Displaying publications 81 - 100 of 276 in total

Abstract:
Sort:
  1. Hashim AN, Salleh MAAM, Sandu AV, Ramli MM, Yee KC, Mohd Mokhtar NZ, et al.
    Materials (Basel), 2021 Feb 05;14(4).
    PMID: 33562471 DOI: 10.3390/ma14040738
    The evolution of internal compressive stress from the intermetallic compound (IMC) Cu6Sn5 growth is commonly acknowledged as the key inducement initiating the nucleation and growth of tin (Sn) whisker. This study investigates the effect of Sn-0.7Cu-0.05Ni on the nucleation and growth of Sn whisker under continuous mechanical stress induced. The Sn-0.7Cu-0.05Ni solder joint has a noticeable effect of suppression by diminishing the susceptibility of nucleation and growth of Sn whisker. By using a synchrotron micro X-ray fluorescence (µ-XRF) spectroscopy, it was found that a small amount of Ni alters the microstructure of Cu6Sn5 to form a (Cu,Ni)6Sn5 intermetallic layer. The morphology structure of the (Cu,Ni)6Sn5 interfacial intermetallic layer and Sn whisker growth were investigated by scanning electron microscope (SEM) in secondary and backscattered electron imaging mode, which showed that there is a strong correlation between the formation of Sn whisker and the composition of solder alloy. The thickness of the (Cu,Ni)6Sn5 IMC interfacial layer was relatively thinner and more refined, with a continuous fine scallop-shaped IMC interfacial layer, and consequently enhanced a greater incubation period for the nucleation and growth of the Sn whisker. These verification outcomes proposes a scientifically foundation to mitigate Sn whisker growth in lead-free solder joint.
    Matched MeSH terms: X-Rays
  2. Hassan MI, Masnawi NN, Sultana N
    ASAIO J., 2017 9 14;64(3):415-423.
    PMID: 28901994 DOI: 10.1097/MAT.0000000000000655
    Conductive materials are potential candidates for developing bone tissue engineering scaffolds as they are nontoxic and can enhance bone tissue regeneration. Their bioactivity can be enhanced by depositing biomineralization in simulated body fluid (SBF). In the current study, a composite electrospun membrane made up of poly(lactic) acid, poly(3-hydroxybutyrate-co-3-hydroxyvalerate), and hydroxyapatite was fabricated using an electrospinning method. The fabricated membranes were dip-coated with a conductive polymer solution, poly(3,4-ethylenedioxythiophene) poly(4-styrenesulfonate), to induce conductivity. Characterization of the membranes based on characteristics such as morphology, chemical bonding, and wettability was conducted using scanning electron microscopy, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, attenuated total reflectance Fourier transform infrared spectroscopy, and contact angle measurement. From the results, biomineralization of both coated and noncoated composite membranes was observed on the surface of nanofibers after 21 days in SBF. The membranes provide a superhydrophilic surface as shown by the contact angle. In conclusion, this biomimetic electrospun composite membrane could be used to further support cell growth for bone tissue engineering application.
    Matched MeSH terms: X-Rays
  3. Hazrati KZ, Sapuan SM, Zuhri MYM, Jumaidin R
    Polymers (Basel), 2021 Feb 15;13(4).
    PMID: 33672030 DOI: 10.3390/polym13040584
    This study was driven by the stringent environmental legislation concerning the consumption and utilization of eco-friendly materials. Within this context, this paper aimed to examine the characteristics of starch and fibres from the Dioscorea hispida tuber plant to explore their potential as renewable materials. The extraction of the Dioscorea hispida starch and Dioscorea hispida fibres was carried out and the chemical composition, physical, thermal, morphological properties, and crystallinity were studied. The chemical composition investigations revealed that the Dioscorea hispida starch (DHS) has a low moisture t (9.45%) and starch content (37.62%) compared to cassava, corn, sugar palm, and arrowroot starches. Meanwhile, the Dioscorea hispida fibres (DHF) are significantly low in hemicellulose (4.36%), cellulose (5.63%), and lignin (2.79%) compared to cassava, corn hull and sugar palm. In this investigation the chemical, physical, morphological and thermal properties of the Dioscorea hispida fibre and Dioscorea hispida starch were examined by chemical composition investigation, scanning electron microscopy (SEM), particle size distribution, thermogravimetric analysis (TGA), X-ray powder diffraction (XRD), and Fourier transform infrared (FTIR), respectively. It was found that Dioscorea hispida waste is promising alternative biomass and sustainable material with excellent potential as a renewable filler material for food packaging applications.
