Displaying publications 61 - 80 of 262 in total

Abstract:
Sort:
  1. Fahlman A, Bosi EJ, Nyman G
    J. Zoo Wildl. Med., 2006 Dec;37(4):558-61.
    PMID: 17315446
    Medetomidine (0.02-0.06 mg/kg) in combination with zolazepam-tiletamine (0.8-2.3 mg/kg) were evaluated for reversible anesthesia in four species of Southeast Asian primates: Bornean orangutan (Pongo pygmaeus pygmaeus), Bornean gibbon (Hylobates muelleri), long-tailed macaque (Macaca fascicularis), and pig-tailed macaque (Macaca nemestrina). Twenty-three anesthetic procedures of captive-held and free-ranging primates were studied in Sabah, Malaysia. The induction was smooth and rapid. Respiratory and heart rates were stable throughout anesthesia, whereas body temperature and systolic arterial blood pressure decreased significantly. Atipamezole at five times the medetomidine dose effectively reversed anesthesia, with first signs of recovery within 3-27 min.
    Matched MeSH terms: Heart Rate/drug effects
  2. Khan SA, Sattar MA, Rathore HA, Abdulla MH, Ud Din Ahmad F, Ahmad A, et al.
    Acta Physiol (Oxf), 2014 Mar;210(3):690-700.
    PMID: 24438102 DOI: 10.1111/apha.12237
    There is evidence that in chronic renal failure, the sympathetic nervous system is activated. This study investigated the role of the renal innervation in suppressing high- and low-pressure baroreflex control of renal sympathetic nerve activity and heart rate in cisplatin-induced renal failure.
    Matched MeSH terms: Heart Rate/physiology*
  3. Mir IA, Chowdhury M, Islam RM, Ling GY, Chowdhury AABM, Hasan ZM, et al.
    J Clin Hypertens (Greenwich), 2021 02;23(2):317-322.
    PMID: 33347732 DOI: 10.1111/jch.14126
    Prevalence of pre-hypertension is higher among young adults and may increase the risk for hypertension and cardiovascular morbidity. Music therapy has been investigated to reduce the blood pressure in the hypertensive population; however, its efficacy on blood pressure in pre-hypertensive young adults is not known. Thirty pre-hypertensive (systolic blood pressure [SBP] = 120-139 mmHg and diastolic blood pressure [DBP] = 80-89 mmHg) young adults were recruited and randomly assigned into two groups. Music group (N = 15) received music therapy by passive listening to music for 30 minutes/day, 5 days/week for 4 weeks, along with Dietary Approaches to Stop Hypertension (DASH) eating plan (a diet rich in fruits and vegetables, low-fat dairy or unsaturated fat) and limit the daily sodium intake less than 100 mmol/day. The control group (N = 15) practiced only DASH eating plan and sodium restriction. The SBP, DBP, and heart rate (HR) were measured before and after 4 weeks of intervention. There was a significant reduction in SBP (8.73 mmHg, p 
    Matched MeSH terms: Heart Rate
  4. Mirza FT, Jenkins S, Justine M, Cecins N, Hill K
    Respirology, 2018 Jul;23(7):674-680.
    PMID: 29446206 DOI: 10.1111/resp.13262
    BACKGROUND AND OBJECTIVE: There is increased use of the 2-min walk test (2MWT) to assess functional exercise capacity. However, the distance achieved during this test may be difficult to interpret in the absence of reference values from a local population. Regression equations to estimate the 2-min walk distance (2MWD) only exist for American and Brazilian populations. The objective of this study was to develop regression equations to estimate the 2MWD in Malaysian adults who were free from major health problems.
    METHODS: Eighty-seven adults (43 males; mean ± SD age: 57.1 ± 9.6 years) performed two 2MWT using a standardized protocol. Heart rate (HR) was recorded every 30 s during the test. Stepwise multiple regression analysis was performed using age, gender, height, weight and change in HR (ΔHR) as independent variables, and better of the two 2MWD as the dependent variable. A second regression equation, without ΔHR, was planned if ΔHR was retained as one of the predictors of the 2MWD in the first equation.
    RESULTS: The better of the two 2MWD was 200 ± 34 m. Males walked 33 ± 6 m further than females (P < 0.001). The two regression equations were 196 - 1.1 × age, years + 1.0 × ΔHR, bpm + 31.2 × gender (R2 = 0.73) and 279 - 1.7 × age, years + 35.9 × gender (R2 = 0.47) with females = 0 and males = 1.
