Stability indicating assay describes a technique which is used to analyse the stability of drug substance or active pharmaceutical ingredient (API) in bulk drug and pharmaceutical products. Stability indicating assay must be properly validated as per ICH guidelines. The important components in a stability indicating assay include sensitivity, specificity, accuracy, reliability, reproducibility and robustness. A validated assay is able to measure the concentration changes of drug substance/API with time and make reliable estimation of the quantity of the degradation impurities. The drug substance is separated and resolved from the impurities. Pros and cons of HPLC, GC, HPTLC, CE and SFC were discussed and reviewed. Stability indicating assay may consist of the combination of chromatographic separation and spectroscopic detection techniques. Hyphenated system could demonstrate parallel quantitative and qualitative analysis of drug substances and impurities. Examples are HPLC-DAD, HPLC-FL, GC-MS, LC-MS and LC-NMR. The analytes in the samples are separated in the chromatography while the impurities are chemically characterised by the spectroscopy in the system. In this review, various chromatographic methods which had been employed as stability indicating assays for drug substance and pharmaceutical formulation were systematically reviewed, and the application of hyphenated techniques in impurities characterisation and identification were also discussed with supporting literatures.
Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Liquid; Gas Chromatography-Mass Spectrometry
Ergosterol is the main component of the fungal membrane and is not found in plants or other microbial cells. Therefore, it can be a useful biomarker for the quantification of fungal biomass. We are now reporting the first isolation and characterisation of ergosterol from the mycelium of G. boninense. The ergosterol structure was detected by Thin Liquid Chromatography (TLC) and Ultra Performance Liquid Chromatography (UPLC) and confirmed with Gas Chromatography coupled with Mass Spectrometry (GCMS) and Nuclear Magnetic Resonance (NMR) analysis.
A study was carried out to compare the composition and thermal profiles of the fat component of six brands of commercial biscuits (BA, BB, BC, BD, BE & BF) with those of lard and palm oil. Extraction of fat from biscuit samples was done using petroleum ether according to the soxhlet extraction procedure. The isolated fat samples along with lard and palm oil were analyzed using gas liquid chromatography (GLC), reversed-phase high performance liquid chromatography (RP-HPLC), and differential scanning calorimetry (DSC). According to GLC analysis, palm oil, lard and all six biscuit brands had either palmitic or oleic acid as major fatty acids. Sn-2 positional analysis of fatty acids showed that oleic (> 60%) as the most dominant fatty acid of palm oil and biscuit brands BA, BB, BC, and BD while palmitic (> 60%) as the most dominant fatty acid of lard and biscuit brands BE and BF. RP-HPLC analysis showed that the triacylglycerol (TAG) profiles of lard and biscuit brands BE and BF were closely similar while those of brands BA, BB, BC, and BD and palm oil were similar. DSC analysis showed that the cooling and heating profiles of lard and brands BE and BF were similar, while those of palm oil and brands BA, BB, BC, and BD were similar. Hence, this study concluded that biscuit brands BE and BF are not suitable for consumers whose religious restriction prohibit the use of lard as food ingredient.
In this study, the unprecedented extraction of the Vitex pouch was performed. The compounds from
methanolic and chloroform extracts were isolated by using thin layer chromatography (TLC). The
compound of interest was investigated by using 1H-Nuclear Magnetic Resonance (NMR, 500 MHz)
spectroscopy. From the NMR spectral examination, the compound from the methanolic extract was
suggested as glucononitol. Indeed, there are some parameters that could enhance the attainment of this
research, which include high performance liquid chromatographic supplies. Nevertheless, more
information and understanding on the pharmaceutical and chemical analysis of the Vitex species were
obtained. To sum up, it is anticipated that incoming research with advanced technology for this
natural product could be explored in the future.
