Displaying publications 21 - 40 of 103 in total

Abstract:
Sort:
  1. Khoo HE, Azlan A, Ismail A, Abas F
    Molecules, 2012 Aug 14;17(8):9754-73.
    PMID: 22893021 DOI: 10.3390/molecules17089754
    Solid phase extraction (SPE) using Sep-Pak® cartridges is one of the techniques used for fractionation of antioxidant compounds in waste of dabai oil extraction (defatted dabai parts). The aim of this study was to determine the phenolic compounds and antioxidant capacity in crude extracts and several SPE fractions from methanolic extract of defatted dabai pulp and peel. Based on SPE, Sep-Pak® cyanopropyl and C₁₈ cartridges were used to fractionate the antioxidant-rich crude extracts into water and methanolic fractions. Analyzed using LC-MS, flavonoids, anthocyanins, saponin derivatives and other unknown antioxidative compounds were detected in the defatted dabai crude extracts and their SPE fractions. Anthocyanins were the major phenolic compounds identified in the defatted dabai peel and detected in most of the SPE fractions. Methanolic fractions of defatted dabai parts embraced higher total phenolics and antioxidant capacity than water fractions. This finding also revealed the crude extracts of defatted dabai peel have the most significant antioxidant properties compared to the methanolic and water fractions studied. The crude extract of defatted dabai parts remain as the most potent antioxidant as it contains mixture of flavonoids, anthocyanins and other potential antioxidants.
    Matched MeSH terms: Solid Phase Extraction*
  2. Kin CM, Huat TG
    J Chromatogr Sci, 2009 Sep;47(8):694-9.
    PMID: 19772747
    A headspace single-drop microextraction (HS-SDME) procedure is optimized for the analysis of organochlorine and organophosphorous pesticide residues in food matrices, namely cucumbers and strawberries by gas chromatography with an electron capture detector. The parameters affecting the HS-SDME performance, such as selection of the extraction solvent, solvent drop volume, extraction time, temperature, stirring rate, and ionic strength, were studied and optimized. Extraction was achieved by exposing 1.5 microL toluene drop to the headspace of a 5 mL aqueous solution in a 15-mL vial and stirred at 800 rpm. The analytical parameters, such as linearity, correlation coefficients, precision, limits of detection (LOD), limits of quantification (LOQ), and recovery, were compared with those obtained from headspace solid-phase microextraction (HS-SPME) and solid-phase extraction. The mean recoveries for all three methods were all above 70% and below 104%. HS-SPME was the best method with the lowest LOD and LOQ values. Overall, the proposed HS-SDME method is acceptable in the analysis of pesticide residues in food matrices.
    Matched MeSH terms: Solid Phase Extraction/methods*
  3. Muhamad H, Zainudin BH, Abu Bakar NK
    Food Chem, 2012 Oct 15;134(4):2489-96.
    PMID: 23442715 DOI: 10.1016/j.foodchem.2012.04.095
    Solid phase extraction (SPE) and dispersive solid-phase extraction (d-SPE) were compared and evaluated for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with an electron capture detector (GC-ECD). Several SPE sorbents such as graphitised carbon black (GCB), primary secondary amine (PSA), C(18), silica, and florisil were tested in order to minimise fat residues. The results show that mixed sorbents using GCB and PSA obtained cleaner extracts than a single GCB and PSA sorbents. The average recoveries obtained for each pesticide ranged between 81% and 114% at five fortification levels with the relative standard deviation of less than 7% in all cases. The limits of detection for these pesticides were ranged between 0.025 and 0.05 μg/g. The proposed method was applied successfully for the residue determination of both λ-cyhalothrin and cypermethrin in crude palm oil samples obtained from local mills throughout Malaysia.
    Matched MeSH terms: Solid Phase Extraction/methods*
  4. Ibrahim WA, Nodeh HR, Sanagi MM
    Crit Rev Anal Chem, 2016 Jul 03;46(4):267-83.