    CONCLUSION: The equations derived in this study may facilitate the interpretation of the 2MWD in clinical populations in Malaysia, as well as in countries with similar cultural backgrounds to Malaysia.
    Study site: volunteers from four villages in the Batu sub-district, Gombak, Malaysia
    Matched MeSH terms: Heart Rate
  5. Tomitani N, Hoshide S, Buranakitjaroen P, Chia YC, Park S, Chen CH, et al.
    J Clin Hypertens (Greenwich), 2021 03;23(3):606-613.
    PMID: 33694262 DOI: 10.1111/jch.14239
    Increased heart rate is a predictor of cardiovascular disease, heart failure, and all-cause mortality. In those with high heart rates, interventions for heart rate reduction have been associated with reductions in coronary events. Asia is a diverse continent, and the prevalences of hypertension and cardiovascular disease differ among its countries. The present analysis of AsiaBP@Home study data investigated differences among resting heart rates (RHRs) in 1443 hypertensive patients from three Asian regions: East Asia (N = 595), Southeast Asia (N = 680), and South Asia (N = 168). This is the first study to investigate self-measured RHR values in different Asian countries/regions using the same validated home BP monitoring device (Omron HEM-7130-AP/HEM-7131-E). Subjects in South Asia had higher RHR values compared with the other two regions, and the regional tendency found in RHR values was different from that found in BP values. Even after adjusting for age, sex, BMI, habitual alcohol consumption, current smoking habit, shift worker, hyperlipidemia, diabetes, chronic kidney disease, history of heart failure, and beta-blocker use, both office and home RHR values in South Asia were the highest among Asia (mean values ± SE of office: East Asia [E] 75.2 ± 1.5 bpm, Southeast Asia [Se] 76.7 ± 1.5 bpm, South Asia [S] 81.9 ± 1.4 bpm; home morning: [E] 69.0 ± 1.2 bpm, [Se] 72.9 ± 1.2 bpm, [S] 74.9 ± 1.1 bpm; home evening: [E] 74.6 ± 1.2 bpm, [Se] 78.3 ± 1.2 bpm, [S] 83.8 ± 1.1 bpm). Given what is known about the impact of RHR on heart disease, our findings suggest the possible benefit of regionally tailored clinical strategies for cardiovascular disease prevention.
    Matched MeSH terms: Heart Rate
  6. Ahmad S, Valli H, Smyth R, Jiang AY, Jeevaratnam K, Matthews HR, et al.
    J Cell Physiol, 2019 Apr;234(4):3921-3932.
    PMID: 30146680 DOI: 10.1002/jcp.27183
    Peroxisome proliferator-activated receptor-γ coactivator-1 deficient (Pgc-1β-/- ) murine hearts model the increased, age-dependent, ventricular arrhythmic risks attributed to clinical conditions associated with mitochondrial energetic dysfunction. These were accompanied by compromised action potential (AP) upstroke rates and impaired conduction velocities potentially producing arrhythmic substrate. We tested a hypothesis implicating compromised Na+ current in these electrophysiological phenotypes by applying loose patch-clamp techniques in intact young and aged, wild-type (WT) and Pgc-1β-/- , ventricular cardiomyocyte preparations for the first time. This allowed conservation of their in vivo extracellular and intracellular conditions. Depolarising steps elicited typical voltage-dependent activating and inactivating inward Na+ currents with peak amplitudes increasing or decreasing with their respective activating or preceding inactivating voltage steps. Two-way analysis of variance associated Pgc-1β-/- genotype with independent reductions in maximum peak ventricular Na+ currents from -36.63 ± 2.14 (n = 20) and -35.43 ± 1.96 (n = 18; young and aged WT, respectively), to -29.06 ± 1.65 (n = 23) and -27.93 ± 1.63 (n = 20; young and aged Pgc-1β-/- , respectively) pA/μm2 (p 
    Matched MeSH terms: Heart Rate*
  7. Ibrahimy MI, Ahmed F, Mohd Ali MA, Zahedi E
    IEEE Trans Biomed Eng, 2003 Feb;50(2):258-62.
