Displaying publications 1 - 20 of 40 in total

Abstract:
Sort:
  1. Woon KC, Thong YL
    J Ir Dent Assoc, 1991;37(1):15-7.
    PMID: 1885927
    This case report illustrates the successful management of a case of mutilated maxillary incisors in a 13 year old patient through a sequence of therapy designed to closely coordinate the various disciplines, endodontics, restorative dentistry and orthodontics, involved. Endodontics was directed towards the control of the infected pulp, restorative treatment was to reconstruct the broken down teeth in stages which were essential in the sequence of treatment, and orthodontics was involved in the achievement of functional occlusion and alignment. The comprehensive treatment approach combined to achieve satisfactory aesthetics and function.
    Matched MeSH terms: Orthodontics, Corrective*
  2. Abang Abdullah AA, Ruslan R, Mohd. Yashin SH
    Malaysian Dental Journal, 2011;32(1):17-20.
    MyJurnal
    Objective: To audit the amount and complexity of case load and the waiting time for orthodontic treatment in Orthodontic Department of Universiti Kebangsaan Malaysia (UKM).
    Materials and Methods: This study involved three waiting list records in Orthodontic department, UKM and 484 patients’ record were selected using Random Sampling technique. Demographic data of the patients were noted. Data on date of patient’s visit to ‘Klinik Rawatan Utama’ (KRU), Screening clinic and first orthodontic treatment (removable/fixed) clinics were also recorded. The severity of referred cases were graded using complexity scale (Russle et al, 1999).
    Results: Patients were mostly female (76%) with age ranging from 10 to 52 years old. 75% of the referred cases were complex cases. From the year 2002-2007, 35% were referred for removable and 65% were referred for fixed clinic. In average, orthodontic screening waiting time was 6.9 ± 2.5 month. Patient would received removable and fixed appliance treatment after 4.4 ± 1.0 months and 14.5 ± 9.8 months respectively.
    Conclusions: Most patients were referred to fixed waiting list. The waiting time from 2002 until 2007 for orthodontic treatment in UKM was longest for fixed followed by screening. The shortest waiting time was for the removable treatment.
    Study site: Orthodontic Department of Universiti Kebangsaan Malaysia (UKM)
    Matched MeSH terms: Orthodontics, Corrective
  3. Bapat RA, Chaubal TV, Joshi CP, Bapat PR, Choudhury H, Pandey M, et al.
    Mater Sci Eng C Mater Biol Appl, 2018 Oct 01;91:881-898.
    PMID: 30033323 DOI: 10.1016/j.msec.2018.05.069
    Oral cavity is a gateway to the entire body and protection of this gateway is a major goal in dentistry. Plaque biofilm is a major cause of majority of dental diseases and although various biomaterials have been applied for their cure, limitations pertaining to the material properties prevent achievement of desired outcomes. Nanoparticle applications have become useful tools for various dental applications in endodontics, periodontics, restorative dentistry, orthodontics and oral cancers. Off these, silver nanoparticles (AgNPs) have been used in medicine and dentistry due to its antimicrobial properties. AgNPs have been incorporated into biomaterials in order to prevent or reduce biofilm formation. Due to greater surface to volume ratio and small particle size, they possess excellent antimicrobial action without affecting the mechanical properties of the material. This unique property of AgNPs makes these materials as fillers of choice in different biomaterials whereby they play a vital role in improving the properties. This review aims to discuss the influence of addition of AgNPs to various biomaterials used in different dental applications.
    Matched MeSH terms: Orthodontics
  4. Haque S, Alam MK, Arshad AI
    Malays J Med Sci, 2015 Jan-Feb;22(1):4-11.
    PMID: 25892945 MyJurnal
    In the contemporary era, the demand for orthodontic treatment is ever rising. Orthodontic treatment duration can range from a year to a few years. Our aim is to assess the available techniques of categorising treatment effectiveness in patients with cleft lip and palate (CLP) and to study their effect on improvement of treatment outcomes. The electronic databases including Medline-PUBMED, Science Direct, and ISI Web of Knowledge were searched from 1987 to 2013, and 40 311 relevant articles were found. Of these, we identified 22 articles including original articles as well as literature reviews. The different parameters and indices that are applied to speed-up orthodontic treatment outcomes in patients with CLP were identified as the GOSLON Yardstick, 5-year-old index, EUROCRAN index, Huddart Bodenham system, modified Huddart Bodenham system, GOAL Yardstick and, Bauru-Bilateral Cleft Lip and Palate Yardstick. This overview can create better awareness regarding the uses, advantages, and disadvantages of the different indices. It can enable better assessment and provide the impetus needed for a sustained upgrade in the standards of care for CLP in daily orthodontics.
    Matched MeSH terms: Orthodontics
  5. Wong KF, Lam XY, Jiang Y, Yeung AWK, Lin Y
    Head Face Med, 2023 Aug 23;19(1):38.
    PMID: 37612673 DOI: 10.1186/s13005-023-00383-0
    BACKGROUND: The application of artificial intelligence (AI) in orthodontics and orthognathic surgery has gained significant attention in recent years. However, there is a lack of bibliometric reports that analyze the academic literature in this field to identify publishing and citation trends. By conducting an analysis of the top 100 most-cited articles on AI in orthodontics and orthognathic surgery, we aim to unveil popular research topics, key authors, institutions, countries, and journals in this area.

