Displaying publications 81 - 100 of 118 in total

Abstract:
Sort:
  1. Vitee N, Ramiah H, Chong WK, Tan GH, Kanesan J, Reza AW
    ScientificWorldJournal, 2014;2014:683971.
    PMID: 25133252 DOI: 10.1155/2014/683971
    A low-power wideband mixer is designed and implemented in 0.13 µm standard CMOS technology based on resistive feedback current-reuse (RFCR) configuration for the application of cognitive radio receiver. The proposed RFCR architecture incorporates an inductive peaking technique to compensate for gain roll-off at high frequency while enhancing the bandwidth. A complementary current-reuse technique is used between transconductance and IF stages to boost the conversion gain without additional power consumption by reusing the DC bias current of the LO stage. This downconversion double-balanced mixer exhibits a high and flat conversion gain (CG) of 14.9 ± 1.4 dB and a noise figure (NF) better than 12.8 dB. The maximum input 1-dB compression point (P1dB) and maximum input third-order intercept point (IIP3) are -13.6 dBm and -4.5 dBm, respectively, over the desired frequency ranging from 50 MHz to 10 GHz. The proposed circuit operates down to a supply headroom of 1 V with a low-power consumption of 3.5 mW.
    Matched MeSH terms: Electronics/instrumentation*; Electronics/methods
  2. LaDou J, Rohm T
    Int J Occup Environ Health, 1998 Jan-Mar;4(1):1-18.
    PMID: 10026464
    High-technology microelectronics has a major presence in countries such as China, India, Indonesia, and Malaysia, now the third-largest manufacturer of semiconductor chips. The migration of European, Japanese, and American companies accommodates regional markets. Low wage rates and limited enforcement of environmental regulations in developing countries also serve as incentives for the dramatic global migration of this industry. The manufacture of microelectonics products is accompanied by a high incidence of occupational illnesses, which may reflect the widespread use of toxic materials. Metals, photoactive chemicals, solvents, acids, and toxic gases are used in a wide variety of combinations and workplace settings. The industry also presents problems of radiation exposure and various occupational stressors, including some unresolved ergonomic issues. The fast-paced changes of the technology underlying this industry, as well as the stringent security precautions, have added to the difficulty of instituting proper health and safety measures. Epidemiologic studies reveal an alarming increase in spontaneous abortions among cleanroom manufacturing workers; no definitive study has yet identified its cause. Other health issues, including occupational cancer, are yet to be studied. The microelectronics industry is a good example of an industry that is exported to many areas of the world before health and safety problems are properly addressed and resolved.
    Matched MeSH terms: Electronics/organization & administration*
  3. Li Tsu Chong, Deena Clare Thomas, Renie Martha Joanes, Rose A Nain
    MyJurnal
    Introduction: Phlebitis may localise to the insertion site or travel along the vein. The risk of phlebitis is higher in children as they have thin and weak blood vessels and move continuously due to the pain associated with insertion. Therefore, regular assessment of the risk of developing phlebitis is crucial. This review aimed to identify infusion phlebitis assessment tool used in the paediatric setting. Methods: Electronic databases used were Scopus, ProQuest, ScienceDirect, and Google Scholar. A total of ten studies which assess the development of infusion phlebitis on hos- pitalised children included in this reviewed. Study findings were discussed and concluded with a recommendation for clinical practice and future studies. Results: Phlebitis development rate was the primary outcome measures in ten studies. Of ten studies, six provided no actual definition of phlebitis. Eight reported phlebitis incidence and/or severity, eight used a scale and two used a definition alone in assessing the development of phlebitis. This review identified five different phlebitis assessment scales. Conclusion: Although there are applicable phlebitis scales can be used for paediatric setting, Limited studies have been conducted on infusion phlebitis assessment method in chil- dren. Therefore, it is suggested that more studies and vigorous test needed to identify applicable assessment tools in paediatric setting.
    Matched MeSH terms: Electronics
  4. Sagadevan S, Chowdhury ZZ, Johan MRB, Aziz FA, Roselin LS, Podder J, et al.
    J Nanosci Nanotechnol, 2019 Nov 01;19(11):7139-7148.
    PMID: 31039868 DOI: 10.1166/jnn.2019.16666