    PMID: 26186420 DOI: 10.1080/10408347.2015.1034354
    Graphene is a new carbon-based material that is of interest in separation science. Graphene has extraordinary properties including nano size, high surface area, thermal and chemical stability, and excellent adsorption affinity to pollutants. Its adsorption mechanisms are through non-covalent interactions (π-π stacking, electrostatic interactions, and H-bonding) for organic compounds and covalent interactions for metal ions. These properties have led to graphene-based material becoming a desirable adsorbent in a popular sample preparation technique known as solid phase extraction (SPE). Numerous studies have been published on graphene applications in recent years, but few review papers have focused on its applications in analytical chemistry. This article focuses on recent preconcentration of trace elements, organic compounds, and biological species using SPE-based graphene, graphene oxide, and their modified forms. Solid phase microextraction and micro SPE (µSPE) methods based on graphene are discussed.
    Matched MeSH terms: Solid Phase Extraction*
  5. Ayoib A, Hashim U, Gopinath SCB, Md Arshad MK
    Appl Microbiol Biotechnol, 2017 Nov;101(22):8077-8088.
    PMID: 28942548 DOI: 10.1007/s00253-017-8493-0
    This review covers a developmental progression on early to modern taxonomy at cellular level following the advent of electron microscopy and the advancement in deoxyribonucleic acid (DNA) extraction for expatiation of biological classification at DNA level. Here, we discuss the fundamental values of conventional chemical methods of DNA extraction using liquid/liquid extraction (LLE) followed by development of solid-phase extraction (SPE) methods, as well as recent advances in microfluidics device-based system for DNA extraction on-chip. We also discuss the importance of DNA extraction as well as the advantages over conventional chemical methods, and how Lab-on-a-Chip (LOC) system plays a crucial role for the future achievements.
    Matched MeSH terms: Solid Phase Extraction/methods
  6. Mohd Yusop AY, Xiao L, Fu S
    Talanta, 2019 Nov 01;204:36-43.
    PMID: 31357306 DOI: 10.1016/j.talanta.2019.05.078
    As a widely consumed beverage, coffee tends to be a target for intentional adulteration. This study describes the application of modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) coupled to liquid chromatography-high-resolution mass spectrometry (LC-HRMS) for simultaneous screening, identification, and quantification of undeclared phosphodiesterase 5 (PDE5) inhibitors in instant coffee premixes (ICPs). The mass spectrometer was operated in auto MS/MS acquisition for simultaneous MS and MS/MS experiments. Qualitative establishments from the suspected-target screening and targeted identification processes led to an unambiguous analyte assignment from the protonated molecule ([M+H]+) precursor ion which is subsequently used for quantification of 23 targeted PDE5 inhibitors. The analytical method validation covered specificity, linearity, range, accuracy, limit of detection (LOD), limit of quantification (LOQ), precisions, matrix effect (ME), and extraction recovery (RE). The specificity was established using the optimised chromatographic separation as well as the distinguishable [M+H]+ precursor ion. The linearity of each target analyte was demonstrated with a coefficient of determination (r2) of >0.9960 over the expected range of sample concentrations. The accuracy ranged from 88.1%-119.3% with LOD and LOQ of <70 ng/mL and 80 ng/mL, respectively. Excellent precisions were established within 0.4%-9.1% of the relative standard deviation. An insignificant ME within -5.2% to +8.7% was achieved using three different strategies of chromatography, sample extraction, and sample dilution. The RE was good for all target analytes within 84.7%-123.5% except for N-desethylacetildenafil at low (53.8%) and medium (65.1%) quality control levels. The method was successfully applied to 25 samples of ICPs where 17 of them were found to be adulterated with PDE5 inhibitors and their analogues. Further quantification revealed the total amount of these adulterants ranged from 2.77 to 121.64 mg per sachet.
    Matched MeSH terms: Solid Phase Extraction/methods
  7. Shafie MH, Yusof R, Gan CY
    Carbohydr Polym, 2019 Jul 15;216:303-311.
    PMID: 31047070 DOI: 10.1016/j.carbpol.2019.04.007
    The Box-Behnken design was applied to optimize the extraction of pectin from Averrhoa bilimbi (ABP) using deep eutectic solvents (DES). The four variables of extraction were percentage of DES (X1), extraction time (X2), temperature (X3), and molar ratio of DES components (X4). The quadratic regression equation was established as a predicted model with R2 value of 0.9375. The optimal condition was X1 = 3.74% (w/v), X2 = 2.5 h, X3 = 80 °C, and X4 = 1:1. No significant difference between the predicted (14.70%) and experimental (14.44%) maximum yield of sample was noted. Characterization of physico-chemical properties characterization of ABP was performed. The main components of ABP were galacturonic acids, arabinoses, and xyloses. ABP also showed good functional properties such as water holding capacity (3.70 g/g), oil holding capacity (2.40 g/g), and foaming capacity (133.33%). The results also showed that ABP exhibited free radical scavenging activity (41.46%) and ferric reducing antioxidant power (1.15 mM).
