Displaying publications 41 - 60 of 105 in total

Abstract:
Sort:
  1. Obaid, Kadhim Jawad, Sood, Suneet
    Medical Health Reviews, 2009;2009(1):59-73.
    MyJurnal
    Robotic surgery is a technique that uses mechanical, computercontrolled arms to conduct surgical operations. It carries the advantages of minimal access associated with laparoscopic surgery, and of precision associated with open surgery. It is also feasible to conduct robotic surgery with the surgeon far away, by “telerobotics”. The robot is more versatile than the human arm, and less susceptible to tremors. The view is excellent, and it is possible to conduct more intricate procedures than are possible with the human hand. Robotics has been in use for over seven years, and the initial experience shows that the success rate is over 90%, with only about 10% of cases needing to be converted to open surgery. Blood loss is low, and tumour margins in cancer surgery are satisfactory. Surgeons have used robotics for procedures in urology, gastrointestinal surgery, gynecology, cardiac surgery, neurosurgery, orthopedics, and other specialties. Presently, robotics suffers from two major disadvantages: one, that it is very expensive, and two, that robotic procedures take significantly longer than do open or laparoscopic procedures.
    Matched MeSH terms: Orthopedics
  2. Nur Azida Che Lah, Muhamad Hellmy Hussin
    MyJurnal
    Titanium (Ti) and Ti-based alloys presence the most widely applied as advanced biomaterials
    in biomedical implant applications. Moreover, these alloys are known to be the most
    valuable metallic materials including spinal cord surgical treatment. It becomes an interest
    due to its advantages compared to others, including its bio compatibility and corrosion
    resistant. However, an issue arises when it comes for permanent implant application as
    the alloy has a possible toxic effect produced from chemical reaction between body fluid
    environments with alloys chemical compositions. It also relies on the performance of
    neighbouring bone tissue to integrate with the implant surface. Abnormalities usually
    happen when surrounding tissue shows poor responses and rejection of implants that would
    leads to body inflammation. These cause an increase in foreign body reaction leading to
    severe body tissue response and thus, loosening of the implant. Corrosion effects and
    biocompatibility behaviour of implantation usage also become one of the reasons of
    implant damage. Here, this paper reviews the importance of using Ti and Ti-based alloys
    in biomedical implantation, especially in orthopaedic spinal cord injury. It also reviews the
    basic aspects of corrosion effects that lead to implant mechanical damage, poor response
    of body rejection and biocompatibility behaviour of implantation usage.
    Matched MeSH terms: Orthopedics
  3. Noordin MY, Jiawkok N, Ndaruhadi PY, Kurniawan D
    Proc Inst Mech Eng H, 2015 Nov;229(11):761-8.
    PMID: 26399875 DOI: 10.1177/0954411915606169
    There are millions of orthopedic surgeries and dental implantation procedures performed every year globally. Most of them involve machining of bones and cartilage. However, theoretical and analytical study on bone machining is lagging behind its practice and implementation. This study views bone machining as a machining process with bovine bone as the workpiece material. Turning process which makes the basis of the actually used drilling process was experimented. The focus is on evaluating the effects of three machining parameters, that is, cutting speed, feed, and depth of cut, to machining responses, that is, cutting forces and surface roughness resulted by the turning process. Response surface methodology was used to quantify the relation between the machining parameters and the machining responses. The turning process was done at various cutting speeds (29-156 m/min), depths of cut (0.03 -0.37 mm), and feeds (0.023-0.11 mm/rev). Empirical models of the resulted cutting force and surface roughness as the functions of cutting speed, depth of cut, and feed were developed. Observation using the developed empirical models found that within the range of machining parameters evaluated, the most influential machining parameter to the cutting force is depth of cut, followed by feed and cutting speed. The lowest cutting force was obtained at the lowest cutting speed, lowest depth of cut, and highest feed setting. For surface roughness, feed is the most significant machining condition, followed by cutting speed, and with depth of cut showed no effect. The finest surface finish was obtained at the lowest cutting speed and feed setting.
    Matched MeSH terms: Orthopedics/methods*
  4. Nazri Mohd Yusof
    MyJurnal
    Gastrocnemius flap is the workhorse for wound coverage in the proximal
    tibia. It can be perform by general orthopaedic surgeon because it is done without the