    In this work, a simple, co-precipitation technique was used to prepare un-doped, pure tin oxide (SnO₂). As synthesized SnO₂ nanoparticles were doped with Cu2+ ions. Detailed characterization was carried out to observe the crystalline phase, morphological features and chemical constituents with opto-electrical and magnetic properties of the synthesized nanoparticles (NPs). X-ray diffraction analysis showed the existence of crystalline, tetragonal structure of SnO₂. Both the sample synthesized here showed different crystalline morphology. The band gap energy (Eg) of the synthesized sample was estimated and it was found to decrease from 3.60 to 3.26 eV. The band gap energy reduced due to increase in Cu2+ dopant amount inside the SnO₂ lattice. Optical properties were analyzed using absorption spectra and Photoluminescence (PL) spectra. It was observed that Cu2+ ions incorporated SnO₂ NPs exhibited more degradation efficiencies for Rhodamine B (RhB) dye compared to un-doped sample under UV-Visible irradiation. The dielectric characteristics of un-doped, pure and Cu2+ incorporated SnO₂ nanoparticles were studied at different frequency region under different temperatures. The ac conductivity and impedance analysis of pure and Cu2+ incorporated SnO₂ nanoparticles was also studied. The magnetic properties of the synthesized samples were analysed. Both the sample showed ferromagnetic properties. The research indicated that the Cu2+ ions doping can make the sample a promising candidate for using in the field of optoelectronics, magneto electronics, and microwave devices.
    Matched MeSH terms: Electronics
  5. Dey D, De D, Ahmadian A, Ghaemi F, Senu N
    Nanoscale Res Lett, 2021 Jan 29;16(1):20.
    PMID: 33512575 DOI: 10.1186/s11671-020-03467-x
    Doping is the key feature in semiconductor device fabrication. Many strategies have been discovered for controlling doping in the area of semiconductor physics during the past few decades. Electrical doping is a promising strategy that is used for effective tuning of the charge populations, electronic properties, and transmission properties. This doping process reduces the risk of high temperature, contamination of foreign particles. Significant experimental and theoretical efforts are demonstrated to study the characteristics of electrical doping during the past few decades. In this article, we first briefly review the historical roadmap of electrical doping. Secondly, we will discuss electrical doping at the molecular level. Thus, we will review some experimental works at the molecular level along with we review a variety of research works that are performed based on electrical doping. Then we figure out importance of electrical doping and its importance. Furthermore, we describe the methods of electrical doping. Finally, we conclude with a brief comparative study between electrical and conventional doping methods.
    Matched MeSH terms: Electronics
  6. Junaid HM, Batool M, Harun FW, Akhter MS, Shabbir N
    Crit Rev Anal Chem, 2020 Sep 08.
    PMID: 32897731 DOI: 10.1080/10408347.2020.1806703
    Spectacular color change during a chemical reaction is always fascinating. A variety of chemosensors including Schiff bases have been reported for selective as well as sensitive recognition of ions. This review explains the use of Schiff bases as color changing agents in the detection of anions. This magic of colors is attributed to change in the electronic structure of the system during reaction. Schiff base chemosensors are easy to synthesize, inexpensive and can be used for visual sensing of different ions. Development of Schiff base chemosensors is commonly based on the interactions between polar groups of Schiff bases and ionic species and the process of charge transfer, electron transfer and hydrogen bonding between Schiff bases and ionic species cause the color of the resultant to be changed. Therefore, designing of simple Schiff base chemosensors which are capable of selective sensing of different anions has attracted considerable interest. In particular, naked eye sensing through color change is important and useful since it allows sensing of ions through color changes without using any instrumental technique.HighlightsNaked eye sensors are of much interest these days due to their visual detection properties rather employing complex instrumentation.Optical sensors are sensitive, selective, cost effective and robust.The magic of color change is fascinating factor in detection by these sensors.The color change may be attributed by interaction between anion and Schiff base by different mechanism i.e. electron transfer, charge transfer, hydrogen bonding, ICT etc.LOD data is an evidence of their great efficiency.
    Matched MeSH terms: Electronics
  7. Shokrani MR, Khoddam M, Hamidon MN, Kamsani NA, Rokhani FZ, Shafie SB
    ScientificWorldJournal, 2014;2014:963709.
    PMID: 24782680 DOI: 10.1155/2014/963709
    This paper presents a new type diode connected MOS transistor to improve CMOS conventional rectifier's performance in RF energy harvester systems for wireless sensor networks in which the circuits are designed in 0.18  μm TSMC CMOS technology. The proposed diode connected MOS transistor uses a new bulk connection which leads to reduction in the threshold voltage and leakage current; therefore, it contributes to increment of the rectifier's output voltage, output current, and efficiency when it is well important in the conventional CMOS rectifiers. The design technique for the rectifiers is explained and a matching network has been proposed to increase the sensitivity of the proposed rectifier. Five-stage rectifier with a matching network is proposed based on the optimization. The simulation results shows 18.2% improvement in the efficiency of the rectifier circuit and increase in sensitivity of RF energy harvester circuit. All circuits are designed in 0.18 μm TSMC CMOS technology.
    Matched MeSH terms: Electronics/methods
  8. Rasool N, Ikram HM, Rashid A, Afzal N, Hashmi MA, Khan MN, et al.
    Turk J Chem, 2020;44(5):1410-1422.
    PMID: 33488240 DOI: 10.3906/kim-1911-51