    Matched MeSH terms: Solid Phase Extraction/methods
  8. Amiri A, Ghaemi F
    J Chromatogr A, 2021 Jul 05;1648:462168.
    PMID: 33984648 DOI: 10.1016/j.chroma.2021.462168
    In this research, the Cu-based metal-organic framework (MOF-199) was fabricated and coated on the stainless steel mesh as substrates through sol-gel procedure. Then the coated substrates were placed in a small column known as solid-phase extraction cartridge. The SPE based coated stainless steel mesh coupled with high-performance liquid chromatography-UV detector (HPLC-UV) was used for the fast extraction, and quantification of non-steroidal anti-inflammatory drugs (NSAIDs) from human plasma and water samples. To find optimum extraction conditions, the impacts of effective parameters on analytical performance like sample pH, sample volume, type, and volume of desorption solvent were optimized. At the optimized conditions, calibration graphs of analytes were linear in the concentration range of 0.03-300 ng mL-1 for water samples, and 0.1-200 ng mL-1 for plasma samples. The correlation coefficients were in the range of 0.9938 to 0.9989. Also, the limits of detection (LODs) were from 0.01 to 0.02 ng mL-1 for water samples and 0.03 to 0.1 ng mL-1 for plasma samples. The cartridge repeatability was studied at different values, and the relative standard deviations (RSDs%) were achieved between 3.5 and 5.1%. Consequently, this procedure was successfully used in the extraction and detection of NSAIDs in real water and plasma samples with relative recoveries ranged from 93.6 to 99.6%.
    Matched MeSH terms: Solid Phase Extraction/methods*
  9. Veloo KV, Ibrahim NAS
    J Sep Sci, 2020 Aug;43(15):3027-3035.
    PMID: 32386268 DOI: 10.1002/jssc.201901237
    A new sol-gel hybrid methyltrimethoxysilane-chloropropyltriethoxysilane was prepared as sorbent for solid-phase extraction. The extraction efficiency of the prepared sol-gel hybrid methyltrimethoxysilane-chloropropyltriethoxysilane was assessed by using three selected organophosphorus pesticides, namely, chlorpyrifos, profenofos, and malathion. Gas chromatography-mass spectrometry was used for detection of organophosphorus pesticides. Several vital parameters were optimized to identify the best extraction conditions. Under the optimum extraction conditions, solid-phase extraction-methyltrimethoxysilane-chloropropyltriethoxysilane method showed good linearity range (0.05-1 μg/mL) with coefficient of determination more than 0.995. The limits of detection obtained were in the range of 0.01-0.07 μg/mL and limits of quantification ranging from 0.03 to 0.21 μg/mL. The limits of detection obtained for the developed method were 2.3-6.5× lower than the limits of detection of commercial octadecyl silica sorbent. Real samples analysis was carried out by applying the developed method on red apple and purple grape samples. The developed method exhibited good recoveries (88.33-120.7%) with low relative standard deviations ranging from 1.6 to 3.3% compared to commercial octadecyl silica sorbent, which showed acceptable recoveries (70.3-100.2%) and relative standard deviations (6.3-8.8%). The solid-phase extraction-methyltrimethoxysilane-chloropropyltriethoxysilane method is presented as an alternative extraction method for determination of organophosphorus pesticides.
    Matched MeSH terms: Solid Phase Extraction*
  10. Lawal A, Wong RCS, Tan GH, Abdulra'uf LB, Alsharif AMA
    J Chromatogr Sci, 2018 Aug 01;56(7):656-669.
