Displaying publications 21 - 40 of 136 in total

Abstract:
Sort:
  1. Seow LL, Toh CG, Wilson NH
    Eur J Prosthodont Restor Dent, 2005 Jun;13(2):57-64.
    PMID: 16011232
    Existing literature suggests a relationship between the amount of remaining tooth structure and the fracture resistance of the restored endodontically treated tooth. This study investigated the amount of tooth structure remaining following various tooth preparations used in the restoration of the endodontically treated maxillary second premolar. Illustrations of the maxillary second premolar in buccopalatal, mesiodistal and occlusal sections were drawn to scale. Outlines of various intra- and extracoronal preparations were superim-posed on the illustrations to reveal the amount of tooth tissue remaining in each case. Preparations for a ceramic inlay, inlay with palatal cusp coverage and onlay left 2.0-2.5mm of tooth structure buccally and palatally. Following preparation for a metal-ceramic crown, approximately 1.0mm of tooth structure remained buccally, and between 1.6mm-1.8mm palatally. Preparation for an all-ceramic crown was observed to leave 1.0mm-1.2mm of tooth structure surrounding what remained of the endodontic access cavity. It was concluded that decisions as to the type of definitive restoration to restore the endodontically treated maxillary second premolar may be influenced, amongst other factors, by information on the amount of tooth tissue remaining following preparation.
    Matched MeSH terms: Metal Ceramic Alloys
  2. Rahman MNA, Zubir NSM, Leuveano RAC, Ghani JA, Mahmood WMFW
    Materials (Basel), 2014 Dec 02;7(12):7706-7721.
    PMID: 28788270 DOI: 10.3390/ma7127706
    The significant increase in metal costs has forced the electronics industry to provide new materials and methods to reduce costs, while maintaining customers' high-quality expectations. This paper considers the problem of most electronic industries in reducing costly materials, by introducing a solder paste with alloy composition tin 98.3%, silver 0.3%, and copper 0.7%, used for the construction of the surface mount fine-pitch component on a Printing Wiring Board (PWB). The reliability of the solder joint between electronic components and PWB is evaluated through the dynamic characteristic test, thermal shock test, and Taguchi method after the printing process. After experimenting with the dynamic characteristic test and thermal shock test with 20 boards, the solder paste was still able to provide a high-quality solder joint. In particular, the Taguchi method is used to determine the optimal control parameters and noise factors of the Solder Printer (SP) machine, that affects solder volume and solder height. The control parameters include table separation distance, squeegee speed, squeegee pressure, and table speed of the SP machine. The result shows that the most significant parameter for the solder volume is squeegee pressure (2.0 mm), and the solder height is the table speed of the SP machine (2.5 mm/s).
    Matched MeSH terms: Alloys
  3. Meor Yusoff, M.S., Masliana, M., Wilfred, P.
    MyJurnal
    Even though EDXRF analysis has major advantages in the analysis of stainless steel samples such as simultaneous determination of the minor elements, analysis can be done without sample preparation and non-destructive analysis, the matrix issue arised from the inter element interaction can make the the final quantitative result to be in accurate. The paper relates a comparative quantitative analysis using standard and standardless methods in the determination of these elements. Standard method was done by plotting regression calibration graphs of the interested elements using BCS certified stainless steel standards. Different calibration plots were developed based on the available certified standards and these stainless steel grades include low alloy steel, austentic, ferritic and high speed. The standardless method on the other hand uses a mathematical modelling with matrix effect correction derived from Lucas-Tooth and Price model. Further
    improvement on the accuracy of the standardless method was done by inclusion of pure elements into the development of the model. Discrepancy tests were then carried out for these quantitative methods on different certified samples and the results show that the high speed method is most reliable for determining of Ni and the standardless method for Mn.
    Matched MeSH terms: Alloys
  4. Sulong MZ, Setchell DJ
    J Prosthet Dent, 1991 Dec;66(6):743-7.
    PMID: 1805022
    Adhesive bond strength studies for the tray adhesive of an addition vinyl polysiloxane (President) impression material were conducted with an acrylic resin, chromium-plated brass, and plastic trays. Tensile and shear stress studies were performed on the Instron Universal testing machine. Acrylic resin specimens roughened with 80-grit silicon carbide paper exhibited appreciably higher bond strengths compared with different types of tray material and methods of surface preparation.