    Matched MeSH terms: X-Rays
  4. Ho E
    Biomed Imaging Interv J, 2010 Jul-Sep;6(3):e8.
    PMID: 21611049 DOI: 10.2349/biij.6.3.e8
    When x-rays were first discovered, the harmful effects of radiation had to be manifest in the early users before they were known. Today, radiation protection and safety have been established and the effects of radiation, as well as its risks, are known. Even so, medical radiation, in particular the growth in the use of computed tomography (CT), has resulted in soaring radiation doses received by the population in general. Inappropriate use has resulted in overuse, overdose and, perhaps, overdiagnosis, especially when used in screening. In the quest to control and curb the use of procedures involving radiation, however, we must be careful not to provoke a pandemic of irrational fear of radiation. Overreaction to the overuse and overdose of radiation might deter patients from life-saving procedures.
    Matched MeSH terms: X-Rays
  5. Horry M, Chakraborty S, Pradhan B, Paul M, Gomes D, Ul-Haq A, et al.
    Sensors (Basel), 2021 Oct 07;21(19).
    PMID: 34640976 DOI: 10.3390/s21196655
    Lung cancer is the leading cause of cancer death and morbidity worldwide. Many studies have shown machine learning models to be effective in detecting lung nodules from chest X-ray images. However, these techniques have yet to be embraced by the medical community due to several practical, ethical, and regulatory constraints stemming from the "black-box" nature of deep learning models. Additionally, most lung nodules visible on chest X-rays are benign; therefore, the narrow task of computer vision-based lung nodule detection cannot be equated to automated lung cancer detection. Addressing both concerns, this study introduces a novel hybrid deep learning and decision tree-based computer vision model, which presents lung cancer malignancy predictions as interpretable decision trees. The deep learning component of this process is trained using a large publicly available dataset on pathological biomarkers associated with lung cancer. These models are then used to inference biomarker scores for chest X-ray images from two independent data sets, for which malignancy metadata is available. Next, multi-variate predictive models were mined by fitting shallow decision trees to the malignancy stratified datasets and interrogating a range of metrics to determine the best model. The best decision tree model achieved sensitivity and specificity of 86.7% and 80.0%, respectively, with a positive predictive value of 92.9%. Decision trees mined using this method may be considered as a starting point for refinement into clinically useful multi-variate lung cancer malignancy models for implementation as a workflow augmentation tool to improve the efficiency of human radiologists.
    Matched MeSH terms: X-Rays
  6. Horry MJ, Chakraborty S, Pradhan B, Paul M, Zhu J, Loh HW, et al.
    Sensors (Basel), 2023 Jul 21;23(14).
    PMID: 37514877 DOI: 10.3390/s23146585
    Screening programs for early lung cancer diagnosis are uncommon, primarily due to the challenge of reaching at-risk patients located in rural areas far from medical facilities. To overcome this obstacle, a comprehensive approach is needed that combines mobility, low cost, speed, accuracy, and privacy. One potential solution lies in combining the chest X-ray imaging mode with federated deep learning, ensuring that no single data source can bias the model adversely. This study presents a pre-processing pipeline designed to debias chest X-ray images, thereby enhancing internal classification and external generalization. The pipeline employs a pruning mechanism to train a deep learning model for nodule detection, utilizing the most informative images from a publicly available lung nodule X-ray dataset. Histogram equalization is used to remove systematic differences in image brightness and contrast. Model training is then performed using combinations of lung field segmentation, close cropping, and rib/bone suppression. The resulting deep learning models, generated through this pre-processing pipeline, demonstrate successful generalization on an independent lung nodule dataset. By eliminating confounding variables in chest X-ray images and suppressing signal noise from the bone structures, the proposed deep learning lung nodule detection algorithm achieves an external generalization accuracy of 89%. This approach paves the way for the development of a low-cost and accessible deep learning-based clinical system for lung cancer screening.
