Displaying publications 21 - 40 of 44 in total

Abstract:
Sort:
  1. Mokhtar SU, Chin ST, Kee CL, Low MY, Drummer OH, Marriott PJ
    J Pharm Biomed Anal, 2016 Mar 20;121:188-196.
    PMID: 26808068 DOI: 10.1016/j.jpba.2016.01.034
    Application of gas chromatography-triple quadrupole mass spectrometry for identification, confirmation and quantification of 6 phosphodiesterase-5 (PDE-5) inhibitors (sildenafil, dimethylsildenafil, homosildenafil, thiosildenafil, thiodimethylsildenafil and thiohomosildenafil) in dietary supplements was investigated. The MS was operated in multiple reaction monitoring mode, for better sensitivity and selectivity. In this manner, the method is adequate to reduce background noise with less interference from co-eluting compounds in the samples. Two different ionisation techniques, electron ionisation (EI) and chemical ionisation (CI), were studied and compared. The chromatographic separation was performed on a short 10 m non-polar capillary column without any derivatisation step. This permitted fast analysis for all analogues with retention time less than 11 min, for both techniques. Use of backflushing can aid method retention time reduction and improves column maintenance. Evaluation of method validation included limit of detection (LOD), lower limit of quantitation (LLOQ), linearity, precision and recovery were performed for both EI and CI techniques. The LOD obtained varied from 0.03 to 1.50 μg/g and the LLOQ ranged from 0.10 to 5.00 μg/g. Good calibration linearity was obtained for all analogues for both techniques, with correlation coefficients (r(2)) higher than 0.99. Mean recoveries of all analogues using CI show higher values (83.4-108.8%) than that of EI (61.9-91.1%). The intra- and inter-assay precisions were evaluated for all analogues at spiked concentration of 10 μg/g and the relative standard deviation was less than 15% for both methods. These methods were then successfully applied to dietary supplement samples without prior derivatisation, confirming that the samples were adulterated with sildenafil and/or its analogues.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  2. Manickavasagam G, Saaid M, Lim V
    J Food Sci, 2024 Feb;89(2):1058-1072.
    PMID: 38221804 DOI: 10.1111/1750-3841.16903
    Volatile organic compounds in honey are known for their considerable impact on the organoleptic properties of honey, such as aroma, flavor, taste, and texture. The type and composition of volatile organic compounds are influenced by entomological, geographical, and botanical origins; thus, these compounds have the potential to be chemical markers. Sixty-two volatile compounds were identified using gas chromatography-mass spectrometry from 30 Heterotrigona itama (H. itama) honey samples from 3 different geographical origins. Hydrocarbons and benzene derivatives were the dominant classes of volatile organic compounds in the samples. Both clustering and discriminant analyses demonstrated a clear separation between samples from distant origins (Kedah and Perak), and the volcano plot supported it. The reliability and predictability of the partial least squares-discriminant analysis model from the discriminant analysis were validated using cross-validation (R2 : 0.93; Q2 : 0.83; accuracy: 0.97) and the permutation test (p  1.0) and the Kruskal-Wallis test (p 
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
  3. Man CN, Noor NM, Lajis R
    J Chromatogr A, 2011 Sep 28;1218(39):7055-60.
    PMID: 21872876 DOI: 10.1016/j.chroma.2011.08.037
    Sildenafil analogues have been found adulterated in herbal preparations and food products that claim to have natural aphrodisiacs. In this study, a gas chromatography-mass spectrometry (GC-MS) assay was developed for the screening and identification of thioketone analogues of sildenafil. Thiopyrazolopyrimidine, a precursor or a cleavage product of thioketone analogue, exhibited characteristic fragment ions of m/z 328 and m/z 299 was found to be the best marker to screen the presence of general thioketone analogues. Identification by GC-MS assay was rapid and specific as all the studied thioketones showed characteristic mass fragmentations including their intact molecular ions. The developed GC-MS assay had successfully identified thiosildenafil, thiohomosildenafil and thiodimethylsildenafil in herbal preparation and food products.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  4. Man CN, Noor NM, Harn GL, Lajis R, Mohamad S
    J Chromatogr A, 2010 Nov 19;1217(47):7455-9.