    METHODS: A comprehensive search was conducted in the Web of Science (WOS) electronic database to identify the top 100 most-cited articles on AI in orthodontics and orthognathic surgery. Publication and citation data were obtained and further analyzed and visualized using R Biblioshiny. The key domains of the 100 articles were also identified.

    RESULTS: The top 100 most-cited articles were published between 2005 and 2022, contributed by 458 authors, with an average citation count of 22.09. South Korea emerged as the leading contributor with the highest number of publications (28) and citations (595), followed by China (16, 373), and the United States (7, 248). Notably, six South Korean authors ranked among the top 10 contributors, and three South Korean institutions were listed as the most productive. International collaborations were predominantly observed between the United States, China, and South Korea. The main domains of the articles focused on automated imaging assessment (42%), aiding diagnosis and treatment planning (34%), and the assessment of growth and development (10%). Besides, a positive correlation was observed between the testing sample size and citation counts (P = 0.010), as well as between the time of publication and citation counts (P 

    Matched MeSH terms: Orthodontics*
  6. Qamruddin I, Alam MK, Shahid F, Tanveer S, Mukhtiar M, Asim Z
    J Coll Physicians Surg Pak, 2016 May;26(5):390-3.
    PMID: 27225144 DOI: 2321
    OBJECTIVE: To determine and compare the cephalometric values among Pakistani males and females using commonly used sagittal skeletal measurements (ANB, Wits appraisal, Beta-angle) and newly developed cephalometric analyses (Yen-angle and W-angle).

    STUDY DESIGN: Observational, cross-sectional study.

    PLACE AND DURATION OF STUDY: Orthodontic Department of Baqai Medical University, Karachi, Pakistan, from August to October 2013.

    METHODOLOGY: Atotal of 209 pre-treatment lateral cephalometric radiographs of orthodontic patients were selected from departmental records, comprised of 92 males and 117 females. Radiographs were traced for measurements of ANB, Wits appraisal, Beta-angle, W-angle and Yen-angle. Patients were categorized into skeletal classes I, II, and III on the basis of performed measurements, incisor classification, and profile recorded from their records. Descriptive analysis was used to obtain median interquartile range in both the genders and Mann-Whitney U-test was used to observe gender dimorphism.

    RESULTS: Skeletal class II was the most prevalent type of malocclusion. There were no difference in the obtained measurements between males and females except the Wits appraisal and Beta-angle in class II patients, which showed significant difference in values (p < 0.05).

    CONCLUSION: Pakistani population has no significant different difference in the craniofacial morphology of males and females, with the exception of Wits-appraisal and Beta-angle in class II cases.