    PMID: 29688338 DOI: 10.1093/chromsci/bmy032
    Fruits and vegetables constitute a major type of food consumed daily apart from whole grains. Unfortunately, the residual deposits of pesticides in these products are becoming a major health concern for human consumption. Consequently, the outcome of the long-term accumulation of pesticide residues has posed many health issues to both humans and animals in the environment. However, the residues have previously been determined using conventionally known techniques, which include liquid-liquid extraction, solid-phase extraction (SPE) and the recently used liquid-phase microextraction techniques. Despite the positive technological effects of these methods, their limitations include; time-consuming, operational difficulty, use of toxic organic solvents, low selective property and expensive extraction setups, with shorter lifespan of instrumental performances. Thus, the potential and maximum use of these methods for pesticides residue determination has resulted in the urgent need for better techniques that will overcome the highlighted drawbacks. Alternatively, attention has been drawn recently towards the use of quick, easy, cheap, effective, rugged and safe technique (QuEChERS) coupled with dispersive solid-phase extraction (dSPE) to overcome the setback challenges experienced by the previous technologies. Conclusively, the reviewed QuEChERS-dSPE techniques and the recent cleanup modifications justifiably prove to be reliable for routine determination and monitoring the concentration levels of pesticide residues using advanced instruments such as high-performance liquid chromatography, liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry.
    Matched MeSH terms: Solid Phase Extraction/methods*
  11. Rozi SKM, Nodeh HR, Kamboh MA, Manan NSA, Mohamad S
    J Oleo Sci, 2017 Jul 01;66(7):771-784.
    PMID: 28626137 DOI: 10.5650/jos.ess17016
    A novel adsorbent, palm fatty acid coated magnetic Fe3O4 nanoparticles (MNP-FA) was successfully synthesized with immobilization of the palm fatty acid onto the surface of MNPs. The successful synthesis of MNP-FA was further confirmed by X-Ray diffraction (XRD), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and Energy dispersive X-Ray spectroscopy (EDX) analyses and water contact angle (WCA) measurement. This newly synthesized MNP-FA was applied as magnetic solid phase extraction (MSPE) adsorbent for the enrichment of polycyclic aromatic hydrocarbons (PAHs), namely fluoranthene (FLT), pyrene (Pyr), chrysene (Cry) and benzo(a)pyrene (BaP) from environmental samples prior to High Performance Liquid Chromatography- Diode Array Detector (HPLC-DAD) analysis. The MSPE method was optimized by several parameters such as amount of sorbent, desorption solvent, volume of desorption solvent, extraction time, desorption time, pH and sample volume. Under the optimized conditions, MSPE method provided a low detection limit (LOD) for FLT, Pyr, Cry and BaP in the range of 0.01-0.05 ng mL(-1). The PAHs recoveries of the spiked leachate samples ranged from 98.5% to 113.8% with the RSDs (n = 5) ranging from 3.5% to 12.2%, while for the spiked sludge samples, the recoveries ranged from 81.1% to 119.3% with the RSDs (n = 5) ranging from 3.1% to 13.6%. The recyclability study revealed that MNP-FA has excellent reusability up to five times. Chromatrographic analysis demonstrated the suitability of MNP-FA as MSPE adsorbent for the efficient extraction of PAHs from environmental samples.
    Matched MeSH terms: Solid Phase Extraction/methods*
  12. Thongprapai P, Cheewasedtham W, Chong KF, Rujiralai T
    J Sep Sci, 2018 Dec;41(23):4348-4354.
    PMID: 30267469 DOI: 10.1002/jssc.201800441
    A magnetic nanographene oxide sorbent as a selective sorbent for the magnetic solid-phase extraction combined with high-performance liquid chromatography and fluorescence detection was developed and proved to be a robust method for zearalenone determination in corn samples. Optimum extraction of zearalenone (20 mg magnetic nanographene oxide sorbent, extraction for 15 min, desorption time of 15 min using 1 mL of 0.5% formic acid in methanol) resulted in low limits of detection (05 mg/L) and quantitation (0.13 mg/L) and good linearity range of 0.13-1.25 mg/L with the correlation coefficient of 0.9957. Acceptable recoveries (79.3-80.6%) with relative standard deviations below 4% and satisfactory intra- and interday precisions (2-7.4%) were achieved. Additionally, the proposed method has been proved to be good in several aspects: easily prepared sorbent with high affinity to zearalenone, convenient and fast procedure, and high extraction efficiency.
    Matched MeSH terms: Solid Phase Extraction*
  13. Marsin FM, Wan Ibrahim WA, Nodeh HR, Sanagi MM
    J Chromatogr A, 2020 Feb 08;1612:460638.