    PMID: 20950812 DOI: 10.1016/j.chroma.2010.09.064
    Tetrodotoxin (TTX), a toxic compound found in some puffers can cause death to humans through consumption. We have developed a simplified method for the screening of TTX in puffers using GC-MS. A puffer tissue of 0.5g was treated with 5mL of 0.1% acetic acid, followed by alkaline hydrolysis, LLE or liquid-liquid extraction and N-methyl-N-TMS-trifluoroacetamide derivatization. The developed method used only a small sample and solvent, simplified LLE and derivatization procedures and short chromatographic analysis (8.2min). All of these contribute to cost-saving, enhanced sample throughput and high sensitivity of the screening assay. The developed method was validated and proved to be within the acceptable range.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  5. Man CN, Nor NM, Lajis R, Harn GL
    J Chromatogr A, 2009 Nov 20;1216(47):8426-30.
    PMID: 19853256 DOI: 10.1016/j.chroma.2009.10.016
    Sildenafil and its analogues (tadalafil and vardenafil) are phosphodiesterase type 5 inhibitors used in the treatment of male erectile dysfunction. Some dietary supplements, herbal preparations and food products which claim to enhance male sexual function have been found to be adulterated with these drugs. In this study, a gas chromatograph-mass spectrometer (GC-MS) assay was developed for identification of the drugs. In addition to good and short chromatographic separation that can be achieved within 6 min by using a short 10 m capillary column, no prior sample clean-up before GC-MS analysis was required, thus making this assay a cost saving and rapid method. Furthermore, the assay is specific as the identification of sildenafil, tadalafil and vardenafil were done by detection of molecular ions; m/z 474, 389 and 488, [corrected] respectively, and several other characteristic ions resulted from the mass fragmentation of individual molecules. Using our currently developed assay, sildenafil and its analogues were successfully identified in food and herbal matrices.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  6. Man CN, Gam LH, Ismail S, Lajis R, Awang R
    PMID: 16908224
    Nicotine is a major addictive compound in cigarette. Its smoke is rapidly and extensively metabolized to several metabolites in human. Cotinine as a major metabolite of nicotine is commonly used as a biomarker to determine active and passive smokers. Cotinine has a longer half-life ( approximately 20 h) compared to nicotine ( approximately 2h). A simple, sensitive, rapid and high throughput GC-MS method was developed for simultaneous quantification of urinary nicotine and cotinine in passive and active smokers. In the sample preparation method, the analytes and internal standard were first basified and followed by liquid-liquid extraction. Upon completion, anhydrous sodium sulphate was added to the solvent mixture to trap moistures. The clear extract obtained was directly injected into GC-MS, operating under selective ion monitoring (SIM) mode. Calibration curves in the range of 0.5-5000 ng/mL of the analytes in urine matrix were established with linear correlation coefficients (r(2)) greater than 0.997. The limit of detection for both nicotine and cotinine were 0.20 ng/mL. The mean recoveries for nicotine and cotinine were 93.0 and 100.4%, respectively. The within- and between-assay accuracies were between 2.1 and 7.9% for nicotine and between 0.7 and 11.1% for cotinine. Within- and between-assay precisions of 3.3-9.5% for nicotine and 3.4-9.8% for cotinine were also achieved. The method can be used in routine assessment and monitoring of active smoking and exposure to environmental tobacco smoke. The applicability of the assay was demonstrated in a small-scale comparison study between smokers and non-smokers.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  7. Lawal A, Wong RCS, Tan GH, Abdulra'uf LB, Alsharif AMA
    J Chromatogr Sci, 2018 Aug 01;56(7):656-669.
    PMID: 29688338 DOI: 10.1093/chromsci/bmy032
    Fruits and vegetables constitute a major type of food consumed daily apart from whole grains. Unfortunately, the residual deposits of pesticides in these products are becoming a major health concern for human consumption. Consequently, the outcome of the long-term accumulation of pesticide residues has posed many health issues to both humans and animals in the environment. However, the residues have previously been determined using conventionally known techniques, which include liquid-liquid extraction, solid-phase extraction (SPE) and the recently used liquid-phase microextraction techniques. Despite the positive technological effects of these methods, their limitations include; time-consuming, operational difficulty, use of toxic organic solvents, low selective property and expensive extraction setups, with shorter lifespan of instrumental performances. Thus, the potential and maximum use of these methods for pesticides residue determination has resulted in the urgent need for better techniques that will overcome the highlighted drawbacks. Alternatively, attention has been drawn recently towards the use of quick, easy, cheap, effective, rugged and safe technique (QuEChERS) coupled with dispersive solid-phase extraction (dSPE) to overcome the setback challenges experienced by the previous technologies. Conclusively, the reviewed QuEChERS-dSPE techniques and the recent cleanup modifications justifiably prove to be reliable for routine determination and monitoring the concentration levels of pesticide residues using advanced instruments such as high-performance liquid chromatography, liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  8. Lasekan O, Khatib A, Juhari H, Patiram P, Lasekan S
    Food Chem, 2013 Dec 1;141(3):2089-97.