    Matched MeSH terms: Orthodontics
  7. Sinniah, Saraswathy D., Jones, Steven P., Georgiou, George, Cunningham, Susan J., Petrie, Aviva
    Compendium of Oral Science, 2016;3(1):17-24.
    MyJurnal
    used with bonded retainers. Setting: Department of Orthodontics, UCL Eastman Dental Institute, United Kingdom. Methods: Flowable composite resins (Transbond TM Supreme LV, StarFlowTM and Tetric EvoFlow®) and non -flowable control resin (TransbondTM LR) were made into cylinders prior to bonding to hydoxyapatite discs. They were then mounted into jigs and tested in the InstronTM Universal Testing Machine in both shear and tensile modes. Results: The highest mean shear bond strength was seen with StarFlow TM (14.09 MPa), which was significantly higher than both TransbondTM LR (9.48 MPa) and TransbondTM Supreme LV (8.20 MPa). The mean shear bond strength of Tetric EvoFlow® (11.86 MPa) was also significantly higher than TransbondTM Supreme LV. The highest mean tensile bond strength was seen with Tetric EvoFlow® (2.14 MPa), which was significantly higher than TransbondTM LR (1.15 MPa) and TransbondTM Supreme LV (0.61 MPa) but not significantly different to StarFlowTM (1.47 MPa). For shear loading, StarFlowTM had the highest 50th percentile survival estimate at 15.10 MPa, followed by Tetric EvoFlow® (13.00 MPa) and TransbondTM Supreme LV (7.50 MPa). TransbondTM LR had a 50th percentile estimate at 9.00 MPa. For tensile loading, Tetric EvoFlow® had the highest 50th percentile survival estimate at 2.50 MPa, followed by StarFlowTM (1.30 MPa) and TransbondTM Supreme LV (0.50 MPa). TransbondTM LR had a 50th percentile estimate at 1.00 MPa. Conclusions: Mean shear bond strengths for all of the resins were significantly higher than the mean tensile bond strengths. StarFlowTM and Tetric EvoFlow® could potentially be suitable clinical alternatives to TransbondTM LR due to its low viscosity flow characteristics and adequate shear and tensile bond strengths.
    Matched MeSH terms: Orthodontics
  8. Zainal Ariffin SH, Yamamoto Z, Zainol Abidin IZ, Megat Abdul Wahab R, Zainal Ariffin Z
    ScientificWorldJournal, 2011;11:1788-803.
    PMID: 22125437 DOI: 10.1100/2011/761768
    Tooth movement induced by orthodontic treatment can cause sequential reactions involving the periodontal tissue and alveolar bone, resulting in the release of numerous substances from the dental tissues and surrounding structures. To better understand the biological processes involved in orthodontic treatment, improve treatment, and reduce adverse side effects, several of these substances have been proposed as biomarkers. Potential biological markers can be collected from different tissue samples, and suitable sampling is important to accurately reflect biological processes. This paper covers the tissue changes that are involved during orthodontic tooth movement such as at compression region (involving osteoblasts), tension region (involving osteoclasts), dental root, and pulp tissues. Besides, the involvement of stem cells and their development towards osteoblasts and osteoclasts during orthodontic treatment have also been explained. Several possible biomarkers representing these biological changes during specific phenomenon, that is, bone remodelling (formation and resorption), inflammation, and root resorption have also been proposed. The knowledge of these biomarkers could be used in accelerating orthodontic treatment.
    Matched MeSH terms: Orthodontics*
  9. Mosleh MA, Baba MS, Malek S, Almaktari RA
    BMC Bioinformatics, 2016 Dec 22;17(Suppl 19):499.
    PMID: 28155649 DOI: 10.1186/s12859-016-1370-5
    BACKGROUND: Cephalometric analysis and measurements of skull parameters using X-Ray images plays an important role in predicating and monitoring orthodontic treatment. Manual analysis and measurements of cephalometric is considered tedious, time consuming, and subjected to human errors. Several cephalometric systems have been developed to automate the cephalometric procedure; however, no clear insights have been reported about reliability, performance, and usability of those systems. This study utilizes some techniques to evaluate reliability, performance, and usability metric using SUS methods of the developed cephalometric system which has not been reported in previous studies.

    METHODS: In this study a novel system named Ceph-X is developed to computerize the manual tasks of orthodontics during cephalometric measurements. Ceph-X is developed by using image processing techniques with three main models: enhancements X-ray image model, locating landmark model, and computation model. Ceph-X was then evaluated by using X-ray images of 30 subjects (male and female) obtained from University of Malaya hospital. Three orthodontics specialists were involved in the evaluation of accuracy to avoid intra examiner error, and performance for Ceph-X, and 20 orthodontics specialists were involved in the evaluation of the usability, and user satisfaction for Ceph-X by using the SUS approach.

