  1. Cheng Y, Lai OM, Tan CP, Panpipat W, Cheong LZ, Shen C
    ACS Appl Mater Interfaces, 2021 Jan 27;13(3):4146-4155.
    PMID: 33440928 DOI: 10.1021/acsami.0c17134
    Immobilization can be used to improve the stability of lipases and enhances lipase recovery and reusability, which increases its commercial value and industrial applications. Nevertheless, immobilization frequently causes conformational changes of the lipases, which decrease lipase catalytic activity. in the present work, we synthesized UIO-66 and grafted UIO-66 crystals with proline for immobilization of Candida rugosa lipase (CRL). As indicated by steady-state fluorescence microscopy, grafting of proline onto UIO-66 crystals induced beneficial conformational change in CRL. CRL immobilized on UIO-66/Pro (CRL@UIO-66/Pro) demonstrated higher enzyme activity and better recyclability than that immobilized on UIO-66 (CRL@UIO-66) in both hydrolysis (CRL@UIO-66/Pro: 0.34 U; CRL@UIO-66: 0.15 U) and transesterification (CRL@UIO-66/Pro: 0.93 U; CRL@UIO-66: 0.25 U) reactions. The higher values of kcat and kcat/Km of CRL@UIO-66/Pro also showed that it had better catalytic efficiency as compared to CRL@UIO-66. It is also worth noting that CRL@UIO-66/Pro (0.93 U) demonstrated a much higher transesterification activity as compared to free CRL (0.11 U), indicating that UIO-66/Pro has increased the solvent stability of CRL. Both CRL@UIO-66 and CRL@UIO-66/Pro were also used for the fabrication of biosensors for nitrofen with a wide linear range (0-100 μM), lower limit of detection, and good recovery rate.
    Matched MeSH terms: Biosensing Techniques/methods
  2. Fathil MF, Md Arshad MK, Ruslinda AR, Nuzaihan M N M, Gopinath SC, Adzhri R, et al.
    Anal Chim Acta, 2016 Sep 07;935:30-43.
    PMID: 27543013 DOI: 10.1016/j.aca.2016.06.012
    A real-time ability to interpret the interaction between targeted biomolecules and the surface of semiconductors (metal transducers) into readable electrical signals, without biomolecular modification involving fluorescence dyes, redox enzymes, and radioactive labels, created by label-free biosensors has been extensively researched. Field-effect transistor (FET)- and capacitor-based biosensors are among the diverse electrical charge biosensing architectures that have drawn much attention for having charge transduction; thus, enabling the early and rapid diagnosis of the appropriate cardiac biomarkers at lower concentrations. These semiconducting material-based transducers are very suitable to be integrated with portable electronic devices for future online collection, transmission, reception, analysis, and reporting. This overview elucidates and clarifies two major electrical label-free systems (FET- and capacitor-based biosensors) with cardiac troponin (cTn) biomarker-mediated charge transduction for acute myocardial infarction (AMI) diagnosis. Advances in these systems are highlighted by their progression in bridging the laboratory and industry; the foremost technologies have made the transition from benchtop to bedside and beyond.
    Matched MeSH terms: Biosensing Techniques*
  3. Mohamad Nor N, Ridhuan NS, Abdul Razak K
    Biosensors (Basel), 2022 Dec 06;12(12).
    PMID: 36551103 DOI: 10.3390/bios12121136
    This review covers the progress of nanomaterial-modified electrodes for enzymatic and non-enzymatic glucose biosensors. Fundamental insights into glucose biosensor components and the crucial factors controlling the electrochemical performance of glucose biosensors are discussed in detail. The metal, metal oxide, and hybrid/composite nanomaterial fabrication strategies for the modification of electrodes, mechanism of detection, and significance of the nanomaterials toward the electrochemical performance of enzymatic and non-enzymatic glucose biosensors are compared and comprehensively reviewed. This review aims to provide readers with an overview and underlying concept of producing a reliable, stable, cost-effective, and excellent electrochemical performance of a glucose biosensor.
    Matched MeSH terms: Biosensing Techniques*
  4. Nurul Najian AB, Foo PC, Ismail N, Kim-Fatt L, Yean CY
    Mol Cell Probes, 2019 04;44:63-68.