    PMID: 23870932 DOI: 10.1016/j.foodchem.2013.05.081
    The volatile compounds in four selected African star apple fruit (Chrysophyllum albidum) varieties were isolated and identified using the headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS). A total of 59 compounds were identified. Application of the aroma extract dilution analysis (AEDA) to the aroma distillates from the fruits revealed 45 odour-active compounds in the flavour dilution (FD) factor range of 4-128. Among them, the highest odour activities (FD factors) were determined for methylhexanoate, acetophenone and ethyl dodecanoate. Moreover, aroma lipophilicity appears to reflect molecular conformation. Further analysis of the similarities and differences between the fruit varieties in terms of the key odourants by the application of PLS-DA and PLS-regression coefficient showed strong positive correlation between the very sweet/sweet varieties and 10 key odourants. The odourants included ethyl acetate, acetyl methyl carbinol, methylhexanoate, sabinene, p-cymene, methylbenzoate, ethylbenzoate, geraniol, cis-α-bergomotene, acetophenone, and ethyl dodecanoate.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  9. Javadi N, Abas F, Abd Hamid A, Simoh S, Shaari K, Ismail IS, et al.
    J Food Sci, 2014 Jun;79(6):C1130-6.
    PMID: 24888400 DOI: 10.1111/1750-3841.12491
    Cosmos caudatus, which is known as "Ulam Raja," is an herbal plant used in Malaysia to enhance vitality. This study focused on the evaluation of the α-glucosidase inhibitory activity of different ethanolic extracts of C. caudatus. Six series of samples extracted with water, 20%, 40%, 60%, 80%, and 100% ethanol (EtOH) were employed. Gas chromatography-mass spectrometry (GC-MS) and orthogonal partial least-squares (OPLS) analysis was used to correlate bioactivity of different extracts to different metabolite profiles of C. caudatus. The obtained OPLS scores indicated a distinct and remarkable separation into 6 clusters, which were indicative of the 6 different ethanol concentrations. GC-MS can be integrated with multivariate data analysis to identify compounds that inhibit α-glucosidase activity. In addition, catechin, α-linolenic acid, α-D-glucopyranoside, and vitamin E compounds were identified and indicate the potential α-glucosidase inhibitory activity of this herb.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
  10. Ismail A, Toriman ME, Juahir H, Kassim AM, Zain SM, Ahmad WKW, et al.
    Mar Pollut Bull, 2016 Oct 15;111(1-2):339-346.
    PMID: 27397593 DOI: 10.1016/j.marpolbul.2016.06.089
    Extended use of GC-FID and GC-MS in oil spill fingerprinting and matching is significantly important for oil classification from the oil spill sources collected from various areas of Peninsular Malaysia and Sabah (East Malaysia). Oil spill fingerprinting from GC-FID and GC-MS coupled with chemometric techniques (discriminant analysis and principal component analysis) is used as a diagnostic tool to classify the types of oil polluting the water. Clustering and discrimination of oil spill compounds in the water from the actual site of oil spill events are divided into four groups viz. diesel, Heavy Fuel Oil (HFO), Mixture Oil containing Light Fuel Oil (MOLFO) and Waste Oil (WO) according to the similarity of their intrinsic chemical properties. Principal component analysis (PCA) demonstrates that diesel, HFO, MOLFO and WO are types of oil or oil products from complex oil mixtures with a total variance of 85.34% and are identified with various anthropogenic activities related to either intentional releasing of oil or accidental discharge of oil into the environment. Our results show that the use of chemometric techniques is significant in providing independent validation for classifying the types of spilled oil in the investigation of oil spill pollution in Malaysia. This, in consequence would result in cost and time saving in identification of the oil spill sources.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  11. Hossain MA, Shah MD, Sakari M
    Asian Pac J Trop Med, 2011 Aug;4(8):637-41.