    RESULTS: Statistical analysis for the comparison between the manual and automatic cephalometric approaches showed that Ceph-X achieved a great accuracy approximately 96.6%, with an acceptable errors variation approximately less than 0.5 mm, and 1°. Results showed that Ceph-X increased the specialist performance, and minimized the processing time to obtain cephalometric measurements of human skull. Furthermore, SUS analysis approach showed that Ceph-X has an excellent usability user's feedback.

    CONCLUSIONS: The Ceph-X has proved its reliability, performance, and usability to be used by orthodontists for the analysis, diagnosis, and treatment of cephalometric.

    Matched MeSH terms: Orthodontics/methods*
  10. Sivaloganathan V
    Plast Reconstr Surg, 1972 Feb;49(2):176-9.
    PMID: 5059332
    Matched MeSH terms: Orthodontics, Corrective
  11. Naili Hayati Binti Abdul Mukti, Noviaranny, Indah Yuri, Venkiteswaran, Annapurny, Sarah Haniza Binti Abdul Ghani
    MyJurnal
    In this paper, we discussed the characteristic of bimaxillary protrusion in different population. We also incorporated about aetiology and management of bimaxillary protrusion. It is importance to understand the characteristics of skeletal and dental of bimaxillary protrusions in a specific population, in order to decide whether to treat by orthodontic camouflage only, or combination with orthognathic surgery and orthodontics.
    Matched MeSH terms: Orthodontics
  12. Cons NC, Jenny J
    Int Dent J, 1994 Dec;44(6):489-94.
    PMID: 7851991
    The Standard DAI is an orthodontic index based on perceptions of dental aesthetics in the USA. The Standard DAI is a regression equation linking perceptions of the social acceptability of dental aesthetics with the objective intraoral measurements of ten occlusal traits. Since the Standard DAI is based on perceptions of dental aesthetics in the USA it can be used without modification only where perceptions of dental aesthetics are similar to those in the USA. This study was designed to determine whether perceptions of dental aesthetics of students in eleven diverse ethnic groups are similar to those of students in the USA. The same 25 stimuli (photographs of dental configurations, a subset of the 200 stimuli used in deriving the Standard DAI equation) were rated for dental aesthetics by Australian, Chinese, German, Japanese, Korean, Latvian, Native American, Singaporean Chinese, Singaporean Indian, Singaporean Malay, and Thai students. Their ratings were compared with the ratings of the same 25 stimuli by students in the USA. Spearman rank-order correlations ranged from 0.84 to 0.94. These correlations are sufficiently high to show that perceptions of dental aesthetics in all eleven ethnic groups are very similar to the perceptions of USA students. Therefore the Standard DAI can be used without modification in all eleven ethnic groups.
    Matched MeSH terms: Orthodontics
  13. Mohd Tahir N, Wan Hassan WN, Saub R
    Eur J Orthod, 2019 08 08;41(4):370-380.
    PMID: 30321319 DOI: 10.1093/ejo/cjy063
    OBJECTIVES: The aim of this study was to compare vacuum-formed thermoplastic retainers (VFRs) constructed on stone models (VFR-CV) and those constructed on three-dimensional (3D) printed models (VFR-3D) based on patients' perspective and post-treatment stability.

    STUDY DESIGN: The research was designed as a crossover, randomized control trial.

    MATERIALS AND METHODS: Subjects comprised patients receiving fixed appliances at a teaching institution and indicated for VFRs. Post-treatment stone models were scanned with a structured-light scanner. A fused deposition modelling machine was used to construct acrylonitrile-butadiene-styrene (ABS)-based replicas from the 3D scanned images. VFRs were fabricated on the original stone and printed models. Analysis comprised independent t-tests and repeated measures analysis of variance.

    RANDOMIZATION: Subjects were allocated to two groups using Latin squares methods and simple randomization. A week after debond, subjects received either VFR-CV first (group A) or VFR-3D first (group B) for 3 months, then the interventions were crossed over for another 3 months.

    BLINDING: In this single-blinded study, subjects were assigned a blinding code for data entry; data were analysed by a third party.