    PMID: 30876924 DOI: 10.1016/j.mcp.2019.03.001
    This study highlighted the performance of the developed integrated loop-mediated isothermal amplification (LAMP) coupled with a colorimetric DNA-based magnetogenosensor. The biosensor operates through a DNA hybridization system in which a specific designed probe captures the target LAMP amplicons. We demonstrated the magnetogenosensor assay by detecting pathogenic Leptospira, which causes leptospirosis. The color change of the assay from brown to blue indicated a positive result, whereas a negative result was indicated by the assay maintaining its brown color. The DNA biosensor was able to detect DNA at a concentration as low as 200 fg/μl, which is equivalent to 80 genomes/reaction. The specificity of the biosensor assay was 100% when it was evaluated with 172 bacterial strains. An integrated LAMP and probe-specific magnetogenosensor was successfully developed, promising simple and rapid visual detection in clinical diagnostics and service as a point-of-care device.
    Matched MeSH terms: Biosensing Techniques/methods*
  5. Saeedfar K, Heng LY, Ling TL, Rezayi M
    Sensors (Basel), 2013;13(12):16851-66.
    PMID: 24322561 DOI: 10.3390/s131216851
    A novel method for the rapid modification of fullerene for subsequent enzyme attachment to create a potentiometric biosensor is presented. Urease was immobilized onto the modified fullerene nanomaterial. The modified fullerene-immobilized urease (C60-urease) bioconjugate has been confirmed to catalyze the hydrolysis of urea in solution. The biomaterial was then deposited on a screen-printed electrode containing a non-plasticized poly(n-butyl acrylate) (PnBA) membrane entrapped with a hydrogen ionophore. This pH-selective membrane is intended to function as a potentiometric urea biosensor with the deposition of C60-urease on the PnBA membrane. Various parameters for fullerene modification and urease immobilization were investigated. The optimal pH and concentration of the phosphate buffer for the urea biosensor were 7.0 and 0.5 mM, respectively. The linear response range of the biosensor was from 2.31 × 10-3 M to 8.28 × 10-5 M. The biosensor's sensitivity was 59.67 ± 0.91 mV/decade, which is close to the theoretical value. Common cations such as Na+, K+, Ca2+, Mg2+ and NH4+ showed no obvious interference with the urea biosensor's response. The use of a fullerene-urease bio-conjugate and an acrylic membrane with good adhesion prevented the leaching of urease enzyme and thus increased the stability of the urea biosensor for up to 140 days.
    Matched MeSH terms: Biosensing Techniques/instrumentation*; Biosensing Techniques/methods*
  6. Parmin NA, Hashim U, Gopinath SCB, Nadzirah S, Salimi MN, Voon CH, et al.
    Crit Rev Anal Chem, 2021 Jun 07.
    PMID: 34092138 DOI: 10.1080/10408347.2021.1890543
    The importance of nanotechnology in medical applications especially with biomedical sensing devices is undoubted. Several medical diagnostics have been developed by taking the advantage of nanomaterials, especially with electrical biosensors. Biosensors have been predominantly used for the quantification of different clinical biomarkers toward detection, screening, and follow-up the treatment. At present, ovarian cancer is one of the severe complications that cannot be identified until it becomes most dangerous as the advanced stage. Based on the American Cancer Society, 20% of cases involved in the detection of ovarian cancer are diagnosed at an early stage and 80% diagnosed at the later stages. The patient just has a common digestive problem and stomach ache as early symptoms and people used to ignore these symptoms. Micro ribonucleic acid (miRNA) is classified as small non-coding RNAs, their expressions change due to the association of cancer development and progression. This article reviews and discusses on the currently available strategies for the early detection of ovarian cancers using miRNA as a biomarker associated with electrical biosensors. A unique miRNA-based biomarker detections are specially highlighted with biosensor platforms to diagnose ovarian cancer.
    Matched MeSH terms: Biosensing Techniques
  7. Balakrishnan SR, Hashim U, Gopinath SC, Poopalan P, Ramayya HR, Veeradasan P, et al.
    Biosens Bioelectron, 2016 Oct 15;84:44-52.
