OBJECTIVES: This study aimed to formulate FMTs using cocoa butter as a base and investigate the effect of various disintegrants and superdisintegrants on their characteristics.
METHODS: Cocoa butter-based FMTs were prepared via the fusion molding technique. Different disintegrants and superdisintegrants were added at varying concentrations and subjected to characterization. The optimal formulation was selected and incorporated with 10 mg memantine hydrochloride.
RESULTS: The optimal FMT formulation consisted of 340 mg cocoa butter, 75 mg starch, and 75 mg crospovidone, exhibiting a hardness of 17.12 ± 0.31 N and a disintegration time of 32.67 ± 0.17 s. Furthermore, FMTs demonstrated a faster release profile compared to the commercially available product, Ebixa. SEM micrographs revealed homogenous blending of individual ingredients within the cocoa butter matrix and FT-IR analysis confirmed the chemical stability of memantine hydrochloride in the formulation. The dissolution profile of F17 suggested that the drug in FMTs released faster compared to Ebixia. Memantine hydrochloride achieved 98.07% of drug release in FMTs at 10 min. Moreover, the prepared FMTs exhibited stability for at least 6 months.
CONCLUSION: The successful development of cocoa butter-based FMTs containing memantine hydrochloride highlights the potential of cocoa butter as viable alternative matrix-forming material for FMTs production. This innovative formulation offers patients a convenient alternative for medication administration.
OBJECTIVES: To evaluate the sensitivity of QLF and OCT in detecting initial dental erosion in vitro.
METHODS: 12 human incisors were embedded in resin except for a window on the buccal surface. Bonding agent was applied to half of the window, creating an exposed and non-exposed area. Baseline measurements were taken with QLF, OCT and surface microhardness. Samples were immersed in orange juice for 60 min and measurements taken stepwise every 10 min. QLF was used to compare the loss of fluorescence between the two areas. The OCT system, OCS1300SS (Thorlabs Ltd.), was used to record the intensity of backscattered light of both areas. Multiple linear regression and paired t test were used to compare the change of the outcome measures.
RESULTS: All 3 instruments demonstrated significant dose responses with the erosive challenge interval (p < 0.05) and a detection threshold of 10 min from baseline. Thereafter, surface microhardness demonstrated significant changes after every 10 min of erosion, QLF at 4 erosive intervals (20, 40, 50 and 60 min) while OCT at only 2 (50 and 60 min).
CONCLUSION: It can be concluded that OCT and QLF were able to detect demineralization after 10 min of erosive challenge and could be used to monitor the progression of demineralization of initial enamel erosion in vitro.