    Matched MeSH terms: Alloys/chemistry
  5. Rahbari, R., Hamdi, M., Farhudi, O., Yahya, R., Asmalina, M., Marzuki, Z.
    MyJurnal
    Self-propagating high-temperature synthesis (SHS) of powder compacts is a novel processing technique being developed as a route for the production of engineering ceramics and other advanced materials. The process, which is also referred to as combustion synthesis, provides energy- and cost-saving advantages over the more conventional processing routes for these materials. In the case of titanium or titanium alloy materials, prior researches employed powder metallurgy technology for preparing metal matrix composites, MMCs and laminated structures through the use of fine powders of an inert phase or phases (TiC, TiN, TiB and TiB2B ) dispersed in Ti or Ti alloy powders. The present research relates to manufacture of titanium-ceramic composites that are synthesized by combustion synthesis (SHS) and retains a multilayered composite microstructure comprising one or more titanium-based layers and one ceramic titanium carbide layers.
    Matched MeSH terms: Alloys
  6. Tuminoh H, Hermawan H, Ramlee MH
    J Mech Behav Biomed Mater, 2022 Nov;135:105457.
    PMID: 36116340 DOI: 10.1016/j.jmbbm.2022.105457
    In the last decade, magnesium alloys have been considered as absorbable metals for biomedical applications, while some have reached their clinical use as temporary bone implants. However, their widespread use is still limited by its strength and degradability. One way of improvement can be done by reinforcing magnesium alloys with carbon nanofibres to form composites. This work aims at developing carbon nanofibre-reinforced magnesium-zinc (Mg-Zn/CNF) composites with optimum strength and degradability while ensuring their biocompatibility. A response surface method was used to determine their optimum process parameters (composition, compaction pressure, and sintering temperature), and analyse the resulting properties (elastic modulus, hardness, weight loss, and cytocompatibility). Results showed that the optimal parameters were reached at 1.8% of CNF, 425 MPa of compaction pressure, and 500 °C of sintering temperature, whereby it gave an elastic modulus of 5 GPa, hardness of 60 Hv, and a weight loss of 51% after three days immersion in PBS. The composites exhibited a hydrophobic surface that controlled the liberation of Mg2+ and Zn2+ ions, leading to more than 70% osteoblast cells viability up to seven days of incubation. This study can also serve as a starting point for future researchers interested in finding methods to fabricate Mg-Zn/CNF composites with high mechanical characteristics, corrosion resistance, and biocompatibility.
    Matched MeSH terms: Alloys/chemistry
  7. Hassanin Abdulkhabeer Ali Alyassiri, Anis Farhan Kamaruddin, Khoirulzariah Ismail, Noor Ayuni Ahmad Shafiai, Norma Ab Rahman, Wan Muhamad Amir W Ahmad
    MyJurnal
    Introduction: Coated archwires improve aesthetics during orthodontic treatment. However, little is known regarding
    their clinical benefit. This randomised controlled trial (RCT) compared the tooth alignment (TA), coating loss (CL),
    colour change (∆E*), and patient perception of coated archwires with their controls. Details of ∆E* and perception were reported in the second part of the articles. Methods: This RCT was done at three centres. Participants
    were randomised to receive one of four treatment interventions using 0.014” superelastic coated nickel-titanium
    archwires from Orthocare, RMO, G&H, and conventional uncoated 3M Unitek® archwires. These archwires were
    ligated during bonding and collected after eighth week and questionnaires were distributed to participants in the
    experimental groups only. After removal, TA and CL were measured using Little’s Irregularity Index and Autodesk®
    AutoCAD® software, respectively. At the time of this preliminary reporting, 84 participants had completed the trial. Two archwires fractured and were excluded. Therefore, 166 archwires (n = 166) were analysed. Results: Only
    non-extraction cases showed statistically significant differences in TA change between all groups (p = 0.005) and
    RMO showed significantly lowest mean of TA (1.5 mm). RMO and Orthocare showed significant TA change in the
    upper and lower arches (p = 0.037, 0.048). CL was found to be insignificant for both extraction and non-extraction
    cases (p >0.05). Comparison between upper and lower arches revealed no significant difference in TA and CL in all
    groups (p >0.05). Conclusion: From this preliminary analysis, Orthocare provides better TA in non-extraction cases
    despite highest percentage of coating loss.