    PMID: 12665042
    An algorithm based on digital filtering, adaptive thresholding, statistical properties in the time domain, and differencing of local maxima and minima has been developed for the simultaneous measurement of the fetal and maternal heart rates from the maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. A microcontroller-based system has been used to implement the algorithm in real-time. A Doppler ultrasound fetal monitor was used for statistical comparison on five volunteers with low risk pregnancies, between 35 and 40 weeks of gestation. Results showed an average percent root mean square difference of 5.32% and linear correlation coefficient from 0.84 to 0.93. The fetal heart rate curves remained inside a +/- 5-beats-per-minute limit relative to the reference ultrasound method for 84.1% of the time.
    Matched MeSH terms: Heart Rate/physiology; Heart Rate, Fetal/physiology*
  8. Chazova IE, Dongre N, Vigdorchik AV
    Adv Ther, 2011 Feb;28(2):134-49.
    PMID: 21240661 DOI: 10.1007/s12325-010-0099-1
    The aim of our study was to evaluate the safety and effectiveness of the free combination of amlodipine/valsartan in patients with arterial hypertension in a real-life setting.
    Matched MeSH terms: Heart Rate/drug effects*
  9. Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, et al.
    Heart Rhythm, 2017 02;14(2):200-205.
    PMID: 27871854 DOI: 10.1016/j.hrthm.2016.11.016
    BACKGROUND: The Micra transcatheter pacemaker was designed to have similar functionality to conventional transvenous VVIR pacing systems. It provides rate adaptive pacing using a programmable 3-axis accelerometer designed to detect patient activity in the presence of cardiac motion.

    OBJECTIVE: The purpose of this study was to evaluate the system's performance during treadmill tests to maximum exertion in a subset of patients within the Micra Transcatheter Pacing Study.

    METHODS: Patients underwent treadmill testing at 3 or 6 months postimplant with algorithm programming at physician discretion. Normalized sensor rate (SenR) relative to the programmed upper sensor rate was modeled as a function of normalized workload in metabolic equivalents (METS) relative to maximum METS achieved during the test. A normalized METS and SenR were determined at the end of each 1-minute treadmill stage. The proportionality of SenR to workload was evaluated by comparing the slope from this relationship to the prospectively defined tolerance margin (0.65-1.35).

    RESULTS: A total of 69 treadmill tests were attempted by 42 patients at 3 and 6 months postimplant. Thirty tests from 20 patients who completed ≥4 stages with an average slope of 0.86 (90% confidence interval 0.77-0.96) confirmed proportionality to workload. On an individual test basis, 25 of 30 point estimates (83.3%) had a normalized slope within the defined tolerance range (range 0.46-1.08).

    CONCLUSION: Accelerometer-based rate adaptive pacing was proportional to workload, thus confirming rate adaptive pacing commensurate to workload is achievable with an entirely intracardiac pacing system.

    Matched MeSH terms: Heart Rate
  10. Liew KB, Loh GO, Tan YT, Peh KK
    Biomed Chromatogr, 2014 Sep;28(9):1246-53.
    PMID: 24585432 DOI: 10.1002/bmc.3153
    The objectives of this study were to develop a new deproteinization method to extract amoxicillin from human plasma and evaluate the inter-ethnic variation of amoxicillin pharmacokinetics in healthy Malay volunteers. A single-dose, randomized, fasting, two-period, two-treatment, two-sequence crossover, open-label bioequivalence study was conducted in 18 healthy Malay adult male volunteers, with one week washout period. The drug concentration in the sample was analyzed using high-performance liquid chromatography (UV-vis HPLC). The mean (standard deviation) pharmacokinetic parameter results of Moxilen® were: peak concentration (Cmax ), 6.72 (1.56) µg/mL; area under the concentration-time graph (AUC0-8 ), 17.79 (4.29) µg/mL h; AUC0-∞ , 18.84 (4.62) µg/mL h. Those of YSP Amoxicillin® capsule were: Cmax , 6.69 (1.44) µg/mL; AUC0-8 , 18.69 (3.78) µg/mL h; AUC00-∞ , 19.95 (3.81) µg/mL h. The 90% confidence intervals for the logarithmic transformed Cmax , AUC0-8 and AUC0-∞ of Moxilen® vs YSP Amoxicillin® capsule was between 0.80 and 1.25. Both Cmax and AUC met the predetermined criteria for assuming bioequivalence. Both formulations were well tolerated. The results showed significant inter-ethnicity variation in pharmacokinetics of amoxicillin. The Cmax and AUC of amoxicillin in Malay population were slightly lower compared with other populations.
