Displaying publications 81 - 100 of 357 in total

Abstract:
Sort:
  1. Tahir M, Tahir B
    J Colloid Interface Sci, 2021 Jun;591:20-37.
    PMID: 33588310 DOI: 10.1016/j.jcis.2021.01.099
    Constructing efficient structured materials for artificial photosynthesis of CO2 is a promising strategy to produce renewable fuels in addition of mitigating greenhouse effect. In this work, 2D porous g-C3N4 (PCN) coupled exfoliated 3D Ti3C2TA MXene (TiC) nanosheets with TiO2 NPs in-situ growth was constructed in a single step through HF treatment approach. The different exfoliated TiC structures were successfully synthesized for adjusting HF etching time (24 h, 48 h and 96 h). With growing etchant time from 24 to 96 h, the amount of TiO2 produced was increased, but it has adverse effects on CO and CH4 production rate. The maximum production rates for CO and CH4 of 317.4 and 78.55 µmol g-1 h-1 were attained when the 10TiC-48/PCN was employed than using TiC-24/PCN, TiC-96/PCN and PCN composite samples, respectively. The performance of 10TiC-48/PCN composite for CO and CH4 evolution were 9.9 and 6.7 folds higher than using pristine PCN sample, respectively. The possible mechanism is assigned to porous structure with intimate contact enabling efficient charge carrier separation with the role of TiO2 NPs to work as a bridge to transport electrons towards MXene surface. Among the reducing agents, water was favorable for CO evolution, whereas, methanol-water system promoted CH4 production. All these findings confirm that heterojunction formation facilitates charges separation and can be further used in solar energy relating application.
    Matched MeSH terms: Graphite
  2. Saisahas K, Soleh A, Promsuwan K, Phonchai A, Mohamed Sadiq NS, Teoh WK, et al.
    J Pharm Biomed Anal, 2021 Feb 08;198:113958.
    PMID: 33662759 DOI: 10.1016/j.jpba.2021.113958
    A portable electrochemical sensor was developed to determine xylazine in spiked beverages by adsorptive stripping voltammetry (AdSV). The sensor was based on a graphene nanoplatelets-modified screen-printed carbon electrode (GNPs/SPCE). The electrochemical behavior of xylazine at the GNPs/SPCE was an adsorption-controlled irreversible oxidation reaction. The loading of graphene nanoplatelets (GNPs) on the modified SPCE, electrolyte pH, and AdSV accumulation potential and time were optimized. Under optimal conditions, the GNPs/SPCE provided high sensitivity, linear ranges of 0.4-6.0 mg L-1 (r = 0.997) and 6.0-80.0 mg L-1 (r = 0.998) with a detection limit of 0.1 mg L-1 and a quantitation limit of 0.4 mg L-1. Repeatability was good. The accuracy of the proposed sensor was investigated by spiking six beverage samples at 1.0, 5.0, and 10.0 mg L-1. The recoveries from this method ranged from 80.8 ± 0.2-108.1 ± 0.3 %, indicating the good accuracy of the developed sensor. This portable electrochemical sensor can be used to screen for xylazine in beverage samples as evidence in cases of sexual assault or robbery.
    Matched MeSH terms: Graphite
  3. Ahmad Ashraful Hadi Abdul Ghafor, Nurhuda Elias, Suhaili Shams, Faizah Md Yasin, Sarchio, Seri Narti Edayu
    MyJurnal
    Gallic acid (GA) is a phenolic compound found in almost all plants and has been reported to possess powerful health benefits such as anti-oxidant, anti-inflammatory, anti-cancer, and anti-diabetic properties. However, GA suffers a short half-life when administered in vivo. Recent studies have employed graphene oxide (GO), a biocompatible and cost-effective graphene derivative, as a nanocarrier for GA. However, the toxicity effect of this formulated nano-compound has not been fully studied. Thus, the present study aims to evaluate the toxicity and teratogenicity of GA loaded GO (GAGO) against zebrafish embryogenesis to further advance the development of GA as a therapeutic agent. GAGO was exposed to zebrafish embryos (n ≥ 10; 24hr post fertilization (hpf)) at different concentrations (0-500 μg/ml). The development of zebrafish was observed and recorded twice daily for four days. The toxicity of pure GO and GA was also observed at similar concentrations. Distilled water was used as control throughout the experiment. A significantly high mortality rate, delayed hatching rate and low heartbeat were recorded in embryos exposed to GO at concentrations of ≥ 150 μg/ml at 48 hr (p
    Matched MeSH terms: Graphite
  4. Gupta M, Hawari HF, Kumar P, Burhanudin ZA, Tansu N
    Nanomaterials (Basel), 2021 Mar 03;11(3).
