MATERIALS AND METHODS: A total of 14 children with CVM/CND with unilateral cochlear implant (CI) implanted before the age of 4 years old were matched and compared with 14 children with normal inner ear structures. Their improvement in auditory performance was evaluated twice using CAP-II score and SIR scales at 6-month intervals, with the baseline evaluation done at least 6 months after implantation.
RESULTS: The average age of implantation was 31±8 and 33±7 months for the control group and the case (CVM/CND) group, respectively. Overall, there were no significant differences in outcome when comparing the entire cohort of case subjects and their matched control subjects in this study. However, the improvement in CAP-II scores and SIR scales among the case subjects in between the first and second evaluations was statistically significant (p=0.040 and p=0.034, respectively). With longer duration of CI usage, children with CVM/CND showed significant speech perception outcome evident by their SIR scales (p=0.011).
CONCLUSION: Children with radiographically malformed inner ear structures who were implanted before the age of 4 years have comparable performance to their matched counterparts, evident by their similar improvement of CAP-II scores and SIR scales over time. Hence, this group of children benefited from cochlear implantation.
DESIGN: A cross-sectional study was conducted from January to March 2018; data on patients' sociodemographic characteristics, diabetes knowledge, perceived social support and health literacy level were collected. Health literacy level was measured using the European Health Literacy Survey Questionnaire (HLS-EU-Q47).
SETTING: Patients were recruited from four primary care clinics in Perak, Malaysia.
PARTICIPANTS: Adult patients diagnosed with T2DM who attended the study clinics during the study period.
PRIMARY OUTCOME VARIABLE: Patients with HLS-EU-Q47 General Index of ≤33 points were classified as having limited health literacy.
RESULTS: The prevalence of limited health literacy was 65.3% (n=279). In bivariate analysis, patients' ethnicity (p=0.04), highest education level (p<0.001), monthly income (p=0.003), having health insurance (p=0.007), English language fluency (p<0.001), Malay language fluency (p=0.021), attending diabetes education sessions (p<0.001), perceived social support (p<0.001) and diabetes knowledge (p=0.019) were factors associated with limited health literacy. In logistic regression, not being fluent in English was associated with limited health literacy (OR=2.36, 95% CI 1.30 to 4.30) whereas having high perceived social support (OR=0.52, 95% CI 0.40 to 0.69) and having attended diabetes education sessions (OR=0.42, 95% CI 0.27 to 0.68) were associated with adequate health literacy.
CONCLUSION: The prevalence of limited health literacy is high among patients with T2DM in Perak, Malaysia. Strategies to improve health literacy in these patients must consider the influences of English fluency, attendance at diabetes education sessions and social support, and may need to adopt a universal approach to addressing limited health literacy.
OBJECTIVE: To review surgical and audiological outcomes of COM patients that underwent CI.
MATERIAL AND METHODS: Retrospective review of patients above 18 years old.
RESULTS: Ten patients with complete data were included. Patients were aged 24-69 years old. Tympanoplasty and mastoidectomy were performed before CI. Imaging was performed to rule out ossifications. Eight patients underwent a standard canal wall up with either cochleostomy or round window approach. One patient had additional canalplasty and tympanoplasty and another one had blind sac procedure respectively. Analysis of the hearing aided level with CI and hearing aid showed significant benefit provided by the CI (Z = 2.803, p = .005).
DISCUSSION: Creating a dry and safe ear is important prior to CI. Definite hearing improvement is seen in all our cases that helped them to become independent again in their daily life. Hearing aid usage pre-CI might not be important as the hearing aids may continue to cause discharging ears and the benefits of hearing aids in severe to profound hearing loss are very minimal.
CONCLUSIONS: Cochlear implant is safe and effective in COM patients.
OBJECTIVE: This study aimed to explore experiences related to health literacy in Asian patients with T2DM.
DESIGN: This is a qualitative study using in-depth interviews and focus group discussions. A framework analysis was used to analyse the data.