    OUTCOME MEASURES: The primary outcome measured was oral health-related quality of life (OHRQoL) based on Oral Health Impact Profile-14 (OHIP-14). Secondary outcome was post-treatment stability measured using Little's Irregularity Index (LII).

    RESULTS: A total of 30 subjects (15 in each group) were recruited but 3 dropped out. Analysis included 13 subjects from group A and 14 subjects from group B. Group A showed an increase in LII (P < 0.05) after wearing VFR-CV and VFR-3D, whereas group B had no significant increase in LII after wearing both VFRs. Both groups reported significant improvement in OHRQoL after the first intervention but no significant differences after the second intervention. LII changes and OHIP-14 scores at T2 and T3 between groups, and overall between the retainers were not significantly different. No harm was reported during the study.

    CONCLUSION: VFRs made on ABS-based 3D printed models showed no differences in terms of patients' OHRQoL and stability compared with conventionally made retainers.

    REGISTRATION: NCT02866617 (ClinicalTrials.gov).

    Matched MeSH terms: Orthodontics, Corrective
  14. Khoo, Kong Soo, Ong, Michael Ah Hup
    Ann Dent, 1998;5(1):-.
    MyJurnal
    The existence of numerous World Wide Web (WWW) sites devoted to dental education is proof that dental educators have been utilizing the pedagogical potential of information technology. Despite the availability of an immense quantity of information on the Internet, performing a search is often a complex, uncoordinated and time-consuming procedure, thus the usefulness of a guide on a topic of interest. Forty WWW sites devoted to dental education have been located using search engines. They were evaluated and classified as follows: guides, electronic publications, databases, patient education and undergraduate education; and according to subjects such as oral biology, morphology, histology, microbiology oral pathology, oral and maxillofacial surgery, radiology, periodontology, dental materials, orthodontics and neuroscience. The extensiveness and quality of some of these sites make them useful resources and knowledge banks for the teacher and the student.
    Matched MeSH terms: Orthodontics
  15. Abdul Rahim FS, Mohamed AM, Marizan Nor M, Saub R
    Acta Odontol Scand, 2014 Nov;72(8):999-1004.
    PMID: 25029211 DOI: 10.3109/00016357.2014.936036
    The purpose of this cross-sectional study was to assess the legal representatives' perceptions on dental care access of individuals with Down syndrome (DS) compared to their non-DS siblings in Peninsular Malaysia.
    Matched MeSH terms: Orthodontics, Corrective/statistics & numerical data
  16. Abohabib AM, Fayed MM, Labib AH
    J Orthod, 2018 09;45(3):149-156.
    PMID: 29874972 DOI: 10.1080/14653125.2018.1481710
    OBJECTIVE: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances.

    DESIGN: A split-mouth randomised clinical trial.

    SETTING: Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University.

    PARTICIPANTS: Fifteen subjects with mean age 20.9 (±3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction.

    METHODS: Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150 g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940 nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement.

    RESULTS: A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P > 0.05).

    CONCLUSIONS: Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction.

    Matched MeSH terms: Orthodontics*; Orthodontic Anchorage Procedures*
  17. Alyessary AS, Othman SA, Yap AUJ, Radzi Z, Rahman MT
    Int Orthod, 2019 03;17(1):12-19.
    PMID: 30732977 DOI: 10.1016/j.ortho.2019.01.001
    OBJECTIVE: This systematic review aims to determine the effects of non-surgical rapid maxillary expansion (RME) on breathing and upper airway structures.

    MATERIALS AND METHODS: An electronic search of the scientific literature from January 2005 to June 2016 was done using Web of Science, Dentistry & Oral Sciences Source and PubMed databases. A combination of search terms "rapid maxillary expansion", "nasal", "airway" and "breathing" were used. Studies that involved surgical or combined RME-surgical treatments and patients with craniofacial anomalies were excluded.

    RESULTS: The initial screening yielded a total of 183 articles. After evaluation of the titles, abstracts and accessing the full text, a total of 20 articles fulfilled both inclusion/exclusion criteria and possessed adequate evidence to be incorporated into this review.

    CONCLUSIONS: Non-surgical RME was found to improve breathing, increase nasal cavity geometry and decrease nasal airway resistance in children and adolescents.

