous determination of phenolic compounds, such as butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) as antioxidants, and octyl methyl cinnamate (OMC) as UVB-filter in several personal care products. The dynamic range was between 1 to 250 mg/L with relative standard deviation less than 0.25% (n = 4). Limits of detection for BHA, BHT, and OMC were 0.196, 0.170, and 0.478 mg/L, respectively. While limits of quantification for BHA, BHT, and OMC were 0.593, 0.515, and 1.448 mg/L, respectively. The recovery for BHA, BHT, and OMC was ranged from 92.1-105.9%, 83.2-108.9%, and 87.3-103.7%, respectively. The concentration ranges of BHA, BHT, and OMC in 12 commercial personal care samples were 0.13-4.85, 0.16-2.30, and 0.12-65.5 mg/g, respectively. The concentrations of phenolic compounds in these personal care samples were below than maximum allowable concentration in personal care formulation, that is, 0.0004-10 mg/g, 0.002-5 mg/g, and up to 100 mg/g for BHA, BHT, and OMC, respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  8. Alam N, Hossain M, Khalil MI, Moniruzzaman M, Sulaiman SA, Gan SH
    PMID: 21854608 DOI: 10.1186/1472-6882-11-65
    Withania somnifera is an important medicinal plant traditionally used in the treatment of many diseases. The present study was carried out to characterize the phenolic acids, flavonoids and 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) scavenging activities in methanolic extracts of W. somnifera fruits, roots and leaves (WSFEt, WSREt and WSLEt).
    Matched MeSH terms: Chromatography, High Pressure Liquid
  9. Lim E, Alomari AH, Savkin AV, Dokos S, Fraser JF, Timms DL, et al.
    Artif Organs, 2011 Aug;35(8):E174-80.
    PMID: 21843286 DOI: 10.1111/j.1525-1594.2011.01268.x
    We propose a deadbeat controller for the control of pulsatile pump flow (Q(p) ) in an implantable rotary blood pump (IRBP). Noninvasive measurements of pump speed and current are used as inputs to a dynamical model of Q(p) estimation, previously developed and verified in our laboratory. The controller was tested using a lumped parameter model of the cardiovascular system (CVS), in combination with the stable dynamical models of Q(p) and differential pressure (head) estimation for the IRBP. The control algorithm was tested with both constant and sinusoidal reference Q(p) as input to the CVS model. Results showed that the controller was able to track the reference input with minimal error in the presence of model uncertainty. Furthermore, Q(p) was shown to settle to the desired reference value within a finite number of sampling periods. Our results also indicated that counterpulsation yields the minimum left ventricular stroke work, left ventricular end diastolic volume, and aortic pulse pressure, without significantly affecting mean cardiac output and aortic pressure.
    Matched MeSH terms: Blood Pressure
  10. Kalani M, Yunus R
    Int J Nanomedicine, 2011;6:1429-42.
    PMID: 21796245 DOI: 10.2147/IJN.S19021
    The review focuses on the application of supercritical fluids as antisolvents in the pharmaceutical field and demonstrates the supercritical antisolvent method in the use of drug encapsulation. The main factors for choosing the solvent and biodegradable polymer to produce fine particles to ensure effective drug delivery are emphasized and the effect of polymer structure on drug encapsulation is illustrated. The review also demonstrates the drug release mechanism and polymeric controlled release system, and discusses the effects of the various conditions in the process, such as pressure, temperature, concentration, chemical compositions (organic solvents, drug, and biodegradable polymer), nozzle geometry, CO(2) flow rate, and the liquid phase flow rate on particle size and its distribution.
    Matched MeSH terms: Pressure
  11. Sobhanzadeh E, Abu Bakar NK, Bin Abas MR, Nemati K
    J Hazard Mater, 2011 Feb 28;186(2-3):1308-13.
    PMID: 21177032 DOI: 10.1016/j.jhazmat.2010.12.001
    A simple and effective multiresidue method based on precipitation at low temperature followed by matrix solid-phase dispersion-sonication was developed and validated to determine dimethoate, malathion, carbaryl, simazine, terbuthylazine, atrazine and diuron in palm oil using liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS). Liquid-liquid extraction (LLE) followed by low temperature method were optimized by studying the effect of type and volume of organic solvent (acetonitrile, acetonitrile:n-hexane (3:2 v/v) and acetone) and time of freezing to obtain high recovery yield and low co-extract fat residue in the final extract. The optimal conditions for matrix solid-phase dispersion (MSPD) were obtained using 5 g of palm oil, 2 g of primary secondary amine (PSA) as dispersing sorbent, 1 g of graphitized carbon black (GCB) as clean-up sorbent and 15 mL of acetonitrile as eluting solvent under conditions of 15 min ultrasonication at room temperature. Method validation was performed in order to study sensitivity, linearity, precision, and accuracy. Average recoveries at three concentration levels (25, 50 and 100 μg kg(-1)) were found in the range of 72.6-91.3% with relative standard deviations between 5.3% and 14.2%. Detection and quantification limits ranged from 1.5 to 5 μg kg(-1) and from 2.5 to 9 μg kg(-1), respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  12. Gam LH, Latiff A
    Int J Biol Sci, 2005;1(3):103-9.
