Materials and Methods: The synthesis was accomplished by the reaction of 2,3-dihydro-1,4-benzodioxin-6-amine (1) with 4-methylbenzenesulfonyl chloride (2) using 10% aqueous Na2CO3 to afford N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfonamide (3). Further the parent molecule 3 was reacted with different alkyl/aralkyl halides (4a-e) to achieve N-(alkyl/aralkyl)-N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfonamides (5a-e), using polar aprotic solvent; N,N-dimethylformamide (DMF) and catalytic amount of lithium hydride as base. The characterization of synthesized compounds was conducted by contemporary spectral techniques e.g., IR, 1H-NMR and EI-MS. Then these molecules were subjected to screening against various bacterial strains and their inhibitory potential against Lipoxygenase was also ascertained.
Results: The screening results against various Gram-positive and Gram-negative bacterial strains revealed that N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfonamide (3), N-(2-bromoethyl)-N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfonamide (5a) and N-(2-phenethyl)-N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfonamide (5b) showed good inhibitory activity as compared to standard Ciprofloxacin. Moreover, N-(3-phenylpropyl)-N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfonamide (5c) and N-(4-chlorobenzyl)-N-(2,3-dihydro-1,4-benzodioxin-6-yl)-4-methylbenzenesulfon-amide (5e) displayed decent inhibition against lipoxygenase enzyme relative to standard Baicalein.
Conclusion: On the basis of results obtained it can be concluded that the synthesized sulfonamides may provide an overall indispensable basis to introduce new drug candidates for the cure of inflammatory and other associated diseases.
METHODS: Two detection architectures, Single Shot Multibox Detector (SSD) and Faster Regional based Convolutional Neural Network (R-CNN) with various feature extractors were trained on echocardiography images from 33 patients. Thereafter, the models were tested on 10 echocardiography videos.
RESULTS: Faster R-CNN Inception v2 had shown the highest accuracy (98.6%) followed closely by SSD Mobilenet v2. In terms of speed, SSD Mobilenet v2 resulted in a loss of 46.81% in framesper- second (fps) during real-time detection but managed to perform better than the other neural network models. Additionally, SSD Mobilenet v2 used the least amount of Graphic Processing Unit (GPU) but the Central Processing Unit (CPU) usage was relatively similar throughout all models.
CONCLUSION: Our findings provide a foundation for implementing a convolutional detection system to echocardiography for medical purposes.
AIM: The purpose of this study is to perform a systematic review of the efficacy of Post-Mortem Computed Tomography (PMCT) scan compared with conventional autopsies gleaned from literature published in English between the year 2009 and 2016.
METHODOLOGY: A literature search was conducted in three databases, namely PubMed, MEDLINE, and Scopus. A total of 387 articles were retrieved, but only 21 studies were accepted after meeting the review criteria. Data, such as the number of victims, the number of radiologists and forensic pathologists involved, causes of death, and additional and missed diagnoses in PMCT scans were tabulated and analysed by two independent reviewers.
RESULTS: Compared with the conventional autopsy, the accuracy of PMCT scans in detecting injuries and causes of death was observed to range between 20% and 80%. The analysis also showed that PMCT had more advantages in detecting fractures, fluid in airways, gas in internal organs, major hemorrhages, fatty liver, stones, and bullet fragments. Despite its benefits, PMCT also could miss certain important lesion in a certain region such as cardiovascular injuries and minor vascular injuries.
CONCLUSIONS: This systematic review suggests that PMCT can replace most of the conventional autopsy in specific cases and is also a good complementary tool in most cases.
METHODS: A rapid online survey comprising 22 items was administered during the rapid outbreak of COVID-19 in Pakistan. Questions were focused on the prevention, transmission, clinical features, and control of COVID-19. In addition, the attitudes and practices of the participants were explored. Descriptive statistics, Mann-Whitney tests, Kruskal-Wallis tests, and regression analysis were carried out during data analysis.
RESULTS: A total of 1257 respondents participated in this study. Most of the respondents had good knowledge (good = 64.8%, average = 30.5%, poor = 4.7%) of COVID-19. Gender, marital status, education, and residence were observed to have a significant association with the knowledge score. A vast majority of the survey respondents (77.0%) believed that COVID-19 would be controlled successfully in Pakistan. The practices of wearing a mask (85.8%) and handwashing (88.1%) were common among the participants.
CONCLUSION: The participants demonstrated good knowledge and reasonable attitudes and practices toward most aspects of the COVID-19 outbreak. Improvements in certain areas could be made by mass-level education.
AIMS: To compare the efficacy of Gaviscon Advance (Reckitt Benckiser, UK) and a non-alginate antacid in post-supper suppression of the acid pocket and post-prandial reflux among obese participants.
METHODS: Participants underwent 48 h wireless and probe-based pH-metry recording of the acid pocket and lower oesophagus, respectively, and were randomised to single post-supper (10 pm) dose of either Gaviscon Advance or a non-alginate antacid on the second night. Primary outcomes were suppression of median pH of acid pocket and lower oesophagus, measured every 10-minutes post-supper for 1 h. Secondary outcomes were suppression of % time pH
Materials and Methods: The authors prepared C. striatus extract in chloroform-methanol solvents. Next, the authors took subgingival microbiological samples from 16 cats that had periodontal disease. The authors determined the antibacterial properties of C. striatus extract against the isolated bacteria using the disk diffusion method and a broth microdilution-based resazurin microtiter assay. Finally, the authors used the Vero cell line to evaluate the cytotoxic activity, and they assessed the cell availability using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay.
Results: The results showed weak antibacterial activity of C. striatus extract against Pseudomonas spp. and Escherichia coli. In addition, the authors found that minimum inhibition concentration values ranged between 400 and 500 mg/mL, and minimum bactericidal concentration values ranged between 650 and 550 mg/mL. However, the cytotoxic results were promising, showing that C. striatus extract increased the cell viability and growth when it was at a higher concentration. The extract also promotes growth and cell proliferation.
Conclusion: These findings suggest that C. striatus extract promoted cell proliferation in vitro and could be a plausible therapeutic wound healing alternative for periodontal disease in cats.
Methods: This is a cross-sectional study involving 156 TKA female patients with normal patellae. The patella height, width, thickness, medial and lateral articular facets' width and thickness, and the dome position were measured. The smallest implant size from 3 manufacturers was compared to the data obtained. Analysis using descriptive statistics was used to get the mean and median of anatomical patella dimensions, whereas the independent T test and one-way ANOVA test were used to compare the Malaysian female's patella dimensions with various implant sizes.
Results: The articular surface of the patella was found to have an oval shape with a width-height ratio of 1.31. The mean (SD) patella thickness, width, and height were 20.7 (1.85) mm, 40.7 (3.79) mm, and 31.3 (2.81) mm, respectively. Only 17.9% fit for smallest implant size from all 3 manufacturers. The oval-shape implant was suitable in 53.8% patients based on their width-height ratio. The dome position is 2.2 mm medial to centre.
Conclusion: These female patients have thinner and smaller patella, which are generally unable to accommodate patellar components based on the Caucasian database. Therefore, orthopaedic implant manufacturers should consider optimizing the thicknesses as well as widths of their patellar prostheses.