    PMID: 33802318 DOI: 10.3390/nano11030623
    The demand for carbon dioxide (CO2) gas detection is increasing nowadays. However, its fast detection at room temperature (RT) is a major challenge. Graphene is found to be the most promising sensing material for RT detection, owing to its high surface area and electrical conductivity. In this work, we report a highly edge functionalized chemically synthesized reduced graphene oxide (rGO) thin films to achieve fast sensing response for CO2 gas at room temperature. The high amount of edge functional groups is prominent for the sorption of CO2 molecules. Initially, rGO is synthesized by reduction of GO using ascorbic acid (AA) as a reducing agent. Three different concentrations of rGO are prepared using three AA concentrations (25, 50, and 100 mg) to optimize the material properties such as functional groups and conductivity. Thin films of three different AA reduced rGO suspensions (AArGO25, AArGO50, AArGO100) are developed and later analyzed using standard FTIR, XRD, Raman, XPS, TEM, SEM, and four-point probe measurement techniques. We find that the highest edge functionality is achieved by the AArGO25 sample with a conductivity of ~1389 S/cm. The functionalized AArGO25 gas sensor shows recordable high sensing properties (response and recovery time) with good repeatability for CO2 at room temperature at 500 ppm and 50 ppm. Short response and recovery time of ~26 s and ~10 s, respectively, are achieved for 500 ppm CO2 gas with the sensitivity of ~50 Hz/µg. We believe that a highly functionalized AArGO CO2 gas sensor could be applicable for enhanced oil recovery, industrial and domestic safety applications.
    Matched MeSH terms: Graphite
  5. Shi X, Karachi A, Hosseini M, Yazd MS, Kamyab H, Ebrahimi M, et al.
    Ultrason Sonochem, 2020 Nov;68:104460.
    PMID: 30712851 DOI: 10.1016/j.ultsonch.2019.01.018
    The aim of this study was ultrasound assisted removal of Ceftriaxone sodium (CS) based on CCD model. Using sonochemical synthesized Bi2WO6 implanted on graphitic carbon nitride/Multiwall carbon nanotube (g-C3N4/MWCNT/Bi2WO6). For this purpose g-C3N4/MWCNT/Bi2WO6 was synthesized and characterized using diverse approaches including XRD, FE-SEM, XPS, EDS, HRTEM, FT-IR. Then, the contribution of conventional variables including pH, CS concentration, adsorbent dosage and ultrasound contact time were studied by central composite design (CCD) under response surface methodology (RSM). ANOVA was employed to the variable factors, and the most desirable operational conditions mass provided. Drug adsorption yield of 98.85% obtained under these defined conditions. Through conducting five experiments, the proper prediction of the optimum point were examined. The respective results showed that RSD% was lower than 5% while the t-test confirmed the high quality of fitting. Langmuir isotherm equation fits the experimental data best and the removal followed pseudo-second order kinetics. The estimation of the experimentally obtained maximum adsorption capacities was 19.57 mg.g- of g-C3N4/MWCNT/Bi2WO6 for CS. Boundary layer diffusion explained the mechanism of removal via intraparticle diffusion.
    Matched MeSH terms: Graphite
  6. Aujara KM, Chieng BW, Ibrahim NA, Zainuddin N, Thevy Ratnam C
    Int J Mol Sci, 2019 Apr 18;20(8).
    PMID: 31003413 DOI: 10.3390/ijms20081910
    Gamma-ray radiation was used as a clean and easy method for turning the physicochemical properties of graphene oxide (GO) in this study. Silane functionalized-GO were synthesized by chemically grafting 3-aminopropyltriethoxysilane (APTES) and 3-glycidyloxypropyltrimethoxysilane (GPTES) onto GO surface using gamma-ray irradiation. This established non-contact process is used to create a reductive medium which is deemed simpler, purer and less harmful compared conventional chemical reduction. The resulting functionalized-GO were characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), thermogravimetric analysis (TGA), and Raman spectroscopy. The chemical interaction of silane with the GO surface was confirmed by FT-IR. X-ray diffraction reveals the change in the crystalline phases was due to surface functionalization. Surface defects of the GO due to the introduction of silane mioties was revealed by Raman spectroscopy. Thermogravimetric analysis of the functionalized-GO exhibits a multiple peaks in the temperature range of 200-650 °C which corresponds to the degradation of chemically grafted silane on the GO surface.