    In the current research work, a facile synthesis of a series of novel thiophene-based derivatives of 5-bromothiophene-2-carboxylic acid ( 1 ) have been synthesized. All analogs ( 5a - 5e , 10a - 10f ) were obtained from the coupling reaction of 5-bromothiophene-2-carboxylic acid ( 1 ) and different arylboronic acids with moderate-to-good yields under controlled and optimal conditions. The structures of the newly synthesized compounds were characterized through spectral analysis and their spasmolytic activity, and most of the compounds exhibited potentially good spasmolytic effect. Among the synthesized analogs, compound phenethyl 5-(3,4-dichlorophenyl)thiophene-2-carboxylate ( 10d ) particular showed an excellent spasmolytic effect with an EC 50 value of 1.26. All of the compounds were also studied for their structural and electronic properties by density functional theory (DFT) calculations. Through detailed insight into frontier molecular orbitals of the compounds and their different reactivity descriptors, it was found that the compounds 10c and 5c are the most reactive, while 10a is the most stable in the series. Furthermore, compounds 10c and 5c showed a very good NLO response with the highest β values.
    Matched MeSH terms: Electronics
  9. Mimala Arasaratnam, Zailina Hashim, Shamsul Bahari Shamsudin
    MyJurnal
    A cross-sectional study was conducted on 83 female electronics factory workers. The respondents comprised 50 exposed workers who use lead alloy solder and 33 unexposed workers. The objective of this study was to assess the lead exposure of these workers. Breathing zone were sampled using air sampling pumps. Dust samples were collected by wipe method. Venous blood collected and blood pressure were measured. All lead analyses were carried out with Graphite Furnace Atomic Absorption Spectrophotometer. The mean air lead for exposed workers (57 0. ± 0.93 μg/m³) was significantly higher than the unexposed workers (0.0067 ± 0.0045μg/m³) (p
    Matched MeSH terms: Electronics
  10. Chee HL, Rashidah S, Shamsuddin K, Sharifah Zainiyah SY
    Med J Malaysia, 2003 Aug;58(3):320-9.
    PMID: 14750370
    A total of 486 Malaysian women electronics workers participated in a study of reproductive health knowledge and cancer screening. The practice of Breast Self Examination (BSE) was found to be related to educational attainment; while ever having had a Pap smear was found to be related to being older than 30 years old, being ever married, living with family or relatives, and not staying in hostels. Knowledge on reproductive health was found to be higher for older women, married women, living with family or relatives, not staying in hostels, ever having done BSE and ever having had a Pap smear.
    Matched MeSH terms: Electronics
  11. Jafar U, Aziz MJA, Shukur Z
    Sensors (Basel), 2021 Aug 31;21(17).
    PMID: 34502764 DOI: 10.3390/s21175874
    Online voting is a trend that is gaining momentum in modern society. It has great potential to decrease organizational costs and increase voter turnout. It eliminates the need to print ballot papers or open polling stations-voters can vote from wherever there is an Internet connection. Despite these benefits, online voting solutions are viewed with a great deal of caution because they introduce new threats. A single vulnerability can lead to large-scale manipulations of votes. Electronic voting systems must be legitimate, accurate, safe, and convenient when used for elections. Nonetheless, adoption may be limited by potential problems associated with electronic voting systems. Blockchain technology came into the ground to overcome these issues and offers decentralized nodes for electronic voting and is used to produce electronic voting systems mainly because of their end-to-end verification advantages. This technology is a beautiful replacement for traditional electronic voting solutions with distributed, non-repudiation, and security protection characteristics. The following article gives an overview of electronic voting systems based on blockchain technology. The main goal of this analysis was to examine the current status of blockchain-based voting research and online voting systems and any related difficulties to predict future developments. This study provides a conceptual description of the intended blockchain-based electronic voting application and an introduction to the fundamental structure and characteristics of the blockchain in connection to electronic voting. As a consequence of this study, it was discovered that blockchain systems may help solve some of the issues that now plague election systems. On the other hand, the most often mentioned issues in blockchain applications are privacy protection and transaction speed. For a sustainable blockchain-based electronic voting system, the security of remote participation must be viable, and for scalability, transaction speed must be addressed. Due to these concerns, it was determined that the existing frameworks need to be improved to be utilized in voting systems.
    Matched MeSH terms: Electronics
  12. Mendel B, Christianto, Setiawan M, Prakoso R, Siagian SN
    Curr Cardiol Rev, 2021 Jun 03.
    PMID: 34082685 DOI: 10.2174/1573403X17666210603113430
    BACKGROUND: Junctional ectopic tachycardia (JET) is an arrhythmia originating from the AV junction, which may occur following congenital heart surgery, especially when the intervention is near the atrioventricular junction.