    Matched MeSH terms: Alloys
  8. Lin PC, Fang JC, Lin JW, Tran XV, Ching YC
    Materials (Basel), 2020 Sep 19;13(18).
    PMID: 32961763 DOI: 10.3390/ma13184170
    Effects of processing parameters on preheated (heat-assisted) clinching process to join aluminum alloy 5052-H32 (AA5052) and thermoplastic carbon-fiber-reinforced-plastic (TP-CFRP) sheets for cross-tension (CT) specimens were first studied. Preheating was critical since brittle TP-CFRP could be softened to avoid fracturing or cracking during clinching process. Four processing parameters, including punching force, die depth, heating mode, and heating temperature, were considered. Quasi-static tests and microscope observations were taken to evaluate AA5052/TP-CFRP clinch joints in CT specimens and determine appropriate processing parameters for fatigue tests. Finally, fatigue data and failure mode of clinch joints in CT specimens were obtained and discussed.
    Matched MeSH terms: Alloys
  9. Hassan MH
    Med J Malaysia, 2004 May;59 Suppl B:164-5.
    PMID: 15468869
    There has been, and is still, concern about the high elastic modulus of Ti alloys compared to bone. Any reduction in the Young's modulus value of the implant is expected to enhance stress redistribution to the adjacent bone tissues, minimize stress shielding and eventually prolong device lifetime. Dynamic Monte Carlo simulation is used to predict the gradual reduction in Young's modulus values between the bulk of Ti alloys and the modified surface layers due to Ca ion implantation. The simulation can be used as a screening step when applying new alloys and/or coatings.
    Matched MeSH terms: Alloys/analysis; Alloys/chemical synthesis*
  10. Sia U, Tan BB, Teo YY, Wong CC
    Malays Orthop J, 2019 Mar;13(1):14-19.
    PMID: 31001378 DOI: 10.5704/MOJ.1903.002
    Introduction: Post-implantation rod deformation is anticipated in scoliosis surgery but the difference in rod deformation between titanium and cobalt chrome rod has not been elucidated. This study aims to compare the difference in rod deformation between two groups. Materials and Methods: Twenty-one adolescent idiopathic scoliosis (AIS) patients were recruited from a single center. The over-contoured concave rods were traced prior to insertion. Post-operative sagittal rod shape was determined from lateral radiographs. Rod deformation was determined using maximal rod deflection and angle of the tangents to rod end points. The differences between pre- and post-operative rod contour were analysed statistically. Rod deformation and thoracic kyphosis between two types of implants were analysed. Results: Both rods exhibited significant change of rod angle and deflection post-operatively. Curvature of the titanium rod and cobalt chrome rod decreased from 60.5° to 37°, and 51° to 28° respectively. Deflection of titanium rod and cobalt chrome rod reduced from 28mm to 23.5mm and 30mm to 17mm respectively. There was no significant difference between titanium and cobalt chrome groups with regard to rod angle (p=0.173) and deflection (p=0.654). Thoracic kyphosis was increased from 20° to 26° in titanium group but a reduction from 25° to 23° was noticed in cobalt chrome group, but these findings were not statistically significant. Conclusion: There was no statistical difference in rod deformation between the two groups. Thus, the use of titanium rod in correction of sagittal profile is not inferior in outcome compared with cobalt chrome but with lower cost.
    Matched MeSH terms: Chromium Alloys
  11. Maqbool M, Tirmazi SSM, Shakoor A, Akram Z, Nazir R, Chohan AN, et al.
    Biomed Res Int, 2023;2023:1044541.
    PMID: 36845639 DOI: 10.1155/2023/1044541
    BACKGROUND: Despite of having improved endodontic file designs as well as the reinforced metal alloy file structure, intracanal endodontic file separation (EFS) is still a very problematic and worrisome dental incident, which usually occurs without any visible signs of permanent deformation. Further, there have been conflicting reports regarding the clinical significance of leaving separated files within root canals.