    need of microscopic instrumentation. Its coverage can be extended to cover the knee
    and midshaft of tibia when skin overlying it is included in the flap. (Copied from article).
    Matched MeSH terms: Orthopedics
  5. Nadia, M.N., Samsul Johari, M.A., Muhammad, M., Raha, A.R., Nurlia, Y.
    MyJurnal
    This study aimed to compare dexmedetomidine and propofol, in terms of haemodynamic parameters, respiratory rates and offset times, when used for sedation in patients undergoing elective orthopaedic and surgical procedures under regional anaesthesia. This was a prospective, randomised, single-blind study where 88 patients were recruited. Patients were randomised into two groups to receive either dexmedetomidine or propofol infusion. Central neuraxial blockade (spinal, epidural or combined spinal epidural) was performed. After ensuring an adequate block and stable haemodynamic parameters, dexmedetomidine was infused 15 minutes later at 0.4 μg/kg/hr, and propofol, at a target concentration of 2.5 μg/ml. Both drugs were titrated to achieve a bispectral index score of 70 before surgery commenced. Sedation level was monitored using the bispectral index score and assessed by the Observer Assessment of Alertness Scale score. Drug infusion was adjusted to maintain bispectral index scores ranging between 70-80 during surgery. Both groups showed reductions in mean arterial pressure and heart rate from baseline readings throughout the infusion time. However there was no significant reduction in the first 15 minutes from baseline (p > 0.05). Haemodynamic parameters and respiratory rate between both groups were not significantly different (p > 0.05). No patient demonstrated significant respiratory depression or SpO2 ≤ 95%. Offset times were also not significantly different between both groups (p = 0.594). There were no significant differences in haemodynamic parameters, respiratory rates and offset times between dexmedetomidine and propofol used for sedation in patients undergoing elective orthopaedic and surgical procedures under regional anaesthesia.
    Matched MeSH terms: Orthopedics
  6. Muzaffar TST, Imran Y, Iskandar MA, Zakaria A
    Med J Malaysia, 2005 Jul;60 Suppl C:26-9.
    PMID: 16381279
    Femoral interlocking nailing requires fluoroscopic assistance for insertion of the nail and distal screws. In this study, scattered radiation to the eye and hand of the operating surgeon was measured during the procedure. Thermo-luminescent dosimeter (TLD) was used to quantify the dose received by the surgeon. The mean radiation exposure time during the procedure was 3.89 minutes. The mean scattered radiation doses to the hand and eye were 0.27 mSv and 0.09 mSv per procedure respectively. These very low doses have made a surgeon very unlikely to receive more than the recommended annual dose limit set by the National Council on Radiological Protection.
    Matched MeSH terms: Orthopedics*
  7. Muhammad Hanif Ramlee
    MyJurnal
    Most orthopaedic cases that involved with bone fracture are normally treated with medical implants. To be noticed that some precautions in terms of biomechanical and biomaterial properties are necessary for a successful post-sur- gery process. The biomechanical evaluation of implants could be carried out using computing and engineering technologies. However, in the computer simulation, some assumptions are needed as the limitations on computer resources and data input. This review focuses on the current method of developing the finite element model for patients with specific values of material properties for lower limb part such as hip, knee and ankle joint. Previous literature was reviewed from which keywords and search engines were identified. In this review, inclusion and exclusion criteria were used to limit the literature search. We reviewed the state-of-the-art in this area and provide recommendations for future research. In conclusion, the previous published reports illustrated different methods to develop numerical models.
    Matched MeSH terms: Orthopedics
  8. Mohd S, Yusof N, Ramalingam S, Ng WM, Mansor A
    Malays Orthop J, 2017 Jul;11(2):1-6.
    PMID: 29021871 MyJurnal DOI: 10.5704/MOJ.1707.004
    Despite increasing use of bone graft in Malaysia, there was still lack of data to quantify knowledge level on bone banking among orthopaedic community who are involved in transplantation related work. Therefore, a survey on awareness in tissue banking specifically bone banking, usage and choice of bone grafts was conducted. From 80 respondents, 82.5% were aware about tissue banking however only 12.5% knew of the existence of tissue banks in Malaysia. Femoral head was the bone allograft most often used as a substitute to autograft. Only 34.8% respondents preferred irradiated bone grafts whilst 46.9% preferred nonirradiated, indicating the need to educate the importance of radiation for sterilising tissues. Exhibition was the most preferred medium for awareness programme to disseminate information about bone banking in the orthopaedic community. The professional awareness is necessary to increase the knowledge on the use of bone graft, hence to increase bone transplantation for musculoskeletal surgeries in the country.