    Matched MeSH terms: Graphite
  7. Syed Ibrahim GP, Isloor AM, Ismail AF, Farnood R
    Sci Rep, 2020 04 23;10(1):6880.
    PMID: 32327672 DOI: 10.1038/s41598-020-63356-2
    In this paper, novel zwitterionic graphene oxide (GO) nanohybrid was synthesized using monomers [2-(Methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (SBMA) and N,N'-methylenebis(acrylamide) (MBAAm) (GO@poly(SBMA-co-MBAAm), and incorporated into polysulfone (PSF) hollow fiber membrane for the effectual rejection of dye from the wastewater. The synthesized nanohybrid was characterized using FT-IR, PXRD, TGA, EDX, TEM and zeta potential analysis. The occurrence of nanohybrid on the membrane matrix and the elemental composition were analyzed by XPS. The as-prepared tight ultrafiltration hollow fiber membrane exhibited high rejection of reactive black 5 (RB-5, 99%) and reactive orange 16 (RO-16, 74%) at a dye concentration of 10 ppm and pure water flux (PWF) of 49.6 L/m2h. Fabricated nanocomposite membranes were also studied for their efficacy in the removal of both monovalent (NaCl) and divalent salts (Na2SO4). The results revealed that the membrane possesses complete permeation to NaCl with less rejection of Na2SO4 (<5%). In addition, the nanocomposite membrane revealed outstanding antifouling performance with the flux recovery ratio (FRR) of 73% towards bovine serum albumin (BSA). Therefore, the in-house prepared novel nanocomposite membrane is a good candidate for the effective decolorization of wastewater containing dye.
    Matched MeSH terms: Graphite
  8. Arul P, Gowthaman NSK, John SA, Lim HN
    ACS Omega, 2020 Jun 23;5(24):14242-14253.
    PMID: 32596560 DOI: 10.1021/acsomega.9b03829
    Excess levels of nitrite ion in drinking water interact with amine functionalized compounds to form carcinogenic nitrosamines, which cause stomach cancer. Thus, it is indispensable to develop a simple protocol to detect nitrite. In this paper, a Cu-metal-organic framework (Cu-MOF) with graphene oxide (GO) composite was synthesized by ultrasonication followed by solvothermal method and then fabricated on a glassy carbon (GC) electrode for the sensitive and selective determination of nitrite contamination. The SEM image of the synthesized Cu-MOF showed colloidosome-like structure with an average size of 8 μm. Interestingly, the Cu-MOF-GO composite synthesized by ultrasonic irradiation followed by solvothermal process produce controlled size of 3 μm colloidosome-like structure. This was attributed to the formation of an exfoliated sheet-like structure of GO by ultrasonication in addition to the obvious influence of GO providing the oxygen functional groups as a nucleation node for size-controlled growth. On the other hand, the composite prepared without ultrasonication exhibited 6.6 μm size agglomerated colloidosome-like structures, indicating the crucial role of ultrasonication for the formation of size-controlled composites. XPS results confirmed the presence of Cu(II) in the as-synthesized Cu-MOF-GO based on the binding energies at 935.5 eV for Cu 2p3/2 and 955.4 eV for Cu 2p1/2. The electrochemical impedance studies in [Fe(CN)6]3-/4- redox couple at the composite fabricated electrode exhibited more facile electron transfer than that with Cu-MOF and GO modified electrodes, which helped to utilize Cu-MOF-GO for trace level determination of nitrite in environmental effluent samples. The Cu-MOF-GO fabricated electrode offered a superior sensitive platform for nitrite determination than the Cu-MOF and GO modified electrodes demonstrating oxidation at less positive potential with enhanced oxidation current. The present sensor detects nitrite in the concentration range of 1 × 10-8 to 1 × 10-4 M with the lowest limit of detection (LOD) of 1.47 nM (S/N = 3). Finally, the present Cu-MOF-GO electrode was successfully exploited for nitrite ion determination in lake and dye contaminated water samples.
    Matched MeSH terms: Graphite
  9. Lee ZY, Hawari HFB, Djaswadi GWB, Kamarudin K
    Materials (Basel), 2021 Jan 22;14(3).