    Matched MeSH terms: X-Rays
  7. Hossain MB, Habib SB, Hossain MS, Jolly YN, Kamal AHM, Idris MH, et al.
    Data Brief, 2020 Aug;31:105911.
    PMID: 32637507 DOI: 10.1016/j.dib.2020.105911
    Meghna River Estuary, the largest estuarine system (GBM, Ganges-Brahmaputra-Meghna) in Bangladesh, is a major spawning ground of national fish, Hilsha shad. In this study, we collected 24 surface sediment and 24 water samples from the entire lower estuary (4 sites, 3 sampling points from each site, 2 replicas from each sampling point) to detect trace/heavy metals. Sediment samples were collected from the top surface soil (0-5 cm) using Ekman grab sampler and water samples from 5 cm below the surface layer using plastic water bottles. After collection, sediment and water samples were preserved as necessary using HNO3 (for water). Immediately after reaching the laboratory, sediment samples were dried in an oven at 70°C until the constant weight gained. The metals were then analyzed using energy-dispersive X-ray fluorescence method (EDXRF) and calculated the metal concentrations. In total, 12 metals were detected and the average value (mg/Kg) of all metals for sediment samples followed the descending order of Fe > Ca > K >Ti >Sr >Zr >Rb> Cu > Zn >Pb >As > Ni, and for water the order (µg/mL) of Fe >Ti > Ca > Co >Mn > Ni > Zn >Sr > Cu > As > Se . Besides, several physicochemical parameters i.e. water pH, soil pH, temperature, salinity, dissolved oxygen, hardness, and alkalinity of the 12 sampling points were also measured in-situ using handheld instruments.
    Matched MeSH terms: X-Rays
  8. Hou ZP, Tang SY, Ji HR, He PY, Li YH, Dong XL, et al.
    Chin J Integr Med, 2021 Apr;27(4):280-285.
    PMID: 31872369 DOI: 10.1007/s11655-019-3209-1
    OBJECTIVE: To investigate the mechanistic basis for the attenuation of bone degeneration by edible bird's nest (EBN) in ovariectomized rats.

    METHODS: Forty-two female Sprage-Dawley rats were randomized into 7 groups (6 in each group). The ovariectomized (OVX) and OVX + 6%, 3%, and 1.5% EBN and OVX +estrogen groups were given standard rat chow alone, standard rat chow +6%, 3%, and 1.5% EBN, or standard rat chow +estrogen therapy (0.2mg/kg per day), respectively. The sham-operation group was surgically opened without removing the ovaries. The control group did not have any surgical intervention. After 12 weeks of intervention, blood samples were taken for serum estrogen, osteocalcin, and osteoprotegerin, as well as the measurement of magnesium, calcium abd zinc concentrations. While femurs were removed from the surrounding muscles to measure bone mass density using the X-ray edge detection technique, then collected for histology and estrogen receptor (ER) immunohistochemistry.

    RESULTS: Ovariectomy altered serum estrogen levels resulting in increased food intake and weight gain, while estrogen and EBN supplementation attenuated these changes. Ovariectomy also reduced bone ER expression and density, and the production of osteopcalcin and osteorotegerin, which are important pro-osteoplastic hormones that promote bone mineraliztion and density. Conversely, estrogen and EBN increased serum estrogen levels leading to increased bone ER expression, pro-osteoplastic hormone production and bone density (all P<0.05).

    CONCLUSION: EBN could be used as a safe alternative to hormone replacement therapys for managing menopausal complications like bone degeneration.

    Matched MeSH terms: X-Rays
  9. Husaini Salleh, Supian Samat, Mohd Khalid Matori, Muhammad Jamal Md Isa, Mohd Ramli Arshad, Shahrul Azlan Azizan, et al.