The seeds of C. cleomifolia (locally known as kacang hantu) collected along Simpang Pulai - Berinchang Road, Cameron Highlands, was defatted with hexane and the resulting oil was analysed for their physico-chemical properties. The percentage yield of the oil was calculated as 5.3%. The acid value (1.2%), iodine value (85), peroxide value (0.6), saponification value (192.0) and unsaponifiable matter (2.3%) were determined to assess the quality of the oil. The physico-chemical characterisation showed that C. cleomifolia seeds oil is unsaturated semi-drying oil, with high saponifi cation and acidic values. The fatty acid composition of C. cleomifolia seed oil was determined by Gas Chromatography and Gas Chromatography-Mass Spectrometry (ToF). The seed oil of C. cleomifolia contained linoleic acid (57.59%) and palmitic acid (5.07%), the most abundant unsaturated and saturated fatty acids, respectively. The polyunsaturated triacylglycerol (TAG) in C. cleomifolia seed oil determined by reverse phase High performance Liquid Chromatography; contained as PLL (18.04%) followed by POL + SLL (11.92%), OOL (7.04%) and PLLn (6.31%). The melting and cooling point of the oil were 16.22°C and -33.54°C, respectively
Matched MeSH terms: Chromatography, High Pressure Liquid; Gas Chromatography-Mass Spectrometry; Chromatography, Reverse-Phase
A paper-based polymeric ionic liquid (p-Poly-(MMA-IL)) was successfully developed by grafting the polymeric ionic liquid on the surface of commercial filter paper (FP) by using the dipping method, presenting a new cost-effective film. The newly developed p-Poly-(MMA-IL) FP was then applied as a paper-based thin-film microextraction (p-TFME) analytical device to extract 14 compounds as representative of five groups of antibiotic drugs, which were sulfonamides, tetracyclines, fluoroquinolones, penicillin and macrolides in environmental water samples. Besides, p-Poly-(MMA-IL) FP, p-Poly-(MMA) FP, and unmodified filter paper were successfully characterised by FTIR, NMR, FESEM, TGA, and XRD techniques. They underwent significant parameters optimisation, which affected the extraction efficiency. Under optimal conditions, the proposed (p-Poly-(MMA-IL) FP-TFME) device method was evaluated and applied to analyse multi-class antibiotic drugs in environmental water samples by using a liquid chromatography-mass spectrometry (LC-MS). The validation method showed that a good linearity (0.1 μg L-1 - 500 μg L-1) was noted (R2 > 0.993, n = 3). Detection and quantification limits were within 0.05 μg L-1 - 4.52 μg L-1 and 0.15 μg L-1 - 13.6 μg L-1, respectively. The relative standard deviation (RSD) values ranged at 1.4%-12.2% (intra-day, n = 15) and 4.4%-11.0% (inter-day, n = 10). The extraction recoveries of environmental water samples ranged from 79.1% to 126.8%, with an RSD of less than 15.4% (n = 3). The newly developed paper-based polymeric ionic liquid (p-Poly-(MMA-IL) FP) for analysis of multi-class antibiotic drugs under the p-TFME analytical device procedure was successfully achieved with limited sample volume and organic solvent, fast extraction, and feasible in daily analysis. The detection concentration and relative RSD of multi-class antibiotics determined in various environmental water samples by the proposed method (n = 5) were within 0.44 μg L-1 - 54.41 μg L-1 and 0.69%-15.56%, respectively. These results signified the potential of the p-Poly-(MMA-IL) FP-TFME device as an efficient, sensitive and environmentally friendly approach for analysing antibiotics.
Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Liquid/methods
The study aimed to develop a sensitive and high-throughput liquid chromatography coupled with tandem mass spectrometry method to quantify concentrations of tramadol and paracetamol simultaneously in human plasma. Sample preparation involved single-step protein precipitation using methanol and two deuterated internal standards, tramadol D6 and paracetamol D4. Agilent Poroshell 120 EC-C18 (100 × 2.1 mm, 2.1 µm) analytical column was employed to achieve chromatographic separation. Detection was in positive ion multiple reaction monitoring mode. A tailing factor (Tf) of <1.2, separation factor (K prime) of >1.5 from the column dead time and signal-to-noise (S/N) ratio >10, were obtained for analytes and internal standards. The standard curve was linear over the concentration range of 2.5-500.00 ng/mL for tramadol and 0.025-20.00 μg/mL for paracetamol. A small injection volume of 1 µL, low flow rate of 440 µL/min and short analysis time of 3.5 min reduced the solvent consumption, analysis cost and system contamination. The results of method validation parameters fulfilled the acceptance criteria of bioanalytical guidelines. The method was successfully applied to a bioequivalence study of fixed-dose combination products of tramadol and paracetamol in Malaysian healthy subjects.
Matched MeSH terms: Chromatography, High Pressure Liquid/methods; Chromatography, Liquid
Supercritical fluid extraction (SFE), which has received much interest in its use and further development for industrial applications, is a method that offers some advantages over conventional methods, especially for the palm oil industry. SC-CO₂ refers to supercritical fluid extraction (SFE) that uses carbon dioxide (CO₂) as a solvent which is a nontoxic, inexpensive, nonflammable, and nonpolluting supercritical fluid solvent for the extraction of natural products. Almost 100% oil can be extracted and it is regarded as safe, with organic solvent-free extracts having superior organoleptic profiles. The palm oil industry is one of the major industries in Malaysia that provides a major contribution to the national income. Malaysia is the second largest palm oil and palm kernel oil producer in the World. This paper reviews advances in applications of supercritical carbon dioxide (SC-CO₂) extraction of oils from natural sources, in particular palm oil, minor constituents in palm oil, producing fractionated, refined, bleached, and deodorized palm oil, palm kernel oil and purified fatty acid fractions commendable for downstream uses as in toiletries and confectionaries.