    Matched MeSH terms: Orthopedics
  9. Mohd Miswan MF, Latiff Alsagoff S, Muhamad Effendi F, Ibrahim MI
    Malays Fam Physician, 2019;14(2):26-28.
    PMID: 31827732
    Locked knee is an orthopaedic condition requiring urgent treatment. Although the condition can be diagnosed via history, physical examination and imaging studies, the cause of the mechanical obstruction may only be apparent during arthroscopic examination of the knee joint. It is known that imaging plays a role in evaluating the integrity of intra-articular structures, however in some atypical cases, imaging cannot identify the definitive cause of locked knee. Here we report on two cases of locked knee, due to uncommon conditions which were unobservable via normal imaging studies.
    Matched MeSH terms: Orthopedics
  10. Mohammad Arif Shahar, Mohd Faiz Idris, Che Anuar Che Mohamad, Zul Azlin Razali
    MyJurnal
    The Kulliyyah of Medicine of IIUM has pioneered the Islamization of Medicine in Malaysia since its establishment in year 1994. Therefore, it is timely to review publications on Islamization by the kulliyyah and also to propose a classification system in the field of researches to promote an organized, comprehensive, inclusive and relevant Islamization process. The aim is to review and classify publications on Islamization performed by the members of Kulliyyah of Medicine, International Islamic University Malaysia (IIUM). All researches and publications deposited in the IIUM Repository (IREP) under the Kulliyyah of Medicine between 1st of January 2000 and 31st of August 2016 were reviewed. Journal articles, posters and proceedings with Islamization themes were identified. These publications were classified based on common themes to either of the following; 1) "Islamic Principles and Related Rulings in Medicine"; 2) "Medical Treatment for Muslim Patients"; 3) "Islamic Input in Medical Practices"; 4) "Ruqyah and Tibb an-Nabawi in Contemporary Medicine". A total of 1616 items (journal articles, abstracts and proceedings) were reviewed. Sixty-one (3.8%) of them were related to Islamization. The major contributors to writings in Islamization are the Orthopaedics, Traumatology and Rehabilitation Department (10%) followed by the Internal Medicine Department (7.9%), from their total deposits in the IREP database. Majority (36.5%) of work were done in "Islamic Principles and Related Rulings in Medicine", which dwells in subjects such as euthanasia, autonomy and doctor-patient relationship followed by "Islamic Input in Medical Practice" (28.6%) which was related to topics in the medical curriculum such as Fiqh Ibadah for the sick. Twenty-three point eight percent (23.8%) of work were in the "Medical Treatment for Muslim Patients" which focuses on Ramadan and diabetes and joint problems and Solat. Minimal work (7.9%) was done in the "Ruqyah and Tibb an-Nabawi in Contemporary Medicine" category. Low number of publications on Islamization was deposited in the IREP database for the past 15 years. Based on the proposed classification system, majority of publications were on "Islamic Principles and Related Rulings in Medicine" and "Islamic Input in Medical Practice". More work is required on the theme of "Medical Treatment for Muslim Patients" and "Ruqyah and Tibb an-Nabawi in Contemporary Medicine".
    Matched MeSH terms: Orthopedics
  11. Mohamed-Haflah NH, Abdullah S, Abdul-Rani R
    Malays Orthop J, 2021 Mar;15(1):16-20.
    PMID: 33880143 DOI: 10.5704/MOJ.2103.003
    The Coronavirus (COVID-19) pandemic and institution of the Movement Control Order (MCO) had resulted in the cancellation of a major orthopaedic exam in April 2020. The exam is known as the Malaysian Orthopaedic Specialist Committee (OSC) Part I Examinations. It is similar to the British Royal Colleges of Surgeons Membership (MRCS) exams and held twice annually in April and October. There are up to 200 candidates involved. With implementation of new guidelines and standard operating procedures (SOP), the OSC Part I exam was successfully held by Universiti Kebangsaan Malaysia (UKM) from 5th-9th October 2020. Here we highlight the challenges we faced whilst coordinating a major exam at a national level during the COVID-19 pandemic with recommendations for future exams.
    Matched MeSH terms: Orthopedics
  12. May Honey Ohn
    MyJurnal