    MyJurnal
    Heel Effect is the well known phenomena in x-ray production. It contributes the effect to image
    formation and as well as scattered radiation. But there is paucity in the study related to heel effect.
    This study is for mapping and profiling the dose on the surface of water phantom by using mobile
    C-arm unit Toshiba SXT-1000A. Based on the result the dose profile is increasing up to at least
    about 57% from anode to cathode bound of the irradiated area. This result and information can be
    used as a guide to manipulate this phenomenon for better image quality and radiation safety for
    this specific and dedicated fluoroscopy unit.
    Matched MeSH terms: X-Rays
  10. Hussein AM, Sharifai AG, Alia OM, Abualigah L, Almotairi KH, Abujayyab SKM, et al.
    Sci Rep, 2024 Jan 04;14(1):534.
    PMID: 38177156 DOI: 10.1038/s41598-023-47038-3
    The most widely used method for detecting Coronavirus Disease 2019 (COVID-19) is real-time polymerase chain reaction. However, this method has several drawbacks, including high cost, lengthy turnaround time for results, and the potential for false-negative results due to limited sensitivity. To address these issues, additional technologies such as computed tomography (CT) or X-rays have been employed for diagnosing the disease. Chest X-rays are more commonly used than CT scans due to the widespread availability of X-ray machines, lower ionizing radiation, and lower cost of equipment. COVID-19 presents certain radiological biomarkers that can be observed through chest X-rays, making it necessary for radiologists to manually search for these biomarkers. However, this process is time-consuming and prone to errors. Therefore, there is a critical need to develop an automated system for evaluating chest X-rays. Deep learning techniques can be employed to expedite this process. In this study, a deep learning-based method called Custom Convolutional Neural Network (Custom-CNN) is proposed for identifying COVID-19 infection in chest X-rays. The Custom-CNN model consists of eight weighted layers and utilizes strategies like dropout and batch normalization to enhance performance and reduce overfitting. The proposed approach achieved a classification accuracy of 98.19% and aims to accurately classify COVID-19, normal, and pneumonia samples.
    Matched MeSH terms: X-Rays
  11. Hutagalung, Sabar D., Woon, Wu S., Khatijah A. Yaacob, Lockman, Zainovia
    MyJurnal
    P-type transparent conductive oxide of copper aluminum oxide (CuAlO2) thin films were prepared by using sol-gel method with nitrate solutions as starting precursor. Copper nitrate and aluminum nitrate were selected as raw materials that provide the copper and aluminum source. The CuAlO2 thin films were deposited on pre-cleaned silicon substrate by spin-coating technique. To study of phase formation of CuAlO2, as prepared sample was dried and subjected to heat treatment at various temperatures. The heat-treated samples were characterized by x-ray diffraction (XRD) and energy dispersive x-ray (EDX). From XRD analysis result found that CuAlO2 phase was formed after annealing at 1100 o C for 4 hrs. EDX result of annealed sample at 1100 o C shows composition of Cu and Al that indicate the possibility of forming CuAlO2.
    Matched MeSH terms: X-Rays
  12. Ibrahim N, Baqiah H, Abdullah M
    Sains Malaysiana, 2013;42:961-966.
    High quality indium oxide and iron doped indium oxide nanocrystalline films were prepared by the sol-gel method followed by a spin coating technique. The samples were characterized by an X-ray diffractometer, an atomic force microscopy and a UV-vis spectroscopy. All samples had good crystallinity with a preferred orientation in the (222) direction. The crystallite size increased from 12.1 nm for the pure sample to 16.1 nm for the sample with x=0.35 and then decreased to 12.1 nm for the sample with x=0.45. All samples contained nanometer grain sizes with a smooth surface. All films showed a high transmission of over 91% in the wavelength range of 200-800 nm.
    Matched MeSH terms: X-Rays
  13. Ibrahim N, Yusrianto E, Ibarahim Z
    Sains Malaysiana, 2012;41:1029-1035.