    OBJECTIVE: The aim of this systematic review and meta-analysis is to compare the effectiveness of amiodarone, dexmedetomidine and magnesium in preventing JET following congenital heart surgery.

    METHODS: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement, where 11 electronic databases were searched from date of inception to August 2020. The incidence of JET was calculated with the relative risk of 95% confidence interval (CI). Quality assessment of the included studies was assessed using the Consolidated Standards of Reporting Trials (CONSORT) 2010 statement.

    RESULTS: Eleven studies met the predetermined inclusion criteria and were included in this meta-analysis. Amiodarone, dexmedetomidine and magnesium significantly reduced the incidence of postoperative JET [Amiodarone: risk ratio 0.34; I2= 0%; Z=3.66 (P=0.0002); 95% CI 0.19-0.60. Dexmedetomidine: risk ratio 0.34; I2= 0%; Z=4.77 (P<0.00001); 95% CI 0.21-0.52. Magnesium: risk ratio 0.50; I2= 24%; Z=5.08 (P<0.00001); 95% CI 0.39-0.66].

    CONCLUSION: All three drugs show promise in reducing the incidence of JET. Our systematic review found that dexmedetomidine is better in reducing the length of ICU stays as well as mortality. In addition, dexmedetomidine also has the least pronounced side effects among the three. However, it should be noted that this conclusion was derived from studies with small sample sizes. Therefore, dexmedetomidine may be considered as the drug of choice for preventing JET.

    Matched MeSH terms: Electronics
  13. Junaid M, Md Khir MH, Witjaksono G, Ullah Z, Tansu N, Saheed MSM, et al.
    Molecules, 2020 Sep 14;25(18).
    PMID: 32937975 DOI: 10.3390/molecules25184217
    In recent years, the field of nanophotonics has progressively developed. However, constant demand for the development of new light source still exists at the nanometric scale. Light emissions from graphene-based active materials can provide a leading platform for the development of two dimensional (2-D), flexible, thin, and robust light-emitting sources. The exceptional structure of Dirac's electrons in graphene, massless fermions, and the linear dispersion relationship with ultra-wideband plasmon and tunable surface polarities allows numerous applications in optoelectronics and plasmonics. In this article, we present a comprehensive review of recent developments in graphene-based light-emitting devices. Light emissions from graphene-based devices have been evaluated with different aspects, such as thermal emission, electroluminescence, and plasmons assisted emission. Theoretical investigations, along with experimental demonstration in the development of graphene-based light-emitting devices, have also been reviewed and discussed. Moreover, the graphene-based light-emitting devices are also addressed from the perspective of future applications, such as optical modulators, optical interconnects, and optical sensing. Finally, this review provides a comprehensive discussion on current technological issues and challenges related to the potential applications of emerging graphene-based light-emitting devices.
    Matched MeSH terms: Electronics
  14. Ali T, Jan S, Alkhodre A, Nauman M, Amin M, Siddiqui MS
    PeerJ Comput Sci, 2019;5:e216.
    PMID: 33816869 DOI: 10.7717/peerj-cs.216
    Conventional paper currency and modern electronic currency are two important modes of transactions. In several parts of the world, conventional methodology has clear precedence over its electronic counterpart. However, the identification of forged currency paper notes is now becoming an increasingly crucial problem because of the new and improved tactics employed by counterfeiters. In this paper, a machine assisted system-dubbed DeepMoney-is proposed which has been developed to discriminate fake notes from genuine ones. For this purpose, state-of-the-art models of machine learning called Generative Adversarial Networks (GANs) are employed. GANs use unsupervised learning to train a model that can then be used to