    PMID: 16094462
    The microheterogeneity property of hCG with regards to its sialic acid contents resulted in variable mobility of the glycoprotein in SDS-PAGE. The intact hCG molecule is composed of two dissimilar subunits, namely alpha- and beta-subunits. The identification of hCG bands in SDS-PAGE was accomplished by the immunoblotting experiment, whereby the antibody directed toward the specific region of beta-subunit of hCG was used. The data shows that the different mobility of intact hCG was attributed to the different degree of desialylation of the glycoprotein. Nevertheless, unlike the intact hCG, the mobility of its beta-subunit was not affected by its variety sialic acid content. This characteristic of beta-hCG is beneficial when semi-quantification of total hCG is required. Quantification of hCG using the HPLC-reversed phase C18 analytical column is not possible as the glycoprotein was eluted in multiple fractions at different retention times. The identification of denatured hCG (HPLC eluted fractions) was carried out by immunoblotting experiment whilst immunoassay technique failed to detect its presence in any fraction.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  13. Halimah M, Tan YA, Ismail BS
    J Environ Sci Health B, 2004;39(5-6):765-77.
    PMID: 15620085
    Four methods were developed for the analysis of fluroxypyr in soil samples from oil palm plantations. The first method involved the extraction of the herbicide with 0.05 M NaOH in methanol followed by purification using acid base partition. The concentrated material was subjected to derivatization and then cleaning process using a florisil column and finally analyzed by gas chromatography (GC) equipped with electron capture detector (ECD). By this method, the recovery of fluroxypyr from the spiked soil ranged from 70 to 104% with the minimum detection limit at 5 microg/kg. The second method involved solid liquid extraction of fluroxypyr using a horizontal shaker followed by quantification using high performance liquid chromatography (HPLC) equipped with UV detector. The recovery of fluroxypyr using this method, ranged from 80 to 120% when the soil was spiked with fluroxypyr at 0.1-0.2 microg/g soil. In the third method, the recovery of fluroxypyr was determined by solid liquid extraction using an ultrasonic bath. The recovery of fluroxypyr at spiking levels of 4-50 microg/L ranged from 88 to 98% with relative standard deviations of 3.0-5.8% with a minimum detection limit of 4 microg/kg. In the fourth method, fluroxypyr was extracted using the solid liquid extraction method followed by the cleaning up step with OASIS HLB (polyvinyl dibenzene). The recovery of fluroxypyr was between 91 and 95% with relative standard deviations of 4.2-6.2%, respectively. The limit of detection in method 4 was further improved to 1 pg/kg. When the weight of soil used was increased 4 fold, the recovery of fluroxypyr at spiking level of 1-50 microg/kg ranged from 82-107% with relative standard deviations of 0.5-4.7%.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  14. Yuen KH, Peh KK, Billa N, Chan KL, Toh WT
    Drug Dev Ind Pharm, 1998 Feb;24(2):193-6.
    PMID: 15605452
    The bioavailability of a generic preparation of acyclovir (Avorax) was compared with the innovator product, Zovirax. Twelve healthy volunteers participated in the study, conducted according to a randomized, two-way crossover design. The preparations were compared using the parameters area under the plasma concentration time curve (AUC(0-infinity), peak plasma concentration (Cmax), and time to reach peak plasma concentration (Tmax). No statistically significant difference was observed between the Tmax or the logarithmic transformed AUC(0-infinity) and C(max) values of the two preparations. In addition, the 90% confidence interval for the ratio of the logarithmic transformed AUC(0-infinity) values of Avorax over those of Zovirax was found to lie between 0.85 and 1.06, while that of the logarithmic transformed Cmax values was between 0.95 and 1.25, being within the bioequivalence limit of 0.80-1.25. Moreover, the elimination rate constant (k(e)), elimination half-life (t(1/2)), and apparent volume of distribution (Vd) values obtained with the two preparations were comparable and not significantly different statistically.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  15. Salmi AA, Nor Aliza AG, Nik Zaki NM, Wong AR, Aida HR
    Med J Malaysia, 2010 Jun;65(2):115-8.