    In this study TiO2 films have been prepared using two different techniques i.e. sol-gel and electron gun evaporation (e-gun) techniques. The films were annealed at 300, 350 and 400oC in air. The microstructure study using field emission scanning electron microscope and x-ray diffractometer showed nanometer grains size and only the film prepared by sol-gel and annealed at 400oC has anatase phase while others are amorphous. To study the effect of the films (as buffer layer) onto the dielectric bolometer Ba0.6Sr 0.4TiO3 as distance sensor, sensors with the configuration of Al/BST/TiO2/RuO2/SiO2/Si were built. Two different measurements i.e. with and without infrared source were carried out to measure the sensitivity and repeatability of the sensors. The sensors which contained sol-gel TiO2 films gave reading for both type of measurements, indicating that the sensor can act as active and passive sensors. However, the sensors which contained e-gun TiO2 films only gave responses when the IR source was used, indicating that they can only act as passive sensors. The most sensitive sensor was TiO2 film prepared by sol gel and annealed at 350oC. In general sensors which contained TiO2 films prepared by sol gel showed good repeatability.
    Matched MeSH terms: X-Rays
  14. Ikumapayi OM, Akinlabi ET
    Data Brief, 2019 Feb;22:537-545.
    PMID: 30627604 DOI: 10.1016/j.dib.2018.12.067
    Coconut Shell (CS) as agricultural lignocellulosic biomaterial and agro-waste is predominantly available in India, Malaysia, Nigeria, Thailand, Sri Lanka, and Indonesia. It has proven to have effective durability characteristic, good abstractive resistance, high toughness, and good adsorption properties, and is most suitable for long standing use in many applications such as reinforcement, source of energy, fillers as well as activated carbon and its performance, efficiency and effectiveness depend wholly on whether is in form of nano-, micro-, and macro- particles. In this data, effects of milling time on morphological characteristics was experimented using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray (EDX), and X-Ray Fluorescence (XRF) analyses. The SEM images were taken at magnifications of 1.00kx, 2.00kx and 5.00kx which gives respective 50 µm, 20 µm and 10 µm in different milling time of 0, 20, 40 and 60 mins. Digital Vibratory Disc Milling Machine (VDMM) rated 380 V/50 Hz at 940 rpm was employed for the grinding and the morphology of the milled nanoparticles were characterised. It was revealed from the data collected that 0 min (i.e. 75 µm sieved) has the highest mean area value of 16.105 µm2 and area standard deviation of 200.738 µm2 with least value of a number of particle size distribution of 809 µm. In contrast, 60 mins milled has the lowest values for mean area and area standard deviation of 8.945 µm2 and 115.851 µm2 respectively with the highest number of particle size distribution of 2032 µm. It was observed that milling time increases the number of particle sizes distributions and reduces the area of particle size.
    Matched MeSH terms: X-Rays
  15. Islam MT, Samsuzzaman M, Islam MT, Kibria S, Singh MJ
    Sensors (Basel), 2018 Sep 05;18(9).
    PMID: 30189684 DOI: 10.3390/s18092962
    Microwave breast imaging has been reported as having the most potential to become an alternative or additional tool to the existing X-ray mammography technique for detecting breast tumors. Microwave antenna sensor performance plays a significant role in microwave imaging system applications because the image quality is mostly affected by the microwave antenna sensor array properties like the number of antenna sensors in the array and the size of the antenna sensors. In this paper, a new system for successful early detection of a breast tumor using a balanced slotted antipodal Vivaldi Antenna (BSAVA) sensor is presented. The designed antenna sensor has an overall dimension of 0.401λ × 0.401λ × 0.016λ at the first resonant frequency and operates between 3.01 to 11 GHz under 10 dB. The radiating fins are modified by etching three slots on both fins which increases the operating bandwidth, directionality of radiation pattern, gain and efficiency. The antenna sensor performance of both the frequency domain and time domain scenarios and high-fidelity factor with NFD is also investigated. The antenna sensor can send and receive short electromagnetic pulses in the near field with low loss, little distortion and highly directionality. A realistic homogenous breast phantom is fabricated, and a breast phantom measurement system is developed where a two antennas sensor is placed on the breast model rotated by a mechanical scanner. The tumor response was investigated by analyzing the backscattering signals and successful image construction proves that the proposed microwave antenna sensor can be a suitable candidate for a high-resolution microwave breast imaging system.