    Matched MeSH terms: Heart Rate/drug effects
  11. Goh PK, Chiu CL, Wang CY, Chan YK, Loo PL
    Anaesth Intensive Care, 2005 Apr;33(2):223-8.
    PMID: 15960405
    The aim of this prospective, double-blind, randomized, placebo-controlled clinical trial was to investigate whether the administration of ketamine before induction with propofol improves its associated haemodynamic profile and laryngeal mask airway (LMA) insertion conditions. Ninety adult patients were randomly allocated to receive either ketamine 0.5 mg x kg(-1) (n = 30), fentanyl 1 microg x kg(-1) (n = 30) or normal saline (n = 30), before induction of anaesthesia with propofol 2.5 mg x kg(-1). Insertion of the LMA was performed 60s after injection of propofol. Arterial blood pressure and heart rate were measured before induction (baseline), immediately after induction, immediately before LMA insertion, immediately after LMA insertion and every minute for three minutes after LMA insertion. Following LMA insertion, the following six subjective endpoints were graded by a blinded anaesthestist using ordinal scales graded 1 to 3: mouth opening, gagging, swallowing, movement, laryngospasm and ease of insertion. Systolic blood pressure was significantly higher following ketamine than either fentanyl (P = 0.010) or saline (P = 0.0001). The median (interquartile range) summed score describing the overall insertion conditions were similar in the ketamine [median 7.0, interquartile range (6.0-8.0)] and fentanyl groups [median 7.0, interquartile range (6.0-8.0)]. Both appeared significantly better than the saline group [median 8.0, interquartile range (6.75-9.25); P = 0.024]. The incidence of prolonged apnoea (> 120s) was higher in the fentanyl group [23.1% (7/30)] compared with the ketamine [6.3% (2/30)] and saline groups [3.3% (1/30)]. We conclude that the addition of ketamine 0.5 mg x kg(-1) improves haemodynamics when compared to fentanyl 1 microg x kg(-1), with less prolonged apnoea, and is associated with better LMA insertion conditions than placebo (saline).
    Matched MeSH terms: Heart Rate/drug effects*
  12. Roslan J, Giribabu N, Karim K, Salleh N
    Biomed Pharmacother, 2017 Feb;86:570-582.
    PMID: 28027533 DOI: 10.1016/j.biopha.2016.12.044
    Quercetin is known to possess beneficial effects in ameliorating diabetic complications, however the mechanisms underlying cardioprotective effect of this compound in diabetes is not fully revealed. In this study, quercetin effect on oxidative stress, inflammation and apoptosis in the heart in diabetes were investigated. Normal and streptozotocin-nicotinamide induced adult male diabetic rats received quercetin (10, 25 and 50mg/kg/bw) orally for 28days were anesthetized and hemodynamic parameters i.e. systolic blood pressure (SBP), diastolic blood pressure (DBP) and heart rate (HR) were measured. Blood was collected for analyses of fasting glucose (FBG), insulin and cardiac injury marker levels (troponin-C, CK-MB and LDH). Following sacrificed, heart was harvested and histopathological changes were observed. Heart was subjected for analyses of oxidative stress marker i.e. lipid peroxidation and activity and expression levels of anti-oxidative enzymes i.e. SOD, CAT and GPx. Levels of inflammation in the heart were determined by measuring nuclear factor (p65-NF-κB), tumor necrosis factor (TNF-α), interleukins (IL)-1β and IL-6 levels by using enzyme-linked immunoassay (ELISA). Distribution and expression levels of TNF-α and Ikk-β (inflammatory markers), caspase-3, caspase-9, Blc-2 and Bax (apoptosis markers) in the heart were identified by immunohistochemistry and Western blotting respectively.
    Matched MeSH terms: Heart Rate/drug effects
  13. Kazemipoor M, Radzi CW, Hajifaraji M, Cordell GA
    Phytother Res, 2014 Oct;28(10):1456-60.