perform supervised predictions. This flexibility provides the best of both worlds by allowing unlabelled data to be trained on whilst still making concrete predictions. This technique was applied to Pakistani banknotes. State-of-the-art image processing and feature recognition techniques were used to design the overall approach of a valid input. Augmented samples of images were used in the experiments which show that a high-precision machine can be developed to recognize genuine paper money. An accuracy of 80% has been achieved. The code is available as an open source to allow others to reproduce and build upon the efforts already made.
    Matched MeSH terms: Electronics
  15. Senthilpari C, Diwakar K, Singh AK
    Recent Pat Nanotechnol, 2009;3(1):61-72.
    PMID: 19149756
    The paper discuss the design of 1-bit full adder circuit using Shannon theorem. This proposed full adder circuit is used as one of the circuit component for implementation of Non- Restoring and Restoring divider circuits. The proposed adder and divider schematics are designed by using DSCH2 CAD tool and their layouts are generated by Microwind 3 VLSI CAD tool. The divider circuits are designed by using standard CMOS 0.35 microm feature size and corresponding power supply 3.5 V. The parameters analyses are carried out by BSIM 4 analysis. We have compared the simulated results of the Shannon based divider circuit with CPL and CMOS adder cell based divider circuits. We have further compared the results with published results and observed that the proposed adder cell based divider circuit dissipates lower power, gives faster response, lower latency, low EPI and high throughput.
    Matched MeSH terms: Electronics/instrumentation*
  16. Samsudin MFR, Ullah H, Tahir AA, Li X, Ng YH, Sufian S
    J Colloid Interface Sci, 2021 Mar 15;586:785-796.
    PMID: 33198982 DOI: 10.1016/j.jcis.2020.11.003
    Herein, we performed an encyclopedic analysis on the photoelectrocatalytic hydrogen production of BiVO4/g-C3N4 decorated with reduced graphene oxide (RGO) or graphene quantum dots (GQDs). The differences between RGO and GQDs as an electron mediator was revealed for the first time in the perspective of theoretical DFT analysis and experimental validation. It was found that the incorporation of GQDs as an electron mediator promotes better photoelectrocatalytic hydrogen performance in comparison to the RGO. The addition of GQD can significantly improve the activity by 25.2 and 75.7% in comparison to the BiVO4/RGO/g-C3N4 and binary composite samples, respectively. Correspondingly, the BiVO4/GQD/g-C3N4 attained the highest photocurrent density of 19.2 mA/cm2 with an ABPE of 0.57% without the presence of any sacrificial reagents. This enhancement is stemming from the low photocharge carrier transfer resistance which was further verified via DFT study. The DFT analysis revealed that the BiVO4/GQD/g-C3N4 sample shared their electronic cloud density through orbital hybridization while the BiVO4/RGO/g-C3N4 sample show less mutual sharing. Additionally, the charge redistribution of the GQDs-composite at the heterostructure interface articulates a more stable and stronger heterojunction than the RGO-composite. Notably, this study provides new insights on the effect of different carbonaceous materials (RGO and GQDs) which are often used as an electron mediator to enhance photocatalytic activity.
    Matched MeSH terms: Electronics
  17. Lim XY, Tan TYC, Muhd Rosli SH, Sa'at MNF, Sirdar Ali S, Syed Mohamed AF
    PLoS One, 2021;16(1):e0245471.
    PMID: 33465140 DOI: 10.1371/journal.pone.0245471
    INTRODUCTION: Hemp (Cannabis sativa subsp. sativa), commonly used for industrial purposes, is now being consumed by the public for various health promoting effects. As popularity of hemp research and claims of beneficial effects rises, a systematic collection of current scientific evidence on hemp's health effects and pharmacological properties is needed to guide future research, clinical, and policy decision making.