    PMID: 31676087 DOI: 10.1016/j.chroma.2019.460638
    Magnetic solid phase extraction (MSPE) employing oil-palm fiber activated carbon (OPAC) modified with magnetite (Fe3O4) and polypyrrole (OPAC-Fe3O4-PPy) was successfully used for the determination of two organochlorine pesticides (OCPs), namely endosulfan and dieldrin in environmental water samples. Analysis was performed using gas chromatography with micro-electron capture detection (GC-μECD). The effects of three preparation variables, namely Fe3O4:OPAC ratio, amount of pyrrole monomer, and amount of FeCl3 oxidant were optimized using Box-Behnken design (BBD) (R2 < 0.99, p-value < 0.001%). The optimum conditions were as follows: Fe3O4:OPAC ratio of 2:1 w/w, 1 g of FeCl3 and 100 μL of pyrrole monomer. The experimental results obtained agreed satisfactorily with the model prediction (> 90% agreement). Optimized OPAC-Fe3O4-PPy composite was characterized using field emission scanning electron microscope, vibrating sample magnetometer and Fourier transform infrared spectroscopy. Four numerical parameters of MSPE procedure was optimized using BBD. The significance of the MSPE parameters were salt addition > sample solution pH > extraction time and desorption time. Under the optimized conditions (extraction time: 90 s, desorption time: 10 min, salt: 0%, and pH: 5.8), the method demonstrated good linearity (25-1000 ng L-1) with coefficients of determination, R2 > 0.991, and low detection limits for both endosulfan (7.3 ng L-1) and dieldrin (8.6 ng L-1). The method showed high analyte recoveries in the range of 98.6-103.5% for environmental water samples. The proposed OPAC-Fe3O4-PPy MSPE method offered good features such as sustainability, simplicity, and rapid extraction.
    Matched MeSH terms: Solid Phase Extraction/methods*
  14. Ng NT, Kamaruddin AF, Wan Ibrahim WA, Sanagi MM, Abdul Keyon AS
    J Sep Sci, 2018 Jan;41(1):195-208.
    PMID: 28834218 DOI: 10.1002/jssc.201700689
    The efficiency of the extraction and removal of pollutants from food and the environment has been an important issue in analytical science. By incorporating inorganic species into an organic matrix, a new material known as an organic-inorganic hybrid material is formed. As it possesses high selectivity, permeability, and mechanical and chemical stabilities, organic-inorganic hybrid materials constitute an emerging research field and have become popular to serve as sorbents in various separaton science methods. Here, we review recent significant advances in analytical solid-phase extraction employing organic-inorganic composite/nanocomposite sorbents for the extraction of organic and inorganic pollutants from various types of food and environmental matrices. The physicochemical characteristics, extraction properties, and analytical performances of sorbents are discussed; including morphology and surface characteristics, types of functional groups, interaction mechanism, selectivity and sensitivity, accuracy, and regeneration abilities. Organic-inorganic hybrid sorbents combined with extraction techniques are highly promising for sample preparation of various food and environmental matrixes with analytes at trace levels.
    Matched MeSH terms: Solid Phase Extraction*
  15. Rashidi Nodeh H, Wan Ibrahim WA, Ali I, Sanagi MM
    Environ Sci Pollut Res Int, 2016 May;23(10):9759-73.