SETTING AND PARTICIPANTS: articipants (n = 24) were multi-ethnic patients with T2DM (n = 18) and their primary health-care providers (n = 6). This study was conducted in four primary health-care clinics in Malaysia.
RESULTS: Nine subthemes were identified within the four dimensions of health literacy: accessing, understanding, appraising and applying information.
DISCUSSION: Motivated patients actively sought information, while others passively received information shared by family members, friends or even strangers. Language and communication skills played important roles in helping patients understand this information. Information appraisal was lacking, with patients just proceeding to apply the information obtained. Patients' use of information was influenced by their self-efficacy, and internal and external barriers.
CONCLUSION: In conclusion, the experiences of multi-ethnic patients with T2DM regarding health literacy were varied and heavily influenced by their cultures.
OBJECTIVE: To assess the auditory outcome of paediatric bilateral cochlear implant in Universiti Kebangsaan Malaysia.
MATERIALS AND METHODS: This was a cross-sectional and descriptive study single centre analysis. Categories of Auditory Performance (CAP-II) scale and Speech, Spatial and Qualities (SSQ) of Hearing questionnaire were used.
RESULTS: Forty-six patients were recruited. Majority of the children (30.4%) rated 7 and 23.9% scored perfectly (9) based on the CAP-II Scale. The least performing children were rated 5 (average). Children that were implanted sequentially within 24 months showed median CAP-II scale of 7. No significant correlation seen between CAP-II and the duration interval, use and age of 1st CI (p > .05). The speech domain of SSQ-P scale showed median value of 8 indicating good speech understanding. The spatial hearing domain had median value of 7, quality of hearing domain had median of 8. Significant correlation seen in hearing in noise with the duration of use of CI (p
METHOD: This was a retrospective study in which high-resolution computed tomography images of paediatric patients with severe-to-profound sensorineural hearing loss were reviewed. A cochlear nerve canal diameter of 1.5 mm or less in the axial plane was classified as stenotic. Semicircular canals and other bony labyrinth morphology and abnormality were evaluated.
RESULTS: Cochlear nerve canal stenosis was detected in 65 out of 265 ears (24 per cent). Of the 65 ears, 17 ears had abnormal semicircular canals (26 per cent). Significant correlation was demonstrated between cochlear nerve canal stenosis and semicircular canal abnormalities (p < 0.01). Incomplete partition type II was the most common accompanying abnormality of cochlear nerve canal stenosis (15 out of 65, 23 per cent).
CONCLUSION: Cochlear nerve canal stenosis is statistically associated with semicircular canal abnormalities. Whenever a cochlear nerve canal stenosis is present in a patient with sensorineural hearing loss, the semicircular canal should be scrutinised for presence of abnormalities.
OBJECTIVE: This study was aimed to inspect the ameliorative action of A. chinensis synthesized ZnONPs against M. pneumoniae infected pneumonia mice model.
MATERIALS AND METHODS: ZnO NPs was synthesized from Albizia chinensis bark extract and characterized by UV-Vis spectroscopy, Fourier Transform Infrared (FTIR), Transmission Electron Microscopy (TEM), energy dispersive X-ray (EDX) and atomic force microscope (AFM) analyses. The antibacterial effectual of synthesized ZnONPs were examined against clinical pathogens. The pneumonia was induced to BALB/c mice via injecting the M. pneumoniae and treated with synthesized ZnONPs, followed by the total protein content, total cell counts and inflammatory mediators level was assessed in the BALF of experimental animals. The Histopathological investigation was done in the lung tissues of test animals.
RESULTS: The outcomes of this work revealed that the formulated ZnONPs was quasi-spherical, radial and cylindrical; the size was identified as 116.5 ± 27.45 nm in diameter. The in vitro antimicrobial potential of formulated ZnO-NPs displayed noticeable inhibitory capacity against the tested fungal and bacterial strains. The administration of synthesized ZnO-NPs in MP infected mice model has significantly reduced the levels of total protein, inflammatory cells, inflammatory cytokines such as IL-1, IL-6, IL-8, tumour necrosis factor-alpha (TNF-a) and transforming growth factor (TGF). Besides, the histopathological examination of MP infected mice lung tissue showed the cellular arrangements were effectively retained after administration of synthesized ZnO-NPs.