    AIMS: The aim of this study was to look into the current perceptions and awareness about file separation during endodontic treatment among the dental house officers (DHOs).

    MATERIALS AND METHODS: A novel validated questionnaire comprising of 15 close-ended questions was distributed anonymously via Google Forms through email to 1100 DHOs across Pakistan. The questionnaire consisted of two parts: the first component (Section I) collected demographic data and the second component (Section II) investigated the causes of EFS during root canal treatment. Following the completion of socioeconomic information, including age and gender, the DHOs were asked to answer a few questions about the various reasons for endodontic instrument fracture.

    RESULTS: A total of 800 responses were recorded, with an effective rate of 72.8%. The majority of the DHOs (p value < 0.001) perceived that endodontic instrument fracture occurred in the posterior (61.5%) and apical third of the canal (50.5%) and in older permanent dentition (67.3%), possibly due to patient anxiety (62%). Better choice of instrument (61.15%), operators' experience (95.3%), knowledge (87.5%), and proper root canal cleaning (91.1%) are believed to be the vital steps in reducing endodontic file separation/fracture. Furthermore, majority of them (p value < 0.001) perceived that stainless steel was a superior alloy for filing instruments. Manual files tend to be more prone to fractures due to repeated use than rotary files.

    CONCLUSION: This study demonstrated that young DHOs had adequate knowledge and awareness regarding the potential predisposing factors and handling techniques for EFS. This study thereby provides an evaluating tool to access the insights of the current perceptions and awareness of DHOs concerning EFS.

    Matched MeSH terms: Dental Alloys
  12. Mansor AF, Azmi AI, Zain MZM, Jamaluddin R
    Heliyon, 2020 Aug;6(8):e04812.
    PMID: 32913911 DOI: 10.1016/j.heliyon.2020.e04812
    Nickel-titanium shape memory alloy (NiTi) has a unique capacity to restore its initial shape after deformation, which is highly applicable to orthopaedic implantations, especially for the minimization of invasive surgeries. The high nickel content of this alloy can lead to unfavourable effects on the human body upon dissolution; thus, a reliable barrier of coatings on the NiTi surface is required to alleviate the nickel migration and increase its biocompatibility. In this paper, analyses of a titanium oxide layer development on NiTi surface using electrical discharge coating (EDC) process is presented. The recast layer thickness, crater sizes, and surface roughness were characterized based on five parameters; polarity, discharge duration, pulse interval, peak current, and gap voltage. The results show that the discharge duration is the most significant parameter to influence all responses, followed by peak current. The surface characteristics of the EDC substrate is depending on the crater formations and is highly correlated with the discharge energy intensity. As a result, appropriate parametric conditions of the electrical discharge coating process can enhance the NiTi surface for future medical applications, without compromising the shape memory effect.
    Matched MeSH terms: Alloys
  13. Ali RM, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar Hb, et al.
    EuroIntervention, 2011 May;7 Suppl K:K83-92.
    PMID: 22027736 DOI: 10.4244/EIJV7SKA15
    Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients.
    Matched MeSH terms: Chromium Alloys*
  14. Asma Alhusna Abang Abdullah, Nurul Asyikin Yahya
    Sains Malaysiana, 2011;40:1313-1317.
    Fixed orthodontic treatment requires the use of orthodontic brackets and archwires in order to correct malocclusions. The objective of this study was to evaluate the pattern of orthodontic material usages i.e. bracket and archwire among Malaysian orthodontists. A self-administered questionnaire was distributed to members of the Malaysian Association of Orthodontist. Data entry and statistical analysis was done using SPSS version 15.0. Descriptive statistics were used for analysis. Means and standard deviations were calculated for continuous variables, frequency and percentages for categorical variables. Thirty-four orthodontists responded to the survey, with 76% (n=26) were female and the mean age was 43.31 years (SD 8.76). Most respondents used conventional metal brackets (60%, n=60) and most bracket prescription used was MBT (56%, n=19). At levelling stage, most respondents used nickel titanium archwire (84.5%, n=47). Stainless steel archwire was the most favourable choice for retraction/space closure stage (73.9%, n=34). At finishing, most respondents (60.4%, n=29) preferred to use stainless steel wire in their cases. As a conclusion, specific types of orthodontic materials were preferred and used by Malaysian orthodontists in delivering orthodontic treatment.