    PMID: 21914542 DOI: 10.1016/S1995-7645(11)60162-4
    OBJECTIVE: To analyse the chemical composition of different extracts of Merremia borneensis (M. borneensis) by gas chromatography-mass spectrometry (GC-MS).

    METHODS: The dried leaves powder was extracted with methanol at room temperature by using Soxhlet extractor. Methanol crude extracts of M. borneensis were extrastel with hexane, chloroform, ethyl acetate and butanol.

    RESULTS: Qualitative analyses of various organic crude extracts showed that majority of these are flavonoids, terpeniods, alkaloids and glycosides. Most of the identified compounds by GC-MS are biologically important. Further the M. borneensis leaf possesses certain characteristics that can be ascribed to cultivation on a domestic plantation.

    CONCLUSIONS: The suitable extracts for respective compounds can be chosen on the basis of above GC-MS analysis. All the major compounds from different extracts are biologically active molecules. Thus the identification of a good number of compounds from various extracts M. borneensis might have some ecological significance.

    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  12. Halimah M, Tan YA, Aini K, Ismail BS
    J Environ Sci Health B, 2003 Jul;38(4):429-40.
    PMID: 12856925
    Improved methods for extraction and clean up of fluroxypyr residue in water have been established. Two methods of fluroxypyr extraction were used, namely, Direct Measurement of fluroxypyr and Concentration of fluroxypyr onto A Solid Phase Extraction (SPE) Adsorbent, followed by elution with solvent before determination of fluroxypyr. The recovery for Direct Measurement of fluroxypyr in water containing 8-100 microg L(-1), ranged from 86 to 110% with relative standard deviation of 0.7 to 2.15%. For the second method, three types of SPE were used, viz. C18, C18 end-capped and polyvinyl dibenzene (ISOLUTE ENV+). The procedure involved concentrating the analyte from fluroxypyr-spiked water at pH 3, followed by elution of the analyte with 4 mL of acentonitrile. The recovery of fluroxypyr from the spiked sample at 1 to 50 microg L(-1) after eluting through either C18 or C18 end-capped ranged from 40-64% (with relative standard deviation of 0.7 to 2.15) and 41-65% (with standard deviation of 1.52 to 11.9). The use of ISOLUTE ENV+, gave better results than the C18, C18 end-capped or the Direct Measurement Methods. The recovery and standard deviation of fluroxypyr from spiked water using ISOLUTE ENV+ ranged from 91-102% and 2.5 to 5.3, respectively.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  13. Gurdeep Singh HK, Yusup S, Quitain AT, Kida T, Sasaki M, Cheah KW, et al.
    Environ Sci Pollut Res Int, 2019 Nov;26(33):34039-34046.
    PMID: 30232774 DOI: 10.1007/s11356-018-3223-4
    Employment of edible oils as alternative green fuel for vehicles had raised debates on the sustainability of food supply especially in the third-world countries. The non-edible oil obtained from the abundantly available rubber seeds could mitigate this issue and at the same time reduce the environmental impact. Therefore, this paper investigates the catalytic cracking reaction of a model compound named linoleic acid that is enormously present in the rubber seed oil. Batch-scale experiments were conducted using 8.8 mL Inconel batch reactor having a cyclic horizontal swing span of 2 cm with a frequency of 60 cycles per minute at 450 °C under atmospheric condition for 90 min. The performance of HZSM-5, HBeta, HFerrierite, HMordenite and HY catalysts was tested for their efficiency in favouring gasoline range hydrocarbons. The compounds present in the organic liquid product were then analysed using GC-MS and classified based on PIONA which stands for paraffin, isoparaffin, olefin, naphthenes and aromatics respectively. The results obtained show that HZSM-5 catalyst favoured gasoline range hydrocarbons that were rich in aromatics compounds and promoted the production of desired isoparaffin. It also gave a higher cracking activity; however, large gaseous as by-products were produced at the same time.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
  14. Firus Khan AY, Ahmed QU, Nippun TS, Hilles A, Jalal TK, Teh LK, et al.
    J Ethnopharmacol, 2020 Nov 15;262:113138.
    PMID: 32726681 DOI: 10.1016/j.jep.2020.113138
    ETHNOPHARMACOLOGICAL RELEVANCE: Porcupine bezoar (PB) is used as folk medicine for various medical conditions including cancer treatment in Malaysia. However, its toxicity profile has never been thoroughly ascertained to confirm its safe nature as an efficacious traditional medicine in the treatment of cancer as well as other ailments.