    Matched MeSH terms: X-Rays
  16. Izamin I, Rizal AM
    Med J Malaysia, 2012 Dec;67(6):606-9.
    PMID: 23770954 MyJurnal
    INTRODUCTION: Various studies in primary care and hospitalized patients have discouraged routine use of chest x-ray (CXR) in medical examination.
    PURPOSE: The study aims to determine the prevalence of abnormal routine CXR and cost of one CXR at a public health clinic and discuss the rationale of CXR in routine medical examination.
    METHODOLOGY: Data of patients who visited Klinik Kesihatan Bandar Kota Bharu (KKBKB), a public health clinic, from 1 January until 31 December 2010 were examined. The study used cross-sectional design. All patients who came for medical examination and CXR at KKBKB were included. Cost analysis was performed from the perspective of provider.
    FINDINGS: About 63.1% of 8315 CXR films in KKBKB were produced as part of routine medical examination. Prevalence of abnormal CXR was 0.25%. The cost of producing one CXR ranges from RM15.87 to RM32.34.
    DISCUSSION: Low yield from CXR screening and high cost of CXR are the main concern. CXR screening would also lead to unnecessary radiation; and false-positive screening resulting in physical risk, unwarranted anxiety and more expenditure. CXR screening is appropriately reserved for high-risk patients and those with relevant clinical findings.
    Matched MeSH terms: X-Rays
  17. Jalal TMT, Abdullah S, Wahab FA, Dir S, Naing NN
    Malays J Med Sci, 2017 Dec;24(6):75-82.
    PMID: 29379389 DOI: 10.21315/mjms2017.24.6.9
    Background: One of the six strategies developed by WHO, in order to stop Tuberculosis (TB) is addressing TB/HIV high-risk groups. This study aimed to determine the prevalence of successful TB treatment and factors associated with TB treatment success among TB/HIV co-infection patients in North-East Malaysia.
    Methods: A cross-sectional study was carried out in the a-year period from 2003 to 2012 by reviewing TB/HIV records in all hospitals and health clinics. The outcome of interest was treatment success as defined by Ministry of Health (MOH) when the patients was cured or completed TB treatment.
    Results: Out of 1510 total TB/HIV co-infection cases, 27.9% (95% CI: 25.2, 30.6) of the patients were having treatment success. A majority of TB/HIV co-infection cases were male (91.1%). Fifty-eight percent the patients were drug addicts and 6% were having positive tuberculin tests. The multiple logistic regression revealed that male (OR: 0.39, 95% CI: 0.22, 0.71) and positive tuberculin test result (OR: 2.61, 95% CI: 1.63, 4.19) were significantly associated with the treatment success of TB/HIV co-infection patients. Other factors such as age, comorbid, sputum smear and x-ray findings were not significantly factors in this study.
    Conclusion: Female patients and those with negative tuberculin test should be emphasised for successful tuberculosis treatment.
    Matched MeSH terms: X-Rays
  18. Jalilavi M, Zoveidavianpoor M, Attarhamed F, Junin R, Mohsin R
    Sci Rep, 2014;4:3645.
    PMID: 24413195 DOI: 10.1038/srep03645
    Formation of carbonate minerals by CO2 sequestration is a potential means to reduce atmospheric CO2 emissions. Vast amount of alkaline and alkali earth metals exist in silicate minerals that may be carbonated. Laboratory experiments carried out to study the dissolution rate in Pahang Sandstone, Malaysia, by CO2 injection at different flow rate in surficial condition. X-ray Powder Diffraction (XRD), Scanning Electron Microscope (SEM) with Energy Dispersive X-ray Spectroscopy (EDX), Atomic Absorption Spectroscopy (AAS) and weight losses measurement were performed to analyze the solid and liquid phase before and after the reaction process. The weight changes and mineral dissolution caused by CO2 injection for two hours CO2 bubbling and one week' aging were 0.28% and 18.74%, respectively. The average variation of concentrations of alkaline earth metals in solution varied from 22.62% for Ca(2+) to 17.42% for Mg(2+), with in between 16.18% observed for the alkali earth metal, potassium. Analysis of variance (ANOVA) test is performed to determine significant differences of the element concentration, including Ca, Mg, and K, before and after the reaction experiment. Such changes show that the deposition of alkali and alkaline earth metals and the dissolution of required elements in sandstone samples are enhanced by CO2 injection.