    PMID: 26850098 DOI: 10.1007/s11356-016-6137-z
    New-generation adsorbent, Fe3O4@SiO2/GO, was developed by modification of graphene oxide (GO) with silica-coated (SiO2) magnetic nanoparticles (Fe3O4). The synthesized adsorbent was characterized using Fourier transform infrared spectroscopy, X-ray diffractometry, energy-dispersive X-ray spectroscopy, and field emission scanning electron microscopy. The developed adsorbent was used for the removal and simultaneous preconcentration of As(III) and As(V) from environmental waters prior to ICP-MS analysis. Fe3O4@SiO2/GO provided high adsorption capacities, i.e., 7.51 and 11.46 mg g(-1) for As(III) and As(V), respectively, at pH 4.0. Adsorption isotherm, kinetic, and thermodynamic were investigated for As(III) and As(V) adsorption. Preconcentration of As(III) and As(V) were studied using magnetic solid-phase extraction (MSPE) method at pH 9.0 as the adsorbent showed selective adsorption for As(III) only in pH range 7-10. MSPE using Fe3O4@SiO2/GO was developed with good linearities (0.05-2.0 ng mL(-1)) and high coefficient of determination (R (2) = 0.9992 and 0.9985) for As(III) and As(V), respectively. The limits of detection (LODs) (3× SD/m, n = 3) obtained were 7.9 pg mL(-1) for As(III) and 28.0 pg mL(-1) for As(V). The LOD obtained is 357-1265× lower than the WHO maximum permissible limit of 10.0 ng mL(-1). The developed MSPE method showed good relative recoveries (72.55-109.71 %) and good RSDs (0.1-4.3 %, n = 3) for spring water, lake, river, and tap water samples. The new-generation adsorbent can be used for the removal and simultaneous preconcentration of As(III) and As(V) from water samples successfully. The adsorbent removal for As(III) is better than As(V).
    Matched MeSH terms: Solid Phase Extraction/methods
  16. Al'Abri AM, Mohamad S, Abdul Halim SN, Abu Bakar NK
    Environ Sci Pollut Res Int, 2019 Apr;26(11):11410-11426.
    PMID: 30805837 DOI: 10.1007/s11356-019-04467-w
    A novel porous coordination polymer adsorbent (BTCA-P-Cu-CP) based on a piperazine(P) as a ligand and 1,2,4,5-benzenetetracarboxylic acid (BTCA) as a linker was synthesized and magnetized to form magnetic porous coordination polymer (BTCA-P-Cu-MCP). Fourier transform infrared (FTIR), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), field emission scanning electron microscope(FESEM), energy-dispersive X-ray spectroscopy(EDS), CHN, and Brunauer-Emmett-Teller(BET) analysis were used to characterize the synthesized adsorbent. BTCA-P-Cu-MCP was used for removal and preconcentration of Pb(II) ions from environmental water samples prior to flame atomic absorption spectrometry(FAAS) analysis. The maximum adsorption capacity of BTCA-P-Cu-MCP was 582 mg g-1. Adsorption isotherm, kinetic, and thermodynamic parameters were investigated for Pb(II) ions adsorption. Magnetic solid phase extraction (MSPE) method was used for preconcentration of Pb(II) ions and the parameters influencing the preconcentration process have been examined. The linearity range of proposed method was 0.1-100 μg L-1 with a preconcentration factor of 100. The limits of detection and limits of quantification for lead were 0.03 μg L-1 and 0.11 μg L-1, respectively. The intra-day (n = 7) and inter-day (n = 3) relative standard deviations (RSDs) were 1.54 and 3.43% respectively. The recoveries from 94.75 ± 4 to 100.93 ± 1.9% were obtained for rapid extraction of trace levels of Pb(II) ions in different water samples. The results showed that the BTCA-P-Cu-MCP was steady and effective adsorbent for the decontamination and preconcentration of lead ions from the aqueous environment.
    Matched MeSH terms: Solid Phase Extraction/methods
  17. Chow YH, Yap YJ, Anuar MS, Tejo BA, Ariff A, Show PL, et al.
    PMID: 23911538 DOI: 10.1016/j.jchromb.2013.06.034
    A relationship is proposed for the interfacial partitioning of protein in poly(ethylene glycol) (PEG)-phosphate aqueous two-phase system (ATPS). The relationship relates the natural logarithm of interfacial partition coefficient, ln G to the PEG concentration difference between the top and bottom phases, Δ[PEG], with the equation ln G=AΔ[PEG]+B. Results showed that this relationship provides good fits to the partition of bovine serum albumin (BSA) in ATPS which is comprised of phosphate and PEG of four different molecular weight 1450g/mol, 2000g/mol, 3350g/mol and 4000g/mol, with the tie-line length (TLL) in the range of 44-60% (w/w) at pH 7.0. The decrease of A values with the increase of PEG molecular weight indicates that the correlation between ln G and Δ[PEG] decreases with the increase in PEG molecular weight and the presence of protein-polymer hydrophobic interaction. When temperature was increased, a non-linear relationship of ln G inversely proportional to temperature was observed. The amount of proteins adsorbed at the interface increased proportionally with the amount of BSA loaded whereas the partition coefficient, K remained relatively constant. The relationship proposed could be applied to elucidate interfacial partitioning behaviour of other biomolecules in polymer-salt ATPS.