    OBJECTIVE: To provide an overview and identify the present landscape of hemp research topics, trends, and gaps.

    METHODS: A systematic search and analysis strategy according to the preferred reporting items for systematic review and meta-analysis-ScR (PRISMA-ScR) checklist on electronic databases including MEDLINE, OVID (OVFT, APC Journal Club, EBM Reviews), Cochrane Library Central and Clinicaltrials.gov was conducted to include and analyse hemp research articles from 2009 to 2019.

    RESULTS: 65 primary articles (18 clinical, 47 pre-clinical) were reviewed. Several randomised controlled trials showed hempseed pills (in Traditional Chinese Medicine formulation MaZiRenWan) improving spontaneous bowel movement in functional constipation. There was also evidence suggesting benefits in cannabis dependence, epilepsy, and anxiety disorders. Pre-clinically, hemp derivatives showed potential anti-oxidative, anti-hypertensive, anti-inflammatory, anti-diabetic, anti-neuroinflammatory, anti-arthritic, anti-acne, and anti-microbial activities. Renal protective effects and estrogenic properties were also exhibited in vitro.

    CONCLUSION: Current evidence on hemp-specific interventions are still preliminary, with limited high quality clinical evidence for any specific therapeutic indication. This is mainly due to the wide variation in test item formulation, as the multiple variants of this plant differ in their phytochemical and bioactive compounds. Future empirical research should focus on standardising the hemp plant for pharmaceutical use, and uniformity in experimental designs to strengthen the premise of using hemp in medicine.