Linearity assessment as required in method validation has always been subject to different interpretations and definitions by various guidelines and protocols. However, there are very limited applicable implementation procedures that can be followed by a laboratory chemist in assessing linearity. Thus, this work proposes a simple method for linearity assessment in method validation by a regression analysis that covers experimental design, estimation of the parameters, outlier treatment, and evaluation of the assumptions according to the International Union of Pure and Applied Chemistry guidelines. The suitability of this procedure was demonstrated by its application to an in-house validation for the determination of plasticizers in plastic food packaging by GC.
The concentration of ochratoxin A (OTA) in 120 commercial pepper (84 pre-packed and 36 bulk samples), which consist of local and imported white and black pepper in powder and seed form in Malaysia were determined. The objective of the study was to investigate and compare OTA concentration in black pepper and white pepper being commercialized in Malaysia. Determination method was based on HPLC with fluorescence detection coupled with immunoaffinity column clean-up step. Mobile phase consisted of acetonitrile-water-acetic acid (49.5:49.5:1.0, v/v/v), and flow rate was 1 ml/min. The LOD was 0.02 ng/g, and the average recovery values of OTA ranged from 79.5 to 92.0% in black pepper and 81.2-90.3% in white pepper. A total of 57 samples (47.5%) were contaminated with OTA ranging from 0.15 to 13.58 ng/g. The results showed that there was a significant difference between type of pepper and brands. OTA concentration in black pepper was significantly higher than white pepper (p < 0.05). The highest concentration of ochratoxin, 13.58 ng/g, was detected in a sample of black pepper seed followed by 12.64 ng/g in a sample of black pepper powder, both were bulk samples purchased from open market.
Matched MeSH terms: Chromatography, Affinity; Chromatography, High Pressure Liquid
Plant cell culture technology is potentially useful in producing high-valued secondary metabolites. Eurycoma longifolia root extracts are consumed as a health tonic but more popularly used as an aphrodisiac. Studies on the aphrodisiac properties and the possible compounds involved have been widely studied. There are many potentially useful compounds reported from the root extracts of E. longifolia. However, studies on the in vitro production of useful compounds from this plant have not been reported. This chapter will describe methods of callus induction and extraction of 9-methoxycanthin-6-one from E. longifolia Jack explants with emphasis on the tap and fibrous roots. This compound, known to have anti-tumour activity, is present in intact plant parts and in callus tissues of different explants.
Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Thin Layer
The sample preparation step has been identified as the bottleneck of analytical methodology in chemical analysis. Therefore, there is need for the development of cost-effective, easy to operate, and environmentally friendly miniaturized sample preparation technique. The microextraction techniques combine extraction, isolation, concentration, and introduction of analytes into analytical instrument, to a single and uninterrupted step, and improve sample throughput. The use of liquid-phase microextraction techniques for the analysis of pesticide residues in fruits and vegetables are discussed with the focus on the methodologies employed by different researchers and their analytical performances. Analytes are extracted using water-immiscible solvents and are desorbed into gas chromatography, liquid chromatography, or capillary electrophoresis for identification and quantitation.
Palm oil is the richest source of natural carotenes, comprising 500-700 ppm in crude palm oil (CPO). Its concentration is found to be much higher in oil extracted from palm-pressed fiber, a by-product from the milling of oil palm fruits. There are 11 types of carotenes in palm oil, excluding the cis/trans isomers of some of the carotenes. Qualitative separation of these individual carotenes is particularly useful for the identification and confirmation of different types of oil as the carotenes profile is unique to each type of vegetable oil. Previous studies on HPLC separation of the individual palm carotenes reported a total analyses time of up to 100 min using C30 stationary phase. In this study, the separation was completed in <5 min. The qualitative separation was successfully carried out using a commonly used stationary phase, C18.
In this study, the methods for extraction and purification of miraculin from Synsepalum dulcificum were investigated. For extraction, the effect of different extraction buffers (phosphate buffer saline, Tris-HCl and NaCl) on the extraction efficiency of total protein was evaluated. Immobilized metal ion affinity chromatography (IMAC) with nickel-NTA was used for the purification of the extracted protein, where the influence of binding buffer pH, crude extract pH and imidazole concentration in elution buffer upon the purification performance was explored. The total amount of protein extracted from miracle fruit was found to be 4 times higher using 0.5M NaCl as compared to Tris-HCl and phosphate buffer saline. On the other hand, the use of Tris-HCl as binding buffer gave higher purification performance than sodium phosphate and citrate-phosphate buffers in IMAC system. The optimum purification condition of miraculin using IMAC was achieved with crude extract at pH 7, Tris-HCl binding buffer at pH 7 and the use of 300 mM imidazole as elution buffer, which gave the overall yield of 80.3% and purity of 97.5%. IMAC with nickel-NTA was successfully used as a single step process for the purification of miraculin from crude extract of S. dulcificum.