    Matched MeSH terms: Solid Phase Extraction/instrumentation*
  18. Musa M, Wan Ibrahim WA, Mohd Marsin F, Abdul Keyon AS, Rashidi Nodeh H
    Food Chem, 2018 Nov 01;265:165-172.
    PMID: 29884368 DOI: 10.1016/j.foodchem.2018.04.020
    Graphene-magnetite composite (G-Fe3O4) was successfully synthesized and applied as adsorbent for magnetic solid phase extraction (MSPE) of two phenolic acids namely 4-hydroxybenzoic acid (4-HB) and 3,4-dihydroxybenzoic acid (3,4-DHB) from stingless bee honey prior to analysis using high performance liquid chromatography with ultraviolet-visible detection (HPLC-UV/Vis). Several MSPE parameters affecting extraction of these two acids were optimized. Optimum MSPE conditions were 50 mg of G-Fe3O4 adsorbent, 5 min extraction time at 1600 rpm, 30 mL sample volume, sample solution pH 0.5, 200 µL methanol as desorption solvent (5 min sonication assisted) and 5% w/v NaCl. The LODs (3 S/N) calculated for 4-HB and 3,4-DHB were 0.08 and 0.14 µg/g, respectively. Good relative recoveries (72.6-110.6%) and reproducibility values (RSD 
    Matched MeSH terms: Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods*
  19. Kamaruzaman S, Sanagi MM, Endud S, Wan Ibrahim WA, Yahaya N
    PMID: 24140656 DOI: 10.1016/j.jchromb.2013.09.017
    Mesoporous silica material, MCM-41, was utilized for the first time as an adsorbent in solid phase membrane tip extraction (SPMTE) of non-steroidal anti-inflammatory drugs (NSAIDs) in urine prior to high performance liquid chromatography-ultraviolet (HPLC-UV) analysis. The prepared MCM-41 material was enclosed in a polypropylene membrane tip and used as an adsorbent in SPMTE. Four NSAIDs namely ketoprofen, diclofenac, mefenamic acid and naproxen were selected as model analytes. Several important parameters, such as conditioning solvent, sample pH, salting-out effect, sample volume, extraction time, desorption solvent and desorption time were optimized. Under the optimum extraction conditions, the MCM-41-SPMTE method showed good linearity in the range of 0.01-10μg/mL with excellent correlation coefficients (r=0.9977-0.9995), acceptable RSDs (0.4-9.4%, n=3), good limits of detection (5.7-10.6μg/L) and relative recoveries (81.4-108.1%). The developed method showed a good tolerance to biological sample matrices.
    Matched MeSH terms: Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods*
  20. Mukhtar NH, See HH
    Anal Chim Acta, 2016 08 10;931:57-63.
    PMID: 27282751 DOI: 10.1016/j.aca.2016.04.032
    In this study, the potential for carbonaceous nanomaterials to be used as adsorbents for the mixed matrix membrane (MMM) microextraction and preconcentration of organic pollutants was demonstrated. For this method, multiwall carbon nanotubes (MWCNT) and single layer graphene (SLG) nanoparticles were individually incorporated through dispersion in a cellulose triacetate (CTA) polymer matrix to form a MWCNT-MMM and SLG-MMM, respectively. The prepared membranes were evaluated for the extraction of selected polycyclic aromatic hydrocarbons (PAHs) present in sewage pond water samples. The extraction was performed by dipping a small piece of membrane (7 mm × 7 mm) in a stirred 7.5 mL sample solution to initiate the analyte adsorption. This step was followed by an analyte desorption into 60 μL of methanol prior to high performance liquid chromatography (HPLC) analysis. When the optimum SLG-MMM microextraction technique was applied to spiked sewage pond water samples, the detection limit of the method for the PAHs were in the range of 0.02-0.09 ng/mL, with relative standard deviations of between 1.4% and 7.8%. Enrichment factors of 54-100 were achieved with relative recoveries of 99%-101%. A comparison was also made between the proposed approach and standard solid phase extraction using polymeric bonded octadecyl (C18) cartridges.
    Matched MeSH terms: Solid Phase Extraction
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links