    PMID: 33498992 DOI: 10.3390/ma14030522
    A tin oxide (SnO2) and reduced graphene oxide (rGO) hybrid composite gas sensor for high-performance carbon dioxide (CO2) gas detection at room temperature was studied. Since it can be used independently from a heater, it emerges as a promising candidate for reducing the complexity of device circuitry, packaging size, and fabrication cost; furthermore, it favors integration into portable devices with a low energy density battery. In this study, SnO2-rGO was prepared via an in-situ chemical reduction route. Dedicated material characterization techniques including field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM), energy dispersive X-ray (EDX) spectroscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy (XPS) were conducted. The gas sensor based on the synthesized hybrid composite was successfully tested over a wide range of carbon dioxide concentrations where it exhibited excellent response magnitudes, good linearity, and low detection limit. The synergistic effect can explain the obtained hybrid gas sensor's prominent sensing properties between SnO2 and rGO that provide excellent charge transport capability and an abundance of sensing sites.
    Matched MeSH terms: Graphite
  10. Razzaq L, Mujtaba MA, Soudagar MEM, Ahmed W, Fayaz H, Bashir S, et al.
    J Environ Manage, 2021 Mar 15;282:111917.
    PMID: 33453625 DOI: 10.1016/j.jenvman.2020.111917
    This study investigated the engine performance and emission characteristics of biodiesel blends with combined Graphene oxide nanoplatelets (GNPs) and 10% v/v dimethyl carbonate (DMC) as fuel additives as well as analysed the tribological characteristics of those blends. 10% by volume DMC was mixed with 30% palm oil biodiesel blends with diesel. Three different concentrations (40, 80 and 120 ppm) of GNPs were added to these blends via the ultrasonication process to prepare the nanofuels. Sodium dodecyl sulphate (SDS) surfactant was added to improve the stability of these blends. GNPs were characterised using Scanning Electron Microscope (SEM) and Fourier Transform Infrared (FTIR), while the viscosity of nanofuels was investigated by rheometer. UV-spectrometry was used to determine the stability of these nanoplatelets. A ratio of 1:4 GNP: SDS was found to produce maximum stability in biodiesel. Performance and emissions characteristics of these nanofuels have been investigated in a four-stroke compression ignition engine. The maximum reduction in BSFC of 5.05% and the maximum BTE of 22.80% was for B30GNP40DMC10 compared to all other tested blends. A reduction in HC (25%) and CO (4.41%) were observed for B30DMC10, while a reduction in NOx of 3.65% was observed for B30GNP40DMC10. The diesel-biodiesel fuel blends with the addition of GNP exhibited a promising reduction in the average coefficient of friction 15.05%, 8.68% and 3.61% for 120, 80 and 40 ppm concentrations compared to B30. Thus, combined GNP and DMC showed excellent potential for utilisation in diesel engine operation.
    Matched MeSH terms: Graphite
  11. Jacob AG, Wahab RA, Mahat NA
    Enzyme Microb Technol, 2021 Aug;148:109807.
    PMID: 34116744 DOI: 10.1016/j.enzmictec.2021.109807
    Oil palm leaves (OPL) silica (SiO2) can replace the energy-intensive, commercially produced SiO2. Moreover, the agronomically sourced biogenic SiO2 is more biocompatible and cost-effective enzyme support, which properties could be improved by the addition of magnetite (Fe3O4) and graphene oxide (GO) to yield better ternary support to immobilize enzymes, i.e., Candida rugosa lipase (CRL). This study aimed to optimize the Candida rugosa lipase (CRL immobilization onto the ternary OPL-silica-magnetite (Fe3O4)-GO (SiO2/Fe3O4/GO) support, for use as biocatalyst for ethyl valerate (EV) production. Notably, this is the first study detailing the CRL/SiO2/Fe3O4/GO biocatalyst preparation for rapid and high yield production of ethyl valerate (EV). AFM and FESEM micrographs revealed globules of CRL covalently bound to GL-A-SiO2/Fe3O4/GO; similar to Raman and UV-spectroscopy results. FTIR spectra revealed amide bonds at 3478 cm-1 and 1640 cm-1 from covalent interactions between CRL and GL-A-SiO2/Fe3O4/GO. Optimum immobilization conditions were 4% (v/v) glutaraldehyde, 8 mg/mL CRL, at 16 h stirring in 150 mM NaCl at 30 °C, offering 24.78 ± 0.26 mg/g protein (specific activity = 65.24 ± 0.88 U/g). The CRL/SiO2/Fe3O4/GO yielded 77.43 ± 1.04 % of EV compared to free CRL (48.75 ± 0.70 %), verifying the suitability of SiO2/Fe3O4/GO to hyperactivate and stabilize CRL for satisfactory EV production.
