Displaying publications 61 - 80 of 97 in total

Abstract:
Sort:
  1. Srivastava S
    Med J Malaysia, 2000 Sep;55 Suppl C:44-8.
    PMID: 11200044
    The treatment of displaced supracondylar fracture humerus (Gartland Type III) in children continues to be a challenging problem. We did a retrospective study of such fractures treated in Hospital Muar, over a 2 years period (from January 1998 to December 1999). A total of 42 cases with displaced supracondylar fractures, treated with open reduction and internal fixation were studied. All cases were operated using a posterior triceps splitting approach and crossed kirschner wires were used to stabilize the fracture site. An excellent outcome was seen in 34 patients (81%) and a good outcome in 7 patients (17%). The incidence of complications such as pin tract infection (14%), nerve injury (2%) was very low. None of the patients had vascular complications or myositis ossificans.
    Matched MeSH terms: Fracture Fixation, Internal
  2. Chuah SK, Bajuri MY, Mohd Nor F
    Cureus, 2019 Jun 28;11(6):e5023.
    PMID: 31501722 DOI: 10.7759/cureus.5023
    Chronic osteomyelitis treatment is always a challenge to orthopaedic surgeons which requires great dedication and perseverance. We report a successful limb salvage case of a 46-year-old man who suffered from a left tibia chronic osteomyelitis with soft tissue defect. The treatment approach was a thorough wound debridement of devitalized tissues and necrotized bone, commencement of culture-directed antibiotics, reconstruction with vascularized osteomyocutaneous fibula flap, and skeletal stabilization with internal fixation. As compared to below knee amputation, the result we obtained in this case is more promising with regard to mobility and function.
    Matched MeSH terms: Fracture Fixation, Internal
  3. Choudhari P, Padia D
    Malays Orthop J, 2018 Nov;12(3):38-42.
    PMID: 30555645 DOI: 10.5704/MOJ.1811.008
    Introduction: Plating in distal tibia fractures are associated with higher rate of soft tissue complications. As adequate soft tissue cover is available over anterolateral surface of the tibia, use of anterolateral plate fixation in distal tibia fractures has increased. The purpose of our research is to evaluate the outcomes of anterolateral locking plate fixation in distal tibia fractures using ORIF. Materials and Methods: A retrospective analysis of 25 patients, who had distal tibia fractures and underwent open reduction and anterolateral plating. Bone and soft tissue healing and complications encountered were analysed. Result: Full weight bearing was allowed at an average of 5.4 months (range: 3-12 months) after seeing radiological union. We have observed superficial wound infection in four cases. Two cases had marginal necrosis, two cases had sensory disturbance over dorsolateral aspect of foot and two cases had delayed non-union. Mean length of surgical incision was 9cm (range: 5-12 cm). Conclusion: Open reduction internal fixation of distal tibia fractures with anterolateral plating is a reliable way of fracture fixation and stabilisation with proper surgical technique and aseptic precautions.
    Matched MeSH terms: Fracture Fixation, Internal
  4. Subash Y
    Malays Orthop J, 2021 Mar;15(1):48-54.
    PMID: 33880148 DOI: 10.5704/MOJ.2103.008
    Introduction: Fractures of the proximal tibia are high velocity injuries often associated with soft tissue compromise especially in the type V and VI fracture patterns. Dual plating is the preferred treatment option for these injuries but not in a setting where there is extensive soft tissue injury, as this can lead to problems with wound healing. The aim of this study was to evaluate the functional outcome following hybrid external fixation in the management of Schatzkers type V and VI fractures.

    Materials and Methods: A total of 30 patients with type V and VI proximal tibial fractures who presented between January 2012 to January 2015 were managed with hybrid external fixation and were followed-up for a period of 3 years.

    Results: The mean age of the patients was 42.26 years with the left knee being more commonly affected. Schatzkers type V was the more common fracture type seen. The mean time to union was 12.06 weeks and the average range of motion achieved was 0 to 100°. The mean Rasmussens functional score was 25.4 at last follow-up and we had excellent results in 5 patients and good results in 22 patients.

    Conclusion: Through this study, we conclude that the hybrid external fixation is an excellent option in the type V and VI fractures with extensive soft tissue compromise. It is easy to apply, facilitates early mobilisation of the joint and gives good functional results.