    PMID: 23756794 MyJurnal
    Arterial stiffness is an index of vascular health; normal pregnancy is associated with reduced arterial stiffness. This cross sectional study compared arterial stiffness in older (≥35 years) and the younger (≤34 years) age groups of pregnant women. Arterial stiffness was assessed noninvasively in 66 pregnant women between 23 - 32 weeks gestation (41 women ≤ 34 years, 25 women ≥ 35 years) using the parameters pulse wave analysis and pulse wave velocity. Blood pressure (BP), body mass index (BMI), serum total cholesterol (TC) and fasting blood glucose (FBS) were also recorded. Mean ages of the younger and older age groups were 27.6±0.62 and 39.3±0.58 years; no significant difference was seen between the groups in their BMI, TC, FBS, SBP, DBP and gestational age. The older age group of women have increased arterial stiffness (augmentation index 19.4±1.9% vs 13.2±1.6%, p=0.015) and aortic stiffness (pulse wave velocity 8.7±0.3 vs 7.7±0.2 m/s, p=0.004) compared to the younger women. Linear regression analysis showed a positive significant correlation between age and augmentation index (R=0.278, p=0.026), and pulse wave velocity (R=0.350, p=0.004). We conclude that older pregnant women has increased arterial stiffness compared to a younger age group of pregnant women suggesting that vascular changes due to ageing occurs in pregnancy despite cardiovascular adaptations occurring in pregnancy.
    Matched MeSH terms: Blood Pressure
  16. Ramasamy R, Maqbool M, Mohamed AL, Noah RM
    Cell Immunol, 2010;263(2):230-4.
    PMID: 20471005 DOI: 10.1016/j.cellimm.2010.04.004
    Neutrophils play a significant role in maintaining the integrity of innate immunity via their potent respiratory burst activity. However, the uncontrolled activation of respiratory burst in neutrophils also attributes to chronic diseases such as primary hypertension and atherosclerosis. In our study, we have investigated the activation of respiratory burst function of neutrophils harvested from essential hypertensive patients. In the presence of stimuli PMA and opsonized zymosan (OZ), hypertensive patients' neutrophils secrete significantly higher amount of superoxide anions compared to normotensive control. Although the magnitude of activation varies between both groups, yet the kinetics of activation is similar. When normotensive control's neutrophils were pre-treated with hypertensive serum, the cells failed to migrate toward fMLP which indicates the impairment of the migration property. In conclusion, the respiratory burst activity of neutrophils is affected by hypertension and their elevated superoxide anions production could be an aggravating factor in hypertension-related complication.
    Matched MeSH terms: Venous Pressure
  17. George E, Jama T, Azian AS, Rahimah A, Zubaidah Z
    Med J Malaysia, 2009 Dec;64(4):321-2.
    PMID: 20954559
    A rare case of thalassaemia-intermedia involving a non-deletion alpha thalassemia point mutation in the alpha1-globin gene CD59 (GGC --> GAC) and a deletion alpha+ (-alpha(3.7)) thalassaemia in which use of high performance liquid chromatography (HPLC) C-gram Hb subtype profile and DNA molecular analysis helped establish the diagnosis.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  18. Mayne KJ, Staplin N, Keane DF, Wanner C, Brenner S, Cejka V, et al.
    J Am Soc Nephrol, 2024 Feb 01;35(2):202-215.
    PMID: 38082486 DOI: 10.1681/ASN.0000000000000271
    SIGNIFICANCE STATEMENT: SGLT2 inhibitors reduce risk of kidney progression, AKI, and cardiovascular disease, but the mechanisms of benefit are incompletely understood. Bioimpedance spectroscopy can estimate body water and fat mass. One quarter of the EMPA-KIDNEY bioimpedance substudy CKD population had clinically significant levels of bioimpedance-derived "Fluid Overload" at recruitment. Empagliflozin induced a prompt and sustained reduction in "Fluid Overload," irrespective of sex, diabetes, and baseline N-terminal pro B-type natriuretic peptide or eGFR. No significant effect on bioimpedance-derived fat mass was observed. The effects of SGLT2 inhibitors on body water may be one of the contributing mechanisms by which they mediate effects on cardiovascular risk.

    BACKGROUND: CKD is associated with fluid excess that can be estimated by bioimpedance spectroscopy. We aimed to assess effects of sodium glucose co-transporter 2 inhibition on bioimpedance-derived "Fluid Overload" and adiposity in a CKD population.