    Matched MeSH terms: X-Rays
  19. Jamal AbuAlRoos N, Azman MN, Baharul Amin NA, Zainon R
    Phys Med, 2020 Oct;78:48-57.
    PMID: 32942196 DOI: 10.1016/j.ejmp.2020.08.017
    PURPOSE: The main objective of this study was to evaluate the efficacy of tungsten carbide as new lead-free radiation shielding material in nuclear medicine by evaluating the attenuation properties.

    MATERIALS AND METHODS: The elemental composition of tungsten carbide was analysed using Field-Emission Scanning Electron Microscopy (FESEM) with energy dispersive X-ray (EDX). The purity of tungsten carbide was 99.9%, APS: 40-50 µm. Three discs of tungsten carbide was fabricated with thickness of 0.1 cm, 0.5 cm and 1.0 cm. Three lead discs with similar thickness were used to compare the attenuation properties with tungsten carbide discs. Energy calibration of gamma spectroscopy was performed by using 123I, 133Ba, 152Eu, and 137Cs. Gamma radiation from these sources were irradiated on both materials at energies ranging from 0.160 MeV to 0.779 MeV. The experimental attenuation coefficients of lead and tungsten carbide were compared with theoretical attenuation coefficients of both materials from NIST database. The half value layer and mean free path of both materials were also evaluated in this study.

    RESULTS: This study found that the peaks obtained from gamma spectroscopy have linear relationship with all energies used in this study. The relative differences between the measured and theoretical mass attenuation coefficients are within 0.19-5.11% for both materials. Tungsten carbide has low half value layer and mean free path compared to lead for all thickness at different energies.

    CONCLUSION: This study shows that tungsten carbide has high potential to replace lead as new lead-free radiation shielding material in nuclear medicine.

    Matched MeSH terms: X-Rays
  20. Jamil NH, Abdullah MMAB, Pa FC, Mohamad H, Ibrahim WMAW, Amonpattaratkit P, et al.
    Materials (Basel), 2021 Mar 10;14(6).
    PMID: 33801862 DOI: 10.3390/ma14061325
    Kaolin, theoretically known as having low reactivity during geopolymerization, was used as a source of aluminosilicate materials in this study. Due to this concern, it is challenging to directly produce kaolin geopolymers without pre-treatment. The addition of ground granulated blast furnace slag (GGBS) accelerated the geopolymerization process. Kaolin-GGBS geopolymer ceramic was prepared at a low sintering temperature due to the reaction of the chemical composition during the initial stage of geopolymerization. The objective of this work was to study the influence of the chemical composition towards sintering temperature of sintered kaolin-GGBS geopolymer. Kaolin-GGBS geopolymer was prepared with a ratio of solid to liquid 2:1 and cured at 60 °C for 14 days. The cured geopolymer was sintered at different temperatures: 800, 900, 1000, and 1100 °C. Sintering at 900 °C resulted in the highest compressive strength due to the formation of densified microstructure, while higher sintering temperature led to the formation of interconnected pores. The difference in the X-ray absorption near edge structure (XANES) spectra was related to the phases obtained from the X-ray diffraction analysis, such as akermanite and anothite. Thermal analysis indicated the stability of sintered kaolin-GGBS geopolymer when exposed to 1100 °C, proving that kaolin can be directly used without heat treatment in geopolymers. The geopolymerization process facilitates the stability of cured samples when directly sintered, as well as plays a significant role as a self-fluxing agent to reduce the sintering temperature when producing sintered kaolin-GGBS geopolymers.
    Matched MeSH terms: X-Rays
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links