    Matched MeSH terms: Alloys
  15. Mimala Arasaratnam, Zailina Hashim, Shamsul Bahari Shamsudin
    MyJurnal
    A cross-sectional study was conducted on 83 female electronics factory workers. The respondents comprised 50 exposed workers who use lead alloy solder and 33 unexposed workers. The objective of this study was to assess the lead exposure of these workers. Breathing zone were sampled using air sampling pumps. Dust samples were collected by wipe method. Venous blood collected and blood pressure were measured. All lead analyses were carried out with Graphite Furnace Atomic Absorption Spectrophotometer. The mean air lead for exposed workers (57 0. ± 0.93 μg/m³) was significantly higher than the unexposed workers (0.0067 ± 0.0045μg/m³) (p
    Matched MeSH terms: Alloys
  16. Mutafi A, Yidris N, Koloor SSR, Petrů M
    Materials (Basel), 2020 Nov 26;13(23).
    PMID: 33256257 DOI: 10.3390/ma13235378
    Stainless steels are increasingly used in construction today, especially in harsh environments, in which steel corrosion commonly occurs. Cold-formed stainless steel structures are currently increasing in popularity because of its efficiency in load-bearing capacity and its appealing architectural appearance. Cold-rolling and press-braking are the cold-working processes used in the forming of stainless steel sections. Press braking can produce large cross-sections from thin to thick-walled sections compared to cold-rolling. Cold-forming in press-braked sections significantly affect member behaviour and joints; therefore, they have attained great attention from many researchers to initiate investigations on those effects. This paper examines the behaviour of residual stress distribution of stainless steel press-braked sections by implementing three-dimensional finite element (3D-FE) technique. The study proposed a full finite element procedure to predict the residual stresses starting from coiling-uncoiling to press-braking. This work considered material anisotropy to examine its effect on the residual stress distribution. The technique adopted was compared with different finite element techniques in the literature. This study also provided a parametric study for three corner radius-to-thickness ratios looking at the through-thickness residual stress distribution of four stainless steels (i.e., ferritic, austenitic, duplex, lean duplex) in which have their own chemical composition. In conclusion, the comparison showed that the adopted technique provides a detailed prediction of residual stress distribution. The influence of geometrical aspects is more pronounced than the material properties. Neglecting the material anisotropy shows higher shifting in the neutral axis. The parametric study showed that all stainless steel types have the same stress through-thickness distribution. Moreover, R/t ratios' effect is insignificant in all transverse residual stress distributions, but a slight change to R/t ratios can affect the longitudinal residual stress distribution.
    Matched MeSH terms: Dental Alloys
  17. Ali B, Tasirin SM, Aminayi P, Yaakob Z, Ali NT, Noori W
    Nanomaterials (Basel), 2018 Dec 14;8(12).
    PMID: 30558256 DOI: 10.3390/nano8121053
    Porous Ni, Ni-Co, Ni-Fe, and Ni-Cu magnetic alloys with a morphology similar to a giant barrel sponge were synthesized via a facile co-precipitation procedure and then by hydrogen reduction treatment. For the first time, the non-supported alloys with their unique morphology were employed in catalytic biogas decomposition (CBD) at a reaction temperature of 700 °C and 100 mL min-1 to produce syngas and carbon bio-nanofilaments, and the catalysts' behavior, CH₄ and CO₂ conversion, and the carbon produced during the reaction were investigated. All of the equimolar alloy catalysts showed good activity and stability for the catalytic biogas decomposition. The highest sustainability factor (0.66) and carbon yield (424%) were accomplished with the Ni-Co alloy without any significant inactivation for six hours, while the highest carbon efficiency of 36.43 was obtained with the Ni-Co catalyst, which is considered relatively low in comparison with industry standards, indicating a low carbon production process efficiency, possibly due to the relatively high biogas flow rate. The higher activity of the Ni-Co alloy catalyst was associated with the synergistic impact between nickel and cobalt, allowing the catalyst to maintain a high stability throughout the reaction period. Moreover, highly uniform, interwoven carbon bio-nanofilaments with a parallel and fishbone structure were achieved.