    Matched MeSH terms: Graphite
  12. Ikhsan NI, Rameshkumar P, Yusoff N, Huang NM
    J Nanosci Nanotechnol, 2019 Nov 01;19(11):7054-7063.
    PMID: 31039858 DOI: 10.1166/jnn.2019.16630
    Silver-reduced graphene oxide (Ag-rGO) nanohybrid was synthesized by applying a slight modification to the Turkevich method using trisodium citrate as a reducing and stabilizing agent to catalyze the non-enzymatic electrochemical detection of hydrogen peroxide (H₂O₂). Spherical silver nanoparticles (AgNPs) with an average particle size of 2.2 nm surfaced on reduced graphene oxide (rGO) sheets. Cyclic voltammograms (CV) obtained from glassy carbon (GC) electrode coated with Ag-rGO nanohybrid (4 mM) exhibited a peak at an overpotential of -0.52 V, with a larger faradaic current for the reduction of H₂O₂. Using the modified electrode for the linear sweep voltammetry (LSV) detection of H₂O₂, the detection limit and sensitivity were determined to be 4.8 μM (S/N ═ 3) and 0.0262 μA μM-1, respectively. The sensor appeared selective and stable towards H₂O₂ in the presence of possible interference, and it also demonstrated good recoveries of H₂O₂ concentration in real water samples.
    Matched MeSH terms: Graphite
  13. Ng JC, Tan CY, Ong BH, Matsuda A, Basirun WJ, Tan WK, et al.
    J Nanosci Nanotechnol, 2019 Nov 01;19(11):7236-7243.
    PMID: 31039881 DOI: 10.1166/jnn.2019.16717
    Small sized electrocatalysts, which can be obtained by rapid nucleation and high supersaturation are imperative for outstanding methanol oxidation reaction (MOR). Conventional microwave synthesis processes of electrocatalysts include ultrasonication, stirring, pH adjustment, and microwave irradiation of the precursor mixture. Ethylene glycol (EG), which serves as a reductant and solvent was added during the ultrasonication or stirring stage. However, this step and pH adjustment resulted in unintended multi-stage gradual nucleation. In this study, the microwave reduction approach was used to induce rapid nucleation and high supersaturation in order to fabricate small-sized reduced graphene oxide-supported palladium (Pd/rGO) electrocatalysts via the delayed addition of EG, elimination of the pH adjustment step, addition of sodium carbonate (Na₂CO₃), prior microwave irradiation of the EG mixed with Na₂CO₃, and addition of room temperature precursor mixture. Besides its role as a second reducing agent, the addition of Na₂CO₃ was primarily intended to generate an alkaline condition, which is essential for the high-performance of electrocatalysts. Moreover, the microwave irradiation of the EG and Na₂CO₃ mixture generated highly reactive free radicals that facilitate rapid nucleation. Meanwhile, the room temperature precursor mixture increased supersaturation. Results showed improved electrochemically active surface area (78.97 m² g-1, 23.79% larger), MOR (434.49 mA mg-1, 37.96% higher) and stability.
    Matched MeSH terms: Graphite
  14. Muthukumaran M, Dhinagaran G, Narayanan V, Raju T, Venkatachalam K, Karthika PC, et al.
    J Nanosci Nanotechnol, 2019 Nov 01;19(11):7215-7220.
    PMID: 31039878 DOI: 10.1166/jnn.2019.16671
    Graphene oxide/Cuprous oxide (GO/Cu₂O) composite is a visible light photocatalyst for the degradation of dyes. A simple and efficient approach for preparing GO/Cu₂O composite adopted in this study involves reducing cuprous oxide precursors in the presence of graphene oxide using an aqueous solution of pulp derived from banana fruit. The GO/Cu₂O composite was characterized by Fourier transform infrared spectroscopy (FT-IR), Diffused reflectance Ultraviolet visible spectroscopy (DRS UV-Vis), Raman spectroscopy and Field Emission Scanning electron microscopy (FE-SEM). Cu₂O particles were distributed randomly on the graphene oxide sheets due to the template effect of GO. The results showed higher photocatalytic activity for the composite (band gap 2.13 eV), for the degradation of the organic dyes (Methylene blue and Rhodamine-B). The enhanced photocatalytic activity is due to effective charge transfer from GO to Cu₂O, and high specific surface area which improves the effective separation of the generated electron-hole pairs. Our present study is inspired by a facile, low cost, green production of (GO/Cu₂O) composite whose photocatalytic activity can be extended to degradation of all other water-born textile dyes.