    Matched MeSH terms: Fracture Fixation, Internal
  5. Arumugam S, Kandasamy J, Md Shah AU, Hameed Sultan MT, Safri SNA, Abdul Majid MS, et al.
    Polymers (Basel), 2020 Jul 06;12(7).
    PMID: 32640502 DOI: 10.3390/polym12071501
    This study aims to explore the mechanical properties of hybrid glass fiber (GF)/sisal fiber (SF)/chitosan (CTS) composite material for orthopedic long bone plate applications. The GF/SF/CTS hybrid composite possesses a unique sandwich structure and comprises GF/CTS/epoxy as the external layers and SF/CTS/epoxy as the inner layers. The composite plate resembles the human bone structure (spongy internal cancellous matrix and rigid external cortical). The mechanical properties of the prepared hybrid sandwich composites samples were evaluated using tensile, flexural, micro hardness, and compression tests. The scanning electron microscopic (SEM) images were studied to analyze the failure mechanism of these composite samples. Besides, contact angle (CA) and water absorption tests were conducted using the sessile drop method to examine the wettability properties of the SF/CTS/epoxy and GF/SF/CTS/epoxy composites. Additionally, the porosity of the GF/SF/CTS composite scaffold samples were determined by using the ethanol infiltration method. The mechanical test results show that the GF/SF/CTS hybrid composites exhibit the bending strength of 343 MPa, ultimate tensile strength of 146 MPa, and compressive strength of 380 MPa with higher Young's modulus in the bending tests (21.56 GPa) compared to the tensile (6646 MPa) and compressive modulus (2046 MPa). Wettability study results reveal that the GF/SF/CTS composite scaffolds were hydrophobic (CA = 92.41° ± 1.71°) with less water absorption of 3.436% compared to the SF/CTS composites (6.953%). The SF/CTS composites show a hydrophilic character (CA = 54.28° ± 3.06°). The experimental tests prove that the GF/SF/CTS hybrid composite can be used for orthopedic bone fracture plate applications in future.
    Matched MeSH terms: Fracture Fixation, Internal
  6. Ramachandran Rubenandran, Rampal Sanjiv, Sivalingarajah Prema, Tan Eng Kee, Devaraj Navin Kumar
    MyJurnal
    Intramedullary nailing is the preferred method of closed shaft fracture fixation of long bones. One of the most dread- ed complications to occur following internal fixation of a lower limb fracture is pseudo- or false aneurysm which can lead to the loss of the limb due to acute ischemia. This diagnosis is made by contrast angiogram of the limb. Pointers to the diagnosis include absent distal limb pulsation as well as other signs of acute ischemia post trauma or surgery. We present a case of development of pseudo-aneurysm in an elderly patient following open reduction and internal fixation of a femoral fracture. This case report outlines a prompt multidisciplinary approach of management in a rare case of pseudoaneurysm post fixation of long bone.
    Matched MeSH terms: Fracture Fixation, Internal
  7. Yeap EJ, Rao J, Pan CH, Soelar SA, Younger ASE
    Foot Ankle Surg, 2016 Sep;22(3):164-169.
    PMID: 27502224 DOI: 10.1016/j.fas.2015.06.008
    BACKGROUND: This study compares the outcomes of calcaneal fracture surgery after open reduction internal fixation and plating (ORIF) versus arthroscopic assisted percutaneous screw fixation (APSF).

    METHODS: Group I (N=12) underwent ORIF. Group II (N=15) underwent APSF. Anthropometric data, pre and post-operative stay, complications and duration off work were recorded in this retrospective case cohort study. Radiographs were analyzed for Bohler's, Gissane's angle and Sanders' classification. AOFAS Hindfoot and SF 36 scores were collected at final follow-up.

    RESULTS: Anthropometric data, Bohler's and Gissane's angles, AOFAS and SF 36 scores were not significantly different. Pre-operative duration was 12.3 days in ORIF and 6.9 days in APSF. Post-operative duration was 7.3 days vs 3.8 days. Duration off work was 6.2 months vs 2.9 months.

    CONCLUSION: The APSF group was able to have surgery earlier, go home faster, and return to work earlier. This study was not powered to demonstrate a difference in wound complication rates.