    This systematic review was aimed to evaluate the effectiveness of technology-enhanced learning (TEL) used in medical teaching for undergraduate medical students. The objectives are to (a) identify various teaching modalities which are used to enhance TEL; (b) evaluate whether TEL is more effective than traditional learning (TL) in cognitive and affective learning domain outcome. The empirical studies were searched in the following databases: Google Scholar, MEDLINE, ERIC, ProQuest, Cochrane Library and Scopus. All papers published from 2008 to 2018 were included. From eligible studies, the study design, study field, study population, intervention methods, type of assessment and learning achievement were abstracted and summarized the information. The search results were independently reviewed by two authors. From a pool of 1384 articles, 43 eligible articles were identified, enrolling 7292 undergraduate medical students examining comparative study between TEL and traditional learning. The results showed that there was a high degree of heterogeneity seen amongst the included studies in terms of TEL modalities used. The majority of intervention studies favoured online resources, while the rest used various offline multimedia electronic devices, virtual simulations and blended modes. Overall findings showed promising data that TEL is better than TL with regards to knowledge gain and skill acquisition, as well as providing higher student satisfaction. In all, the findings present blended learning in a positive and promising light in time, particularly where systematic reviews on technology-enhanced learning in the field of the undergraduate medical programme have produced mixed result.REVIEW ARTICLEA Systematic Literature Review on Technology-Enhanced Learning in Medical EducationMay Honey Ohn1*, Bareth Ravindran2, Chan Zhi Wei3, Khin Maung Ohn4, Ng Pey Luen5Borneo Journal of Medical Sciences 14 (1) January, 2020: 3 – 171 Emergency Department, Sandwell & West Birmingham NHS Trust, United Kingdom2 Surgical Department, Hospital Tuanku Ja’afar Seremban, Kuala Lumpur, Malaysia3 Orthopaedics Department, Hospital Sungai Buloh, Kuala Lumpur, Malaysia4 Department of Surgery, Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia5 Radiology Department, Hospital Queen Elizabeth II, Sabah, Malaysia* Corresponding author’s email: mayhoney.ohn@gmail.com Received: 14 July 2019 Accepted: 5 November 2019Borneo Journal of Medical SciencesBJMSKeywords: blended learning, technology-enhanced learning, medical education, hybrid learning, undergraduate medical students
    Matched MeSH terms: Orthopedics
  13. Mansor AF, Azmi AI, Zain MZM, Jamaluddin R
    Heliyon, 2020 Aug;6(8):e04812.
    PMID: 32913911 DOI: 10.1016/j.heliyon.2020.e04812
    Nickel-titanium shape memory alloy (NiTi) has a unique capacity to restore its initial shape after deformation, which is highly applicable to orthopaedic implantations, especially for the minimization of invasive surgeries. The high nickel content of this alloy can lead to unfavourable effects on the human body upon dissolution; thus, a reliable barrier of coatings on the NiTi surface is required to alleviate the nickel migration and increase its biocompatibility. In this paper, analyses of a titanium oxide layer development on NiTi surface using electrical discharge coating (EDC) process is presented. The recast layer thickness, crater sizes, and surface roughness were characterized based on five parameters; polarity, discharge duration, pulse interval, peak current, and gap voltage. The results show that the discharge duration is the most significant parameter to influence all responses, followed by peak current. The surface characteristics of the EDC substrate is depending on the crater formations and is highly correlated with the discharge energy intensity. As a result, appropriate parametric conditions of the electrical discharge coating process can enhance the NiTi surface for future medical applications, without compromising the shape memory effect.
    Matched MeSH terms: Orthopedics
  14. Loh YC, Lam WL, Stanley JK, Soames RW
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):83-6.
    PMID: 15237127 DOI: 10.1177/230949900401200115
    Radial tunnel syndrome refers to pain on the lateral aspect of the forearm as a result of compression of the posterior interosseous nerve within a tunnel with specific anatomical boundaries. Diagnosis of the condition is difficult because of its close association with lateral epicondylitis, which warrants different methods of treatment. Based on a cadaveric study, a new clinical test, the Rule-of-Nine test, is proposed to improve the diagnostic accuracy in radial tunnel syndrome. The test involves constructing 9 equal squares on the anterior aspect of the forearm and noting those squares where tenderness can be elicited.
    Matched MeSH terms: Orthopedics/methods*
  15. Ling JL, Teo SH, Mohamed Al-Fayyadh MZ, Mohamed Ali MR, Ng WM
    Arthroscopy, 2019 02;35(2):596-604.
    PMID: 30611592 DOI: 10.1016/j.arthro.2018.08.038
    PURPOSE: To assess the effectiveness of a low-cost self-made arthroscopic camera (LAC) in basic arthroscopic skills training compared with a commercial arthroscopic camera (CAC).