    PMID: 24638976 DOI: 10.1002/ptr.5147
    Carum carvi L. (Apiaceae) is known as caraway, and its derivatives find wide medicinal use for health purposes, including for gastrointestinal problems and obesity. Since there is inconsistency among the reports on the safety of this plant in humans, this research was aimed at assessing the safety of a characterized caraway aqueous extract (CAE) in a randomized, triple-blind, placebo-controlled study. Seventy, overweight and obese, healthy women were randomly assigned into placebo (n = 35) and plant extract (n = 35) groups. Participants received either 30 ml/day of CAE or placebo. Subjects were examined at baseline and after 12 weeks for changes in heart rate, blood pressure, urine test, 25-item blood chemistries, and general health status. No significant changes of blood pressure, heart rate, urine specific gravity, and serum blood tests were observed between the two groups before and after treatment. However, in the complete blood count test, red blood cell levels were significantly (p 
    Matched MeSH terms: Heart Rate
  14. Cheah HY, Kiew LV, Lee HB, Japundžić-Žigon N, Vicent MJ, Hoe SZ, et al.
    J Appl Toxicol, 2017 Nov;37(11):1268-1285.
    PMID: 28165137 DOI: 10.1002/jat.3437
    While nano-sized construct (NSC) use in medicine has grown significantly in recent years, reported unwanted side effects have raised safety concerns. However, the toxicity of NSCs to the cardiovascular system (CVS) and the relative merits of the associated evaluation methods have not been thoroughly studied. This review discusses the toxicological profiles of selected NSCs and provides an overview of the assessment methods, including in silico, in vitro, ex vivo and in vivo models and how they are related to CVS toxicity. We conclude the review by outlining the merits of telemetry coupled with spectral analysis, baroreceptor reflex sensitivity analysis and echocardiography as an appropriate integrated strategy for the assessment of the acute and chronic impact of NSCs on the CVS. Copyright © 2017 John Wiley & Sons, Ltd.
    Matched MeSH terms: Heart Rate/drug effects
  15. Nazrolnizah Mohamad Noorzeli, Muhammad Nubli Abdul Wahab
    MyJurnal
    The ability to enhance the entrepreneurial skills of small entrepreneurs is the key factor to the increase
    in business. Nevertheless, previous literature showed that there is less current study which focused on
    the methods to improve entrepreneurial skills using Biofeedback techniques among entrepreneurs in
    Malaysia. Thus, this study was aimed to: 1) Identifying the demographic background of small
    entrepreneurs, 2) Identify management capabilities among entrepreneurs in entrepreneurial skills and 3) Identify the profile of Heart Rate Variability (HRV) among small entrepreneurs through increased the
    HF coherence. A total of 50 respondents of small entrepreneurs were recruited in this study. The data
    collected involved a questionnaire survey with participants, profit and sales analysis and analysis of
    HRV. Statistical correlation analysis was used to examine the relationship between entrepreneurial
    skills and business insights from the point of HRV. The finding shows that there is a very strong
    relationship between the increases in entrepreneurial skills from an increase in business with the profile
    of HRV among participants with the score of 0.80-1.00. This showed that HRV Biofeedback training
    technique is appropriate to be used as an intervention program to increse entrepreneurship skills among
    small entrepreneurs in Malaysia.
    Matched MeSH terms: Heart Rate
  16. Ariff, M.S., Mai Ashikin, N.T., Maryamjameelah, R., Bushra, J., Wan Azman, W.A.
    MyJurnal
    Qur’anic verses recitations to ill patients are practiced by many Muslims as a form of healing and worship. The effectiveness has been observed in many medical institutions; however, it has never been objectively measured and documented. This pilot study was conducted to construct a methodological approach to evaluate the therapeutic effects of Yasiin recitation on the haemodynamics of critically ill patients. Methods: Ventilated Muslim patients in coronary care unit of a teaching hospital were evaluated. Yasiin was recited twice; by one of the researchers and then by the patients’ relatives. Mean arterial blood pressure, pulse rate, oxygen saturation level and electrocardiographic changes, were observed. The difference of the parameters before and during recitation was analysed. Results: Five patients fulfilling the selection criteria were selected; two acute myocardial infarctions, two congestive cardiac failures, and a third-degree atrioventricular block. Based on a non-parametric two-related-sample test, the haemodynamic parameters were not significantly affected by Yaasiin recitation. At the end of the study, two of the patients passed away, one patient was extubated and survived. Two patients were still on ventilators when the study had been completed. Limitations in the study were observed and highlighted in explaining the equivocal results. Conclusions: The effect of Yasiin recitation on heamodynamics of patients was not proven in this study. Further refinements might be needed based upon the observation on limitations encountered. It is hoped that this humble effort would pave the way for further studies to explore this field.
    Matched MeSH terms: Heart Rate
  17. Hébert-Losier K, Yin NS, Beaven CM, Tee CCL, Richards J
    J Electromyogr Kinesiol, 2019 Feb;44:36-45.