    Matched MeSH terms: Fracture Fixation, Internal/adverse effects; Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods
  8. Ong, T.K., Chee, E.K., Wong, C.L., Thevarajan, K.
    Malays Orthop J, 2008;2(2):40-42.
    MyJurnal
    In comminuted patellar fractures, a combination of cerclage wiring and tension band fixation is said to provide good mechanical stability. This is a retrospective review of four patients treated with this method. All fractures described herein were classified as 45-C3 (based on Orthopaedic Trauma Association classification) and were fixed with a 1.25mm cerclage wire and tension band wire proximally looped through the quadriceps tendon and distally through the patellar ligament in a figure-of-eight configuration. The average follow-up period was 10 months. The Activity of Daily Living Scale (ADLS) of the Knee Outcome Survey was used to assess symptoms and functional capability of the knee. In all the cases, fracture union was achieved at an average of 11 weeks. The average ADLS score was good (92.5 %). Full range of knee motion was achieved by end of the third postoperative month. None of the patients had complications, such as infection and implant failure.
    Matched MeSH terms: Fracture Fixation, Internal
  9. Mohamed-Haflah NH, Kassim Y, Zuchri I, Zulmi W
    Malays Orthop J, 2017 Mar;11(1):28-34.
    PMID: 28435571 MyJurnal DOI: 10.5704/MOJ.1703.013
    INTRODUCTION: The role of surgery in skeletal metastasis is to reduce morbidity and improve the quality of life in terminally ill patients. We report our experience with patients who underwent skeletal reconstructive surgery for metastatic bone tumour of the femur.

    MATERIALS AND METHODS: Twenty nine operations for skeletal metastasis of the femur performed in our centre between 2009 and 2015 were included in this study. We evaluated the choice of implant, complications, survival rate and functional outcome. Fourteen patients were still alive at the time of this report for assessment of functional outcome using Musculoskeletal Tumour Society (MSTS) form.

    RESULTS: Plating osteosynthesis with augmented-bone cement was the most common surgical procedure (17 patients) performed followed by arthroplasty (10 patients) and intramedullary nailing (2 patients) There were a total of five complications which were implant failures (2 patients), surgical site infection (2 patients), and site infection mortality (1 patient). The median survival rate was eight months. For the functional outcome, the mean MSTS score was 66%.

    CONCLUSION: Patients with skeletal metastasis may have prolonged survival and should undergo skeletal reconstruction to reduce morbidity and improve quality of life. The surgical construct should be stable and outlast the patient to avoid further surgery.

    Matched MeSH terms: Fracture Fixation, Internal
  10. Nazri Mohd Yusof, Ahmad Hafiz Zulkifly, Kamarul Ariffin Khalid, Zamzuri Zakaria, Aminuddin Che Ahmad, Mohamed Azril Mohamed Amin, et al.
    MyJurnal
    This is a prospective study on infection following fixation of closed fractures done in Hospital Tengku Ampuan Afzan ,Kuantan from May 2003 to May 2005. There were 23 cases in this study. The mean age of patient was 32.9 years (range 15 to 77). Twenty one were males and 2 females. Twenty (87%) infections occurred in the lower limb and only 3(13%) occurred in the upper limbs. Twenty two patients (91%) had plating done for the fracture. Infection following internal fixation is commonly a deep seated (96%) and florid (78%) infection in which 70% occur after the surgical wound has healed. Staphylococcus aureus is the commonest organism isolated in which 43% are Methicillin resistant (MRSA). Overall infection caused by gram negative organisms is more common than gram positive organisms.
    Matched MeSH terms: Fracture Fixation, Internal
  11. Kow RY, Mustapha Zakaria Z, Khan ESKM, Low C
    J Orthop Case Rep, 2019 3 28;8(6):65-67.
    PMID: 30915298 DOI: 10.13107/jocr.2250-0685.1262
    Introduction: Fracture of the ulnar coronoid process is uncommon. It is commonly associated with posterior dislocation of the elbow, but it may also present as an isolated fracture. In general, all ulnar coronoid process fractures with elbow joint instability and large fracture fragments are fixed surgically. We report two cases of the rare isolated Regan-Morrey type III ulnar coronoid process fractures and their outcomes.