    AIM OF THE STUDY: This study was aimed to reveal three different PBs' aqueous extracts(viz. PB-A, PB-B, PB-C) chemical constituent's profile using GC-MS analysis, anticancer property on A375, HeLa and MCF7 cancer cells, toxicity profile on zebrafish embryo morphology, EC50, LC50 and teratogenicity index.

    MATERIALS AND METHODS: PBs' extracts characterization was performed through GC-MS analysis, in vitro anticancer effect was carried out on A375, HeLa and MCF7 cancer cell lines and finally and toxicity properties on three different PBs aqueous extracts (viz. PB-A, PB-B, PB-C) were determined using zebrafish embryo model.

    RESULTS: The GC-MS analysis revealed 10 similar compounds in all PBs' extracts. Dilauryl thiodipropionate was found to be a major compound in all PBs' extracts followed by tetradecanoic acid. An in vitro anticancer study revealed PB extracts exerted median inhibition concentration (IC50) <50 μg/mL, on cancer cells viz. A375, HeLa and MCF7 with no significant toxicity on normal cells viz. NHDF cells. In vivo toxicity of PBs extracts found affecting tail detachment, hatching, craniofacial, brain morphology, soft tissues, edema, spinal, somites, notochord and cardiovascular system (brachycardia, disruption of blood circulation) deformities. The LC50 and EC50 demonstrated PB extracts effect as dose and time dependent with median concentration <150.0 μg/mL. Additionally, teratogenicity index (TI) viz. >1.0 revealed teratogenic property for PB extracts.

    CONCLUSIONS: The findings revealed that all three PBs aqueous extracts possessed anticancer activity and exhibited significant toxicological effects on zebrafish embryos with high teratogenicity index. Hence, its use as an anticancer agent requires further investigation and medical attentions to determine its safe dose.

    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  15. Fang TY, Praveena SM, deBurbure C, Aris AZ, Ismail SN, Rasdi I
    Chemosphere, 2016 Dec;165:358-368.
    PMID: 27665296 DOI: 10.1016/j.chemosphere.2016.09.051
    In recent years, environmental concerns over ultra-trace levels of steroid estrogens concentrations in water samples have increased because of their adverse effects on human and animal life. Special attention to the analytical techniques used to quantify steroid estrogens in water samples is therefore increasingly important. The objective of this review was to present an overview of both instrumental and non-instrumental analytical techniques available for the determination of steroid estrogens in water samples, evidencing their respective potential advantages and limitations using the Need, Approach, Benefit, and Competition (NABC) approach. The analytical techniques highlighted in this review were instrumental and non-instrumental analytical techniques namely gas chromatography mass spectrometry (GC-MS), liquid chromatography mass spectrometry (LC-MS), enzyme-linked immuno sorbent assay (ELISA), radio immuno assay (RIA), yeast estrogen screen (YES) assay, and human breast cancer cell line proliferation (E-screen) assay. The complexity of water samples and their low estrogenic concentrations necessitates the use of highly sensitive instrumental analytical techniques (GC-MS and LC-MS) and non-instrumental analytical techniques (ELISA, RIA, YES assay and E-screen assay) to quantify steroid estrogens. Both instrumental and non-instrumental analytical techniques have their own advantages and limitations. However, the non-instrumental ELISA analytical techniques, thanks to its lower detection limit and simplicity, its rapidity and cost-effectiveness, currently appears to be the most reliable for determining steroid estrogens in water samples.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  16. Diong SH, Mohd Yusoff NS, Sim MS, Raja Aziddin RE, Chik Z, Rajan P, et al.
    J Anal Toxicol, 2014 Nov-Dec;38(9):660-6.