    Matched MeSH terms: Electronics
  18. Alam MJ, Ahamed E, Faruque MRI, Islam MT, Tamim AM
    PLoS One, 2019;14(11):e0224478.
    PMID: 31714917 DOI: 10.1371/journal.pone.0224478
    Interferences and accuracy problem are one of the most talked issues in today's world for sensor technology. To deal with this contention, a microstrip framework consisting of a dual mode double negative (DNG) metamaterial based bandpass filter is presented in this article. To obtain the ultimate noise reduction bandpass filter, the proposed structure has to go through a series of development process, where the characteristics of the structure are tested to the limit. This filter is built on Rogers RT-5880 substrate with a 50Ω microstrip line. To pursue the elementary mode of resonant frequency, the ground layer of the structure is kept partially filled and a gradual analysis is executed on the prospective metamaterial (resonator) unit cell. Depending on the developed unit cell, the filter is constructed and fabricated to verify the concept, concentrating on GPS (1.55GHz), Earth Exploration-Satellite (2.70GHz) and WiMAX (3.60GHz) bands of frequencies. Moreover, the structure is investigated using Nicolson-Ross-Weir (NRW) approach to justify the metamaterial characteristics, and also tested on S-parameters, current distribution, electric and magnetic fields and quality factor. Having a propitious architecture and DNG characteristics, the proposed structure is suitable for bandpass filter for GPS, Earth Exploration-Satellite and WiMAX frequency sensing applications.
    Matched MeSH terms: Electronics
  19. Tan GL
    J Hum Ergol (Tokyo), 1996 Jun;25(1):49-62.
    PMID: 9551132 DOI: 10.11183/jhe1972.25.38
    The analyses of a few tasks were carried out in an electronics factory. The main objectives are to identify the ergonomic and biomechanical hazards of problem work tasks, to analyze each task systematically in order to evaluate the workers' exposures to the risk factors of force, posture pressure and repetition and to make recommendations to reduce the risks and hazards. The methodology includes objective measures--detailed analysis by going through training manuals, job description and production records. Subjective measures include interviewing the operator and supervisors informally, the operators were also required to fill in a structured questionnaire. The paper concludes by making recommendations to reduce the ergonomic hazards by engineering solutions, redesign or administrative controls or the implementation of procedures.
    Matched MeSH terms: Electronics*
  20. Fum WKS, Wong JHD, Tan LK
    Phys Med, 2021 Apr;84:228-240.
    PMID: 33849785 DOI: 10.1016/j.ejmp.2021.03.004
    PURPOSE: This systematic review aims to understand the dose estimation approaches and their major challenges. Specifically, we focused on state-of-the-art Monte Carlo (MC) methods in fluoroscopy-guided interventional procedures.

    METHODS: All relevant studies were identified through keyword searches in electronic databases from inception until September 2020. The searched publications were reviewed, categorised and analysed based on their respective methodology.

    RESULTS: Hundred and one publications were identified which utilised existing MC-based applications/programs or customised MC simulations. Two outstanding challenges were identified that contribute to uncertainties in the virtual simulation reconstruction. The first challenge involves the use of anatomical models to represent individuals. Currently, phantom libraries best balance the needs of clinical practicality with those of specificity. However, mismatches of anatomical variations including body size and organ shape can create significant discrepancies in dose estimations. The second challenge is that the exact positioning of the patient relative to the beam is generally unknown. Most dose prediction models assume the patient is located centrally on the examination couch, which can lead to significant errors.

    CONCLUSION: The continuing rise of computing power suggests a near future where MC methods become practical for routine clinical dosimetry. Dynamic, deformable phantoms help to improve patient specificity, but at present are only limited to adjustment of gross body volume. Dynamic internal organ displacement or reshaping is likely the next logical frontier. Image-based alignment is probably the most promising solution to enable this, but it must be automated to be clinically practical.

    Matched MeSH terms: Electronics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links