    Matched MeSH terms: Graphite
  15. Pham TV, Nguyen TT, Nguyen DT, Thuan TV, Bui PQT, Viet VND, et al.
    J Nanosci Nanotechnol, 2019 02 01;19(2):1122-1125.
    PMID: 30360214 DOI: 10.1166/jnn.2019.15926
    Recently, the graphite based materials have gained interest as excellent platforms to remove aqueous pollutants via adsorption routes. This is given that such materials possess large specific surface area and low density. In the present work, a comparative study of two facile and effective approaches is conventional thermal heating and microwave irradiation methods to fabricate expanded graphite from available flake graphite sources of Vietnam for oil-contaminated water purification. The as-prepared expanded graphite was characterized by using FT-IR, SEM, XRD and BET analysis. The results exhibited that expanded graphite has multilevel pore structures and the surface area of expanded graphite obtained from microwave irradiation and conventional heating was 147.5 (m²/g) and 100.97 (m²/g) under optimal processing conditions. The as-synthesized expanded graphite from the microwave irradiation method was found to have higher adsorption capacities for diesel oil, crude oil, and fuel oil compared to conventional heating method.
    Matched MeSH terms: Graphite
  16. Hashim R, Song TH, Muslim NZ, Yen TP
    Trop Life Sci Res, 2014 Dec;25(2):21-39.
    PMID: 27073597 MyJurnal
    This study aimed to assess the concentrations of cadmium (Cd), nickel (Ni) and lead (Pb) in the tissues of fish collected from the lower reach of the Kelantan River, Malaysia. Fishes were collected using gill nets during the dry and wet seasons. A total of 78 individual fish were caught and comprised 6 families, 11 genera and 13 species. The dorsal muscle was analysed using a graphite furnace Atomic Absorption Spectrometer (AAS). The mean concentration of Cd in Chitala chitala (0.076 mg/kg) was above the critical limit values of the European Commission (EC), World Health Organization (WHO) and Food and Agriculture Organization (FAO). The mean concentrations of Cd in Barbonymus gonionatus and Tachysurus maculatus were already at the level of concern, whereas the other species were approaching the limits of permissible levels. No fish samples were found to have a Ni level higher than the permissible limit of 0.5-0.6 mg/kg set by the WHO (1985). Osteochilus hasseltii (0.169 mg/kg) and T. maculatus (0.156 mg/kg) showed high Pb concentrations. The concentrations of heavy metals were found to be elevated in the wet season (p<0.05). Omnivorous fish were detected with elevated concentrations of Cd and Ni, whereas carnivorous fish had the highest concentration of Pb. The concentrations of Cd and Pb in fish tissues were positively correlated with fish weight (p<0.05). This study determined that the fish species caught in the Kelantan River were contaminated with non-essential metals (Cd, Ni and Pb). Nevertheless, the heavy metal concentration in the fish tissues, with the exception of C. chitala, O. hasseltii and T. maculatus, did not exceed the EC, FAO, Malaysian Food Act (MFA) or WHO guidelines.
    Matched MeSH terms: Graphite
  17. Chieng, Buong Woei, Nor Azowa Ibrahim, Wan Md Zin Wan Yunus, Mohd Zobir Hussein
    MyJurnal
    Poly(lactic acid) (PLA)-based nanocomposites filled with graphene nanoplatelets (xGnP) that contains epoxidized palm oil (EPO) as plasticizer were prepared by melt blending method. PLA was first plasticized by EPO to improve its flexibility and thereby overcome its problem of brittleness. Then, xGnP was incoporated into plasticized PLA to enhance its mechanical properties. Plasticized and nanofilled PLA nanocomposites (PLA/EPO/xGnP) showed improvement in the elongation at break by 3322% and 61% compared to pristine PLA and PLA/EPO, respectively. The use of EPO and xGnP increases the mobility of the polymeric chains, thereby improving the flexibility and plastic deformation of PLA. The nanocomposites also resulted in an increase of up to 26.5% in the tensile strength compared with PLA/EPO blend. XRD pattern showed the presence of peak around 26.5° in PLA/EPO/xGnP nanocomposites which corresponds to characteristic peak of graphene nanoplatelets. Plasticized PLA reinforced with xGnP showed that increasing the xGnP content triggers a substantial increase in thermal stability. Crystallinity of the nanocomposites as well as cold crystallization and melting temperature did not show any significant changes upon addition of xGnP. However, there was a significant decrease of glass transition temperature up to 0.3wt% of xGnP incorporation. The TEM micrograph of PLA/EPO/xGnP shows that the xGnP was uniformly dispersed in the PLA matrix and no obvious aggregation was observed.