    METHODS: One hundred fifty-three orthopaedic residents were recruited and randomly assigned to either the LAC or CAC. They were allocated 2 practice sessions, with 20 minutes each, to practice 4 given arthroscopic tasks: task 1, transferring objects; task 2, stacking objects; task 3, probing numbers; and task 4, stretching rubber bands. The time taken for participants to complete the given tasks was recorded in 3 separate tests; before practice, immediately after practice, and after a period of 3 months. A comparison of the time taken between both groups to complete the given tasks in each test was measured as the primary outcome.

    RESULTS: Significant improvements in time completion were seen in the post-practice test for both groups in all given arthroscopic tasks, each with P < .001. However, there was no significant difference between the groups for task 1 (P = .743), task 2 (P = .940), task 3 (P = .932), task 4 (P = .929), and total (P = .944). The outcomes of the tests (before practice, after practice, and at 3 months) according to repeated measures analysis of variance did not differ significantly between the groups in task 1 (P = .475), task 2 (P = .558), task 3 (P = .850), task 4 (P = .965), and total (P = .865).

    CONCLUSIONS: The LAC is equally as effective as the CAC in basic arthroscopic skills training with the advantage of being cost-effective.

    CLINICAL RELEVANCE: In view of the scarcity in commercial arthroscopic devices for trainees, this low-cost device, which trainees can personally own and use, may provide a less expensive and easily available way for trainees to improve their arthroscopic skills. This might also cultivate more interest in arthroscopic surgery among junior surgeons.

    Matched MeSH terms: Orthopedics
  16. Lim, W.K., Ling, H.T., R. Ramanathan
    MyJurnal
    Brush cutting is a commonly performed activity occupationally as well as recreationally in Malaysia. There are various occupational injuries reported related to brush cutting, for example foreign body penetration. There were 11 reported cases of foreign body penetrated in leg of brush cutting workers admitted to orthopaedic ward in Hospital Raja Permaisuri Bainun from the period of January till October 2009. Among the cases, 4 were surgically removed under local anaesthesia and 7 cases performed under general anesthesia. 2 cases reported foreign body penetrated into tibia bone. There were many contributing factors to the injury, which include lack of protective measures for workers, engineering property of brush cutting machine and education on handling of equipment. It is vital to study the factors separately in order to determine and recommend useful preventive measures. However, the actual numbers of cases are under reported and awareness of the problem is undermined.
    Matched MeSH terms: Orthopedics
  17. Lee, K.H., Ng, A.B.Y., Tan, T.B., Mossinac, K., To, B.C. Se
    Malays Orthop J, 2008;2(2):11-15.
    MyJurnal
    Gentamicin, whether administered either intravenously, incorporated into bone cement or for local intra-operative irrigation, is a commonly used antibiotic in orthopaedic practice. The former two have been well studied, however the literature on the therapeutic efficacy and safety of gentamicin irrigation is sparse. The objective of this study was to assess systemic absorption of gentamicin irrigation in joint replacement surgery. This was a non-randomised, prospective study. Ninety-eight patients (group A) who underwent total joint replacement and 40 patients (group B) who underwent hemi-arthroplasty were treated traoperatively with gentamicin irrigation. Serum gentamicin levels were assayed at 4 hours and 24 hours post-surgery. Sixteen of 98 patients in group A (16%) and 12 out of 40 patients in group B (30%) were found to have serum gentamicin level above 2mcg/ml at 4 hours post-surgery. We conclude that intra-articular gentamicin irrigation is systemically absorbed at substantial levels.
    Matched MeSH terms: Orthopedics
  18. Lee, C.K., Kwan, M.K., Chua, Y.P.
    Malays Orthop J, 2009;3(1):85-87.
    MyJurnal
    Removal of plates is a procedure commonly performed by orthopaedic surgeons and stripped screws are probably the most common problem encountered during this procedure. Stripped screws are caused by slippage between the screwdriver and the screw. Due to the inherent difficulty in removing such screws, surgeons should be knowledgeable in techniques for their removal and should be equipped with the proper instruments to expedite the procedure. There are few published articles about such techniques. This report describes a technique for removal of plates with stripped screws. The tip of a stripped screw is approached from the far cortex and then reamed with a trephine reamer in the direction of the screw until both cortices are cleared. The plate is then removed with stripped screws attached. All the removals utilizing this technique to date have been successful with no complications, and this method is safe, efficient and technically easy to learn.