    PMID: 26560969 DOI: 10.1016/j.bios.2015.10.075
    Rationally designed biosensing system supports multiplex analyses is warranted for medical diagnosis to determine the level of analyte interaction. The chemically functionalized novel multi-electrode polysilicon nanogap (PSNG) lab-on-chip is designed in this study, facilitates multiplex analyses for a single analyte. On the fabricated 69nm PSNG, biocompatibility and structural characteristics were verified for the efficient binding of Human Chorionic Gonadotropin (hCG). With the assistance of microfluidics, hCG sample was delivered via single-injection to 3-Aminopropyl(triethoxy)silane (APTES) and Glycidoxypropyl(trimethoxy)silane (GPMS) modified PSNG electrodes and the transduced signal was used to investigate the dielectric mechanisms for multiplex analyses. The results from amperometric response and impedance measurement delivered the scale of interaction between anti-hCG antibody and hCG that exhibited 6.5 times higher sensitivity for the chemical linker, APTES than GPMS. Under optimized experimental conditions, APTES and GPMS modified immunosensor has a limit of detection as 0.56mIU/ml and 2.93mIU/ml (at S/N=3), with dissociation constants (Kd) of 5.65±2.5mIU/ml and 7.28±2.6mIU/ml, respectively. These results suggest that multiplex analysis of single target could enhance the accuracy of detection and reliable for real-time comparative analyses. The designed PSNG is simple, feasible, requires low sample consumption and could be applied for any given multiplex analyses.
    Matched MeSH terms: Biosensing Techniques/instrumentation*
  8. Hosseini S, Azari P, Farahmand E, Gan SN, Rothan HA, Yusof R, et al.
    Biosens Bioelectron, 2015 Jul 15;69:257-64.
    PMID: 25765434 DOI: 10.1016/j.bios.2015.02.034
    Electrospun polyhydroxybutyrate (PHB) fibers were dip-coated by polymethyl methacrylate-co-methacrylic acid, poly(MMA-co-MAA), which was synthesized in different molar ratios of the monomers via free-radical polymerization. Fabricated platfrom was employed for immobilization of the dengue antibody and subsequent detection of dengue enveloped virus in enzyme-linked immunosorbent assay (ELISA). There is a major advantage for combination of electrospun fibers and copolymers. Fiber structre of electrospun PHB provides large specific surface area available for biomolecular interaction. In addition, polymer coated parts of the platform inherited the premanent presence of surface carboxyl (-COOH) groups from MAA segments of the copolymer which can be effectively used for covalent and physical protein immobilization. By tuning the concentration of MAA monomers in polymerization reaction the concentration of surface -COOH groups can be carefully controlled. Therefore two different techniques have been used for immobilization of the dengue antibody aimed for dengue detection: physical attachment of dengue antibodies to the surface and covalent immobilization of antibodies through carbodiimide chemistry. In that perspective, several different characterization techniques were employed to investigate the new polymeric fiber platform such as scanning electron microscopy (SEM), atomic force microscopy (AFM), water contact angle (WCA) measurement and UV-vis titration. Regardless of the immobilization techniques, substantially higher signal intensity was recorded from developed platform in comparison to the conventional ELISA assay.
    Matched MeSH terms: Biosensing Techniques/instrumentation*
  9. Azila AA, Barbari T, Searson P
    Med J Malaysia, 2004 May;59 Suppl B:51-2.
    PMID: 15468814
    Considerable effort has been focused on the method of immobilizing glucose oxidase (GOD) for amperometric glucose biosensors since the technique employed may influence the available activity of the enzyme and thus affect the performance of the sensor. Narrow measuring range and low current response are still considered problems in this area. In this work, poly(vinyl alcohol)(PVA) was investigated as a potential matrix for GOD immobilization. GOD was entrapped in cross-linked PVA. The use of a PVA-GOD membrane as the enzymatic component of a glucose biosensor was found to be promising in both the magnitude of its signal and its relative stability over time. The optimum PVA-GOD membrane (cross-linking density of 0.06) was obtained through careful selection of the cross-linking density of the PVA matrix.
    Matched MeSH terms: Biosensing Techniques*
  10. Eddin FBK, Fen YW, Liew JYC, Daniyal WMEMM
    Biosensors (Basel), 2022 Dec 03;12(12).
    PMID: 36551091 DOI: 10.3390/bios12121124
    Surface plasmonic sensors have received considerable attention, found extensive applications, and outperformed conventional optical sensors. In this work, biopolymer chitosan (CS) was used to prepare the bilayer structure (CS/Au) of a plasmonic refractive index sensor for dopamine (DA) detection. The sensing characteristics of the developed plasmonic sensor were evaluated. Increasing DA concentrations significantly shifted the SPR dips. The sensor exhibited stability and a refractive index sensitivity of 8.850°/RIU in the linear range 0.1 nM to 1 µM with a detection limit of 0.007 nM and affinity constant of 1.383 × 108 M-1. The refractive index and thickness of the CS/Au structure were measured simultaneously by fitting the obtained experimental findings to theoretical data based on Fresnel equations. The fitting yielded the refractive index values n (1.5350 ± 0.0001) and k (0.0150 ± 0.0001) for the CS layer contacting 0.1 nM of DA, and the thickness, d was (15.00 ± 0.01) nm. Then, both n and d values increased by increasing DA concentrations. In addition, the changes in the FTIR spectrum and the variations in sensor surface roughness and structure obtained by AFM analysis confirmed DA adsorption on the sensing layer. Based on these observations, CS/Au bilayer has enhanced the performance of this plasmonic sensor, which showed promising importance as a simple, low-cost, and reliable platform for DA sensing.