    Case Report: Case Report 1: Mrs P, a 27-year-old right-hand dominant female, was involved in a motor vehicle accident (MVA) and sustained an isolated Regan-Morrey type III ulnar coronoid process fracture. In view of the large coronoid process fragment causing elbow joint instability, she underwent an open reduction and internal fixation when the elbow swelling had subsided. An anterior approach was used to identify the fracture fragment and it was fixed with two half-threaded cancellous lag screws with washers to achieve an anatomical reduction. Postoperatively, she recovered with excellent outcome based on the Mayo elbow performance score (MEPS).Case Report 2: Mr M, a 23-year-old right-hand dominant gentleman, was involved in a MVA and sustained an isolated Regan-Morrey type III ulnar coronoid process fracture. During examination under general anesthesia, passive range of the movement of his right elbow was noted to be <90°due to the impaction of the fracture fragment. An open reduction through an anterior approach was performed and Kirschner wires were inserted to fix the coronoid process fracture. Kirschner wires were opted for the ease of post-operative removal as the patient was not keen to have a retained implant after recovery. He recovered with good outcome based on the MEPS.

    Conclusion: Isolated fracture of the ulnar coronoid process is rare. Open reduction and internal fixation is mandatory for patients with coronoid process fracture and unstable elbow joint to achieve good functional outcomes.

    Matched MeSH terms: Fracture Fixation, Internal
  12. Bajuri MY, Johan RR, Shukur H
    BMJ Case Rep, 2013;2013.
    PMID: 23576653 DOI: 10.1136/bcr-2013-008631
    Fat embolism syndrome (FES) is a continuum of fat emboli. Variants of FES: acute fulminant form and classic FES are postulated to represent two different pathomechanisms. Acute fulminant FES occurs during the first 24 h. It is attributed to massive mechanical blockage pulmonary vasculature by the fat emboli. The classic FES typically has a latency period of 24-36 h manifestation of respiratory failure and other signs of fat embolism. Progression of asymptomatic fat embolism with FES frequently represents inadequate treatment of hypovolaemic shock. We present a rare case of two variants of FES evolving in a patient with multiple fractures to emphasis the importance of adequate and appropriate treatment of shock in preventing the development of FES. Since supportive therapy which is a ventilatory support remains as the treatment of FES, it is appropriate to treat FES in the intensive care unit setting.
    Matched MeSH terms: Fracture Fixation, Internal/methods
  13. Yusof NM, Oh CW, Oh JK, Kim JW, Min WK, Park IH, et al.
    Injury, 2009 Dec;40(12):1286-91.
    PMID: 19539282 DOI: 10.1016/j.injury.2009.02.020
    Although non-operative treatment is a mainstay of tibial fracture management in children, certain fractures require a surgical approach. However, choices concerning optimal methods and implants are difficult. The purpose of this study was to determine the effectiveness of percutaneous plating of tibial fractures in children.
    Matched MeSH terms: Fracture Fixation, Internal/methods*
  14. Yusof MI, Ming LK, Abdullah MS
    J Orthop Surg (Hong Kong), 2007 Aug;15(2):187-90.
    PMID: 17709859
    To measure the cervical pedicles and assess the feasibility of transpedicular fixation in a Malay population.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  15. Ling HT, Kwan MK, Chua YP, Deepak AS, Ahmad TS
    Med J Malaysia, 2006 Dec;61 Suppl B:8-12.
    PMID: 17600986
    Treatment of radius or ulna nonunion requires both osteogenic environment and mechanical stability. We would like to report three radial and six ulnar diaphyseal nonunions treated with 3.5 mm locking compression plate (LCP) fixation. To assess the effectiveness of 3.5 mm LCP in treating diaphyseal nonunion of the forearm bones, we prospectively reviewed nine patients with the mean age of 33 years with diaphyseal nonunion of the radius or ulna. All patients were treated with 3.5 mm LCP. Bone grafting was only performed for atrophic nonunion. Surgical and functional outcome were evaluated. There were three atrophic nonunion of the radius, four atrophic nonunion of the ulna and two hypertrophic nonunion of the ulna. All nonunion united successfully with satisfactory functional outcome. 3.5 mm LCP is effective in the treatment of nonunion of ulna or radius.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  16. Ngeow WC, Lian CB
    Singapore Dent J, 1996 Jul;21(1):16-8.
    PMID: 10597177
    Fractures of the mandible and their management are discussed in detail in textbooks and articles dealing with facial trauma. This paper presents the management and treatment of a case of a unilateral comminuted and complicated fracture of the mandible due to dog attack on a geriatric patient. The attack also severed the patient's right arm. Due to the severity of the trauma, an emergency surgery was performed on the mandible and arm.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation
  17. Chung WH, Eu WC, Chiu CK, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2019 12 27;28(1):2309499019888977.
    PMID: 31876259 DOI: 10.1177/2309499019888977
    PURPOSE: To describe the reduction technique of thoracolumbar burst fracture using percutaneous monoaxial screws and its radiological outcomes compared to polyaxial screws.