CONCLUSION: In conclusion, synthesized ZnO-NPs alleviate pneumonia progression via reducing the level of inflammatory cytokines and inflammatory cells in MP infected mice model.
Methods: This study comprised of two phases namely discovery and verification. In the discovery phase, proteins in the pooled plasma samples from young male adults between 18 and 45 years (10 AMI patients and 10 controls) were separated using two-dimensional electrophoresis. The protein spots that were expressed differently in the AMI patients were identified via matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. The plasma concentrations of these proteins were quantified using enzyme-linked immunosorbent assay during the verification phase (40 AMI patients and 80 controls).
Results: Haptoglobin (Hp), apolipoprotein AI (Apo AI) and apolipoprotein AIV (Apo AIV) were up-regulated in the discovery phase. In the verification phase, the plasma concentration of Hp was significantly higher in AMI patients than the controls (P < 0.001). Logistic regression showed an association between Hp and AMI in young adults (odds ratio [OR] = 1.016, 95% CI: 1.002-1.030, P = 0.025) independent of other AMI risk factors. Hp was significantly correlated with high sensitivity C-reactive protein (hs-CRP) (r = 0.424, P < 0.001).
Conclusion: In young adults with AMI, plasma Hp concentrations were elevated and it is independently associated with AMI. A positive correlation with hs-CRP suggests Hp could be a potential biomarker of AMI in young adults.
Method: This study was conducted between November and December 2016 at two primary care clinics that offered integrated diabetes care at the time. These sites were selected to assess the discriminative validity of the PACIC. Site 1 is a Malaysian Ministry of Health-run primary care clinic while site 2 is a university-run hospital-based primary care clinic. Only site 1 annually monitors patient performance and encourages them to achieve their HbA1c targets using a standard checklist. Patients with diabetes mellitus who understood English were recruited. Participants were asked to fill out the PACIC at baseline and two weeks later.
Results: A total of 200 out of the 212 invited agreed to participate (response rate=94.3%). Confirmatory factor analysis confirmed the 5-factor structure of the PACIC. The overall PACIC score and the score in two of the five domains were significantly higher at site 1 than at site 2. The overall Cronbach's alpha was 0.924. At test-retest, intra-class correlation coefficient values ranged from 0.641 to 0.882.
Conclusion: The English version of the PACIC was found to be a valid and reliable instrument to assess the quality of care among patients with diabetes mellitus in Malaysia.
Methods: This retrospective study was conducted from January 2014-December 2016 at a tertiary hospital in Malaysia. All neonates admitted to the neonatal intensive care unit (NICU), Universiti Kebangsaan Malaysia Medical Centre (UKMMC) were screened with a two-step protocol using an automated auditory brain response (AABR) and/or Otoacoustic Emission and auditory brain response (ABR). Descriptive analysis was used for the prevalence of HL, degree of HL and number of risk factors per infant.
Results: A total of 2713 babies underwent hearing screening in NICU was enrolled in this study. Two thousand six hundred eight (96%) babies passed the screening test and 214 (4%) babies required further diagnostic test. Only 105 (49%) babies completed diagnostic tests. Out of 105 babies, 40 (38.1%) babies had HL. Mild HL was the commonest HL with 22 (55%), moderate HL was in seven babies (17.5%), severe HL in two babies (5%), and profound HL in nine babies (22.5%). The presence of craniofacial anomalies was the only significant independent risk factor for HL with p<0.05 with an odds ratio of 0.105 CI 95% [0.028-0.389]. Of Babies with the presence of three or more risk factors, 100% of them had HL.There was an increased risk of hearing loss in those with craniofacial anomalies up to 11 times higher compared to those without such anomalies.
Conclusion: The prevalence of HL among the NICU babies was 1.5% and mild HL was the commonest degree of HL (55%).