    Matched MeSH terms: Biosensing Techniques*
  11. El-Sayed AM, Hamzaid NA, Abu Osman NA
    Sensors (Basel), 2014;14(12):23724-41.
    PMID: 25513823 DOI: 10.3390/s141223724
    Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0-100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types.
    Matched MeSH terms: Biosensing Techniques/methods*
  12. Issa, R., Hamdan, N.A., Raj, A.S.S., Noh, M.F.M.
    ASM Science Journal, 2011;5(1):36-42.
    MyJurnal
    Researchers have developed and modified DNA biosensor techniques to provide a fast, simple and sensitive method for detection of human diseases, bacterial food contamination, forensic and environmental research. This study describes the physical characterization of screen-printed carbon electrodes using the scanning electron microscope.
    Matched MeSH terms: Biosensing Techniques
  13. Shing WL, Heng LY, Surif S
    Sensors (Basel), 2013;13(5):6394-404.
    PMID: 23673679 DOI: 10.3390/s130506394
    Whole cell biosensors always face the challenge of low stability of biological components and short storage life. This paper reports the effects of poly(2-hydroxyethyl methacrylate) (pHEMA) immobilization on a whole cell fluorescence biosensor for the detection of heavy metals (Cu, Pb, Cd), and pesticides (dichlorophenoxyacetic acid (2,4-D), and chlorpyrifos). The biosensor was produced by entrapping the cyanobacterium Anabaena torulosa on a cellulose membrane, followed by applying a layer of pHEMA, and attaching it to a well. The well was then fixed to an optical probe which was connected to a fluorescence spectrophotometer and an electronic reader. The optimization of the biosensor using several factors such as amount of HEMA and drying temperature were undertaken. The detection limits of biosensor without pHEMA for Cu, Cd, Pb, 2,4-D and chlorpyrifos were 1.195, 0.027, 0.0100, 0.025 and 0.025 µg/L respectively. The presence of pHEMA increased the limits of detection to 1.410, 0.250, 0.500, 0.235 and 0.117 µg/L respectively. pHEMA is known to enhance the reproducibility of the biosensor with average relative standard deviation (RSD) of ±1.76% for all the pollutants tested, 48% better than the biosensor without pHEMA (RSD = ±3.73%). In storability test with Cu 5 µg/L, the biosensor with pHEMA performed 11.5% better than the test without pHEMA on day-10 and 5.2% better on day-25. pHEMA is therefore a good candidate to be used in whole cell biosensors as it increases reproducibility and enhances biosensor storability.
    Matched MeSH terms: Biosensing Techniques/methods*
  14. Ahmad N, Colak B, Gibbs MJ, Zhang DW, Gautrot JE, Watkinson M, et al.
    Biomacromolecules, 2019 07 08;20(7):2506-2514.
    PMID: 31244015 DOI: 10.1021/acs.biomac.9b00245
    Inflammatory conditions are frequently accompanied by increased levels of active proteases, and there is rising interest in methods for their detection to monitor inflammation in a point of care setting. In this work, new sensor materials for disposable single-step protease biosensors based on poly(2-oxazoline) hydrogels cross-linked with a protease-specific cleavable peptide are described. The performance of the sensor material was assessed targeting the detection of matrix metalloproteinase-9 (MMP-9), a protease that has been shown to be an indicator of inflammation in multiple sclerosis and other inflammatory conditions. Films of the hydrogel were formed on gold-coated quartz crystals using thiol-ene click chemistry, and the cross-link density was optimized. The degradation rate of the hydrogel was monitored using a quartz crystal microbalance (QCM) and showed a strong dependence on the MMP-9 concentration. A concentration range of 0-160 nM of MMP-9 was investigated, and a lower limit of detection of 10 nM MMP-9 was determined.
    Matched MeSH terms: Biosensing Techniques*
  15. Ahmad N, Colak B, Zhang DW, Gibbs MJ, Watkinson M, Becer CR, et al.
    Sensors (Basel), 2019 Apr 08;19(7).