    Matched MeSH terms: Graphite
  18. Rezvani-Eivari M, Amiri A, Baghayeri M, Ghaemi F
    J Chromatogr A, 2016 Aug 16.
    PMID: 27578405 DOI: 10.1016/j.chroma.2016.08.034
    The application of magnetized graphene (G) layers synthesized on the carbon nanofibers (CNFs) (m-G/CNF) was investigated as novel adsorbent for the magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). Six important parameters, affecting the extraction efficiency of PAHs, including: amount of adsorbent, adsorption and desorption times, type and volume of the eluent solvent and salt content of the sample were evaluated. The optimum extraction conditions were obtained as: 5min for extraction time, 20mg for sorbent amount, dichloromethane as desorption solvent, 1mL for desorption solvent volume, 5min for desorption time and 15% (w/v) for NaCl concentration. Good performance data were obtained at the optimized conditions. The calibration curves were linear over the concentration ranges from 0.012 to 100ngmL(-1) with correlation coefficients (r) between 0.9950 and 0.9967 for all the analytes. The limits of detection (LODs, S/N=3) of the proposed method for the studied PAHs were 0.004-0.03ngmL(-1). The relative standard deviations (RSDs) for five replicates at two concentration levels (0.1 and 50ngmL(-1)) of PAHs were ranged from 3.4 to 5.7%. Appropriate relative recovery values, in the range of 95.5-99.9%, were also obtained for the real water sample analysis.
    Matched MeSH terms: Graphite
  19. Mimala Arasaratnam, Zailina Hashim, Shamsul Bahari Shamsudin
    MyJurnal
    A cross-sectional study was conducted on 83 female electronics factory workers. The respondents comprised 50 exposed workers who use lead alloy solder and 33 unexposed workers. The objective of this study was to assess the lead exposure of these workers. Breathing zone were sampled using air sampling pumps. Dust samples were collected by wipe method. Venous blood collected and blood pressure were measured. All lead analyses were carried out with Graphite Furnace Atomic Absorption Spectrophotometer. The mean air lead for exposed workers (57 0. ± 0.93 μg/m³) was significantly higher than the unexposed workers (0.0067 ± 0.0045μg/m³) (p
    Matched MeSH terms: Graphite
  20. Ravikumar A, Panneerselvam P, Morad N
    ACS Appl Mater Interfaces, 2018 Jun 20;10(24):20550-20558.
    PMID: 29792319 DOI: 10.1021/acsami.8b05041
    In this paper, we propose a metal-polydopamine (MPDA) framework with a specific molecular probe which appears to be the most promising approach to a strong fluorescence quencher. The MPDA framework quenching ability toward various organic fluorophore such as aminoethylcoumarin acetate, 6-carboxyfluorescein (FAM), carboxyteramethylrhodamine, and Cy5 are used to establish a fluorescent biosensor that can selectively recognize Hg2+ and Ag+ ions. The fluorescent quenching efficiency was sufficient to achieve more than 96%. The MPDA framework also exhibits different affinities with ssDNA and dsDNA. In addition, the FAM-labeled ssDNA was adsorbed onto the MPDA framework, based on their interaction with the complex formed between MPDA frameworks/ssDNA taken as a sensing platform. By taking advantage of this sensor, highly sensitive and selective determination of Hg2+ and Ag+ ions is achieved through exonuclease III signal amplification activity. The detection limits of Hg2+ and Ag+ achieved to be 1.3 and 34 pM, respectively, were compared to co-existing metal ions and graphene oxide-based sensors. Furthermore, the potential applications of this study establish the highly sensitive fluorescence detection targets in environmental and biological fields.
    Matched MeSH terms: Graphite
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links