    PMID: 30496944 DOI: 10.1016/j.jelekin.2018.11.009
    Kinesiology-type tape (KTT) has become popular in sports for injury prevention, rehabilitation, and performance enhancement. Many cyclists use patella KTT; however, its benefits remain unclear, especially in uninjured elite cyclists. We used an integrated approach to investigate acute physiological, kinematic, and electromyographic responses to patella KTT in twelve national-level male cyclists. Cyclists completed four, 4-minute submaximal efforts on an ergometer at 100 and 200 W with and without patella KTT. Economy, energy cost, oxygen cost, heart rate, efficiency, 3D kinematics, and lower-body electromyography signals were collected over the last minute of each effort. Comfort levels and perceived change in knee stability and performance with KTT were recorded. The effects of KTT were either unclear, non-significant, or clearly trivial on all collected physiological and kinematic measures. KTT significantly, clearly, and meaningfully enhanced vastus medialis peak, mean, and integrated electromyographic signals, and vastus medialis-to-lateralis activation. Electromyographic measures from biceps femoris and biceps-to-rectus femoris activation ratio decreased in either a significant or clinically meaningful manner. Despite most cyclists perceiving KTT as comfortable, increasing stability, and improving performance, the intervention exerted no considerable effects on all physiological and kinematic measures. KTT did alter neuromuscular recruitment, which has potential implications for injury prevention.
    Matched MeSH terms: Heart Rate
  18. Duncan MT, Horvath SM
    PMID: 3396569
    Young sedentary adult males of Malay, Indian, and Chinese origin who had established continuous residence in tropical Malaysia and presumed to be naturally acclimatized to heat, were studied to evaluate their physiological responses to a standard heat stress test. The Malay and Indian races have evolved in hot and humid geographical zones, whereas the Chinese originated from a temperate area. Subjects exercised at 50% VO2max alternating 18 minutes walking and 2 min rest during a 2-h exposure to an ambient of 34.9 degrees C dry bulb and 32.1 degrees C wet bulb. Heart rates, core and skin temperatures, sweat rates, and oxygen uptakes were measured during the heat exposure. The subjects of Malay origin exhibited the least circulatory stress of the three ethnic groups. The data obtained on these long-term residents of a hot-wet climate and who were considered acclimatized to this environment were compared to experimental data obtained by other investigators and other ethnic groups.
    Matched MeSH terms: Heart Rate
  19. Vengatasubramani, M., Vikram, M.
    Medicine & Health, 2014;9(2):109-113.
    MyJurnal
    Chronic obstructive pulmonary disease (COPD) patients are reported to have cardiovascular instability which leads to greater limitation for activities there by leads to poor quality of life. Physical training proved to be one of the moderators of these limitations. However, uncertainty prevails among the protocol and duration. The present study investigated the effect of physical training on blood pressure, heart rate and Rate pressure Product (RPP) among COPD patients. A total of thirty COPD patients aged between 40 to 55 years were recruited for the study based on the inclusion and exclusion criteria and were assigned in to experimental group (15 patients) and control group (15 patients). The mean difference of blood pressure, heart rate and RPP were analyzed using paired t-test. There was significant difference between the pre and post test values of all parameters between experimental and control group with p< 0.05. Diastolic blood pressure showed to be less significant compared to the systolic blood pressure. This showed that specifically designed physical improved the cardiovascular fitness among COPD patients.
    Matched MeSH terms: Heart Rate
  20. Rashid, A.S., Khatun, S., Ali, B.M., Khazani, A.M.
    ASM Science Journal, 2008;2(1):13-22.
    MyJurnal
    An analysis of the power spectral density of ultra-wideband (UWB) signals is presented in order to evaluate the effects of cumulative interference from multiple UWB devices on victim narrowband systems in their overlay bands like WiFi (i.e. IEEE802.11a) and 3rdG systems (Universal mobile telecommunications system/wideband code division multiple access). In this paper, the performances are studied through the bit-error-rate as a function of signal-to-noise ratio as well as signal-to-interference power ratio using computer simulation and exploiting the realistic channel model (i.e. modified Saleh-Valenzuela model). Several modifications of a generic Gaussian pulse waveform with lengths in the order of nanoseconds were used to generate UWB spectra. Different kinds of pulse modulation (i.e. antipodal and orthogonal) schemes were also taken into account.
    Matched MeSH terms: Heart Rate
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links