    Matched MeSH terms: Alloys
  18. Roslinda Shamsudin, Abdul Razak Daud, Muhammad Azmi Abdul Hamid, Saiful Rizam Shamsudin
    Sains Malaysiana, 2007;36:195-200.
    Nitridation behaviour of Al-Mg-Si alloys was studied as a function of temperature by means of thermogravimetry method. A reactive gas, N2-4%H2 at a rate of 10 ml/min was purged into the thermogravimetry analyser chamber. The Al alloys were heated from 25oC to 625oC at the heating rate of 15oC/min and then reduced to 3oC/min until it reached 1500oC. It was found that by varying the amount of Mg and Si in Al-Mg-Si alloys significantly influenced the growth of the composites. A differential thermogravimetric curve shows the Mg containing alloys experienced many steps of chemical reactions. This indicates that besides AlN presence as a major phase, other compounds also exist in the final product. The X-ray diffraction results confirmed the existence of oxide phases such as a-Al2O3, MgAl2O4 and MgO in addition to residual Si and Al metal. The presence of oxide compounds is believed to be due to the reaction between the alloying elements and residual oxygen gas left in the reaction atmosphere. It was also found that Si could play a role in promoting the weight gain of the composite produced. The heating rate has also a profound effect on the weight gain, whereby higher heating rate resulted in low yielded of AlN during the nitridation reaction of the Al-Mg-Si alloys.
    Matched MeSH terms: Alloys
  19. Norman NH, Worthington H, Chadwick SM
    J Orthod, 2016 Sep;43(3):176-85.
    PMID: 26836747 DOI: 10.1080/14653125.2015.1122260
    OBJECTIVE: To compare the clinical performance of nickel titanium (NiTi) versus stainless steel (SS) springs during orthodontic space closure.
    DESIGN: Two-centre parallel group randomized clinical trial.
    SETTING: Orthodontic Department University of Manchester Dental Hospital and Orthodontic Department Countess of Chester Hospital, United Kingdom.
    SUBJECTS AND METHODS: Forty orthodontic patients requiring fixed appliance treatment were enrolled, each being randomly allocated into either NiTi (n = 19) or SS groups (n = 21). Study models were constructed at the start of the space closure phase (T0) and following the completion of space closure (T1). The rate of space closure achieved for each patient was calculated by taking an average measurement from the tip of the canine to the mesiobuccal groove on the first permanent molar of each quadrant.
    RESULTS: The study was terminated early due to time constraints. Only 30 patients completed, 15 in each study group. There was no statistically significant difference between the amounts of space closed (mean difference 0.17 mm (95%CI -0.99 to 1.34; P = 0.76)). The mean rate of space closure for NiTi coil springs was 0.58 mm/4 weeks (SD 0.24) and 0.85 mm/4 weeks (SD 0.36) for the stainless steel springs. There was a statistically significant difference between the two groups (P = 0.024), in favour of the stainless steel springs, when the mean values per patient were compared.
    CONCLUSIONS: Our study shows that stainless steel springs are clinically effective; these springs produce as much space closure as their more expensive rivals, the NiTi springs.
    Matched MeSH terms: Alloys; Dental Alloys
  20. Patil PG, Nimbalkar-Patil SP, Karandikar AB
    J Contemp Dent Pract, 2014 Jan 1;15(1):112-5.
    PMID: 24939276
    This case report demonstrates sequential periodontic, orthodontic and prosthodontic treatment modalities to save and restore deep horizontally fractured maxillary central incisor. The location of fracture was deep in the mucosa which reveals less than 2 mm of tooth structure to receive the crown. The procedures like surgical crown lengthening, endodontic post placement, orthodontic forced eruption, core build-up and metal-ceramic crown restoration were sequentially performed to conserve the fractured tooth. Forced eruption is preferred to surgical removal of supporting alveolar bone, since forced eruption preserves the biologic width, maintains esthetics, and at the same time exposes sound tooth structure for the placement of restorative margins.
    Matched MeSH terms: Metal Ceramic Alloys/chemistry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links