    PMID: 25106416 DOI: 10.1093/jat/bku096
    Gas chromatography-mass spectrometry quantitative method was developed to monitor concentrations of methadone and its metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) in plasma and urine of patients. The developed method was simple, accurate and reproducible to quantify methadone and EDDP in plasma and urine samples in the concentration range of 15-1,000 and 50-2,000 ng/mL, respectively. The proposed analytical method was applied to plasma and urine samples obtained from 96 patients undergoing methadone maintenance treatment (MMT) with daily methadone doses of 2-120 mg/day. Urinary methadone excretion was observed to be significantly affected by pH, in which the ratio of methadone to EDDP was two times higher in acidic urine (P = 0.029). The findings of this study further enhance the guidelines for monitoring of methadone treatment among outpatients. Methadone-to-EDDP ratio in urine was found to be consistent at 24 and 4 h, hence suggesting the possibility that outpatients may be monitored with single urine sample in order to check for compliance. This study which provides data on peak concentrations of methadone and EDDP as well as the ratio of both compounds has added to the body of knowledge regarding pharmacokinetic properties of methadone among heroin-dependent patients under MMT.
    Study site: University Malaya Medical Centre (UMMC), HKL, University Malaya Centre for Addiction Sciences (UMCAS) and Rehabilitation Centre of Al-Rahman Mosque, Kuala Lumpur, Malaysia
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
  17. Chang ET, Lim BH
    Med J Malaysia, 1989 Jun;44(2):160-6.
    PMID: 2626126
    The abuse of phenylbutazone among rheumatoid arthritis patients has recently become a subject of interest. Unscrupulous manufacturers take advantage of the miraculous analgesic property of phenylbutazone and deliberately add this toxic drug in their preparations without declaring its presence on the label. In a recent survey, many such illicit preparations were seized from Chinese medical halls in Johor and sent to the Department of Chemistry, Johor Bahru for analysis. Here a Gas Chromatograph Mass Selective Detector (GC-MSD) method was developed for the determination of phenylbutazone in illicit traditional preparations.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  18. Chan KB, Pakiam C, Rahim RA
    Bull Narc, 2005;57(1-2):249-56.
    PMID: 21338025
    Recently, the abuse of ketum, an indigenous psychoactive plant, has received a lot of attention in Malaysia. To help national law enforcement agencies control its abuse, the laboratory of the Forensic Division has developed a procedure for its positive identification. Botanical identification may not be practical or conclusive, owing to the wide range of ketum materials available on the market, including dry macerated leaves, powdered leaves and drinks. In order to confirm that a substance is, in fact, ketum or that a preparation is derived from ketum, gas chromatography-mass spectrometry is used to definitively identify the presence of the psychoactive principle mnitragynine.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
  19. Baharum SN, Bunawan H, Ghani MA, Mustapha WA, Noor NM
    Molecules, 2010 Oct 12;15(10):7006-15.
    PMID: 20944520 DOI: 10.3390/molecules15107006
    The essential oil in leaves of Polygonum minus Huds., a local aromatic plant, were identified by a pipeline of gas chromatography (GC) techniques coupled with mass-spectrometry (MS), flame ionization detector (FID) and two dimensional gas chromatography time of flight mass spectrometry (GC x GC-TOF MS). A total of 48 compounds with a good match and high probability values were identified using this technique. Meanwhile, 42 compounds were successfully identified in this study using GC-MS, a significantly larger number than in previous studies. GC-FID was used in determining the retention indices of chemical components in P. minus essential oil. The result also showed the efficiency and reliability were greatly improved when chemometric methods and retention indices were used in identification and quantification of chemical components in plant essential oil.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  20. Ahmad Nizar NN, Nazrim Marikkar JM, Hashim DM
    J Oleo Sci, 2013;62(7):459-64.
    PMID: 23823911
    A study was conducted to differentiate lard, chicken fat, beef fat and mutton fat using Gas Chromatography Mass Spectrometry (GC-MS) and Elemental Analyzer-Isotope Ratio Mass Spectrometry (EA-IRMS). The comparison of overall fatty acid data showed that lard and chicken fat share common characteristics by having palmitic, oleic and linoleic acid as major fatty acids while beef and mutton fats shared common characteristics by possessing palmitic, stearic and oleic acid as major fatty acids. The direct comparisons among the fatty acid data, therefore, may not be suitable for discrimination of different animal fats. When the fatty acid distributional data was subjected to Principle Component Analysis (PCA), it was demonstrated that stearic, oleic and linoleic acids as the most discriminating parameters in the clustering of animal fats into four subclasses. The bulk carbon analysis of animal fats using EA-IRMS showed that determination of the carbon isotope ratios (δ¹³C) would be a good indicator for discriminating lard, chicken fat, beef fat and mutton fat. This would lead to a faster and more efficient method to ascertain the source of origin of fats used in food products.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links