    METHODS: All surgeries were performed by minimally invasive technique with either percutaneous monoaxial or percutaneous polyaxial screws inserted at adjacent fracture levels perpendicular to both superior end plates. Fracture reduction is achieved with adequate rod contouring and distraction maneuver. Radiological parameters were measured during preoperation, postoperation, and follow-up.

    RESULTS: A total of 21 patients were included. Eleven patients were performed with monoaxial pedicle screws and 10 patients performed with polyaxial pedicle screws. Based on AO thoracolumbar classification system, 10 patients in the monoaxial group had A3 fracture type and 1 had A4. In the polyaxial group, six patients had A3 and four patients had A4. Total correction of anterior vertebral height (AVH) ratio was 0.30 ± 0.10 and 0.08 ± 0.07 in monoaxial and polyaxial groups, respectively (p < 0.001). Total correction of posterior vertebral height (PVH) ratio was 0.11 ± 0.05 and 0.02 ± 0.02 in monoaxial and polyaxial groups, respectively (p < 0.001). Monoaxial group achieved more correction of 13° (62.6%) in local kyphotic angle compared to 8.2° (48.0%) in polyaxial group. Similarly, in regional kyphotic angle, 16.5° (103.1%) in the monoaxial group and 8.1° (76.4%) in the polyaxial group were achieved.

    CONCLUSIONS: Monoaxial percutaneous pedicle screws inserted at adjacent fracture levels provided significantly better fracture reduction compared to polyaxial screws in thoracolumbar fractures.

    Matched MeSH terms: Fracture Fixation, Internal/methods*
  18. Devnani AS
    Singapore Med J, 2002 Apr;43(4):205-7.
    PMID: 12188067
    Fracture neck of the femur is rare in children and occurs following severe trauma. Several recommendations have been made for the treatment of displaced transcervical fracture type 11 (Delbet classification). However there are no recommendations when such a fracture occurs after recent acute osteomyelits of the neck of the femur. The management of a case is described with the outcome after 36 months.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  19. Muhammad Abdul Jamil MK, Abdul Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 May;22(3):207-12.
    PMID: 22182834 DOI: 10.1097/BPB.0b013e32834ecc01
    This preliminary report is on two patients with congenital pseudoarthrosis of the tibia who had a persistent nonunion following intramedullary rodding and bone grafting. We do not advocate repeated surgery to achieve union. When limb length discrepancy becomes greater than 5 cm, we proceeded with an Ilizarov procedure with the primary aim of equalizing limb length rather than achieving union. Healing of the pseudoarthrosis occurred in both patients after lengthening over the intramedullary rod without compression of the nonunion site. We believe that union occurs because of hyperaemia during the lengthening. This approach minimizes the repeated surgeries that are usually needed and thus ensures a more normal childhood without frequent hospitalizations.
    Matched MeSH terms: Fracture Fixation, Internal/adverse effects*; Fracture Fixation, Internal/methods
  20. Miswan MF, Singh VA, Yasin NF
    Ulus Travma Acil Cerrahi Derg, 2011 Nov;17(6):504-8.
    PMID: 22290002 DOI: 10.5505/tjtes.2011.04809
    We reviewed cases with Lisfranc injuries who presented to our center in order to study the adequacy of the treatment method and their final functional outcome.
    Matched MeSH terms: Fracture Fixation, Internal/statistics & numerical data*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links