    METHODS: EMPA-KIDNEY was a double-blind placebo-controlled trial of empagliflozin 10 mg once daily in patients with CKD at risk of progression. In a substudy, bioimpedance measurements were added to the main trial procedures at randomization and at 2- and 18-month follow-up visits. The substudy's primary outcome was the study-average difference in absolute "Fluid Overload" (an estimate of excess extracellular water) analyzed using a mixed model repeated measures approach.

    RESULTS: The 660 substudy participants were broadly representative of the 6609-participant trial population. Substudy mean baseline absolute "Fluid Overload" was 0.4±1.7 L. Compared with placebo, the overall mean absolute "Fluid Overload" difference among those allocated empagliflozin was -0.24 L (95% confidence interval [CI], -0.38 to -0.11), with similar sized differences at 2 and 18 months, and in prespecified subgroups. Total body water differences comprised between-group differences in extracellular water of -0.49 L (95% CI, -0.69 to -0.30, including the -0.24 L "Fluid Overload" difference) and a -0.30 L (95% CI, -0.57 to -0.03) difference in intracellular water. There was no significant effect of empagliflozin on bioimpedance-derived adipose tissue mass (-0.28 kg [95% CI, -1.41 to 0.85]). The between-group difference in weight was -0.7 kg (95% CI, -1.3 to -0.1).

    CONCLUSIONS: In a broad range of patients with CKD, empagliflozin resulted in a sustained reduction in a bioimpedance-derived estimate of fluid overload, with no statistically significant effect on fat mass.

    TRIAL REGISTRATION: Clinicaltrials.gov: NCT03594110 ; EuDRACT: 2017-002971-24 ( https://eudract.ema.europa.eu/ ).

    Matched MeSH terms: Blood Pressure
  19. Azhany Y, Rahman WFWA, Jaafar H, Low JH, Yusuf WNW, Liza-Sharmini AT, et al.
    Int J Mol Sci, 2023 Apr 17;24(8).
    PMID: 37108535 DOI: 10.3390/ijms24087372
    Post-surgical scarring is a known cause of trabeculectomy failure. The aim of this study was to investigate the effectiveness of ranibizumab as an adjuvant anti-scarring agent in experimental trabeculectomy. Forty New Zealand white rabbits were randomised into four eye treatment groups: groups A (control), B (ranibizumab 0.5 mg/mL), C (mitomycin C [MMC] 0.4 mg/mL), and D (ranibizumab 0.5 mg/mL and MMC 0.4 mg/mL). Modified trabeculectomy was performed. Clinical parameters were assessed on post-operative days 1, 2, 3, 7, 14, and 21. Twenty rabbits were euthanised on day 7, and the other twenty were euthanised on day 21. Eye tissue samples were obtained from the rabbits and stained with haematoxylin and eosin (H&E). All treatment groups showed a significant difference in IOP reduction compared with group A (p < 0.05). Groups C and D showed a significant difference in bleb status on days 7 (p = 0.001) and 21 (p = 0.002) relative to group A. H&E staining showed significantly low fibrotic activity (p < 0.001) in group C on both days and inflammatory cell grade in group B on day 7 (p < 0.001). The grade for new vessel formation was significantly low in groups B and D on day 7 (p < 0.001) and in group D on day 21 (p = 0.007). Ranibizumab plays a role in reducing scarring, and a single application of the ranibizumab-MMC combination showed a moderate wound-modulating effect in the early post-operative phase.
    Matched MeSH terms: Intraocular Pressure
  20. Chang C, Chan H, Lim S, Khoo E, Zulkiflee O
    Malays Orthop J, 2014 Jul;8(2):49-51.
    PMID: 25279094 MyJurnal DOI: 10.5704/MOJ.1407.004
    Postoperative wound infection in an instrumented spine patient is often disastrous. Management includes implant removal leading to spine instability. Negative pressure wound therapy (NPWT) applied to the spine surgical wound is one of the wound care technique with successful results. We report a case of a man who sustained Chance fracture of Lumbar 1 (L1) vertebra treated with long segment posterior instrumentation, who unfortunately developed Extended-spectrum beta-lactamase (ESBL) positive E. coli infection one month after the operation. After careful debridement of the wound, the implant became exposed. Three cycles of NPWT were applied and the wound healed with granulation tissue completely covering the implant, and thus negating the need to remove the implant. In conclusion, the NPWT is a good alternative in postoperative wound management especially in an instrumented spine patient.
    Matched MeSH terms: Negative-Pressure Wound Therapy
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)