    PMID: 30965649 DOI: 10.3390/s19071677
    Peptide cross-linked poly(ethylene glycol) hydrogel has been widely used for drug delivery and tissue engineering. However, the use of this material as a biosensor for the detection of collagenase has not been explored. Proteases play a key role in the pathology of diseases such as rheumatoid arthritis and osteoarthritis. The detection of this class of enzyme using the degradable hydrogel film format is promising as a point-of-care device for disease monitoring. In this study, a protease biosensor was developed based on the degradation of a peptide cross-linked poly(ethylene glycol) hydrogel film and demonstrated for the detection of collagenase. The hydrogel was deposited on gold-coated quartz crystals, and their degradation in the presence of collagenase was monitored using a quartz crystal microbalance (QCM). The biosensor was shown to respond to concentrations between 2 and 2000 nM in less than 10 min with a lower detection limit of 2 nM.
    Matched MeSH terms: Biosensing Techniques*
  16. Lim WY, Thevarajah TM, Goh BT, Khor SM
    Biosens Bioelectron, 2019 Mar 01;128:176-185.
    PMID: 30685097 DOI: 10.1016/j.bios.2018.12.049
    The early detection of acute myocardial infarction (AMI) upon the onset of chest pain symptoms is crucial for patient survival. However, this detection is challenging, particularly without a persistent elevation of ST-segment reflected in an electrocardiogram or in blood tests. A majority of the available point-of-care testing devices allow accurate and rapid diagnosis of AMI. However, AMI diagnosis is reliable only at intermediate and later stages, with myocardial injury (> 6 h) and MI, based on the expression of specific cardiac biomarkers including troponin I or T (cTnI or cTnT), creatine kinase-MB (CK-MB), and myoglobin. Diagnosis at the early myocardial ischemia stage is not possible. To overcome this limitation, a sensitive and rapid microfluidic paper-based device (µPAD) was developed for the simultaneous detection of multiple cardiac biomarkers for the early and late diagnosis of AMI. The glycogen phosphorylase isoenzyme BB (GPBB) was detected during early (within first 4 h) ischemic myocardial injury. On the same µPAD platform, detection of prolonged elevation of levels of cTnT and CK-MB, which are only produced 6 h after the onset of chest pain in human serum, was possible. Sandwich immunoassay performed on the µPAD achieved reproducibility (RSD approximately 10% and intra-and inter-day precision (CV 10-20%, 99th percentile), as well as consistently stable test results for 28 days, with strong correlation (r2= 0.962), using the standard Siemens Centaur XPT Immunoassay system. The present findings indicate the potential of the µPAD platform as a point-of-care device for the early diagnosis and prognosis of AMI.
    Matched MeSH terms: Biosensing Techniques*
  17. Makhsin SR, Goddard NJ, Gupta R, Gardner P, Scully PJ
    Anal Chem, 2020 11 17;92(22):14907-14914.
    PMID: 32378876 DOI: 10.1021/acs.analchem.0c00586
    The metal-clad leaky waveguide (MCLW) is an optical biosensor consisting of a metal layer and a low index waveguide layer on a glass substrate. This label-free sensor measures refractive index (RI) changes within the waveguide layer. This work shows the development and optimization of acrylate based-hydrogel as the waveguide layer formed from PEG diacrylate (PEGDA, Mn 700), PEG methyl ether acrylate (PEGMEA, Mn 480), and acrylate-PEG2000-NHS fabricated on a substrate coated with 9.5 nm of titanium. The acrylate-based hydrogel is a synthetic polymer, so properties such as optical transparency, porosity, and hydrogel functionalization by a well-controlled reactive group can be tailored for immobilization of the bioreceptor within the hydrogel matrix. The waveguide sensor demonstrated an equal response to solutions of identical RI containing small (glycerol) and large (bovine serum albumin; BSA) analyte molecules, indicating that the hydrogel waveguide film is highly porous to both sizes of molecule, thus potentially allowing penetration of a range of analytes within the porous matrix. The final optimized MCLW chip was formed from a total hydrogel concentration of 40% v/v of PEGMEA-PEGDA (Mn 700), functionalized with 2.5% v/v of acrylate-PEG2000-NHS. The sensor generated a single-moded waveguide signal with a RI sensitivity of 128.61 ± 0.15° RIU-1 and limit of detection obtained at 2.2 × 10-6 RIU with excellent signal-to-noise ratio for the glycerol detection. The sensor demonstrated RI detection by monitoring changes in the out-coupled angle resulting from successful binding of d-biotin to streptavidin immobilized on functionalized acrylate hydrogel, generating a binding signal of (12.379 ± 0.452) × 10-3°.