    Matched MeSH terms: Orthodontics
  18. Alp S, Baka ZM
    Am J Orthod Dentofacial Orthop, 2018 Oct;154(4):517-523.
    PMID: 30268262 DOI: 10.1016/j.ajodo.2018.01.010
    INTRODUCTION: In this study, we aimed to determine the effect of regular probiotic consumption on microbial colonization in saliva in orthodontic patients and to comparatively evaluate the difference between the systemic consumption of probiotic products and the local application.

    METHODS: This study included 3 groups with 15 orthodontic patients in each. The control group included patients who had no probiotic treatment, the subjects in the kefir group consumed 2 × 100 ml of kefir (Atatürk Orman Ciftligi, Ankara, Turkey) per day, and the subjects in the toothpaste group brushed their teeth with toothpaste with probiotic content (GD toothpaste; Dental Asia Manufacturing, Shah Alam, Selangor, Malaysia) twice a day. Samples were collected at 3 times: beginning of the study, 3 weeks later, and 6 weeks later. The salivary flow rate, buffer capacity, and Streptococcus mutans and Lactobacillus levels in the saliva were evaluated. Chair-side kits were used to determine the S mutans and Lactobacillus levels.

    RESULTS: A statistically significant decrease was observed in the salivary S mutans and Lactobacillus levels in the kefir and toothpaste groups compared with the control group (P <0.05). A statistically significant increase was observed in the toothpaste group compared with the control and kefir groups in buffer capacity. Changes in the salivary flow rate were not statistically significant.

    CONCLUSIONS: The regular use of probiotics during fixed orthodontic treatment reduces the S mutans and Lactobacillus levels in the saliva.

    Matched MeSH terms: Orthodontic Appliances/adverse effects; Orthodontic Appliances/microbiology; Orthodontics*
  19. Esa R, Razak IA, Allister JH
    Community Dent Health, 2001 Mar;18(1):31-6.
    PMID: 11421403
    Data on malocclusion and orthodontic treatment need in Malaysia are limited. The purpose of this study was to evaluate malocclusion and orthodontic treatment need in a sample of 12-13-year-old schoolchildren using the Dental Aesthetic Index (DAI), and to assess the relationship between malocclusion and socio-demographic variables, perceptions of need for orthodontic treatment, aesthetic perception and social functioning.
    Matched MeSH terms: Orthodontics, Corrective/statistics & numerical data*
  20. Samson RS, Varghese E, Uma E, Chandrappa PR
    Contemp Clin Dent, 2018 3 31;9(1):10-14.
    PMID: 29599576 DOI: 10.4103/ccd.ccd_632_17
    Background: Fixed orthodontic retainers must be well retained on the tooth surfaces, allow physiologic movement of teeth and exert minimal forces on the teeth to be retained. Previous studies analyzed the bond strength and amount of deflection caused due to the debonding force but not the magnitude of force needed for unit deformation.

    Aims: This study aims to evaluate and compare the bond strength and load deflection rate (LDR) of three different fixed retainer wires.

    Materials and Methods: The wires were divided into three Groups: A - three-stranded twisted ligature wire, B - Bond-A-Braid (Reliance Orthodontics), and C - three-stranded twisted lingual retainer wire (3M Unitek). Twenty models were prepared for each group with a passive 15 mm long lingual retainer wire bonded to two lower incisors. An occlusogingival force was applied to the wire until it debonded. For LDR, three-point bending test was done at 0.5 mm deflection. These forces were measured using a Universal Instron Testing Machine.

    Statistical Analysis: Mean bond strength/LDR and pairwise comparisons were analyzed with one-way ANOVA and Tukey's honest significant differencepost hoctest, respectively.

    Results: Group C exhibited the highest mean bond strength and LDR of 101.17N and 1.84N, respectively. The intergroup comparisons were all statistically significant.

    Conclusion: Compared to the other two wire types, Group C might be better retained on the teeth due to its higher bond strength. With its relatively higher LDR value, it may resist deformation from occlusal forces, thereby reducing inadvertent tooth movement and yet remain flexible enough to allow physiologic tooth movements.

    Matched MeSH terms: Orthodontics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links