Vitamin E was determined by the high-performance liquid chromatography (HPLC) method. All the plants tested showed differences in their alpha-tocopherol content and the differences were significant (p < 0.05). The highest alpha-tocopherol content was in Sauropus androgynus leaves (426.8 mg/kg edible portion), followed by Citrus hystrix leaves (398.3 mg/kg), Calamus scipronum (193.8 mg/kg), starfruit leaves Averrhoa belimbi (168.3 mg/kg), red pepper Capsicum annum (155.4 mg/kg), local celery Apium graveolens (136.4 mg/kg), sweet potato shoots Ipomoea batatas (130.1 mg/kg), Pandanus odorus (131.5 mg/kg), Oenanthe javanica (146.8 mg/kg), black tea Camelia chinensis (183.3 mg/kg),papaya Carica papaya shoots (111.3 mg/kg), wolfberry leaves Lycium chinense (94.4 mg/kg), bird chili Capsicum frutescens leaves (95.4 mg/kg), drumstick Moringa oleifera leaves (90.0 mg/kg), green chili Capsicum annum (87 mg/kg), Allium fistulosum leaves (74.6 mg/kg), and bell pepper Capsicum annum (71.0 mg/kg). alpha-Tocopherol was not detected in Brassica oleracea, Phaeomeria speciosa, Pachyrrhizus speciosa, Pleurotus sajor-caju, and Solanum melongena.
Matched MeSH terms: Chromatography, High Pressure Liquid/methods
A simple high-performance liquid chromatographic method was developed for the determination of omeprazole in human plasma. Omeprazole and the internal standard, chloramphenicol, were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M Na2HPO4-ACN (65:35, v/v) adjusted to pH 6.5. Analysis was run at a flow rate of 1.0 ml/min at a detection wavelength of 302 nm. The method was specific and sensitive with a detection limit of 2.5 ng/ml at a signal-to-noise ratio of 4:1. The limit of quantification was set at 5 ng/ml. The calibration curve was linear over a concentration range of 5-1280 ng/ml. Mean recovery value of the extraction procedure was about 96%, while the within and between day coefficient of variation and percent error values of the assay method were all less than 14%.
Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
There are many methods to separate or purify the rebaudioside A compound from Stevia rebaudiana extract. However, the ion-exchange chromatography using macroporous resin is still the most popular among those methods. The separation of rebaudioside A from stevia crude extract by macroporous resin AB-8 was optimised in this adsorption separation study. This approach was applied to evaluate the influence of four factors such as the adsorption temperature, desorption time, elution solution ratio, and adsorption volume on rebaudioside A yield of the purified stevia extract. The results showed that the low polarity resin AB-8 is able to separate rebaudioside A from stevia extract with 0.601 in yield compared to the high polarity resin HPD 600 with 0.204 in yield used in Anvari and Khayati study. The best conditions for rebaudioside A separation by macroporous resin AB-8 were at 35°C of adsorption temperature, 30 min of desorption time, elution solution ratio 2:1, and 50 mL of adsorption volume.
Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Ion Exchange
Mycotoxin toxicity occurs at very low concentrations, therefore sensitive and reliable methods for their detection are required. Consequently, sampling and analysis of mycotoxins is of critical importance because failure to achieve a suitable verified analysis can lead to unacceptable consignments being accepted or satisfactory shipments unnecessarily rejected. The general mycotoxin analyses carried out in laboratories are still based on physicochemical methods, which are continually improved. Further research in mycotoxin analysis has been established in such techniques as screening methods with TLC, GC, HPLC, and LC-MS. In some areas of mycotoxin method development, immunoaffinity columns and multifunctional columns are good choices as cleanup methods. They are appropriate to displace conventional liquid-liquid partitioning or column chromatography cleanup. On the other hand, the need for rapid yes/no decisions for exported or imported products has led to a number of new screening methods, mainly, rapid and easy-to-use test kits based on immuno-analytical principles. In view of the fact that analytical methods for detecting mycotoxins have become more prevalent, sensitive, and specific, surveillance of foods for mycotoxin contamination has become more commonplace. Reliability of methods and well-defined performance characteristics are essential for method validation. This article covers some of the latest activities and progress in qualitative and quantitative mycotoxin analysis.
Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Liquid