    Matched MeSH terms: Biosensing Techniques/instrumentation*
  18. Syamimi Haslan, Lee YH, Goh CT, Ling LT
    Sains Malaysiana, 2018;47:2027-2033.
    Biosensor optik berasaskan hemoglobin (Hb) terpegun pada mikrosfera poli(n-butil akrilat-co-N-akriloksisuksinimida)
    [poli(nBA-NAS)] telah dibangunkan bagi mengesan kepekatan ion nitrit (NO2
    -
    ). Kompleks HEM ferum dalam Hb
    memangkinkan tindak balas penurunan ion NO2
    -
    kepada nitrik oksida (NO) lalu bergabung dengan deoksihemoglobin
    (HbFe2+) membentuk kompleks ferum-nitrosil-hemoglobin (HbFe2+-NO) yang berwarna hijau kekuningan. Spektrofotometer
    pantulan gentian optik digunakan untuk memantau kepekatan ion NO2
    -
    secara kuantitatif berdasarkan perubahan warna
    Hb terpegun pada mikrosfera poliakrilat daripada perang kemerahan ke hijau kekuningan pada panjang gelombang
    pantulan maksimum 668 nm. Pencirian terhadap biosensor nitrit reflektometrik melibatkan ujian kesan pH, kesan
    kepekatan Hb, julat rangsangan linear, kebolehasilan, jangka hayat dan kesan gangguan ion telah dijalankan. Biosensor
    ion NO2
    - optik terbangun memaparkan julat linear dinamik daripada 5 hingga 50 mg mL-1 (R2
    =0.9894) pada pH7.0 dengan
    had pengesanan (LOD) sebanyak 3.3 mg mL-1 dan nilai sisihan piawai relatif (RSD) kebolehasilan biosensor sebanyak
    5.8%. Jangka hayat biosensor optik nitrit tersebut adalah selama 36 hari dan majoriti ion asing yang sering wujud
    bersama ion NO2
    - dalam sampel air semula jadi tidak menunjukkan kesan gangguan yang bererti terhadap penentuan
    ion NO2
    -
    menggunakan biosensor optik terbangun kecuali ion Hg2+, Ag+, Br-
    dan S2-.
    Matched MeSH terms: Biosensing Techniques
  19. Kausar AS, Reza AW, Latef TA, Ullah MH, Karim ME
    Sensors (Basel), 2015 Apr 15;15(4):8787-831.
    PMID: 25884787 DOI: 10.3390/s150408787
    The concept of optical antennas in physical optics is still evolving. Like the antennas used in the radio frequency (RF) regime, the aspiration of optical antennas is to localize the free propagating radiation energy, and vice versa. For this purpose, optical antennas utilize the distinctive properties of metal nanostructures, which are strong plasmonic coupling elements at the optical regime. The concept of optical antennas is being advanced technologically and they are projected to be substitute devices for detection in the millimeter, infrared, and visible regimes. At present, their potential benefits in light detection, which include polarization dependency, tunability, and quick response times have been successfully demonstrated. Optical antennas also can be seen as directionally responsive elements for point detectors. This review provides an overview of the historical background of the topic, along with the basic concepts and parameters of optical antennas. One of the major parts of this review covers the use of optical antennas in biosensing, presenting biosensing applications with a broad description using different types of data. We have also mentioned the basic challenges in the path of the universal use of optical biosensors, where we have also discussed some legal matters.
    Matched MeSH terms: Biosensing Techniques/methods*
  20. Haron S, Ray AK
    Med Eng Phys, 2006 Dec;28(10):978-81.
    PMID: 17018258
    A three layer waveguiding silicon dioxide (SiO(2))/silicon nitride (Si(3)N(4))/SiO(2) structure on silicon substrate was proposed as an optically efficient biosensor for calibration of heavy metal ions in drinking water. The catalytic activities of urease and acetylcholine esterase (AchE) were inhibited by the presence of cadmium (Cd(2+)) and lead (Pb(2+)) ions. The detection limit as low as 1 ppb was achieved by employing the technique of total reflection at the interface between the Si(3)N(4) core and composite polyelectrolyte self-assembled (PESA) membranes containing cyclotetrachromotropylene (CTCT) as an indicator.
    Matched MeSH terms: Biosensing Techniques/methods*