    Matched MeSH terms: Orthopedics
  19. Lee JK, Mitchell PJ, Ang SB, Mercado-Asis LB, Rey-Matias R, Li J, et al.
    Arch Osteoporos, 2024 Apr 02;19(1):24.
    PMID: 38565791 DOI: 10.1007/s11657-024-01375-6
    A survey of awareness and attitudes to the management of fragility fractures among the membership of the Asia Pacific Orthopaedic Association conducted in 2022 found considerable variation in care across the region. A Call to Action is proposed to improve acute care, rehabilitation and secondary fracture prevention across Asia Pacific.

    PURPOSE: Fragility fractures impose a substantial burden on older people and their families, healthcare systems and national economies. The current incidence of hip and other fragility fractures across the Asia Pacific region is enormous and set to escalate rapidly in the coming decades. This publication describes findings of a survey of awareness and attitudes to the management of fragility fractures among the membership of the Asia Pacific Orthopaedic Association (APOA) conducted in 2022.

    METHODS: The survey was developed as a collaboration between the Asia Pacific Osteoporosis and Fragility Fracture Society and the Asia Pacific Fragility Fracture Alliance, and included questions relating to aspects of care upon presentation, during surgery and mobilisation, secondary fracture prevention, and access to specific services.

    RESULTS: In total, 521 APOA members completed the survey and marked variation in delivery of care was evident. Notable findings included: Fifty-nine percent of respondents indicated that analgesia was routinely initiated in transit (by paramedics) or within 30 minutes of arrival in the Emergency Department. One-quarter of respondents stated that more than 80% of their patients underwent surgery within 48 hours of admission. One-third of respondents considered non-hip, non-vertebral fractures to merit assessment of future fracture risk. One-third of respondents reported the presence of an Orthogeriatric Service in their hospital, and less than a quarter reported the presence of a Fracture Liaison Service.

    CONCLUSION: A Call to Action for all National Orthopaedic Associations affiliated with APOA is proposed to improve the care of fragility fracture patients across the region.

    Matched MeSH terms: Orthopedics*
  20. Lau CF, Malek S, Gunalan R, Saw A, Milow P, Song C
    Health Informatics J, 2023;29(4):14604582231218530.
    PMID: 38019888 DOI: 10.1177/14604582231218530
    The paediatric orthopaedic expert system analyses and predicts the healing time of limb fractures in children using machine learning. As far we know, no published research on the paediatric orthopaedic expert system that predicts paediatric fracture healing time using machine learning has been published. The University Malaya Medical Centre (UMMC) offers paediatric orthopaedic data, comprises children under the age of 12 radiographs limb fractures with ages recorded from the date and time of initial trauma. SVR algorithms are used to predict and discover variables associated with fracture healing time. This study developed an expert system capable of predicting healing time, which can assist general practitioners and healthcare practitioners during treatment and follow-up. The system is available online at https://kidsfractureexpert.com/.
    Matched MeSH terms: Orthopedics*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links